Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (6)

Search Parameters:
Keywords = core-shell bead assay

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
14 pages, 26561 KiB  
Article
Fe3O4@PDA@PEI Core-Shell Microspheres as a Novel Magnetic Sorbent for the Rapid and Broad-Spectrum Separation of Bacteria in Liquid Phase
by Yueqi Zhang, Bin Du, Yuting Wu, Zhiwei Liu, Jiang Wang, Jianjie Xu, Zhaoyang Tong, Xihui Mu and Bing Liu
Materials 2022, 15(6), 2039; https://doi.org/10.3390/ma15062039 - 10 Mar 2022
Cited by 17 | Viewed by 3414
Abstract
Bacterial infection is a significant cause of morbidity and mortality to humans worldwide. Thus, a method for nonspecific, sensitive, and rapid enrichment of such bacteria is essential for bacteria detection and treatment. This study demonstrates a self-made core-shell Fe3O4@Polydopamine@Polyethyleneimine [...] Read more.
Bacterial infection is a significant cause of morbidity and mortality to humans worldwide. Thus, a method for nonspecific, sensitive, and rapid enrichment of such bacteria is essential for bacteria detection and treatment. This study demonstrates a self-made core-shell Fe3O4@Polydopamine@Polyethyleneimine magnetic beads (Fe3O4@PDA@PEI MBs) with a high density positive charge-based magnetic separation scheme for the broad-spectrum rapid enrichment of microorganisms in the liquid phase. MBs with a high-density positive charge have a strong electrostatic attraction to most microorganisms in nature. Our scheme is as follows: (1) wrapping dopamine (DA) on the iron oxide through self-polymerization and wrapping PEI on the outermost shell layer in a mode of crosslinking with the PDA; (2) subsequently, the Fe3O4@PDA@PEI MBs were used to concentrate microorganisms from the sample solution; (3) performing magnetic separation and calculating the adsorption efficiency. The as-prepared Fe3O4@PDA@PEI MBs composite was carefully characterized by zeta potential analysis, Value stream-mapping (VSM), transmission electron microscopy (TEM), and Fourier transforms infrared spectrometry (FT-IR). In this study, both gram-positive and gram-negative bacteria could be captured in three minutes through electrostatic interaction. Furthermore, the adsorption efficiency on gram-negative (>98%) is higher than that on gram-positive (>95%), allowing for a simple, rapid assay to enrich organisms in resource-limited settings. Full article
(This article belongs to the Topic Advances in Biomaterials)
Show Figures

Figure 1

11 pages, 1458 KiB  
Article
Coaxial Electrospun PLLA Fibers Modified with Water-Soluble Materials for Oligodendrocyte Myelination
by Zhepeng Liu, Jing Wang, Haini Chen, Guanyu Zhang, Zhuman Lv, Yijun Li, Shoujin Zhao and Wenlin Li
Polymers 2021, 13(20), 3595; https://doi.org/10.3390/polym13203595 - 19 Oct 2021
Cited by 4 | Viewed by 2787
Abstract
Myelin sheaths are essential in maintaining the integrity of axons. Development of the platform for in vitro myelination would be especially useful for demyelinating disease modeling and drug screening. In this study, a fiber scaffold with a core–shell structure was prepared in one [...] Read more.
Myelin sheaths are essential in maintaining the integrity of axons. Development of the platform for in vitro myelination would be especially useful for demyelinating disease modeling and drug screening. In this study, a fiber scaffold with a core–shell structure was prepared in one step by the coaxial electrospinning method. A high-molecular-weight polymer poly-L-lactic acid (PLLA) was used as the core, while the shell was a natural polymer material such as hyaluronic acid (HA), sodium alginate (SA), or chitosan (CS). The morphology, differential scanning calorimetry (DSC), Fourier transform infrared spectra (FTIR), contact angle, viability assay, and in vitro myelination by oligodendrocytes were characterized. The results showed that such fibers are bead-free and continuous, with an average size from 294 ± 53 to 390 ± 54 nm. The DSC and FTIR curves indicated no changes in the phase state of coaxial brackets. Hyaluronic acid/PLLA coaxial fibers had the minimum contact angle (53.1° ± 0.24°). Myelin sheaths were wrapped around a coaxial electrospun scaffold modified with water-soluble materials after a 14-day incubation. All results suggest that such a scaffold prepared by coaxial electrospinning potentially provides a novel platform for oligodendrocyte myelination. Full article
(This article belongs to the Special Issue Polymer Materials in Biomedical Application)
Show Figures

Figure 1

11 pages, 2168 KiB  
Article
Loop-Mediated Isothermal Amplification in a Core-Shell Bead Assay for the Detection of Tyrosine Kinase AXL Overexpression
by Kamalalayam Rajan Sreejith, Muhammad Umer, Pradip Singha, Nhat-Khuong Nguyen, Surasak Kasetsirikul, Chin Hong Ooi, Muhammad J. A. Shiddiky and Nam-Trung Nguyen
Micromachines 2021, 12(8), 905; https://doi.org/10.3390/mi12080905 - 30 Jul 2021
Cited by 5 | Viewed by 3357
Abstract
The upregulated expression of tyrosine kinase AXL has been reported in several hematologic and solid human tumors, including gastric, breast, colorectal, prostate and ovarian cancers. Thus, AXL can potentially serve as a diagnostic and prognostic biomarker for various cancers. This paper reports the [...] Read more.
The upregulated expression of tyrosine kinase AXL has been reported in several hematologic and solid human tumors, including gastric, breast, colorectal, prostate and ovarian cancers. Thus, AXL can potentially serve as a diagnostic and prognostic biomarker for various cancers. This paper reports the first ever loop-mediated isothermal amplification (LAMP) in a core-shell bead assay for the detection of AXL gene overexpression. We demonstrated simple instrumentation toward a point-of-care device to perform LAMP. This paper also reports the first ever use of core-shell beads as a microreactor to perform LAMP as an attempt to promote environmentally-friendly laboratory practices. Full article
(This article belongs to the Special Issue Feature Papers of Micromachines in Biology and Biomedicine 2021)
Show Figures

Figure 1

13 pages, 2522 KiB  
Article
Controlled Release of Metformin Hydrochloride from Core-Shell Nanofibers with Fish Sarcoplasmic Protein
by Su Sena, Korkmaz Nalan Sumeyra, Guven Ulkugul, Arslan Sema, Karademir Betul, Sennaroglu Bostan Muge, Eroglu Mehmet Sayip, Uzun Muhammet, Kalkandelen Cevriye, Mahirogullari Mahir, Mihail Aurel Titu, Denisa Ficai, Anton Ficai and Oguzhan Gunduz
Medicina 2019, 55(10), 682; https://doi.org/10.3390/medicina55100682 - 10 Oct 2019
Cited by 25 | Viewed by 4005
Abstract
Background and Objectives: A coaxial electrospinning technique was used to produce core/shell nanofibers of a polylactic acid (PLA) as a shell and a polyvinyl alcohol (PVA) containing metformin hydrochloride (MH) as a core. Materials and Methods: Fish sarcoplasmic protein (FSP) was [...] Read more.
Background and Objectives: A coaxial electrospinning technique was used to produce core/shell nanofibers of a polylactic acid (PLA) as a shell and a polyvinyl alcohol (PVA) containing metformin hydrochloride (MH) as a core. Materials and Methods: Fish sarcoplasmic protein (FSP) was extracted from fresh bonito and incorporated into nanofiber at various concentrations to investigate the influence on properties of the coaxial nanofibers. The morphology, chemical structure and thermal properties of the nanofibers were studied. Results: The results show that uniform and bead-free structured nanofibers with diameters ranging from 621 nm to 681 nm were obtained. A differential scanning calorimetry (DSC) analysis shows that FSP had a reducing effect on the crystallinity of the nanofibers. Furthermore, the drug release profile of electrospun fibers was analyzed using the spectrophotometric method. Conclusions: The nanofibers showed prolonged and sustained release and the first order kinetic seems to be more suitable to describe the release. MTT assay suggests that the produced drug and protein loaded coaxial nanofibers are non-toxic and enhance cell attachment. Thus, these results demonstrate that the produced nanofibers had the potential to be used for diabetic wound healing applications. Full article
(This article belongs to the Special Issue Nano-Biosciences in the Field of Health-Care)
Show Figures

Figure 1

23 pages, 2664 KiB  
Review
Bioengineering Microgels and Hydrogel Microparticles for Sensing Biomolecular Targets
by Edmondo Battista, Filippo Causa and Paolo Antonio Netti
Gels 2017, 3(2), 20; https://doi.org/10.3390/gels3020020 - 30 May 2017
Cited by 23 | Viewed by 10036
Abstract
Hydrogels, and in particular microgels, are playing an increasingly important role in a diverse range of applications due to their hydrophilic, biocompatible, and highly flexible chemical characteristics. On this basis, solution-like environment, non-fouling nature, easy probe accessibility and target diffusion, effective inclusion of [...] Read more.
Hydrogels, and in particular microgels, are playing an increasingly important role in a diverse range of applications due to their hydrophilic, biocompatible, and highly flexible chemical characteristics. On this basis, solution-like environment, non-fouling nature, easy probe accessibility and target diffusion, effective inclusion of reporting moieties can be achieved, making them ideal substrates for bio-sensing applications. In fact, hydrogels are already successfully used in immunoassays as well as sensitive nucleic acid assays, also enabling hydrogel-based suspension arrays. In this review, we discuss key parameters of hydrogels in the form of micron-sized particles to be used in sensing applications, paying attention to the protein and oligonucleotides (i.e., miRNAs) targets as most representative kind of biomarkers. Full article
(This article belongs to the Special Issue Micro- and Nanogels)
Show Figures

Graphical abstract

14 pages, 785 KiB  
Article
A Sandwich Electrochemical Immunosensor Using Magnetic DNA Nanoprobes for Carcinoembryonic Antigen
by Ning Gan, Liyong Jia and Lei Zheng
Int. J. Mol. Sci. 2011, 12(11), 7410-7423; https://doi.org/10.3390/ijms12117410 - 28 Oct 2011
Cited by 41 | Viewed by 9076
Abstract
A novel magnetic nanoparticle-based electrochemical immunoassay of carcinoembryonic antigen (CEA) was designed as a model using CEA antibody-functionalized magnetic beads [DNA/Fe3O4/ZrO2; Fe3O4 (core)/ZrO2 (shell) nano particles (ZMPs)] as immunosensing probes. To design the [...] Read more.
A novel magnetic nanoparticle-based electrochemical immunoassay of carcinoembryonic antigen (CEA) was designed as a model using CEA antibody-functionalized magnetic beads [DNA/Fe3O4/ZrO2; Fe3O4 (core)/ZrO2 (shell) nano particles (ZMPs)] as immunosensing probes. To design the immunoassay, the CEA antibody and O-phenylenediamine (OPD) were initially immobilized on a chitosan/nano gold composite membrane on a glassy carbon electrode (GCE/CS-nano Au), which was used for CEA recognition. Then, horseradish peroxidase (HRP)-labeled anti-CEA antibodies (HRP-CEA Ab2) were bound to the surface of the synthesized magnetic ZMP nanoparticles as signal tag. Thus, the sandwich-type immune complex could be formed between secondary antibody (Ab2) modified DNA/ZMPs nanochains tagged by HRP and GCE/CS-nano Au. Unlike conventional nanoparticle-based electrochemical immunoassays, the recognition elements of this immunoassay included both electron mediators and enzyme labels, which obviously simplifies the electrochemical measurement process. The sandwich-type immunoassay format was used for online formation of the immunocomplex of CEA captured in the detection cell with an external magnet. The electrochemical signals derived from HRP during the reduction of H2O2 with OPD as electron mediator were measured. The method displayed a high sensitivity for CEA detection in the range of 0.008–200 ng/mL, with a detection limit of 5 pg/mL (estimated at a signal-to-noise ratio of 3). The precision, reproducibility, and stability of the immunoassay were good. The use of the assay was evaluated with clinical serum samples, and the results were in excellent accordance with those obtained using the standard enzyme-linked immunosorbent assay (ELISA) method. Thus, the magnetic nanoparticle-based assay format is a promising approach for clinical applications, and it could be further developed for the detection of other biomarkers in cancer diagnosis. Full article
(This article belongs to the Section Materials Science)
Show Figures

Back to TopTop