Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (4)

Search Parameters:
Keywords = microdroplet tracking

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
15 pages, 4604 KiB  
Article
Development of an Inkjet Setup for Printing and Monitoring Microdroplets
by Beatriz Cavaleiro de Ferreira, Tiago Coutinho, Miguel Ayala Botto and Susana Cardoso
Micromachines 2022, 13(11), 1878; https://doi.org/10.3390/mi13111878 - 31 Oct 2022
Cited by 5 | Viewed by 2470
Abstract
Inkjet printing is a digitally controlled additive technology that allows the precise deposition of droplets. Because it is additive, it enables geometries usually unattainable by other technologies. Because it is digitally controlled, its output is easily modulated, even during operation. Combined with the [...] Read more.
Inkjet printing is a digitally controlled additive technology that allows the precise deposition of droplets. Because it is additive, it enables geometries usually unattainable by other technologies. Because it is digitally controlled, its output is easily modulated, even during operation. Combined with the development of functional materials and their micrometer precision, it can be applicable in a wide range of fields beyond the traditional graphic industry, such as medical diagnosis, electronics manufacturing, and the fabrication of microlenses. In this work, a solution based on open-source hardware and software was implemented instead of choosing a commercial alternative, making the most of inkjet flexibility in terms of inks, substrates, and actuation signal. First, a piezoelectric printhead from MicroFab, driven by an ArduinoDue, was mounted in a 3D printer adapted to ensure precise movement in three dimensions. Then, a monitoring system using a USB digital microscope and a computational algorithm was integrated. Both systems combined allow the printing and measurement of microdroplets by digital regulation of a unipolar signal. Finally, based on a theoretical model and a set of experimentally collected samples, the curve that relates the unipolar signal amplitude to the size of the microdroplets was estimated with an acceptable range of prediction uncertainty. Full article
(This article belongs to the Special Issue Recent Advances in Inkjet Technology)
Show Figures

Figure 1

7 pages, 2749 KiB  
Article
Controlling Microdroplet Inner Rotation by Parallel Carrier Flow of Sesame and Silicone Oils
by Hibiki Yoshimura, Daiki Tanaka, Masahiro Furuya, Tetsushi Sekiguchi and Shuichi Shoji
Micromachines 2022, 13(1), 9; https://doi.org/10.3390/mi13010009 - 22 Dec 2021
Viewed by 2788
Abstract
We developed a method for passively controlling microdroplet rotation, including interior rotation, using a parallel flow comprising silicone and sesame oils. This device has a simple 2D structure with a straight channel and T-junctions fabricated from polydimethylsiloxane. A microdroplet that forms upstream moves [...] Read more.
We developed a method for passively controlling microdroplet rotation, including interior rotation, using a parallel flow comprising silicone and sesame oils. This device has a simple 2D structure with a straight channel and T-junctions fabricated from polydimethylsiloxane. A microdroplet that forms upstream moves into the sesame oil. Then, the largest flow velocity at the interface of the two oil layers applies a rotational force to the microdroplet. A microdroplet in the lower oil rotates clockwise while that in the upper oil rotates anti-clockwise. The rotational direction was controlled by a simple combination of sesame and silicone oils. Droplet interior flow was visualized by tracking microbeads inside the microdroplets. This study will contribute to the efficient creation of chiral molecules for pharmaceutical and materials development by controlling rotational direction and speed. Full article
(This article belongs to the Section E:Engineering and Technology)
Show Figures

Figure 1

14 pages, 4861 KiB  
Article
Technique and Circuit for Contactless Readout of Piezoelectric MEMS Resonator Sensors
by Marco Baù, Marco Ferrari, Habiba Begum, Abid Ali, Joshua E.-Y. Lee and Vittorio Ferrari
Sensors 2020, 20(12), 3483; https://doi.org/10.3390/s20123483 - 19 Jun 2020
Cited by 6 | Viewed by 4673
Abstract
A technique and electronic circuit for contactless electromagnetic interrogation of piezoelectric micro-electromechanical system (MEMS) resonator sensors are proposed. The adopted resonator is an aluminum-nitride (AlN) thin-film piezoelectric-on-silicon (TPoS) disk vibrating in radial contour mode at about 6.3 MHz. The MEMS resonator is operated [...] Read more.
A technique and electronic circuit for contactless electromagnetic interrogation of piezoelectric micro-electromechanical system (MEMS) resonator sensors are proposed. The adopted resonator is an aluminum-nitride (AlN) thin-film piezoelectric-on-silicon (TPoS) disk vibrating in radial contour mode at about 6.3 MHz. The MEMS resonator is operated in one-port configuration and it is connected to a spiral coil, forming the sensor unit. A proximate electronic interrogation unit is electromagnetically coupled through a readout coil to the sensor unit. The proposed technique exploits interleaved excitation and detection phases of the MEMS resonator. A tailored electronic circuit manages the periodic switching between the excitation phase, where it generates the excitation signal driving the readout coil, and the detection phase, where it senses the transient decaying response of the resonator by measuring through a high-impedance amplifier the voltage induced back across the readout coil. This approach advantageously ensures that the readout frequency of the MEMS resonator is first order independent of the interrogation distance between the readout and sensor coils. The reported experimental results show successful contactless readout of the MEMS resonator independently from the interrogation distance over a range of 12 mm, and the application as a resonant sensor for ambient temperature and as a resonant acoustic-load sensor to detect and track the deposition and evaporation processes of water microdroplets on the MEMS resonator surface. Full article
(This article belongs to the Special Issue Feature Papers in Physical Sensors Section 2020)
Show Figures

Figure 1

23 pages, 27810 KiB  
Review
A Review of Planar PIV Systems and Image Processing Tools for Lab-On-Chip Microfluidics
by Fahrettin Gökhan Ergin, Bo Beltoft Watz and Nicolai Fog Gade-Nielsen
Sensors 2018, 18(9), 3090; https://doi.org/10.3390/s18093090 - 13 Sep 2018
Cited by 24 | Viewed by 9603
Abstract
Image-based sensor systems are quite popular in micro-scale flow investigations due to their flexibility and scalability. The aim of this manuscript is to provide an overview of current technical possibilities for Particle Image Velocimetry (PIV) systems and related image processing tools used in [...] Read more.
Image-based sensor systems are quite popular in micro-scale flow investigations due to their flexibility and scalability. The aim of this manuscript is to provide an overview of current technical possibilities for Particle Image Velocimetry (PIV) systems and related image processing tools used in microfluidics applications. In general, the PIV systems and related image processing tools can be used in a myriad of applications, including (but not limited to): Mixing of chemicals, droplet formation, drug delivery, cell counting, cell sorting, cell locomotion, object detection, and object tracking. The intention is to provide some application examples to demonstrate the use of image processing solutions to overcome certain challenges encountered in microfluidics. These solutions are often in the form of image pre- and post-processing techniques, and how to use these will be described briefly in order to extract the relevant information from the raw images. In particular, three main application areas are covered: Micro mixing, droplet formation, and flow around microscopic objects. For each application, a flow field investigation is performed using Micro-Particle Image Velocimetry (µPIV). Both two-component (2C) and three-component (3C) µPIV systems are used to generate the reported results, and a brief description of these systems are included. The results include detailed velocity, concentration and interface measurements for micromixers, phase-separated velocity measurements for the micro-droplet generator, and time-resolved (TR) position, velocity and flow fields around swimming objects. Recommendations on, which technique is more suitable in a given situation are also provided. Full article
(This article belongs to the Special Issue Lab-on-a-Chip–From Point of Care to Precision Medicine)
Show Figures

Figure 1

Back to TopTop