Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (1)

Search Parameters:
Keywords = radiance hood

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
23 pages, 9747 KB  
Article
Influence of the Human Field of View on Visual and Non-Visual Quantities in Indoor Environments
by Johannes Zauner, Kai Broszio and Karin Bieske
Clocks & Sleep 2023, 5(3), 476-498; https://doi.org/10.3390/clockssleep5030032 - 29 Aug 2023
Cited by 15 | Viewed by 6441
Abstract
The visual and non-visual effectiveness of light is often determined by measuring the spectrally weighed irradiance on the corneal plane. This is typically achieved using spectral irradiance or illuminance measurements, captured in a hemispheric (2π) geometry with a diffuser. However, the human binocular [...] Read more.
The visual and non-visual effectiveness of light is often determined by measuring the spectrally weighed irradiance on the corneal plane. This is typically achieved using spectral irradiance or illuminance measurements, captured in a hemispheric (2π) geometry with a diffuser. However, the human binocular field of view (FOV) is not a perfect hemisphere, as it is occluded both upward and downward. Previous research on FOV-restricted measurements is limited, leaving the error from using hemispheric measurements for non-visual quantities undefined. In our study, we tackled this issue by designing and 3D printing FOV occlusions as attachments to spectral measurement devices. We took measurements with and without the occlusion in various laboratory (light from different directions) and real-world lighting situations (light typically from above). Our findings reveal a reduction of visual and melanopic values due to the FOV occlusion. These ranged from negligible to more than 60% in realistic scenarios. Interestingly, the reduction was consistent for both visual and melanopic parameters, as the distribution of light in the FOV was generally spectrally homogeneous. An exception occurred in a specific artificial laboratory situation, where the melanopic daylight (D65) efficacy ratio changed by more than a factor of 2 solely because of the FOV occlusion. Additionally, we observed that head orientation had a marked effect on all quantities measured. In conclusion, our results highlight the potential for substantial errors when solely relying on vertical, hemispheric measurements in experiments and non-visual lighting design projects. We encourage the (additional) use of FOV occlusion in eye-level measurements for typical viewing directions, and we are providing open-source 3D-print files to facilitate this practice. Full article
(This article belongs to the Special Issue Reproducibility in Sleep and Circadian Science)
Show Figures

Graphical abstract

Back to TopTop