Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (5)

Search Parameters:
Keywords = as low as diagnostically acceptable (ALADA)

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
11 pages, 347 KiB  
Communication
The “Dedicated” C.B.C.T. in Dentistry
by Salvatore Distefano, Maria Grazia Cannarozzo, Gianrico Spagnuolo, Marco Brady Bucci and Roberto Lo Giudice
Int. J. Environ. Res. Public Health 2023, 20(11), 5954; https://doi.org/10.3390/ijerph20115954 - 25 May 2023
Cited by 11 | Viewed by 3974
Abstract
This position statement represents a consensus of an expert committee composed by the Italian Academy of General Dentistry (Accademia Italiana Odontoiatria Generale COI-AIOG) and Italian Academy of Legal and Forensic Dentistry (Accademia Italiana di Odontoiatria Legale e Forense OL-F) on the appropriate use [...] Read more.
This position statement represents a consensus of an expert committee composed by the Italian Academy of General Dentistry (Accademia Italiana Odontoiatria Generale COI-AIOG) and Italian Academy of Legal and Forensic Dentistry (Accademia Italiana di Odontoiatria Legale e Forense OL-F) on the appropriate use of cone beam computed tomography (C.B.C.T.) in dentistry. This paper analyzes the use of C.B.C.T. in light of the rapid evolution of volumetric technologies, with the new low- and ultra-low-dose exposure programs. These upgrades are determining an improvement in the precision and safety of this methodology; therefore, the need of a guideline revision of the use of C.B.C.T. for treatment planning is mandatory. It appears necessary to develop a new model of use, which, in compliance with the principle of justification and as low as reasonably achievable (ALARA) and as low as diagnostically acceptable (ALADA), can allow a functional “Dedicated C.B.C.T.” exam optimized for the individuality of the patient. Full article
(This article belongs to the Collection Oral and Public Health)
21 pages, 2933 KiB  
Article
Prediction of the as Low as Diagnostically Acceptable CT Dose for Identification of the Inferior Alveolar Canal Using 3D Convolutional Neural Networks with Multi-Balancing Strategies
by Asma’a Al-Ekrish, Syed Azhar Hussain, Hebah ElGibreen, Rana Almurshed, Luluah Alhusain, Romed Hörmann and Gerlig Widmann
Diagnostics 2023, 13(7), 1220; https://doi.org/10.3390/diagnostics13071220 - 23 Mar 2023
Viewed by 2286
Abstract
Ionizing radiation is necessary for diagnostic imaging and deciding the right radiation dose is extremely critical to obtain a decent quality image. However, increasing the dosage to improve the image quality has risks due to the potential harm from ionizing radiation. Thus, finding [...] Read more.
Ionizing radiation is necessary for diagnostic imaging and deciding the right radiation dose is extremely critical to obtain a decent quality image. However, increasing the dosage to improve the image quality has risks due to the potential harm from ionizing radiation. Thus, finding the optimal as low as diagnostically acceptable (ALADA) dosage is an open research problem that has yet to be tackled using artificial intelligence (AI) methods. This paper proposes a new multi-balancing 3D convolutional neural network methodology to build 3D multidetector computed tomography (MDCT) datasets and develop a 3D classifier model that can work properly with 3D CT scan images and balance itself over the heavy unbalanced multi-classes. The proposed models were exhaustively investigated through eighteen empirical experiments and three re-runs for clinical expert examination. As a result, it was possible to confirm that the proposed models improved the performance by an accuracy of 5% to 10% when compared to the baseline method. Furthermore, the resulting models were found to be consistent, and thus possibly applicable to different MDCT examinations and reconstruction techniques. The outcome of this paper can help radiologists to predict the suitability of CT dosages across different CT hardware devices and reconstruction algorithms. Moreover, the developed model is suitable for clinical application where the right dose needs to be predicted from numerous MDCT examinations using a certain MDCT device and reconstruction technique. Full article
Show Figures

Figure 1

13 pages, 1404 KiB  
Article
ALADA Dose Optimization in the Computed Tomography of the Temporal Bone: The Diagnostic Potential of Different Low-Dose CT Protocols
by Barbara Kofler, Laura Jenetten, Annette Runge, Gerald Degenhart, Natalie Fischer, Romed Hörmann, Michael Steurer and Gerlig Widmann
Diagnostics 2021, 11(10), 1894; https://doi.org/10.3390/diagnostics11101894 - 15 Oct 2021
Cited by 10 | Viewed by 5413
Abstract
Objective: Repeated computed tomography (CT) is essential for diagnosis, surgical planning and follow-up in patients with middle and inner ear pathology. Dose reduction to “as low as diagnostically acceptable” (ALADA) is preferable but challenging. We aimed to compare the diagnostic quality of images [...] Read more.
Objective: Repeated computed tomography (CT) is essential for diagnosis, surgical planning and follow-up in patients with middle and inner ear pathology. Dose reduction to “as low as diagnostically acceptable” (ALADA) is preferable but challenging. We aimed to compare the diagnostic quality of images of subtle temporal bone structures produced with low doses (LD) and reference protocols (RP). Methods: Two formalin-fixed human cadaver heads were scanned using a 64-slice CT scanner and cone-beam CT (CBCT). The protocols were: RP (120 kV, 250 mA, CTDIvol 83.72 mGy), LD1 (100 kV, 80 mA, CTDIvol 26.79 mGy), LD2 (100 kV, 35 mA, CTDIvol 7.66 mGy), LD3 (80 kV, 40 mA, CTDIvol 4.82 mGy), and CBCT standard protocol. Temporal bone structures were assessed using a 5-point scale. Results: A median score of ≥2 was achieved with protocols such as the tendons of m. tensor tympani (RP/LD1/LD2/CBCT) and m. stapedius (CBCT), the incudostapedial joint (RP/LD1/CBCT), the incudomalleolar joint (RP/LD1/LD2/CBCT), the stapes feet (RP/LD1/CBCT), the stapes head (RP/LD1/LD2/CBCT), the tympanic membrane (RP/LD1/LD2/CBCT), the lamina spiralis ossea (none), the chorda tympani (RP/LD1/CBCT), and the modiolus (RP/LD1/LD2/CBCT). Adaptive statistical iterative reconstructions did not show advantages over the filtered back projection. Conclusions: LD protocols using a CTDIvol of 7.66 mGy may be sufficient for the identification of temporal bone structures. Full article
(This article belongs to the Special Issue Radiation Dose and Image Quality in CT Imaging)
Show Figures

Figure 1

9 pages, 795 KiB  
Article
Detectability of Osseous Lesions with a Pre-Programmed Low-Dose Protocol for Cone-Beam Computed Tomography
by Quirin Döbelin, Bernd Stadlinger, Daniel B. Wiedemeier, Dominique Bichsel, Martin Rücker and Silvio Valdec
Appl. Sci. 2020, 10(14), 4961; https://doi.org/10.3390/app10144961 - 19 Jul 2020
Cited by 6 | Viewed by 3198
Abstract
The present study aimed to compare the diagnostic reliability of a pre-set, manufacturer-specific, low-dose mode against a standard-dose mode in the detection of four different osseous lesions in the mandible with cone-beam computed tomography (CBCT). Four types of lesions (periapical lesion, extended periodontal [...] Read more.
The present study aimed to compare the diagnostic reliability of a pre-set, manufacturer-specific, low-dose mode against a standard-dose mode in the detection of four different osseous lesions in the mandible with cone-beam computed tomography (CBCT). Four types of lesions (periapical lesion, extended periodontal gap, recession of the buccal lamella, sequestrum/fracture) were prepared on 40 pig mandibles. CBCT images were obtained from each mandible, with both the low-dose and standard-dose modes using the Orthophos SL CBCT device (Dentsply-Sirona, Bensheim, Germany). Twelve assessors quantitatively (detection of lesions) and qualitatively (assessment of detectability) evaluated the CBCT images in SIDEXIS 4 (Dentsply-Sirona) using a study-specific digital examination tool. A correct diagnosis was achieved in almost 71% (LD: 70.8%; SD: 70.9%) of 1920 lesions, without a statistically significant difference between the low-dose and standard-dose mode. This finding was consistent across all four lesion types. In conclusion, while low-dose mode and standard-dose mode CBCT scans performed similarly in the detection of four prepared lesions of the mandible, the former may be a promising, user-friendly alternative method of obtaining radiation-optimized, three-dimensional images in accordance with the As Low As Diagnostically Acceptable (ALADA) principle. Full article
(This article belongs to the Special Issue Applied Sciences in Dentistry)
Show Figures

Figure 1

20 pages, 6428 KiB  
Article
Generative Noise Reduction in Dental Cone-Beam CT by a Selective Anatomy Analytic Iteration Reconstruction Algorithm
by Lam Dao-Ngoc and Yi-Chun Du
Electronics 2019, 8(12), 1381; https://doi.org/10.3390/electronics8121381 - 21 Nov 2019
Cited by 8 | Viewed by 4729
Abstract
Dental cone-beam computed tomography (CBCT) is a powerful tool in clinical treatment planning, especially in a digital dentistry platform. Currently, the “as low as diagnostically acceptable” (ALADA) principle and diagnostic ability are a trade-off in most of the 3D integrated applications, especially in [...] Read more.
Dental cone-beam computed tomography (CBCT) is a powerful tool in clinical treatment planning, especially in a digital dentistry platform. Currently, the “as low as diagnostically acceptable” (ALADA) principle and diagnostic ability are a trade-off in most of the 3D integrated applications, especially in the low radio-opaque densified tissue structure. The CBCT benefits in comprehensive diagnosis and its treatment prognosis for post-operation predictability are clinically known in modern dentistry. In this paper, we propose a new algorithm called the selective anatomy analytic iteration reconstruction (SA2IR) algorithm for the sparse-projection set. The algorithm was simulated on a phantom structure analogous to a patient’s head for geometric similarity. The proposed algorithm is projection-based. Interpolated set enrichment and trio-subset enhancement were used to reduce the generative noise and maintain the scan’s clinical diagnostic ability. The results show that proposed method was highly applicable in medico-dental imaging diagnostics fusion for the computer-aided treatment planning, because it had significant generative noise reduction and lowered computational cost when compared to the other common contemporary algorithms for sparse projection, which generate a low-dosed CBCT reconstruction. Full article
(This article belongs to the Special Issue Intelligent Electronic Devices)
Show Figures

Figure 1