23 pages, 821 KiB  
Article
Coagulation Status Assessment in Dogs with Chronic Enteropathy Using Viscoelastic Point-of-Care Coagulation Monitor
by María José Marín Lucas, Tim Sparks and Chantal Rosa
Animals 2025, 15(11), 1571; https://doi.org/10.3390/ani15111571 - 28 May 2025
Viewed by 550
Abstract
Canine chronic inflammatory enteropathy (CIE) has been associated with coagulation abnormalities, predisposing affected dogs to a hypercoagulable state and potential thromboembolic events. This study aimed to evaluate the coagulation status in dogs with CIE using a viscoelastic point-of-care device, a Viscoelastic Coagulation Monitor [...] Read more.
Canine chronic inflammatory enteropathy (CIE) has been associated with coagulation abnormalities, predisposing affected dogs to a hypercoagulable state and potential thromboembolic events. This study aimed to evaluate the coagulation status in dogs with CIE using a viscoelastic point-of-care device, a Viscoelastic Coagulation Monitor (VCM Vet®). A retrospective review of medical records identified 38 dogs diagnosed with CIE that underwent VCM Vet® testing. Coagulation profiles were classified as hypercoagulable, normocoagulable, or hypocoagulable. The results demonstrate that 81.5% of dogs exhibited hypercoagulability, and significant associations were found between the coagulation status and the type of CIE. Hypercoagulability was more commonly found in immunosuppressive-responsive enteropathy (IRE) cases. Albumin and cobalamin were significantly higher in food-responsive enteropathy, whereas the canine chronic enteropathy clinical activity index (CCECAI) was significantly higher in immunosuppressive-responsive enteropathy and non-responsive enteropathy. One dog with protein-losing enteropathy (PLE) was suspected of having developed possible pulmonary thromboembolism. These findings reinforce previous reports of hypercoagulability in CIE and suggest that VCM Vet® is a valuable and easy tool to assess coagulation abnormalities in a clinical setting. Further investigation is warranted to evaluate the clinical implications of hypercoagulability in CIE and the potential role of anticoagulant therapy in disease management. Full article
(This article belongs to the Section Veterinary Clinical Studies)
Show Figures

Figure 1

13 pages, 2395 KiB  
Article
Decreased Circulating Red Cell Mass Induced by Intravenous Acepromazine Administration Alters Viscoelastic and Traditional Plasma Coagulation Testing Results in Healthy Horses
by Ina Mersich, Rebecca C. Bishop, Sandra Diaz Yucupicio, Ana D. Nobrega, Scott M. Austin, Anne M. Barger, Meghan E. Fick and Pamela Anne Wilkins
Animals 2024, 14(21), 3102; https://doi.org/10.3390/ani14213102 - 28 Oct 2024
Cited by 1 | Viewed by 1430
Abstract
Coagulopathy is common in equine critical illness, with its early recognition being crucial for patient management and prognosis. In vitro viscoelastic (VE) hypercoagulability with decreased RCM/PCV has been demonstrated in dogs but not horses. Our objective was to evaluate the effects of acepromazine-induced [...] Read more.
Coagulopathy is common in equine critical illness, with its early recognition being crucial for patient management and prognosis. In vitro viscoelastic (VE) hypercoagulability with decreased RCM/PCV has been demonstrated in dogs but not horses. Our objective was to evaluate the effects of acepromazine-induced (0.1 mg/kg IV) decreased RCM on VE and plasma coagulation parameters using a prospective interventional study of eight adult horses. Complete blood count (CBC), fibrinogen, prothrombin time (PT), partial thromboplastin time (PTT), packed cell volume (PCV), total solids (TS), and VCM Vet™ VE testing performed at baseline (T0), 1 h (T1), and 12 h (T2) post acepromazine administration. Splenic volume was determined ultrasonographically. The results were analyzed using one-way repeated measures ANOVA with Tukey’s post hoc HSD test to determine the effect of time (sample). PCV decreased 13% points following acepromazine administration from T0 to T1 (p < 0.001), remaining decreased at T2 (p < 0.001). Splenic volume increased from T0 to T1 (p = 0.04) and was not different from baseline at T2. Maximal clot formation (MCF) increased from T0 (p = 0.03). PTT decreased from T0 to T1 and increased at T2 (p = 0.03). No other coagulation parameters were significantly altered. This study demonstrates a non-inflammatory acute model of anemia in horses that impacts VE and plasma-based testing. Full article
(This article belongs to the Special Issue Equine Internal Medicine)
Show Figures

Figure 1

12 pages, 639 KiB  
Article
Comparison of Citrated Whole Blood to Native Whole Blood for Coagulation Testing Using the Viscoelastic Coagulation Monitor (VCM Vet™) in Horses
by Jessica R. Vokes, Amy L. Lovett, Max C. de Kantzow, Chris W. Rogers, Pamela A. Wilkins and Benjamin W. Sykes
Animals 2024, 14(19), 2892; https://doi.org/10.3390/ani14192892 - 8 Oct 2024
Cited by 1 | Viewed by 6379
Abstract
Viscoelastic monitoring of horse coagulation is increasing due to its advantages over traditional coagulation testing. The use of a point-of-care viscoelastic coagulation monitor (VCM Vet™) has been validated for use in horses using native whole blood (NWB) but has not been assessed using [...] Read more.
Viscoelastic monitoring of horse coagulation is increasing due to its advantages over traditional coagulation testing. The use of a point-of-care viscoelastic coagulation monitor (VCM Vet™) has been validated for use in horses using native whole blood (NWB) but has not been assessed using citrated whole blood (CWB), a technique that might have advantages in practicality and precision. Blood was collected from 70 horses, tested in duplicate immediately using NWB (T0), and stored at room temperature as CWB for testing in duplicate at 1 (T1) and 4 (T4) hours after venipuncture for comparison to NWB. Of these horses, 20 were classified as clinically healthy and used to determine reference intervals for CWB at 1 and 4 h post-collection. There were clinically relevant differences in all measured viscoelastic parameters of CWB compared to NWB meaning that they cannot be used interchangeably. These differences were not consistent at T1 and T4 meaning the resting time of CWB influences the results and should be kept consistent. The use of CWB in this study also resulted in more machine errors when compared to NWB resulting in measurements that might not be interpretable. Full article
(This article belongs to the Section Equids)
Show Figures

Figure 1

12 pages, 290 KiB  
Article
Evaluation of a Viscoelastic Coagulation Monitoring System (VCM Vet®) and Its Correlation with Thromboelastometry (ROTEM®) in Diseased and Healthy Dogs
by Imke Hennink, Laureen Peters, Geert van Geest and Katja-Nicole Adamik
Animals 2023, 13(3), 405; https://doi.org/10.3390/ani13030405 - 25 Jan 2023
Cited by 14 | Viewed by 3252
Abstract
Thromboelastometry provides a real-time assessment of global coagulation in whole blood. A novel bed-side viscoelastic coagulation monitor (VCM) has been developed for use in small animals. The aims of the study were to determine inter-device agreement of two VCM devices, to evaluate the [...] Read more.
Thromboelastometry provides a real-time assessment of global coagulation in whole blood. A novel bed-side viscoelastic coagulation monitor (VCM) has been developed for use in small animals. The aims of the study were to determine inter-device agreement of two VCM devices, to evaluate the correlation between VCM and rotational thromboelastometry as a reference method (ROTEM), and to determine the sensitivity and specificity of VCM to diagnose hypo-, normo-, and hypercoagulability. ROTEM (extrinsic and intrinsic activation) analysis was performed using citrated blood and VCM analysis using native blood. Twenty healthy and forty diseased dogs with and without coagulopathies were enrolled. The VCM inter-device agreement was moderate to strong for most of the parameters, depending on the grading scale. Correlation between VCM and ROTEM was moderate to strong for parameters of clotting time and clot strength. The VCM most likely detects true hypocoagulability and reliably rules out hypocoagulability. The VCM has a high sensitivity in diagnosing normocoagulability, but incorrectly classified dogs with abnormal coagulation as normocoagulable. The VCM was not able to detect hypercoagulability. ROTEM and VCM cannot be used interchangeably. Full article