Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (2)

Search Parameters:
Keywords = White, Lynn Jr.

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
14 pages, 5145 KB  
Article
Investigation of How Corneal Densitometry Artefacts Affect the Imaging of Normal and Keratoconic Corneas
by Rami Alanazi, Louise Pellegrino Gomes Esporcatte, Lynn White, Marcella Q. Salomão, Bernardo T. Lopes, Renato Ambrósio Jr. and Ahmed Abass
Bioengineering 2024, 11(2), 148; https://doi.org/10.3390/bioengineering11020148 - 1 Feb 2024
Cited by 3 | Viewed by 10832
Abstract
Purpose: To investigate corneal densitometry artefacts found in Pentacam Scheimpflug scans and their potential effect on assessing keratoconic (KC) corneas compared to normal (N) corneas. Methods: The current study utilises Pentacam data of 458 N eyes, aged 35.6 ± 15.8 (range 10–87), referred [...] Read more.
Purpose: To investigate corneal densitometry artefacts found in Pentacam Scheimpflug scans and their potential effect on assessing keratoconic (KC) corneas compared to normal (N) corneas. Methods: The current study utilises Pentacam data of 458 N eyes, aged 35.6 ± 15.8 (range 10–87), referred to as the “N group”, and 314 KC eyes, aged 31.6 ± 10.8 (range 10–72), referred to as the “KC group”, where densitometry data were extracted and analysed via a custom-built MATLAB code. Radial summations of the densitometry were calculated at diameters ranging from 0.5 mm to 5.0 mm. The minimum normalised radial summation of densitometry (NRSD) value and angle were determined at each diameter and then linked. KC cone locations and areas of pathology were determined, and a comparison between N and KC groups was carried out both within the averaged area of pathology and over the corneal surface. Results: Joining minimum NRSD trajectory points marked a clear distortion line pointing to the nasal-superior direction at 65° from the nasal meridian. The findings were found to be independent of eye laterality or ocular condition. Consistency was detected in the right and left eyes among both the N and KC groups. The location of the KC cone centre and the area of pathology were determined, and the densitometry output was compared both within the area of pathology and over the whole cornea. When the average densitometry was compared between N and KC eyes within the KC area of pathology, the N group recorded a 16.37 ± 3.15 normalised grey-scale unit (NGSU), and the KC group recorded 17.74 ± 3.4 NGSU (p = 0.0001). However, when the whole cornea was considered, the N group recorded 16.71 ± 5.5 NGSU, and the KC group recorded 15.72 ± 3.98 NGSU (p = 0.0467). A weak correlation was found between the Bad D index and NGSU when the whole measured cornea was considered (R = −0.01); however, a better correlation was recorded within the KC area of pathology (R = 0.21). Conclusions: Nasal-superior artefacts are observed in the densitometry Pentacam maps, and analysis shows no significant differences in their appearance between N or KC corneas. When analysing KC corneas, it was found that the cone positions are mostly on the temporal-inferior side of the cornea, opposite to the densitometry artefact NRSD trajectory. The analysis suggests that the corneal densitometry artefacts do not interfere with the KC area of pathology as it reaches its extreme in the opposite direction; therefore, weighting the densitometry map to increase the contribution of the inferior-temporal cornea and decreasing that of the superior-nasal area would improve the classification or identification of KC if densitometry is to be used as a KC metric. Full article
(This article belongs to the Section Biochemical Engineering)
Show Figures

Figure 1

13 pages, 219 KB  
Article
A Christian Case for Farmed Animal Welfare
by Margaret B. Adam, David L. Clough and David Grumett
Animals 2019, 9(12), 1116; https://doi.org/10.3390/ani9121116 - 11 Dec 2019
Cited by 11 | Viewed by 8749
Abstract
It is now common to blame Christianity for broader society’s general inattention to the needs and comfort of animals in general, and farmed animals in particular. This critique of Christianity claims that certain biblical themes and particular biblical passages form the foundation for [...] Read more.
It is now common to blame Christianity for broader society’s general inattention to the needs and comfort of animals in general, and farmed animals in particular. This critique of Christianity claims that certain biblical themes and particular biblical passages form the foundation for an anti-animal position that Christianity has imposed on Christians and on wider Western society. This article concedes that Christianity has often been used to justify exploitation of animals, but argues that it is a mistake to consider Christianity inevitably opposed to concern for animals. After reviewing the views of critics such as Lynn White Jr., Peter Singer, and Tom Regan, the article demonstrates the complexity of interpreting biblical passages and the possibility of readings that affirm the importance of treating animals well. It shows that Christians have indeed been advocates for animals, notably in relation to the first legislation against animal cruelty in the early nineteenth century and the formation of the RSPCA. Finally, it proposes a constructive framework for a Christian ethics of farmed animal welfare that could provide the basis for Christian action to reduce consumption of animals and shift to higher welfare sources of animal products. Full article
(This article belongs to the Special Issue Animal Ethics: Questioning the Orthodoxy)
Back to TopTop