Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (8)

Search Parameters:
Keywords = dishwasher pump

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
16 pages, 10446 KiB  
Article
Transient Vortex Dynamics in Tip Clearance Flow of a Novel Dishwasher Pump
by Chao Ning, Yalin Li, Haichao Sun, Yue Wang and Fan Meng
Machines 2025, 13(8), 681; https://doi.org/10.3390/machines13080681 - 2 Aug 2025
Viewed by 189
Abstract
Blade tip leakage vortex (TLV) is a critical phenomenon in hydraulic machinery, which can significantly affect the internal flow characteristics and deteriorate the hydraulic performance. In this paper, the blade tip leakage flow and TLV characteristics in a novel dishwasher pump were investigated. [...] Read more.
Blade tip leakage vortex (TLV) is a critical phenomenon in hydraulic machinery, which can significantly affect the internal flow characteristics and deteriorate the hydraulic performance. In this paper, the blade tip leakage flow and TLV characteristics in a novel dishwasher pump were investigated. The correlation between the vorticity distribution in various directions and the leakage vortices was established within a rotating coordinate system. The results show that the TLV in a composite impeller can be categorized into initial and secondary leakage vortices. The initial leakage vortex originates from the evolution of two corner vortices that initially form at different locations within the blade tip clearance. This vortex induces pressure fluctuations at the impeller inlet; its shedding is identified as the primary contributor to localized energy loss within the flow passage. These findings provide insights into TLVs in complex pump geometries and provide solutions for future pump optimization strategies. Full article
Show Figures

Figure 1

16 pages, 5050 KiB  
Article
A Field Study of Nonintrusive Load Monitoring Devices and Implications for Load Disaggregation
by Ebony Mayhorn, Joshua Butzbaugh and Alan Meier
Sensors 2023, 23(19), 8253; https://doi.org/10.3390/s23198253 - 5 Oct 2023
Cited by 2 | Viewed by 1802
Abstract
Evaluations of nonintrusive load monitoring (NILM) algorithms and technologies have mostly occurred in constrained, artificial environments. However, few field evaluations of NILM products have taken place in actual buildings under normal operating conditions. This paper describes a field evaluation of a state-of-the-art NILM [...] Read more.
Evaluations of nonintrusive load monitoring (NILM) algorithms and technologies have mostly occurred in constrained, artificial environments. However, few field evaluations of NILM products have taken place in actual buildings under normal operating conditions. This paper describes a field evaluation of a state-of-the-art NILM product, tested in eight homes. The match rate metric—a technique recommended by a technical advisory group—was used to measure the NILM’s success in identifying specific loads and the accuracy of the energy consumption estimates. A performance assessment protocol was also developed to address common issues with NILM mislabeling and ground-truth comparisons that have not been sufficiently addressed in past evaluations. The NILM product’s estimates were compared to the submetered consumption of eight major appliances. Overall, the product had good performance in disaggregating the energy consumption of the electric water heaters, which included both electric resistance and heat-pump water heaters, but only a fair accuracy with refrigerators, dryers, and air conditioners. The performance was poor for cooking equipment, furnace fans, clothes washers, and dishwashers. Moreover, the product was often unable to detect major loads in homes. Typically, two or more appliances were not detected in a home. At least two dryers, furnace fans, and air conditioners went undetected across the eight homes. On the other hand, the dishwasher was detected in all homes where available or monitored. The key findings were qualitatively compared to those of past field evaluations. Potential areas for improvement in NILM product performance were determined along with areas where complementary technologies may be able to aid in load-disaggregation applications. Full article
Show Figures

Figure 1

16 pages, 1581 KiB  
Article
Deep Adaptive Ensemble Filter for Non-Intrusive Residential Load Monitoring
by Nasrin Kianpoor, Bjarte Hoff and Trond Østrem
Sensors 2023, 23(4), 1992; https://doi.org/10.3390/s23041992 - 10 Feb 2023
Cited by 4 | Viewed by 1778
Abstract
Identifying flexible loads, such as a heat pump, has an essential role in a home energy management system. In this study, an adaptive ensemble filtering framework integrated with long short-term memory (LSTM) is proposed for identifying flexible loads. The proposed framework, called AEFLSTM, [...] Read more.
Identifying flexible loads, such as a heat pump, has an essential role in a home energy management system. In this study, an adaptive ensemble filtering framework integrated with long short-term memory (LSTM) is proposed for identifying flexible loads. The proposed framework, called AEFLSTM, takes advantage of filtering techniques and the representational power of LSTM for load disaggregation by filtering noise from the total power and learning the long-term dependencies of flexible loads. Furthermore, the proposed framework is adaptive and searches ensemble filtering techniques, including discrete wavelet transform, low-pass filter, and seasonality decomposition, to find the best filtering method for disaggregating different flexible loads (e.g., heat pumps). Experimental results are presented for estimating the electricity consumption of a heat pump, a refrigerator, and a dishwasher from the total power of a residential house in British Columbia (a publicly available use case). The results show that AEFLSTM can reduce the loss error (mean absolute error) by 57.4%, 44%, and 55.5% for estimating the power consumption of the heat pump, refrigerator, and dishwasher, respectively, compared to the stand-alone LSTM model. The proposed approach is used for another dataset containing measurements of an electric vehicle to further support the validity of the method. AEFLSTM is able to improve the result for disaggregating an electric vehicle by 22.5%. Full article
Show Figures

Figure 1

20 pages, 8592 KiB  
Article
Parametric Analysis and Optimization Design of the Twin-Volute for a New Type of Dishwasher Pump
by Haichao Sun, Hui Xu, Yanjun Li, Xikun Wang and Yalin Li
Processes 2023, 11(2), 305; https://doi.org/10.3390/pr11020305 - 17 Jan 2023
Cited by 2 | Viewed by 2087
Abstract
To improve the hydraulic performance of a new type of dishwasher pump and solve the multi-parameter optimization problem, a genetic algorithm was introduced to optimize the special design of the twin-volute structure. Six curvature radii of the twin-volute structure were defined as the [...] Read more.
To improve the hydraulic performance of a new type of dishwasher pump and solve the multi-parameter optimization problem, a genetic algorithm was introduced to optimize the special design of the twin-volute structure. Six curvature radii of the twin-volute structure were defined as the optimization parameters, and 100 groups of design samples were generated based on the Latin hypercube sampling (LHS) method. The pump head and the efficiency were taken as the optimization objectives, i.e., to improve the efficiency as much as possible while ensuring that the head would not be lower than 2 m. The important parameters were identified via sensitivity analysis, and the optimization problem was solved in detail by using the multi-objective genetic algorithm (MOGA). The results showed that the external profile of the first to the fourth section of the twin-volute structure had the most significant effect on the pump head and efficiency. The response surface method (RSM) was used to select the intervals of optimization, and a comparative simulation of the pump schemes before and after optimization was performed. The head curve did not significantly change before and after optimization. By contrast, the efficiency of the dishwasher pump significantly increased, showing an increase of 2.7% under the design point. Compared with the original model, the impeller of the optimal model pump had a lower overall distribution of turbulent kinetic energy, reduced the vorticity in the twin-volute inlet area, and increased the pressure in the flow channel. Our research results confirm that the combination of RSM and MOGA can effectively solve the problem of optimization for new types of dishwashers and can provide a reference for the development of subsequent hydraulic models. Full article
(This article belongs to the Special Issue Design and Optimization Method of Pumps)
Show Figures

Figure 1

21 pages, 8567 KiB  
Article
Orthogonal Optimization Design of the Compound Impeller for a New Type of Dishwasher Pump
by Yanjun Li, Haichao Sun, Hui Xu, Xikun Wang and Yalin Li
Processes 2022, 10(9), 1813; https://doi.org/10.3390/pr10091813 - 8 Sep 2022
Cited by 3 | Viewed by 2653
Abstract
A new type of dishwasher pump without a pipeline system was invented for the first time to form an original sink-type dishwasher avoiding the accumulation of dirt in the hydraulic system. In order to improve the hydraulic performance of this new type of [...] Read more.
A new type of dishwasher pump without a pipeline system was invented for the first time to form an original sink-type dishwasher avoiding the accumulation of dirt in the hydraulic system. In order to improve the hydraulic performance of this new type of dishwasher pump with twin-volute passive rotation driven by a compound impeller, an orthogonal optimal design method was first introduced to optimize the compound impeller composed of axial cascades and radial blades. Six geometric parameters were selected as the main factors to design the orthogonal table L18(36). All impeller models were manufactured via high-precision 3D printing and tested to determine the optimal solution. Firstly, the hydraulic performance was measured using a specially designed test bench under the assumption of static-volute conditions. Then, the optimization scheme was verified in real machine experiments under the rotating-volute condition, and numerical calculations were used to assess the performance improvement due to optimization under the static- and rotating-volute conditions. The results show that the main factors affecting the pump head and efficiency are impeller outlet diameter D2 and profile line L. The optimized pump head and efficiency are significantly higher than those of the original scheme. Furthermore, the entropy production of each flow passage component of this new type of dishwasher pump is significantly reduced after optimization. Under the static-volute condition, the scheme obtained using the range analysis displays an increase of 0.3 m in the pump head and 2.99% in pump efficiency. Under the rotating-volute condition, the optimization scheme is also effective (pump head increased by 0.54 m, and pump efficiency by 7.46%). At the same time, the passive rotation speed of the twin-volute increases from 60 rpm to 70 rpm, verifying that both the optimization method is reliable and can be used when developing and optimizing dishwasher pumps. Full article
(This article belongs to the Special Issue Design and Optimization Method of Pumps)
Show Figures

Figure 1

15 pages, 6520 KiB  
Article
Experimental Investigation of Unsteady Pressure Pulsation in New Type Dishwasher Pump with Special Double-Tongue Volute
by Yilei Zhu, Jinfeng Zhang, Yalin Li, Ping Huang, Hui Xu and Feng Zheng
Machines 2021, 9(11), 288; https://doi.org/10.3390/machines9110288 - 14 Nov 2021
Cited by 5 | Viewed by 2632
Abstract
A pressure pulsation experiment of a dishwasher pump with a passive rotation double-tongue volute was carried out and compared with the pressure pulsation of a single-tongue volute and a static double-tongue volute. The pressure pulsation of the three volute models was compared and [...] Read more.
A pressure pulsation experiment of a dishwasher pump with a passive rotation double-tongue volute was carried out and compared with the pressure pulsation of a single-tongue volute and a static double-tongue volute. The pressure pulsation of the three volute models was compared and analyzed from two aspects of different impeller speeds and different monitoring points. The frequency domain and time–frequency domain of pressure pulsation were obtained by a Fourier transform and short-time Fourier transform, respectively. The results showed that the average pressure of each monitoring point on the rotating double-tongue volute was the smallest and that on the single-tongue volute was the largest. When the impeller rotates at 3000 rpm, there were eight peaks and valleys in the pressure pulsation time domain curve of the single-tongue volute, while the double-tongue volute was twice that of the single-tongue volute. Under different impeller speeds, the changing trends of pressure pulsation time and frequency domain curves of static and rotating double-tongue volutes at monitoring point p1 are basically the same. Therefore, a volute reference scheme with passive rotation speed is proposed in this study, which can effectively improve the flow pattern and reduce pressure inside the dishwasher pump, and also provide a new idea for rotor–rotor interference to guide the innovation of dishwashers. Full article
(This article belongs to the Special Issue Optimization and Flow Characteristics in Advanced Fluid Machinery)
Show Figures

Figure 1

14 pages, 1165 KiB  
Data Descriptor
Residential Power Traces for Five Houses: The iHomeLab RAPT Dataset
by Patrick Huber, Melvin Ott, Martin Friedli, Andreas Rumsch and Andrew Paice
Data 2020, 5(1), 17; https://doi.org/10.3390/data5010017 - 5 Feb 2020
Cited by 15 | Viewed by 4705
Abstract
Datasets with measurements of both solar electricity production and domestic electricity consumption separated into the major loads are interesting for research focussing on (i) local optimization of solar energy consumption and (ii) non-intrusive load monitoring. To this end, we publish the iHomeLab RAPT [...] Read more.
Datasets with measurements of both solar electricity production and domestic electricity consumption separated into the major loads are interesting for research focussing on (i) local optimization of solar energy consumption and (ii) non-intrusive load monitoring. To this end, we publish the iHomeLab RAPT dataset consisting of electrical power traces from five houses in the greater Lucerne region in Switzerland spanning a period from 1.5 up to 3.5 years with a sampling frequency of five minutes. For each house, the electrical energy consumption of the aggregated household and specific appliances such as dishwasher, washing machine, tumble dryer, hot water boiler, or heating pump were metered. Additionally, the data includes electric production data from PV panels for all five houses, and battery power flow measurement data from two houses. Thermal metadata is also provided for the three houses with a heating pump. Full article
Show Figures

Figure 1

20 pages, 5918 KiB  
Article
A Heuristic Home Electric Energy Management System Considering Renewable Energy Availability
by Victor J. Gutierrez-Martinez, Carlos A. Moreno-Bautista, Jose M. Lozano-Garcia, Alejandro Pizano-Martinez, Enrique A. Zamora-Cardenas and Miguel A. Gomez-Martinez
Energies 2019, 12(4), 671; https://doi.org/10.3390/en12040671 - 19 Feb 2019
Cited by 23 | Viewed by 4328
Abstract
This paper presents the development of a heuristic-based algorithm for a Home Electric Energy Management System (HEEMS). The novelty of the proposal resides in the fact that solutions of the Pareto front, minimizing both the energy consumption and cost, are obtained by a [...] Read more.
This paper presents the development of a heuristic-based algorithm for a Home Electric Energy Management System (HEEMS). The novelty of the proposal resides in the fact that solutions of the Pareto front, minimizing both the energy consumption and cost, are obtained by a Genetic Algorithm (GA) considering the renewable energy availability as well as the user activity level (AL) inside the house. The extensive solutions search characteristic of the GAs is seized to avoid the calculation of the full set of Pareto front solutions, i.e., from a reduced set of non-dominated solutions in the Pareto sense, an optimal solution with the best fitness is obtained, reducing considerably the computational time. The HEEMS considers models of the air conditioner, clothes dryer, dishwasher, electric stove, pool pump, and washing machine. Models of the wind turbine and solar PV modules are also included. The wind turbine model is written in terms of the generated active power exclusively dependent on the incoming wind profiles. The solar PV modules model accounts for environmental factors such as ambient temperature changes and irradiance profiles. The effect of the energy storage unit on the energy consumption and costs is evaluated adapting a model of the device considering its charge and discharge ramp rates. The proposed algorithm is implemented in the Matlab® platform and its validation is performed by comparing its results to those obtained by a freeware tool developed for the energy management of smart residential loads. Also, the evaluation of the performance of the proposed HEEMS is carried out by comparing its results to those obtained when the multi-objective optimization problem is solved considering weights assigned to each objective function. Results showed that considerable savings are obtained at reduced computational times. Furthermore, with the calculation of only one solution, the end-user interaction is reduced making the HEEMS even more manageable than previously proposed approaches. Full article
(This article belongs to the Special Issue Smart Energy Management for Smart Grids 2019)
Show Figures

Figure 1

Back to TopTop