Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (5)

Search Parameters:
Keywords = capacitive electrocardiography (cECG)

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
44 pages, 18981 KB  
Article
Improving Signal Quality in Non-Contact Electrocardiography: Novel Strategy for Motion Artifact Reduction
by Antonio Stanešić, Luka Klaić, Dino Cindrić and Mario Cifrek
Sensors 2026, 26(12), 3643; https://doi.org/10.3390/s26123643 - 7 Jun 2026
Viewed by 498
Abstract
Capacitive electrocardiography (cECG) enables non-contact heart rate monitoring through clothing, but motion artifacts remain a critical limitation for practical applications. We present a novel motion artifact removal method using non-contact floating electrodes as noise references combined with multi-reference Normalized Least Mean Squares (NLMS) [...] Read more.
Capacitive electrocardiography (cECG) enables non-contact heart rate monitoring through clothing, but motion artifacts remain a critical limitation for practical applications. We present a novel motion artifact removal method using non-contact floating electrodes as noise references combined with multi-reference Normalized Least Mean Squares (NLMS) adaptive filtering. The floating electrodes, positioned without skin contact, couple primarily to ambient 50 Hz mains interference, which becomes amplitude-modulated during motion due to changes in electrode–body capacitance. Six reference signals are derived from this noise electrode: band-pass-filtered signal and its derivative (capturing baseline-type artifacts), envelope and its derivative (capturing amplitude modulation patterns), and envelope asymmetry and its derivative (capturing non-linear electrode response during motion). The NLMS algorithm adaptively combines these references to estimate and remove motion artifacts while preserving QRS morphology through low-pass filtering of the correction signal. A hysteresis-based motion detector with minimum duration constraints enables selective application of artifact removal only during motion periods, leaving rest-period ECG unmodified. We present this as a proof-of-concept validation of a novel reference-electrode architecture for motion artifact suppression in non-contact ECG. The method was validated on 7 subjects across 24 recording sessions using two electrode configurations in two environments with different electromagnetic interference levels. Controlled axial rotation motion was induced at three frequencies using a custom apparatus with IMU-based gamification for protocol adherence. Performance was evaluated using R-peak detection F1 score against gel surface-contact electrodes ground truth and RMS reduction in motion regions. Results demonstrate consistent improvement in R-peak detection accuracy during motion periods with substantial artifact energy reduction. The proposed method is designed to address motion artifacts regardless of their physical source, though the present validation focused on subject-induced motion. Full article
Show Figures

Figure 1

14 pages, 6284 KB  
Article
A New Self-Made 16-Channel Capacitive Electrocardiography System: An Investigation and Validation for Non-Contact Electrodes
by Jinru Yang, Tianjun Wang, Haipo Cui and Limin Sun
Sensors 2025, 25(2), 445; https://doi.org/10.3390/s25020445 - 14 Jan 2025
Cited by 2 | Viewed by 5574
Abstract
Generally, the electrocardiography (ECG) system plays an important role in preventing and diagnosing heart diseases. To further improve the amenity and convenience of using an ECG system, we built a customized capacitive electrocardiography (cECG) system with one wet electrode, sixteen non-contact electrodes, two [...] Read more.
Generally, the electrocardiography (ECG) system plays an important role in preventing and diagnosing heart diseases. To further improve the amenity and convenience of using an ECG system, we built a customized capacitive electrocardiography (cECG) system with one wet electrode, sixteen non-contact electrodes, two ADS1299 chips, and one STM32F303-based microcontroller unit (MCU). This new cECG system could acquire, save, and display the ECG data in real time. The bias feedback as a critical technique was routed to the left hand with the wet Ag/AgCl electrode, which could greatly suppress the power line noise. After all artifacts were removed, the ECG signals could be discerned clearly. We demonstrated that the ECG signals acquired with the capacitive electrodes were similar to those with the wet electrode. Thus, we successfully provide a new configuration for cECG monitoring at home or in a clinical setting. Full article
(This article belongs to the Section Biomedical Sensors)
Show Figures

Figure 1

17 pages, 8852 KB  
Article
Non-Contact Monitoring of ECG in the Home Environment—Selecting Optimal Electrode Configuration
by Adam Bujnowski, Kamil Osiński, Piotr Przystup and Jerzy Wtorek
Sensors 2022, 22(23), 9475; https://doi.org/10.3390/s22239475 - 4 Dec 2022
Cited by 3 | Viewed by 4231
Abstract
Capacitive electrocardiography (cECG) is most often used in wearable or embedded measurement systems. The latter is considered in the paper. An optimal electrocardiographic lead, as an individual feature, was determined based on model studies. It was defined as the possibly highest value of [...] Read more.
Capacitive electrocardiography (cECG) is most often used in wearable or embedded measurement systems. The latter is considered in the paper. An optimal electrocardiographic lead, as an individual feature, was determined based on model studies. It was defined as the possibly highest value of the R-wave amplitude measured on the back of the examined person. The lead configuration was also analyzed in terms of minimizing its susceptibility to creating motion artifacts. It was found that the direction of the optimal lead coincides with the electrical axis of the heart. Moreover, the electrodes should be placed in the areas preserving the greatest voltage and at the same time characterized by the lowest gradient of the potential. Experimental studies were conducted using the developed measurement system on a group of 14 people. The ratio of the R-wave amplitude (as measured on the back and chest, using optimal leads) was less than 1 while the SNR reached at least 20 dB. These parameters allowed for high-quality QRS complex detection with a PPV of 97%. For the “worst” configurations of the leads, the signals measured were practically uninterpretable. Full article
Show Figures

Figure 1

4 pages, 703 KB  
Proceeding Paper
Feasibility Study on Fabric-Sheet Unified Sensing Electrode for Non-Contact In-Bed Measurements of ECG, Body Proximity and Respiratory Movement
by Yuichiro Sakajiri and Akinori Ueno
Proceedings 2019, 15(1), 19; https://doi.org/10.3390/proceedings2019015019 - 10 Jul 2019
Viewed by 1742
Abstract
In a recent article, we have reported that a fabric-sheet unified sensing electrode (FUSE) can detect electrocardiogram (ECG), body proximity at the chest and abdomen (BPxchest, BPxabd) and respiratory movement at the abdomen (RMabd) via worn clothes [...] Read more.
In a recent article, we have reported that a fabric-sheet unified sensing electrode (FUSE) can detect electrocardiogram (ECG), body proximity at the chest and abdomen (BPxchest, BPxabd) and respiratory movement at the abdomen (RMabd) via worn clothes and bedsheet simultaneously from recumbent human subject. We conducted feasibility study involving 21 subjects to assess the influence of individual difference on this FUSE system. Results revealed that individual difference of physical constitution had little impact on both accuracies of ECG R wave and RMabd under the current FUSE configuration, but had some influence on the voltage changes in BPxchest and BPxabd caused by postural change. We deemed to revise some dimensions of the FUSE to avoid individual threshold setting for sitting up detection. Full article
(This article belongs to the Proceedings of 7th International Symposium on Sensor Science)
Show Figures

Figure 1

14 pages, 1616 KB  
Article
A Hygroscopic Sensor Electrode for Fast Stabilized Non-Contact ECG Signal Acquisition
by Ee-May Fong and Wan-Young Chung
Sensors 2015, 15(8), 19237-19250; https://doi.org/10.3390/s150819237 - 5 Aug 2015
Cited by 28 | Viewed by 10250
Abstract
A capacitive electrocardiography (cECG) technique using a non-invasive ECG measuring technology that does not require direct contact between the sensor and the skin has attracted much interest. The system encounters several challenges when the sensor electrode and subject’s skin are weakly coupled. Because [...] Read more.
A capacitive electrocardiography (cECG) technique using a non-invasive ECG measuring technology that does not require direct contact between the sensor and the skin has attracted much interest. The system encounters several challenges when the sensor electrode and subject’s skin are weakly coupled. Because there is no direct physical contact between the subject and any grounding point, there is no discharge path for the built-up electrostatic charge. Subsequently, the electrostatic charge build-up can temporarily contaminate the ECG signal from being clearly visible; a stabilization period (3–15 min) is required for the measurement of a clean, stable ECG signal at low humidity levels (below 55% relative humidity). Therefore, to obtain a clear ECG signal without noise and to reduce the ECG signal stabilization time to within 2 min in a dry ambient environment, we have developed a fabric electrode with embedded polymer (FEEP). The designed hygroscopic FEEP has an embedded superabsorbent polymer layer. The principle of FEEP as a conductive electrode is to provide humidity to the capacitive coupling to ensure strong coupling and to allow for the measurement of a stable, clear biomedical signal. The evaluation results show that hygroscopic FEEP is capable of rapidly measuring high-accuracy ECG signals with a higher SNR ratio. Full article
(This article belongs to the Special Issue Noninvasive Biomedical Sensors)
Show Figures

Figure 1

Back to TopTop