Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (8)

Search Parameters:
Keywords = silicon and polyimide microfabrication

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
10 pages, 6579 KB  
Article
Conformal Retinal Image Sensor Based on Electrochemically Exfoliated MoS2 Nanosheets
by Tianxiang Li, Hao Yuan, Wentong Cai, Qi Su, Lingxian Kong, Bo Sun and Tielin Shi
Nanomaterials 2025, 15(8), 622; https://doi.org/10.3390/nano15080622 - 18 Apr 2025
Viewed by 440
Abstract
Retina-like photoimaging devices with features such as a wide-field-of-view and high spatial resolution have wide application prospects in retinal prosthetics and remote sensing. However, the fabrication of flexible and conformal surfaces is hindered by the incompatible microfabrication processes of traditional rigid, silicon-based substrates. [...] Read more.
Retina-like photoimaging devices with features such as a wide-field-of-view and high spatial resolution have wide application prospects in retinal prosthetics and remote sensing. However, the fabrication of flexible and conformal surfaces is hindered by the incompatible microfabrication processes of traditional rigid, silicon-based substrates. A kirigami strategy for hemispherical surface assembly is proposed to construct a MoS2-based retina-like photodetector array. The device is first fabricated on a flat polyimide (PI) substrate and then tailored using a laser. By approximating the spherical surface using planar sectors, the laser-cut PI film can tightly adhere to the PDMS spherical shell without significant wrinkles. The responsivity and specific detectivity of our conformal photodetector can reach as high as 247.9 A/W and 6.16 × 1011 Jones, respectively. The array integrates 180 pixels on a spherical crown with a radius of 11 mm, and a hollow letter “T” is successfully recognized. Comprehensive experimental results in this work reveal the utility of our device for photoelectric detection and imaging. We believe that our work provides a new methodology for the exploitation of 2D material-based retinal image sensors. Full article
(This article belongs to the Section Nanoelectronics, Nanosensors and Devices)
Show Figures

Figure 1

17 pages, 11338 KB  
Article
Fabrication and Electrical Characterization of Low-Temperature Polysilicon Films for Sensor Applications
by Filipa C. Mota, Inês S. Garcia, Aritz Retolaza, Dimitri E. Santos, Patrícia C. Sousa, Diogo E. Aguiam, Rosana A. Dias, Carlos Calaza, Alexandre F. Silva and Filipe S. Alves
Micromachines 2025, 16(1), 57; https://doi.org/10.3390/mi16010057 - 31 Dec 2024
Cited by 1 | Viewed by 4131
Abstract
The development of low-temperature piezoresistive materials provides compatibility with standard silicon-based MEMS fabrication processes. Additionally, it enables the use of such material in flexible substrates, thereby expanding the potential for various device applications. This work demonstrates, for the first time, the fabrication of [...] Read more.
The development of low-temperature piezoresistive materials provides compatibility with standard silicon-based MEMS fabrication processes. Additionally, it enables the use of such material in flexible substrates, thereby expanding the potential for various device applications. This work demonstrates, for the first time, the fabrication of a 200 nm polycrystalline silicon thin film through a metal-induced crystallization process mediated by an AlSiCu alloy at temperatures as low as 450 °C on top of silicon and polyimide (PI) substrates. The resulting polycrystalline film structure exhibits crystallites with a size of approximately 58 nm, forming polysilicon (poly-Si) grains with diameters between 1–3 µm for Si substrates and 3–7 µm for flexible PI substrates. The mechanical and electrical properties of the poly-Si were experimentally conducted using microfabricated test structures containing piezoresistors formed by poly-Si with different dimensions. The poly-Si material reveals a longitudinal gauge factor (GF) of 12.31 and a transversal GF of −4.90, evaluated using a four-point bending setup. Additionally, the material has a linear temperature coefficient of resistance (TCR) of −2471 ppm/°C. These results illustrate the potential of using this low-temperature film for pressure, force, or temperature sensors. The developed film also demonstrated sensitivity to light, indicating that the developed material can also be explored in photo-sensitive applications. Full article
Show Figures

Figure 1

16 pages, 5828 KB  
Article
Flexible Pressure and Temperature Microsensors for Textile-Integrated Wearables
by Dimitri Emmanuel dos Santos, José Bento Queiroz, Inês Sofia Garcia, João Vieira, José Fernandes, Edoardo Sotgiu, Graça Minas, Maria Bouçanova, Luisa Mendes Arruda, Raul Fangueiro, Anabela Salgueiro-Oliveira, Alar Ainla, Filipe Serra Alves and Rosana Alves Dias
Actuators 2024, 13(1), 42; https://doi.org/10.3390/act13010042 - 20 Jan 2024
Cited by 2 | Viewed by 3590
Abstract
Environmental factors, such as pressure and temperature, are known to contribute to the formation of ulcers that seriously affect bedridden individuals. Researchers have proposed several technologies to achieve the long-term monitoring of those parameters, usually relying on sensing mats, which poses difficulties in [...] Read more.
Environmental factors, such as pressure and temperature, are known to contribute to the formation of ulcers that seriously affect bedridden individuals. Researchers have proposed several technologies to achieve the long-term monitoring of those parameters, usually relying on sensing mats, which poses difficulties in correlating the measurements with specific parts of the body. In this work, we aim to develop microsensors to be integrated into patient clothing. They should be highly flexible, thin with a small footprint, and can be achieved by taking advantage of the microfabrication on polyimide (PI) thin-film substrates (total device thicknesses below 30 µm). Both resistive and capacitance transduction mechanisms were explored, targeting operation ranges of 1 to 40 kPa and 24 to 42 °C. The sensors were integrated into textiles using silicone elastomers and electrical connections based on conductive silver yarn. The experimental characterization showed a nominal capacitance of 21 pF, a sensitivity of −8.44 fF/kPa for the pressure sensors, and a 0.0021 Ω/Ω°C sensitivity of the temperature sensor (with resistance of 29 kΩ at 22 °C). The proposed approach can potentially be implemented not only in wearable devices but also in many other applications for health monitoring or human–machine interfaces. Full article
Show Figures

Figure 1

19 pages, 2692 KB  
Article
Proof of Concept for Sustainable Manufacturing of Neural Electrode Array for In Vivo Recording
by Szu-Ying Li, Hsin-Yi Tseng, Bo-Wei Chen, Yu-Chun Lo, Huai-Hsuan Shao, Yen-Ting Wu, Ssu-Ju Li, Ching-Wen Chang, Ta-Chung Liu, Fu-Yu Hsieh, Yi Yang, Yan-Bo Lai, Po-Chun Chen and You-Yin Chen
Biosensors 2023, 13(2), 280; https://doi.org/10.3390/bios13020280 - 16 Feb 2023
Cited by 3 | Viewed by 4420
Abstract
Increasing requirements for neural implantation are helping to expand our understanding of nervous systems and generate new developmental approaches. It is thanks to advanced semiconductor technologies that we can achieve the high-density complementary metal-oxide-semiconductor electrode array for the improvement of the quantity and [...] Read more.
Increasing requirements for neural implantation are helping to expand our understanding of nervous systems and generate new developmental approaches. It is thanks to advanced semiconductor technologies that we can achieve the high-density complementary metal-oxide-semiconductor electrode array for the improvement of the quantity and quality of neural recordings. Although the microfabricated neural implantable device holds much promise in the biosensing field, there are some significant technological challenges. The most advanced neural implantable device relies on complex semiconductor manufacturing processes, which are required for the use of expensive masks and specific clean room facilities. In addition, these processes based on a conventional photolithography technique are suitable for mass production, which is not applicable for custom-made manufacturing in response to individual experimental requirements. The microfabricated complexity of the implantable neural device is increasing, as is the associated energy consumption, and corresponding emissions of carbon dioxide and other greenhouse gases, resulting in environmental deterioration. Herein, we developed a fabless fabricated process for a neural electrode array that was simple, fast, sustainable, and customizable. An effective strategy to produce conductive patterns as the redistribution layers (RDLs) includes implementing microelectrodes, traces, and bonding pads onto the polyimide (PI) substrate by laser micromachining techniques combined with the drop coating of the silver glue to stack the laser grooving lines. The process of electroplating platinum on the RDLs was performed to increase corresponding conductivity. Sequentially, Parylene C was deposited onto the PI substrate to form the insulation layer for the protection of inner RDLs. Following the deposition of Parylene C, the via holes over microelectrodes and the corresponding probe shape of the neural electrode array was also etched by laser micromachining. To increase the neural recording capability, three-dimensional microelectrodes with a high surface area were formed by electroplating gold. Our eco-electrode array showed reliable electrical characteristics of impedance under harsh cyclic bending conditions of over 90 degrees. For in vivo application, our flexible neural electrode array demonstrated more stable and higher neural recording quality and better biocompatibility as well during the 2-week implantation compared with those of the silicon-based neural electrode array. In this study, our proposed eco-manufacturing process for fabricating the neural electrode array reduced 63 times of carbon emissions compared to the traditional semiconductor manufacturing process and provided freedom in the customized design of the implantable electronic devices as well. Full article
Show Figures

Figure 1

14 pages, 2669 KB  
Article
Hybrid Multisite Silicon Neural Probe with Integrated Flexible Connector for Interchangeable Packaging
by Ashley Novais, Carlos Calaza, José Fernandes, Helder Fonseca, Patricia Monteiro, João Gaspar and Luis Jacinto
Sensors 2021, 21(8), 2605; https://doi.org/10.3390/s21082605 - 8 Apr 2021
Cited by 10 | Viewed by 4595
Abstract
Multisite neural probes are a fundamental tool to study brain function. Hybrid silicon/polymer neural probes combine rigid silicon and flexible polymer parts into one single device and allow, for example, the precise integration of complex probe geometries, such as multishank designs, with flexible [...] Read more.
Multisite neural probes are a fundamental tool to study brain function. Hybrid silicon/polymer neural probes combine rigid silicon and flexible polymer parts into one single device and allow, for example, the precise integration of complex probe geometries, such as multishank designs, with flexible biocompatible cabling. Despite these advantages and benefiting from highly reproducible fabrication methods on both silicon and polymer substrates, they have not been widely available. This paper presents the development, fabrication, characterization, and in vivo electrophysiological assessment of a hybrid multisite multishank silicon probe with a monolithically integrated polyimide flexible interconnect cable. The fabrication process was optimized at wafer level, and several neural probes with 64 gold electrode sites equally distributed along 8 shanks with an integrated 8 µm thick highly flexible polyimide interconnect cable were produced. The monolithic integration of the polyimide cable in the same fabrication process removed the necessity of the postfabrication bonding of the cable to the probe. This is the highest electrode site density and thinnest flexible cable ever reported for a hybrid silicon/polymer probe. Additionally, to avoid the time-consuming bonding of the probe to definitive packaging, the flexible cable was designed to terminate in a connector pad that can mate with commercial zero-insertion force (ZIF) connectors for electronics interfacing. This allows great experimental flexibility because interchangeable packaging can be used according to experimental demands. High-density distributed in vivo electrophysiological recordings were obtained from the hybrid neural probes with low intrinsic noise and high signal-to-noise ratio (SNR). Full article
(This article belongs to the Special Issue State-of-the-Art Sensors Technology in Portugal 2020-2021)
Show Figures

Figure 1

22 pages, 388 KB  
Review
Emerging Encapsulation Technologies for Long-Term Reliability of Microfabricated Implantable Devices
by Seung-Hee Ahn, Joonsoo Jeong and Sung June Kim
Micromachines 2019, 10(8), 508; https://doi.org/10.3390/mi10080508 - 31 Jul 2019
Cited by 80 | Viewed by 7667
Abstract
The development of reliable long-term encapsulation technologies for implantable biomedical devices is of paramount importance for the safe and stable operation of implants in the body over a period of several decades. Conventional technologies based on titanium or ceramic packaging, however, are not [...] Read more.
The development of reliable long-term encapsulation technologies for implantable biomedical devices is of paramount importance for the safe and stable operation of implants in the body over a period of several decades. Conventional technologies based on titanium or ceramic packaging, however, are not suitable for encapsulating microfabricated devices due to their limited scalability, incompatibility with microfabrication processes, and difficulties with miniaturization. A variety of emerging materials have been proposed for encapsulation of microfabricated implants, including thin-film inorganic coatings of Al2O3, HfO2, SiO2, SiC, and diamond, as well as organic polymers of polyimide, parylene, liquid crystal polymer, silicone elastomer, SU-8, and cyclic olefin copolymer. While none of these materials have yet been proven to be as hermetic as conventional metal packages nor widely used in regulatory approved devices for chronic implantation, a number of studies have demonstrated promising outcomes on their long-term encapsulation performance through a multitude of fabrication and testing methodologies. The present review article aims to provide a comprehensive, up-to-date overview of the long-term encapsulation performance of these emerging materials with a specific focus on publications that have quantitatively estimated the lifetime of encapsulation technologies in aqueous environments. Full article
(This article belongs to the Special Issue Implantable Neural Sensors for the Brain Machine Interface)
14 pages, 3095 KB  
Article
Silicon-Based Microfabrication of Free-Floating Neural Probes and Insertion Tool for Chronic Applications
by Andreas Schander, Heiko Stemmann, Andreas K. Kreiter and Walter Lang
Micromachines 2018, 9(3), 131; https://doi.org/10.3390/mi9030131 - 16 Mar 2018
Cited by 15 | Viewed by 7925
Abstract
Bidirectional neural interfaces for multi-channel, high-density recording and electrical stimulation of neural activity in the central nervous system are fundamental tools for neuroscience and medical applications. Especially for clinical use, these electrical interfaces must be stable over several years, which is still a [...] Read more.
Bidirectional neural interfaces for multi-channel, high-density recording and electrical stimulation of neural activity in the central nervous system are fundamental tools for neuroscience and medical applications. Especially for clinical use, these electrical interfaces must be stable over several years, which is still a major challenge due to the foreign body response of neural tissue. A feasible solution to reduce this inflammatory response is to enable a free-floating implantation of high-density, silicon-based neural probes to avoid mechanical coupling between the skull and the cortex during brain micromotion. This paper presents our latest development of a reproducible microfabrication process, which allows a monolithic integration of a highly-flexible, polyimide-based cable with a silicon-stiffened neural probe at a high resolution of 1 µm. For a precise and complete insertion of the free-floating probes into the cortex, a new silicon-based, vacuum-actuated insertion tool is presented, which can be attached to commercially available electrode drives. To reduce the electrode impedance and enable safe and stable microstimulation an additional coating with the electrical conductive polymer PEDOT:PSS is used. The long-term stability of the presented free-floating neural probes is demonstrated in vitro and in vivo. The promising results suggest the feasibility of these neural probes for chronic applications. Full article
(This article belongs to the Special Issue Silicon-based Micro/Nanofabrication for Biomedical Applications)
Show Figures

Figure 1

25 pages, 5530 KB  
Review
Nitride-Based Materials for Flexible MEMS Tactile and Flow Sensors in Robotics
by Claudio Abels, Vincenzo Mariano Mastronardi, Francesco Guido, Tommaso Dattoma, Antonio Qualtieri, William M. Megill, Massimo De Vittorio and Francesco Rizzi
Sensors 2017, 17(5), 1080; https://doi.org/10.3390/s17051080 - 10 May 2017
Cited by 44 | Viewed by 12447
Abstract
The response to different force load ranges and actuation at low energies is of considerable interest for applications of compliant and flexible devices undergoing large deformations. We present a review of technological platforms based on nitride materials (aluminum nitride and silicon nitride) for [...] Read more.
The response to different force load ranges and actuation at low energies is of considerable interest for applications of compliant and flexible devices undergoing large deformations. We present a review of technological platforms based on nitride materials (aluminum nitride and silicon nitride) for the microfabrication of a class of flexible micro-electro-mechanical systems. The approach exploits the material stress differences among the constituent layers of nitride-based (AlN/Mo, Si x N y /Si and AlN/polyimide) mechanical elements in order to create microstructures, such as upwardly-bent cantilever beams and bowed circular membranes. Piezoresistive properties of nichrome strain gauges and direct piezoelectric properties of aluminum nitride can be exploited for mechanical strain/stress detection. Applications in flow and tactile sensing for robotics are described. Full article
(This article belongs to the Special Issue State-of-the-Art Sensors Technologies in Italy 2016)
Show Figures

Figure 1

Back to TopTop