Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (5)

Search Parameters:
Keywords = mono-energetic neutrons

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
8 pages, 1124 KiB  
Communication
Light Output Function and Pulse-Shape Discrimination Capability of p-Terphenyl Organic Scintillator in Wide Neutron Energy Range of 1.1 to 19 MeV
by Aleš Jančář, Zdeněk Kopecký, Jiří Čulen, Zdeněk Matěj and Michal Košťál
Instruments 2024, 8(4), 46; https://doi.org/10.3390/instruments8040046 - 22 Oct 2024
Viewed by 1154
Abstract
In this work, we studied the light-output properties, efficiency function, as well as the pulse-shape discrimination (PSD) capability of p-Terphenyl scintillator. The selected solid cylindrical scintillation detector has a thickness of 45 mm and a diameter of 45 mm. Recently presented studies of [...] Read more.
In this work, we studied the light-output properties, efficiency function, as well as the pulse-shape discrimination (PSD) capability of p-Terphenyl scintillator. The selected solid cylindrical scintillation detector has a thickness of 45 mm and a diameter of 45 mm. Recently presented studies of light-output functions have only been measured for low-neutron energies. Our motivation has been to determine the light output function for p-Terphenyl scintillator more accurately over a wider neutron energy range. The measurements have been carried out with mono-energetic neutron beams in the wide energy range from 1.1 to 19 MeV. The neutron–gamma spectrometric system which we developed has been used for the measurement. The input analog signal from the detector was digitized with a fast 12-bits analog to digital converter with a sampling frequency of 1 GHz. Measured data from the detector are processed into the gamma and neutron spectra. The accurate light output function for the p-Therphenyl scintillator has been calculated. The pulse-shape discrimination capability, as well as the detection efficiency, of a p-Terphenyl scintillator are lower in comparison with a NE-213 equivalent detector. Full article
Show Figures

Figure 1

20 pages, 868 KiB  
Article
A Double Legendre Polynomial Order N Benchmark Solution for the 1D Monoenergetic Neutron Transport Equation in Plane Geometry
by Barry D. Ganapol
Foundations 2024, 4(3), 422-441; https://doi.org/10.3390/foundations4030027 - 21 Aug 2024
Viewed by 1102
Abstract
As more and more numerical and analytical solutions to the linear neutron transport equation become available, verification of the numerical results becomes increasingly important. This presentation concerns the development of another benchmark for the linear neutron transport equation in a benchmark series, each [...] Read more.
As more and more numerical and analytical solutions to the linear neutron transport equation become available, verification of the numerical results becomes increasingly important. This presentation concerns the development of another benchmark for the linear neutron transport equation in a benchmark series, each employing a different method of solution. In 1D, there are numerous ways of analytically solving the monoenergetic transport equation, such as the Wiener–Hopf method, based on the analyticity of the solution, the method of singular eigenfunctions, inversion of the Laplace and Fourier transform solutions, and analytical discrete ordinates in the limit, which is arguably one of the most straightforward, to name a few. Another potential method is the PN (Legendre polynomial order N) method, where one expands the solution in terms of full-range orthogonal Legendre polynomials, and with orthogonality and series truncation, the moments form an open set of first-order ODEs. Because of the half-range boundary conditions for incoming particles, however, full-range Legendre expansions are inaccurate near material discontinuities. For this reason, a double PN (DPN) expansion in half-range Legendre polynomials is more appropriate, where one separately expands incoming and exiting flux distributions to preserve the discontinuity at material interfaces. Here, we propose and demonstrate a new method of solution for the DPN equations for an isotropically scattering medium. In comparison to a well-established fully analytical response matrix/discrete ordinate solution (RM/DOM) benchmark using an entirely different method of solution for a non-absorbing 1 mfp thick slab with both isotropic and beam sources, the DPN algorithm achieves nearly 8- and 7-place precision, respectively. Full article
Show Figures

Figure 1

25 pages, 1158 KiB  
Article
Towards a Timepix3 Radiation Monitor for the Accelerator Mixed Radiation Field: Characterisation with Protons and Alphas from 0.6 MeV to 5.6 MeV
by Daniel Prelipcean, Giuseppe Lerner, Ivan Slipukhin, David Lucsanyi, Hampus Sandberg, James Storey, Pedro Martin-Holgado, Amor Romero-Maestre, Yolanda Morilla García and Rubén García Alía
Appl. Sci. 2024, 14(2), 624; https://doi.org/10.3390/app14020624 - 11 Jan 2024
Cited by 1 | Viewed by 2069
Abstract
A Timepix3 detector with a 300 μm silicon sensor has been studied as a novel radiation monitor for the mixed radiation field at the Large Hadron Collider at CERN. This work describes a test campaign carried out at Centro Nacional de [...] Read more.
A Timepix3 detector with a 300 μm silicon sensor has been studied as a novel radiation monitor for the mixed radiation field at the Large Hadron Collider at CERN. This work describes a test campaign carried out at Centro Nacional de Aceleradores with quasi-mono energetic protons (alphas) from 0.6 (1) to 5 (5.6) MeV, where orthogonal irradiations are used to obtain an energy calibration, and a low-energy angular scan to estimate the front dead layer thickness of the sensor. The detector is operated in hole collection mode and at a partial bias of 250 μm at 50 V, which increases the charge sharing among pixels to mitigate the signal saturation at high energy depositions. The data, supported by FLUKA Monte Carlo simulations of energy losses in the sensor, show that the Timepix3 monitor operates in a linear regime up to energy depositions of around 600 keV per pixel and 2 MeV per cluster. As a result, the detector has been found to be suitable for measuring charged particle fluxes in the LHC mixed radiation field within the linear calibration regime, with the partial exception of inelastic nuclear reaction hits (mostly from neutrons). Full article
(This article belongs to the Special Issue Advances in Radiation Detection and Monitoring)
Show Figures

Figure 1

7 pages, 373 KiB  
Article
Response to Mono-Energetic Neutrons and Light Output Function for Liquid Organic Scintillators PYR5/DIPN and THIO5/DIPN
by Jaroslav Jánský, Jiří Janda, Michal Košťál, Zdeněk Matěj, Tomáš Bílý, Věra Mazánková, Filip Mravec and František Cvachovec
Quantum Beam Sci. 2022, 6(2), 18; https://doi.org/10.3390/qubs6020018 - 12 May 2022
Cited by 4 | Viewed by 3176
Abstract
Liquid organic scintillators are important devices for measurements of neutron radiation. Currently, large-scale liquid organic scintillators have capabilities of detecting neutrons, but the determination of the neutron energy spectra is a challenge. This work aims to measure the responses of two liquid two-component [...] Read more.
Liquid organic scintillators are important devices for measurements of neutron radiation. Currently, large-scale liquid organic scintillators have capabilities of detecting neutrons, but the determination of the neutron energy spectra is a challenge. This work aims to measure the responses of two liquid two-component scintillators to mono-energetic neutron radiation and to determine their light output function, which is necessary for proper neutron energy spectra determination. Both scintillators are composed of the solvent di-iso-propyl-naphthalene (DIPN) mixed isomers. The first scintillator, labeled PYR5/DIPN, contains the luminophore 1-phenyl-3-(2,4,6-trimethyl-phenyl)-2-pyrazoline with a concentration of 5 g/L. The second scintillator labeled THIO5/DIPN contains the luminophore 2,5-bis(5-tert-butyl-benzoxazol-2-yl)thiophene also with a concentration of 5 g/L. The responses to neutron energies of 1.5 MeV, 2.5 MeV, and 19 MeV are measured at PTB in Braunschweig. The responses to neutron energies of 2.45 MeV and 14 MeV were measured at CTU in Prague using DD and DT reactions. The responses to a silicon filtered beam were measured at Research Centre Řež. The measurements were processed using a two-parameter spectrometric system NGA-01 to discriminate neutrons from gamma rays. The obtained responses are dominated by recoil protons from elastic collisions of neutrons with hydrogen atoms. The edge of the response of recoil protons gives information about the light output of neutrons, compared to gamma rays for the same radiation energy. The light output function for protons in the PYR5/DIPN scintillator is L(Ep)=0.6294Ep1.00(1exp(0.4933Ep0.95)). The light output function for protons in the THIO5/DIPN scintillator is L(Ep)=0.6323Ep1.00(1exp(0.4986Ep0.9883)). The light output functions well resemble the standard shape, and they are quite similar to each other. That suggests a weak influence of the luminophore on the light output function. The light output functions are ready to be incorporated to the response matrix for the neutron energy spectra determination. Full article
(This article belongs to the Special Issue New Trends in Neutron Instrumentation, 2nd Edition)
Show Figures

Figure 1

49 pages, 474 KiB  
Article
The nth-Order Comprehensive Adjoint Sensitivity Analysis Methodology for Response-Coupled Forward/Adjoint Linear Systems (nth-CASAM-L): II. Illustrative Application
by Dan Gabriel Cacuci
Energies 2021, 14(24), 8315; https://doi.org/10.3390/en14248315 - 10 Dec 2021
Cited by 2 | Viewed by 1974
Abstract
This work illustrates the application of the nth-order comprehensive adjoint sensitivity analysis methodology for response-coupled forward/adjoint linear systems (abbreviated as “nth-CASAM-L”) to a paradigm model that describes the transmission of particles (neutrons and/or photons) through homogenized materials, as [...] Read more.
This work illustrates the application of the nth-order comprehensive adjoint sensitivity analysis methodology for response-coupled forward/adjoint linear systems (abbreviated as “nth-CASAM-L”) to a paradigm model that describes the transmission of particles (neutrons and/or photons) through homogenized materials, as encountered in radiation protection and shielding. The first-, second-, and third-order sensitivities of responses that depend on both the forward and adjoint particle fluxes are obtained exactly, in closed-form, underscoring the principles and methodology underlying the nth-CASAM-L. The results presented in this work underscore the fundamentally important role of the nth-CASAM-L in the quest to overcome the “curse of dimensionality” in sensitivity analysis, uncertainty quantification and predictive modeling. Full article
(This article belongs to the Topic Nuclear Energy Systems)
Back to TopTop