Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (5)

Search Parameters:
Keywords = technetium-99m-pertechnetate

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
25 pages, 9037 KiB  
Review
Imaging Recommendations for Diagnosis and Management of Primary Parathyroid Pathologies: A Comprehensive Review
by Nivedita Chakrabarty, Abhishek Mahajan, Sandip Basu and Anil K. D’Cruz
Cancers 2024, 16(14), 2593; https://doi.org/10.3390/cancers16142593 - 19 Jul 2024
Cited by 8 | Viewed by 4562
Abstract
Parathyroid pathologies are suspected based on the biochemical alterations and clinical manifestations, and the predominant roles of imaging in primary hyperparathyroidism are localisation of tumour within parathyroid glands, surgical planning, and to look for any ectopic parathyroid tissue in the setting of recurrent [...] Read more.
Parathyroid pathologies are suspected based on the biochemical alterations and clinical manifestations, and the predominant roles of imaging in primary hyperparathyroidism are localisation of tumour within parathyroid glands, surgical planning, and to look for any ectopic parathyroid tissue in the setting of recurrent disease. This article provides a comprehensive review of embryology and anatomical variations of parathyroid glands and their clinical relevance, surgical anatomy of parathyroid glands, differentiation between multiglandular parathyroid disease, solitary adenoma, atypical parathyroid tumour, and parathyroid carcinoma. The roles, advantages and limitations of ultrasound, four-dimensional computed tomography (4DCT), radiolabelled technetium-99 (99mTc) sestamibi or dual tracer 99mTc pertechnetate and 99mTc-sestamibi with or without single photon emission computed tomography (SPECT) or SPECT/CT, dynamic enhanced magnetic resonance imaging (4DMRI), and fluoro-choline positron emission tomography (18F-FCH PET) or [11C] Methionine (11C -MET) PET in the management of parathyroid lesions have been extensively discussed in this article. The role of fluorodeoxyglucose PET (FDG-PET) has also been elucidated in this article. Management guidelines for parathyroid carcinoma proposed by the American Society of Clinical Oncology (ASCO) have also been described. An algorithm for management of parathyroid lesions has been provided at the end to serve as a quick reference guide for radiologists, clinicians and surgeons. Full article
(This article belongs to the Section Cancer Causes, Screening and Diagnosis)
Show Figures

Figure 1

16 pages, 2276 KiB  
Case Report
Pitfalls of DualTracer 99m-Technetium (Tc) Pertechnetate and Sestamibi Scintigraphy before Parathyroidectomy: Between Primary-Hyperparathyroidism-Associated Parathyroid Tumour and Ectopic Thyroid Tissue
by Mara Carsote, Mihaela Stanciu, Florina Ligia Popa, Oana-Claudia Sima, Eugenia Petrova, Anca-Pati Cucu and Claudiu Nistor
Medicina 2024, 60(1), 15; https://doi.org/10.3390/medicina60010015 - 21 Dec 2023
Viewed by 2237
Abstract
Diagnosis of primary hyperparathyroidism (PHP) is based on blood assessments in terms of synchronous high calcium and PTH (parathormone), but further management, particularly parathyroid surgery that provides the disease cure in 95–99% of cases, requires an adequate localisation of the parathyroid tumour/tumours as [...] Read more.
Diagnosis of primary hyperparathyroidism (PHP) is based on blood assessments in terms of synchronous high calcium and PTH (parathormone), but further management, particularly parathyroid surgery that provides the disease cure in 95–99% of cases, requires an adequate localisation of the parathyroid tumour/tumours as the originating source, with ultrasound and 99m-Technetium (99m-Tc) sestamibi scintigraphy being the most widely used. We aimed to introduce an adult female case diagnosed with PHP displaying unexpected intra-operatory findings (ectopic thyroid tissue) in relation to concordant pre-operatory imaging modalities (ultrasound + dual-phase 99m-Tc pertechnetate and sestamibi scintigraphy + computed tomography) that indicated bilateral inferior parathyroid tumours. A sudden drop in PTH following the removal of the first tumour was the clue for performing an extemporaneous exam for the second mass that turned out to be non-malignant ectopic thyroid tissue. We overviewed some major aspects starting from this case in point: the potential pitfalls of pre-operatory imaging in PHP; the concordance/discordance of pre-parathyroidectomy localisation modalities; the need of using an additional intra-operatory procedure; and the clues of providing a distinction between pathological parathyroids and thyroid tissue. This was a case of adult PHP, whereas triple localisation methods were used before parathyroidectomy, showing concordant results; however, the second parathyroid adenoma was a false positive image and an ectopic thyroid tissue was confirmed. The pre-operatory index of suspicion was non-existent in this patient. Hybrid imaging modalities are most probably required if both thyroid and parathyroid anomalies are suspected, but, essentially, awareness of the potential pitfalls is mandatory from the endocrine and surgical perspectives. Current gaps in imaging knowledge to guide us in this area are expected to be solved by the significant progress in functional imaging modalities. However, the act of surgery, including the decision of a PTH assay or extemporaneous exam (as seen in our case), represents the key to a successful removal procedure. Moreover, many parathyroid surgeons may currently perform 4-gland exploration routinely, precisely to avoid the shortcomings of preoperative localisation. Full article
(This article belongs to the Special Issue Recent Clinical and Basic Research on Endocrine Surgery)
Show Figures

Figure 1

10 pages, 1601 KiB  
Article
The GRPR Antagonist [99mTc]Tc-maSSS-PEG2-RM26 towards Phase I Clinical Trial: Kit Preparation, Characterization and Toxicity
by Ayman Abouzayed, Jesper Borin, Fanny Lundmark, Anastasiya Rybina, Sophia Hober, Roman Zelchan, Vladimir Tolmachev, Vladimir Chernov and Anna Orlova
Diagnostics 2023, 13(9), 1611; https://doi.org/10.3390/diagnostics13091611 - 2 May 2023
Cited by 4 | Viewed by 2388
Abstract
Gastrin-releasing peptide receptors (GRPRs) are overexpressed in the majority of primary prostate tumors and in prostatic lymph node and bone metastases. Several GRPR antagonists were developed for SPECT and PET imaging of prostate cancer. We previously reported a preclinical evaluation of the GRPR [...] Read more.
Gastrin-releasing peptide receptors (GRPRs) are overexpressed in the majority of primary prostate tumors and in prostatic lymph node and bone metastases. Several GRPR antagonists were developed for SPECT and PET imaging of prostate cancer. We previously reported a preclinical evaluation of the GRPR antagonist [99mTc]Tc-maSSS-PEG2-RM26 (based on [D-Phe6, Sta13, Leu14-NH2]BBN(6-14)) which bound to GRPR with high affinity and had a favorable biodistribution profile in tumor-bearing animal models. In this study, we aimed to prepare and test kits for prospective use in an early-phase clinical study. The kits were prepared to allow for a one-pot single-step radiolabeling with technetium-99m pertechnetate. The kit vials were tested for sterility and labeling efficacy. The radiolabeled by using the kit GRPR antagonist was evaluated in vitro for binding specificity to GRPR on PC-3 cells (GRPR-positive). In vivo, the toxicity of the kit constituents was evaluated in rats. The labeling efficacy of the kits stored at 4 °C was monitored for 18 months. The biological properties of [99mTc]Tc-maSSS-PEG2-RM26, which were obtained after this period, were examined both in vitro and in vivo. The one-pot (gluconic acid, ethylenediaminetetraacetic acid, stannous chloride, and maSSS-PEG2-RM26) single-step radiolabeling with technetium-99m was successful with high radiochemical yields (>97%) and high molar activities (16–24 MBq/nmol). The radiolabeled peptide maintained its binding properties to GRPR. The kit constituents were sterile and non-toxic when tested in living subjects. In conclusion, the prepared kit is considered safe in animal models and can be further evaluated for use in clinics. Full article
(This article belongs to the Special Issue Future Trends in Radioisotope-Based Imaging 2.0)
Show Figures

Figure 1

23 pages, 8399 KiB  
Review
Technegas, A Universal Technique for Lung Imaging in Nuclear Medicine: Technology, Physicochemical Properties, and Clinical Applications
by Isra Khatib and Paul M. Young
Pharmaceutics 2023, 15(4), 1108; https://doi.org/10.3390/pharmaceutics15041108 - 30 Mar 2023
Cited by 4 | Viewed by 7930
Abstract
Technegas was developed in Australia as an imaging radioaerosol in the late 1980s and is now commercialized by Cyclomedica, Pty Ltd. for diagnosing pulmonary embolism (PE). Technegas is produced by heating technetium-99m in a carbon crucible for a few seconds at high temperatures [...] Read more.
Technegas was developed in Australia as an imaging radioaerosol in the late 1980s and is now commercialized by Cyclomedica, Pty Ltd. for diagnosing pulmonary embolism (PE). Technegas is produced by heating technetium-99m in a carbon crucible for a few seconds at high temperatures (2750 °C) to generate technetium–carbon nanoparticles with a gas-like behaviour. The submicron particulates formed allow easy diffusion to the lung periphery when inhaled. Technegas has been used for diagnosis in over 4.4 m patients across 60 countries and now offers exciting opportunities in areas outside of PE, including asthma and chronic obstructive pulmonary disease (COPD). The Technegas generation process and the physicochemical attributes of the aerosol have been studied over the past 30 years in parallel with the advancement in different analytical methodologies. Thus, it is now well established that the Technegas aerosol has a radioactivity aerodynamic diameter of <500 nm and is composed of agglomerated nanoparticles. With a plethora of literature studying different aspects of Technegas, this review focuses on a historical evaluation of the different methodologies’ findings over the years that provides insight into a scientific consensus of this technology. Also, we briefly discuss recent clinical innovations using Technegas and a brief history of Technegas patents. Full article
Show Figures

Figure 1

19 pages, 6498 KiB  
Article
14 MeV Neutrons for 99Mo/99mTc Production: Experiments, Simulations and Perspectives
by Marco Capogni, Antonino Pietropaolo, Lina Quintieri, Maurizio Angelone, Alessandra Boschi, Mauro Capone, Nadia Cherubini, Pierino De Felice, Alessandro Dodaro, Adriano Duatti, Aldo Fazio, Stefano Loreti, Petra Martini, Guglielmo Pagano, Micol Pasquali, Mario Pillon, Licia Uccelli and Aldo Pizzuto
Molecules 2018, 23(8), 1872; https://doi.org/10.3390/molecules23081872 - 27 Jul 2018
Cited by 37 | Viewed by 7773
Abstract
Background: the gamma-emitting radionuclide Technetium-99m (99mTc) is still the workhorse of Single Photon Emission Computed Tomography (SPECT) as it is used worldwide for the diagnosis of a variety of phatological conditions. 99mTc is obtained from 99Mo/99mTc generators [...] Read more.
Background: the gamma-emitting radionuclide Technetium-99m (99mTc) is still the workhorse of Single Photon Emission Computed Tomography (SPECT) as it is used worldwide for the diagnosis of a variety of phatological conditions. 99mTc is obtained from 99Mo/99mTc generators as pertechnetate ion, which is the ubiquitous starting material for the preparation of 99mTc radiopharmaceuticals. 99Mo in such generators is currently produced in nuclear fission reactors as a by-product of 235U fission. Here we investigated an alternative route for the production of 99Mo by irradiating a natural metallic molybdenum powder using a 14-MeV accelerator-driven neutron source. Methods: after irradiation, an efficient isolation and purification of the final 99mTc-pertechnetate was carried out by means of solvent extraction. Monte Carlo simulations allowed reliable predictions of 99Mo production rates for a newly designed 14-MeV neutron source (New Sorgentina Fusion Source). Results: in traceable metrological conditions, a level of radionuclidic purity consistent with accepted pharmaceutical quality standards, was achieved. Conclusions: we showed that this source, featuring a nominal neutron emission rate of about 1015 s−1, may potentially supply an appreciable fraction of the current 99Mo global demand. This study highlights that a robust and viable solution, alternative to nuclear fission reactors, can be accomplished to secure the long-term supply of 99Mo. Full article
Show Figures

Graphical abstract

Back to TopTop