20 pages, 3462 KB  
Article
Safety Testing of Endovascular Devices In Vitro for Interventional Neuroradiology Under 0.55 T MRI
by Adèle L. C. Mackowiak, Katerina Eyre, Stanislas Rapacchi, Jean-Baptiste Ledoux, Karolina Swierdzewska, Bruno Bartolini, Francesco Puccinelli, Guillaume Saliou, Matthias Stuber, Christopher W. Roy and Steven D. Hajdu
Neuroimaging 2026, 1(2), 7; https://doi.org/10.3390/neuroimaging1020007 - 2 Apr 2026
Viewed by 850
Abstract
Background/Objectives: MRI-guided neurovascular interventions could benefit from lower-field systems due to reduced magnetic and radiofrequency hazards. However, safety and practical visibility of commonly used neurointerventional devices at 0.55 T remain insufficiently characterized. We evaluated magnetic field interactions, RF-induced heating, and qualitative device [...] Read more.
Background/Objectives: MRI-guided neurovascular interventions could benefit from lower-field systems due to reduced magnetic and radiofrequency hazards. However, safety and practical visibility of commonly used neurointerventional devices at 0.55 T remain insufficiently characterized. We evaluated magnetic field interactions, RF-induced heating, and qualitative device visibility in 11 commercially available and commonly used neurovascular devices on a 0.55 T MRI system. Methods: Eleven devices, including stent retrievers, guidewires, catheters, and one embolization implant, were tested at 0.55 T. Magnetostatic interactions were quantified using the American Society for Testing and Materials (ASTM)-guided deflection methods for translational force (ASTM-F2052) and a two-string suspension apparatus for torque (adapted from Stoianovici et al.). RF-induced heating was measured in an in vitro perfused cerebral vessel phantom using a 15 min high-specific absorption rate spin echo sequence under static and flow conditions. Qualitative device visibility was assessed using a turbo spin echo (TSE) and balanced steady-state free precession (bSSFP) imaging on each device individually. Results: Eight of eleven devices passed the translational force test, while three devices (D, E, and G), containing significant ferromagnetic components, failed with deflection angles > 45°. Eight devices passed torque testing, remaining below the critical threshold in all rotation positions; three devices (D, G, and J) failed by exceeding the 54° criterion, including one guidewire and two devices with braided/coiled metallic structures. Under static conditions, RF-induced heating ranged from negligible to 10.4 °C (maximum in device D) and generally decreased under flow; in the flow configuration, temperature rise remained below 2 °C for 6/11 devices. Qualitative imaging performance differed by sequence, with bSSFP enabling improved delineation of device structure (best for devices A, C, and H), whereas devices D, E, F, and J produced extensive signal voids that precluded reliable visualization in both sequences. Overall, three devices satisfied all safety criteria while remaining clearly visible under MRI. Conclusions: Devices that pass safety thresholds at 0.55 T can serve as candidates for further sequence optimization and preclinical workflow development, enabling the design of low-SAR, device-compatible imaging protocols tailored for neurointerventional workflows. These results provide key safety data supporting the feasibility of MR-guided neurovascular procedures at 0.55 T. Full article
Show Figures

Figure 1

19 pages, 2737 KB  
Article
Image-Based Evaluation of In Vivo Degradation for Shape-Memory Polymer Polyurethane Foam
by Lance M. Graul, Staci J. Horn, Landon D. Nash, Thomas B. Cheung, Fred J. Clubb and Duncan J. Maitland
Polymers 2022, 14(19), 4122; https://doi.org/10.3390/polym14194122 - 1 Oct 2022
Cited by 7 | Viewed by 3070
Abstract
Shape-memory polymer (SMP) polyurethane foams have been applied as embolic devices and implanted in multiple animal models. These materials are oxidatively degradable and it is critical to quantify and characterize the degradation for biocompatibility assessments. An image-based method using high-resolution and magnification scans [...] Read more.
Shape-memory polymer (SMP) polyurethane foams have been applied as embolic devices and implanted in multiple animal models. These materials are oxidatively degradable and it is critical to quantify and characterize the degradation for biocompatibility assessments. An image-based method using high-resolution and magnification scans of histology sections was used to estimate the mass loss of the peripheral and neurovascular embolization devices (PED, NED). Detailed analysis of foam microarchitecture (i.e., struts and membranes) was used to estimate total relative mass loss over time. PED foams implanted in porcine arteries showed a degradation rate of ~0.11% per day as evaluated at 30-, 60-, and 90-day explant timepoints. NED foams implanted in rabbit carotid elastase aneurysms showed a markedly faster rate of degradation at ~1.01% per day, with a clear difference in overall degradation between 30- and 90-day explants. Overall, membranes degraded faster than the struts. NEDs use more hydrophobic foam with a smaller pore size (~150–400 μm) compared to PED foams (~800–1200 μm). Previous in vitro studies indicated differences in the degradation of the two polymer systems, but not to the magnitude seen in vivo. Implant location, animal species, and local tissue health are among the hypothesized reasons for different degradation rates. Full article
(This article belongs to the Section Biobased and Biodegradable Polymers)
Show Figures

Figure 1

20 pages, 6465 KB  
Article
Enhanced X-ray Visibility of Shape Memory Polymer Foam Using Iodine Motifs and Tantalum Microparticles
by Lindy K. Jang, Landon D. Nash, Grace K. Fletcher, Thomas Cheung, Andrew Soewito and Duncan J. Maitland
J. Compos. Sci. 2021, 5(1), 14; https://doi.org/10.3390/jcs5010014 - 6 Jan 2021
Cited by 4 | Viewed by 3880
Abstract
Shape memory polymer (SMP) foams are porous materials with high surface area and large volumetric expansion capabilities that are well suited for endovascular occlusion applications, including brain aneurysm embolization. However, many polyurethane SMP foams are inherently radiolucent when X-ray visibility is required to [...] Read more.
Shape memory polymer (SMP) foams are porous materials with high surface area and large volumetric expansion capabilities that are well suited for endovascular occlusion applications, including brain aneurysm embolization. However, many polyurethane SMP foams are inherently radiolucent when X-ray visibility is required to ensure the safe delivery of the foam to the targeted aneurysm site using fluoroscopy. Here, highly radio-dense tantalum microparticles were added to a previously reported triiodobenzene-containing SMP foam (ATIPA foam) premix to fabricate ATIPA foam-tantalum composites (AT_T). The AT_T foams showed comparable glass transition temperatures, faster expansion profiles, increased X-ray visibility, good cytocompatibility, and faster oxidative degradation compared to the control ATIPA foam without tantalum. The mechanical properties were improved up to 4 vol% tantalum and the X-ray visibility was most appropriate for the 2 vol% (AT_2%T) and 4 vol% (AT_4%T) tantalum foams. E-beam sterilization did not impair the critical properties of the ATIPA foams. Overall, AT_2%T was the optimal foam composition for neurovascular prototypes due to its high oxidative stability in vitro compared to previous low-density SMP foams. The AT_T foams are very promising materials with high toughness and sufficient X-ray visibility for use as neurovascular embolization devices. Full article
(This article belongs to the Special Issue Feature Papers in Journal of Composites Science in 2020)