Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (4)

Search Parameters:
Keywords = transeptal puncture

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
10 pages, 608 KiB  
Review
Transeptal Puncture Complications: What to Watch for and How to Avoid Them
by Nicolò Azzola Guicciardi, Carlotta De Carlo and Francesco Maisano
Complications 2025, 2(2), 14; https://doi.org/10.3390/complications2020014 - 16 Jun 2025
Viewed by 581
Abstract
Transseptal puncture (TSP) is an essential step for left heart procedures that allows access to the left atrium (LA) through the fossa ovalis (FO) of the interatrial septum (IS). Initially developed for diagnostic purposes, today, it is performed for procedures that require large-bore [...] Read more.
Transseptal puncture (TSP) is an essential step for left heart procedures that allows access to the left atrium (LA) through the fossa ovalis (FO) of the interatrial septum (IS). Initially developed for diagnostic purposes, today, it is performed for procedures that require large-bore device delivery systems and complex three-dimensional navigation in the left atrium. TSP supports various interventions, including atrial fibrillation ablation, left atrial appendage closure, and transcatheter mitral valve repair and replacement. While traditionally performed with Brockenbrough needles under fluoroscopic guidance, the integration of transesophageal and intracardiac echocardiography (TEE/ICE) has significantly improved its safety and precision. Despite its generally high success rate, TSP poses challenges in complex anatomies or for less experienced operators, with complications such as cardiac tamponade, aortic root puncture, and embolic events. Anatomical variations, such as thickened or floppy septa, further complicate the procedure. Technological advancements, including radiofrequency-based systems and specialized guidewires, have enhanced safety in difficult cases. Effective training, including echocardiography and complication management, is vital for operator proficiency. This review outlines the procedural steps for safe TSP, emphasizing proper equipment selection, anatomical considerations, and vascular access techniques. Common complications are discussed alongside management strategies. Advanced tools and techniques for addressing challenging scenarios are highlighted. Full article
Show Figures

Figure 1

11 pages, 1218 KiB  
Article
Transcatheter Mitral Valve-in-Valve Implantation with the Balloon-Expandable Myval Device
by Sara Blasco-Turrión, Ana Serrador-Frutos, John Jose, Gunasekaran Sengotuvelu, Ashok Seth, Victor G. Aldana, Juan Pablo Sánchez-Luna, Jose Carlos Gonzalez-Gutiérrez, Mario García-Gómez, Javier Gómez-Herrero, Cristhian Aristizabal, J. Alberto San Román and Ignacio J. Amat-Santos
J. Clin. Med. 2022, 11(17), 5210; https://doi.org/10.3390/jcm11175210 - 2 Sep 2022
Cited by 8 | Viewed by 3654
Abstract
Background: The vast majority of transcatheter valve-in-valve (ViV) mitral procedures have been reported with the SAPIEN family. We aimed to report the preliminary experience with the Myval balloon-expandable device in this setting. Methods: Multicenter retrospective study of high-risk surgical patients with mitral bioprosthesis [...] Read more.
Background: The vast majority of transcatheter valve-in-valve (ViV) mitral procedures have been reported with the SAPIEN family. We aimed to report the preliminary experience with the Myval balloon-expandable device in this setting. Methods: Multicenter retrospective study of high-risk surgical patients with mitral bioprosthesis degeneration undergoing transcatheter ViV implantation with Myval device. Results: A total of 11 patients from five institutions were gathered between 2019 and 2022 (age 68 ± 7.8, 63% women). The peak and mean transvalvular gradients were 27 ± 5 mmHg and 14.7 ± 2.3 mmHg, respectively, and the predicted neo-left ventricular outflow tract (neo-LVOT) area was 183.4 ± 56 mm2 (range: 171 to 221 mm2). The procedures were performed via transfemoral access in all cases (through echocardiography-guided transeptal puncture (81.8% transesophageal, 11.2% intracardiac)). Technical success was achieved in all cases, with no significant residual mitral stenosis in any of them (peak 7.2 ± 2.7 and mean gradient 3.4 ± 1.7 mmHg) and no complications during the procedure. There were no data of LVOT obstruction, migration, or paravalvular leak in any case. Mean hospital stay was 3 days, with one major vascular complication and no stroke. At 6-month follow-up, there was one case with suboptimal anticoagulation presenting an increase in the transmitral gradients (mean 15 mmHg) that normalized after optimization of the anticoagulation, but no other relevant events. Conclusions: Transseptal ViV mitral implantation with the balloon-expandable Myval device was feasible and safe avoiding redo surgery in high-risk patients with bioprosthesis degeneration. Full article
(This article belongs to the Special Issue Mitral Valve Disease: State of the Art)
Show Figures

Figure 1

12 pages, 411 KiB  
Article
Cryoballoon Ablation for Persistent and Paroxysmal Atrial Fibrillation: Procedural Differences and Results from the Spanish Registry (RECABA)
by Ermengol Vallès, Jesús Jiménez, Julio Martí-Almor, Jorge Toquero, José Miguel Ormaetxe, Alberto Barrera, Arcadio García-Alberola, José Manuel Rubio, Pablo Moriña, Carlos Grande, Maria Fé Arcocha, Rafael Peinado, Rocío Cózar, Julio Hernández, Luisa Pérez-Alvarez, Larraitz Gaztañaga, Angel Ferrero-De Loma-Osorio, Ricardo Ruiz-Granell, Roger Villuendas and Jesús Daniel Martínez-Alday
J. Clin. Med. 2022, 11(5), 1166; https://doi.org/10.3390/jcm11051166 - 22 Feb 2022
Cited by 2 | Viewed by 2241
Abstract
Introduction: Cryoballoon ablation (CBA) has become a standard treatment for paroxysmal atrial fibrillation (PaAF) but limited data is available for outcomes in patients with persistent atrial fibrillation (PeAF). Methods: We analyzed the first 944 patients included in the Spanish Prospective Multi-center Observation Post-market [...] Read more.
Introduction: Cryoballoon ablation (CBA) has become a standard treatment for paroxysmal atrial fibrillation (PaAF) but limited data is available for outcomes in patients with persistent atrial fibrillation (PeAF). Methods: We analyzed the first 944 patients included in the Spanish Prospective Multi-center Observation Post-market Registry to compare characteristics and outcomes of patients undergoing CBA for PeAF versus PaAF. Results: A total of 944 patients (57.8 ± 10.4 years; 70.1% male) with AF (27.9% persistent) were prospectively included from 25 centers. PeAF patients were more likely to have structural heart disease (67.7 vs. 11.4%; p < 0.001) and left atrium dilation (72.6 vs. 43.3%; p < 0.001). CBA of PeAF was less likely to be performed under general anesthesia (10.7 vs. 22.2%; p < 0.001), with an arterial line (32.2 vs. 44.6%; p < 0.001) and assisted transeptal puncture (11.9 vs. 17.9%; p = 0.025). During an application, PeAF patients had a longer time to −30 °C (35.91 ± 14.20 vs. 34.93 ± 12.87 s; p = 0.021) and a colder balloon nadir temperature during vein isolation (−35.04 ± 9.58 vs. −33.61 ± 10.32 °C; p = 0.004), but received fewer bonus freeze applications (30.7 vs. 41.1%; p < 0.001). There were no differences in acute pulmonary vein isolation and procedure-related complications. Overall, 76.7% of patients were free from AF recurrences at 15-month follow-up (78.9% in PaAF vs. 70.9% in PeAF; p = 0.09). Conclusions: Patients with PeAF have a more diseased substrate, and CBA procedures performed in such patients were more simplified, although longer/colder freeze applications were often applied. The acute efficacy/safety profile of CBA was similar between PaAF and PeAF patients, but long-term results were better in PaAF patients. Full article
(This article belongs to the Section Cardiology)
Show Figures

Figure 1

9 pages, 4865 KiB  
Article
Morphological Study of Fossa Ovalis in Formalin-Fixed Human Hearts and Its Clinical Importance
by Monica Adriana Vaida, Caius Glad Streian, Cristina Gug, Nawwaf Sebastian Damen, Adelina Maria Jianu, Andreea Grigoriță and Laura Grigoriță
Medicina 2021, 57(11), 1254; https://doi.org/10.3390/medicina57111254 - 16 Nov 2021
Cited by 4 | Viewed by 5608
Abstract
Background and Objectives: Our study aimed to investigate the gross anatomy aspects of the fossa ovalis (FO) and the presence of some anatomical variation resulting from the incomplete fusion of septum primum and septum secundum, such as an atrial septal pouch (SP) and [...] Read more.
Background and Objectives: Our study aimed to investigate the gross anatomy aspects of the fossa ovalis (FO) and the presence of some anatomical variation resulting from the incomplete fusion of septum primum and septum secundum, such as an atrial septal pouch (SP) and left atrial septal ridge. Materials and Methods: Thirty-one adult human hearts removed from formalin-fixed specimens were examined to provide information about the morphology of the FO. The organs were free of any gross anatomically visible pathological conditions. Results: The most common variants were the FO located in the inferior part of the interatrial septum (64.51%), circular (61.3%), with a net-like structure (51.62%), prominent limbus (93.55%), and patent foramen ovale (PFO) (25.8%). The right SP was observed in 9.67% of specimens, the left SP was observed in 29.03% of cases, and in 51.61% of cases, a double SP was observed. One sample presented a right SP and a double left SP, and one case showed a triple left SP, which was not reported previously to our knowledge. Conclusions: Knowledge of the interatrial septal anatomy becomes important for interventional cardiologists and should be documented before transeptal puncture. Full article
(This article belongs to the Special Issue Topographic Anatomy of the Human Body)
Show Figures

Figure 1

Back to TopTop