22 pages, 18620 KiB  
Article
Experimental and Numerical Characterization of the In-Plane Shear Behavior of a Load-Bearing Hollow Clay Brick Masonry System with High Thermal Performance
by Michele Serpilli, Alessandro Cameli and Francesca Stazi
Buildings 2024, 14(9), 2903; https://doi.org/10.3390/buildings14092903 - 14 Sep 2024
Viewed by 1220
Abstract
Modern masonry systems are generally built with hollow clay bricks with high thermal insulating properties, fulfilling the latest sustainability and environmental criteria for constructions. Despite the growing use of sustainable masonries in seismic-prone countries, there is a notable lack of experimental and numerical [...] Read more.
Modern masonry systems are generally built with hollow clay bricks with high thermal insulating properties, fulfilling the latest sustainability and environmental criteria for constructions. Despite the growing use of sustainable masonries in seismic-prone countries, there is a notable lack of experimental and numerical data on their structural behavior under lateral in-plane loads. The present study investigates the in-plane shear behavior of load-bearing masonry walls with thin bed joints and thermal insulating hollow clay blocks. Shear-compression tests were performed on three specimens to obtain information about their shear strength, displacement capacity and failure modes. The experimental characterization was supplemented by three shear tests on triplets, along with flexural and compression tests on the mortar for the thin joints. Furthermore, two Finite Element (FE) models were built to simulate the shear-compression tests, considering different constitutive laws and brick-to-brick contact types. The numerical simulations were able to describe both the shear failure modes and the shear strength values. The results showed that the experimental shear strength was 53% higher than the one obtained through Eurocode 6. The maximum shear load was found to be up to 75% greater compared to similar masonry specimens from the literature. These findings contribute to a better understanding of the potential structural applications of sustainable hollow clay block masonry in earthquake-prone areas. Full article
(This article belongs to the Special Issue The Latest Research on Building Materials and Structures)
Show Figures

Figure 1

32 pages, 43577 KiB  
Article
Improved Bond Stress-Slip Relationships for Carbon Fibre-Reinforced Polymer-Strengthened Masonry Triplets
by Seyyed Motasam Hashemi and Ashraf Ayoub
Buildings 2024, 14(1), 257; https://doi.org/10.3390/buildings14010257 - 17 Jan 2024
Cited by 3 | Viewed by 1555
Abstract
Carbon fibre-reinforced polymer (CFRP) emerges as a viable solution for reinforcing unreinforced masonry (URM) walls subjected to shear loads. While masonry structures are straightforward to construct, the complexity of the construction materials, especially in terms of their mechanical properties, poses challenges for numerical [...] Read more.
Carbon fibre-reinforced polymer (CFRP) emerges as a viable solution for reinforcing unreinforced masonry (URM) walls subjected to shear loads. While masonry structures are straightforward to construct, the complexity of the construction materials, especially in terms of their mechanical properties, poses challenges for numerical studies of their structural behaviour. Walls, being fundamental components in masonry construction, play a crucial role in transferring both horizontal and vertical lateral forces. This study investigates the enhancement of masonry wall behaviour through the reinforcement of CFRP. CFRP reinforcement increases ductility and strength, reducing the risk of failure under shear conditions. Additionally, CFRP composites present a practical solution to strengthening masonry structures compared to traditional reinforcement. However, brick, mortar, and CFRP have not been thoroughly investigated. Experimental tests on the bond behaviour of different configurations of CFRP-retrofitted masonry triplets have not been performed before and are therefore presented in this paper. Triplet specimens, comprising three bricks and two mortar joints, both with and without CFRP strengthening, were subjected to bond testing. The study affirms that masonry triplets strengthened with CFRP under shear loads exhibit strength levels at least four to six times greater than those without CFRP. The experimental work was carried out with eight different CFRP configurations on triplet masonry, and each test was repeated four times. Further, the bond stress-slip relationship in the case of masonry triplets with and without CFRP was predicted with new mathematical equations based on the conducted test results. These equations were included in the commercial finite element software ANSYS and used to conduct simulations of CFRP-reinforced masonry triplets. The numerical results indicate good agreement between the finite element model and the test results. The outcome of this research improves the current knowledge on the use of CFRP to reinforce masonry walls with brick and mortar, which will contribute to the understanding of the effect of CFRP on masonry structures. Full article
Show Figures

Figure 1

28 pages, 12593 KiB  
Article
Effect of a Novel Dowel and Cramp on the In-Plane Behavior of Multi-Leaf Stone Masonry Walls Proposed for Modern Masonry Buildings
by Ahmed Cavit Ziya and Abdulkerim İlgün
Buildings 2023, 13(5), 1235; https://doi.org/10.3390/buildings13051235 - 8 May 2023
Viewed by 2467
Abstract
This study discusses the experimental assessment of the in-plane mechanical behavior of a multi-leaf stone masonry wall built from cut stone and reinforced with metal connectors (cramps and dowels). Inspired by conventional multi-leaf stone walls, the wall is meant for use in modern [...] Read more.
This study discusses the experimental assessment of the in-plane mechanical behavior of a multi-leaf stone masonry wall built from cut stone and reinforced with metal connectors (cramps and dowels). Inspired by conventional multi-leaf stone walls, the wall is meant for use in modern stone masonry buildings. The wall is constructed from two parallel load-bearing walls with a cavity between them, which aims to conceal the installation and insulation needed in modern buildings. The load-bearing walls are connected with cramps and dowels at certain intervals, so the wall works as a single section against horizontal and vertical loads. To characterize the in-plane behavior of the proposed wall, compressive, triplet, and diagonal compression tests were conducted to investigate the compressive strength, shear strength, modulus of elasticity, stiffness, ductility, and energy absorption of the wall. Compared with dry and mortar joint walls, dowels increased the wall’s initial shear capacity by 11 and 19 times, respectively. Applying cramps without curving channels inside the individual stone elements decreased the compressive strength by 18%. The energy absorption of the designed walls with metal connectors was substantially increased to that of the specimens representing conventional stone walls. The results show the wall’s applicability due to its higher shear strength and minimal drop in compressive strength, which is within acceptable limits. Full article
(This article belongs to the Special Issue Seismic Behaviour of Reinforced and Confined Masonry Buildings)
Show Figures

Figure 1

18 pages, 9125 KiB  
Article
Experimental and Numerical Mechanical Characterization of Unreinforced and Reinforced Masonry Elements with Weak Air Lime Mortar Joints
by Giuseppe Brando, Gianluca Vacca, Francesco Di Michele, Ilaria Capasso and Enrico Spacone
Sustainability 2022, 14(7), 3990; https://doi.org/10.3390/su14073990 - 28 Mar 2022
Cited by 5 | Viewed by 1961
Abstract
This paper deals with the results of an experimental and numerical campaign aimed at characterizing the mechanical response of masonry components and panels made of limestone units kept together by weak air lime mortar joints. The selected air lime mortar, typical of ancient [...] Read more.
This paper deals with the results of an experimental and numerical campaign aimed at characterizing the mechanical response of masonry components and panels made of limestone units kept together by weak air lime mortar joints. The selected air lime mortar, typical of ancient masonry buildings but difficult to be built-up artificially, was specifically prepared for the experimental analyses, with the aim of obtaining a laboratory compression strength of 0.25–0.50 MPa. In the first part of the paper, the performed tests concerning the strength of the units (mean compression strength of 80 MPa) and of the mortar (mean compression strength after 28 days of 0.30 MPa), are described for different curing periods. Moreover, tests of masonry triplets in shear (shear strength of 0.11 MPa for null axial forces) are shown and used in order to establish the main parameters of the Mohr–Coulomb failure criterium. Then, the calibration of a continuous numerical micro-model implemented in Kratos Multiphysics is presented. The model is used for reproducing the behavior of an unreinforced panel in shear made of the studied masonry and to appraise the effectiveness of a FRCM- (Fiber Reinforced Cementitious Matrix) based reinforcement intervention applied. The obtained results proved that FRCM allows to increase the strength of the considered masonry type by about eight times and the ductility by about thirteen times. Full article
(This article belongs to the Special Issue Sustainable Materials for Construction)
Show Figures

Figure 1

13 pages, 15399 KiB  
Article
Experimental Characterization of the Initial Shear Strength of Composite Masonry including AAC Blocks and DPC Layers
by Martijn Vanheukelom, Rajarshi Das, Hervé Degée and Bram Vandoren
Sustainability 2021, 13(22), 12749; https://doi.org/10.3390/su132212749 - 18 Nov 2021
Cited by 6 | Viewed by 2237
Abstract
Modern masonry structures, apart from having a load-bearing function, are more and more subjected to additional non-structural requirements related to, e.g., thermal insulation and moisture control. This has respectively led to the introduction of thermal break layers, in practice often executed using autoclaved [...] Read more.
Modern masonry structures, apart from having a load-bearing function, are more and more subjected to additional non-structural requirements related to, e.g., thermal insulation and moisture control. This has respectively led to the introduction of thermal break layers, in practice often executed using autoclaved aerated concrete (AAC) blocks, and damp proof courses (DPC) in masonry walls. These modifications have an impact on the mechanical characteristics of the masonry, such as the shear strength. In this paper, an extensive experimental campaign is therefore conducted on masonry triplets to investigate the initial shear strength of concrete block and clay brick masonry, including AAC blocks. The impact of the the presence of a polyethylene DPC layer is also studied. Moreover, the position of the DPC membrane is varied, i.e., directly on top of the brick (which is generally not recommended yet common in construction practice) and in the middle of the mortar joint. In total, 138 shear tests were performed according to the EN 1052-3 standard, with low to moderate precompression levels. The test results focus on the differences in friction angle, shear modulus, and friction coefficient. It is concluded that the presence of an AAC block decreases the initial shear strength to a value which is lower than the one assumed by Eurocode 6. Moreover, when adding a DPC membrane, the shear strength is reduced even further to almost zero, in particular when the membrane is not put in the middle of the mortar joint. Full article
(This article belongs to the Special Issue Sustainable Concrete Masonry: AAC and LWAC)
Show Figures

Figure 1

16 pages, 19005 KiB  
Article
Experimental Investigation of Traditional Clay Brick and Lime Mortar Intended for Restoration of Cultural Heritage Sites
by Gayoon Lee, Jun Hyoung Park, Khoa V. A. Pham, Chan Hee Lee and Kihak Lee
Appl. Sci. 2021, 11(13), 6228; https://doi.org/10.3390/app11136228 - 5 Jul 2021
Cited by 10 | Viewed by 4556
Abstract
To properly restore masonry cultural heritage sites, the materials used for retrofitting can have a critical effect, and this requires standards for traditional Korean brick and lime mortar to be examined. This study experimentally investigated the material characteristics of Korean traditional bricks and [...] Read more.
To properly restore masonry cultural heritage sites, the materials used for retrofitting can have a critical effect, and this requires standards for traditional Korean brick and lime mortar to be examined. This study experimentally investigated the material characteristics of Korean traditional bricks and two types of lime mortar (quicklime lumps and powdered hydrated lime) and the strength of masonry specimens made from those materials. Four different mixing ratios of lime, sand and white cement were considered as material parameters in this study. The experiment included uniaxial compressive testing and flexural testing to examine the mortars’ mechanical properties, and compression tests, triplet shear tests and diagonal compression tests for the masonry specimens. The results found that the strength of the masonry specimens was not necessarily associated with the mortar’s strength, but rather the cohesion between brick and mortar. In the material test, adding white cement had no noticeable effect on mortar strength. Meanwhile, in the masonry specimen, the effect of the added white cement was significant in terms of compressive and shear strength. This suggests that the bonding ratio between mortar and brick, which is an important factor influencing the behavior of bricks, was stronger with the addition of white cement. Furthermore, it was found that quicklime lumps had a lower strength than powdered hydrated lime. The test specimen with white cement added to powdered hydrated lime exhibited the greatest strength. Full article
Show Figures

Figure 1

19 pages, 1751 KiB  
Article
Triplet Test on Rubble Stone Masonry: Numerical Assessment of the Shear Mechanical Parameters
by Michele Angiolilli and Amedeo Gregori
Buildings 2020, 10(3), 49; https://doi.org/10.3390/buildings10030049 - 9 Mar 2020
Cited by 25 | Viewed by 7146
Abstract
Rubble stone masonry walls are widely diffused in most of the cultural and architectural heritage of historical cities. The mechanical response of such material is rather complicated to predict due to its composite nature. Vertical compression tests, diagonal compression tests, and shear-compression tests [...] Read more.
Rubble stone masonry walls are widely diffused in most of the cultural and architectural heritage of historical cities. The mechanical response of such material is rather complicated to predict due to its composite nature. Vertical compression tests, diagonal compression tests, and shear-compression tests are usually adopted to investigate experimentally the mechanical properties of stone masonries. However, further tests are needed for the safety assessment of these ancient structures. Since the relation between normal and shear stresses plays a major role in the shear behavior of masonry joints, governing the failure mode, a triplet test configuration is herein investigated. First, the experimental tests carried out at the laboratory of the University of L’Aquila on stone masonry specimens are presented. Then, the triplet test is simulated by using the total strain crack model, which reflects all the ultimate states of quasi-brittle material such as cracking, crushing, and shear failure. The goal of the numerical investigation is to evaluate the shear mechanical parameters of the masonry sample, including strength, dilatancy, normal, and shear deformations. Furthermore, the effect of (i) confinement pressure and (ii) bond behavior at the sample-plate interfaces are investigated, showing that they can strongly influence the mechanical response of the walls. Full article
(This article belongs to the Section Building Structures)
Show Figures

Figure 1

19 pages, 7393 KiB  
Article
Sustainable Brick Masonry Bond Design and Analysis: An Application of a Decision-Making Technique
by Syyed Adnan Raheel Shah, Hunain Arshad, Muhammad Farhan, Syed Safdar Raza, Mudasser Muneer Khan, Sunera Imtiaz, Gullnaz Shahzadi, Muhammad Ahmed Qurashi and Muhammad Waseem
Appl. Sci. 2019, 9(20), 4313; https://doi.org/10.3390/app9204313 - 14 Oct 2019
Cited by 6 | Viewed by 14099
Abstract
This research intends to explore the sustainable masonry bond formation and interface behaviour of brick masonry bonds with different cement mortar ratios. To test the sustainable behaviour of different brick bonds, different tests were applied to evaluate the performance of the developed five [...] Read more.
This research intends to explore the sustainable masonry bond formation and interface behaviour of brick masonry bonds with different cement mortar ratios. To test the sustainable behaviour of different brick bonds, different tests were applied to evaluate the performance of the developed five brick masonry structures with the help of four mortar ratios. Following that pattern, the methodologies of a prism triplet test, a bond wrench test, a shear bond test and strength tests for brick masonry were applied. The prism triplet test explained the bonding behaviour of mortar by producing a maximum strength (0.21 MPa) with a 1:3 mix ratio, and the minimum strength (0.095 MPa) with a 1:8 mix ratio. The bond wrench test showed a bond strength of maximum 0.0685 MPa with a mortar ratio of 1:3 and a minimum of 0.035 MPa with a mortar ratio of 1:8. The strength tests for masonry structures expressed that compressive strength (0.786 MPa) and flexural strength (0.352 MPa) were found to be at maximum level with a mortar ratio (1:3) with an English bond formation. For predictions of compressive and flexural strength, artificial neural networks (ANNs) were deployed, and successful predictions of these values along with the relationships between different properties of the material, mortar combinations and bond combinations are presented to complete the exploration of the relationship. This pattern can be helpful for the selection of sustainable brick masonry formations for housing development. Full article
(This article belongs to the Special Issue New Trends of Sustainability in Civil Engineering and Architecture)