17 pages, 1645 KB  
Communication
Water Event Categorization Using Sub-Metered Water and Coincident Electricity Data
by J. Scott Vitter and Michael Webber
Water 2018, 10(6), 714; https://doi.org/10.3390/w10060714 - 31 May 2018
Cited by 16 | Viewed by 5367
Abstract
This study evaluated the potential for data from dedicated water sub-meters and circuit-level electricity gauges to support accurate water end-use disaggregation tools. A supervised learning algorithm was trained to categorize end-use events from an existing database consisting of features related to whole-home and [...] Read more.
This study evaluated the potential for data from dedicated water sub-meters and circuit-level electricity gauges to support accurate water end-use disaggregation tools. A supervised learning algorithm was trained to categorize end-use events from an existing database consisting of features related to whole-home and hot water use. Additional features were defined based on dedicated irrigation metering and circuit-level electricity gauges on major water appliances. Support vector machine classifiers were trained and tested on portions of the database using multiple feature combinations, and then externally validated on water event data collected under dissimilar conditions from a demonstration house in Austin, Texas, USA. On the testing data, a trained classifier achieved true positive rates for occurrences and volume exceeding 95% for most categories and 93% for toilet events. Performance for faucet events was less than 90%. Initial results suggest that dedicated sub-meters and circuit-level electricity gauges can facilitate highly accurate categorization with simple features that do not rely on flow rate gradients. Full article
(This article belongs to the Section Urban Water Management)
Show Figures

Figure 1

21 pages, 2890 KB  
Article
Water End Use Disaggregation Based on Soft Computing Techniques
by L. Pastor-Jabaloyes, F. J. Arregui and R. Cobacho
Water 2018, 10(1), 46; https://doi.org/10.3390/w10010046 - 9 Jan 2018
Cited by 41 | Viewed by 9605
Abstract
Disaggregating residential water end use events through the available commercial tools needs a great investment in time to manually process smart metering data. Therefore, it is extremely difficult to achieve a homogenous and sufficiently large corpus of classified single-use events capable of accurately [...] Read more.
Disaggregating residential water end use events through the available commercial tools needs a great investment in time to manually process smart metering data. Therefore, it is extremely difficult to achieve a homogenous and sufficiently large corpus of classified single-use events capable of accurately describe residential water consumption. The main goal of the present paper is to develop an automatic tool that facilitates the disaggregation of the individual water consumptions events from the raw flow trace. The proposed disaggregation methodology is conducted through two actions that are iteratively performed: first, the use of an advanced two-step filter, whose calibration is automatically conducted by the Elitist Non-Dominated Sorting Genetic Algorithm NSGA-II; and second, a cropping algorithm based on the filtered water consumption flow traces. As a secondary goal, yet complementary to the main one, a semiautomatic massive classification process has been developed, so that the resulting single-use events can be easily categorized in the different water end uses in a household. This methodology was tested using water consumption data from two different case studies. The characteristics of the households taken as reference and their occupants were unequivocally dissimilar from each other. In addition, the monitoring equipment used to obtain the consumption flow traces had completely different technical specifications. The results obtained from the processing of the two studies show that the automatic disaggregation is both robust and accurate, and produces significant time saving compared to the standard manual analysis. Full article
Show Figures

Figure 1

Back to TopTop