Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (10)

Search Parameters:
Keywords = Schlemm’s canal-opening surgery

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
14 pages, 1528 KiB  
Article
Surgical Outcomes of Gonioscopy-Assisted Transluminal Trabeculotomy (GATT) in Primary and Secondary Open- and Closed-Angle Glaucoma
by Liron Naftali Ben Haim, Veronika Yehezkeli, Assaf Kratz, Nimrod Dar, Tal Sharon, Gal Harel, Zvia Burganski-Eliash and Avner Belkin
Diagnostics 2025, 15(10), 1226; https://doi.org/10.3390/diagnostics15101226 - 13 May 2025
Viewed by 602
Abstract
Background: Gonioscopy-assisted transluminal trabeculotomy (GATT) is a minimally invasive, ab interno conjunctival-sparing glaucoma surgery aimed at the trabecular meshwork and the inner wall of Schlemm’s canal. The goal of this study is to report on the success of GATT in a large group [...] Read more.
Background: Gonioscopy-assisted transluminal trabeculotomy (GATT) is a minimally invasive, ab interno conjunctival-sparing glaucoma surgery aimed at the trabecular meshwork and the inner wall of Schlemm’s canal. The goal of this study is to report on the success of GATT in a large group of patients with a wide variety of open- and closed-angle glaucomas with or without cataract extraction and to report on risk factors for failure. Methods: A retrospective chart review of consecutive patients with primary or secondary open- or closed-angle glaucoma who underwent GATT, with or without concomitant phacoemulsification. Demographics, baseline clinical characteristics, and postoperative outcomes were collected from patients’ medical records. Primary outcomes were success rates (IOP of 18 mmHg or lower and one of the following: IOP reduction > 30% from baseline on the same or fewer medications or an IOP ≤ baseline with fewer medications as compared to baseline) and complication rates. Intraocular pressure (IOP) and the number of glaucoma medications were secondary outcome measures. Results: GATT was performed on 126 eyes of 121 patients. Mean follow-up was 583 ± 266 days. Cumulative success at 1Y was 0.88 for GATT combined with cataract extraction, 0.96 for GATT alone, 0.88 for primary open-angle glaucoma (POAG), 0.89 for secondary open-angle glaucoma (SOAG), and 0.76 for primary angle-closure glaucoma (PACG). IOP decreased from a mean of 20.65 mmHg to 14.1 mmHg, and medication decreased from a mean of 3.47 to 1.4 at the last follow-up. Forty-four eyes (34%) were classified as failures. Factors associated with an increased risk of failure were worse preoperative corrected visual acuity (OR = 2.46, p = 0.024) and a postoperative IOP spike (OR = 2.62, p = 0.028). Twelve eyes (9.5%) required further surgery for IOP control. Risk factors for requiring further surgery for IOP control were preoperative maximal IOP (OR = 1.066, p = 0.047) and a postoperative IOP spike (OR = 4.531, p = 0.036). Conclusions: GATT achieved good surgical success with good IOP and medication reduction across a wide range of glaucomas, in combination with lens extraction or as a standalone procedure. GATT should be considered early in the treatment paradigm of medically uncontrolled glaucoma. Full article
(This article belongs to the Special Issue Diagnosis and Management of Ophthalmic Disorders)
Show Figures

Figure 1

31 pages, 412 KiB  
Review
Visual Function After Schlemm’s Canal-Based MIGS
by Masayuki Kasahara and Nobuyuki Shoji
J. Clin. Med. 2025, 14(7), 2531; https://doi.org/10.3390/jcm14072531 - 7 Apr 2025
Viewed by 939
Abstract
Filtration surgery is highly effective in lowering intraocular pressure; however, it is associated with a higher risk of severe complications. Visual dysfunction may persist in relatively uneventful cases because of induced astigmatism or worsening optical aberrations. Therefore, for early- to moderate-stage glaucoma, an [...] Read more.
Filtration surgery is highly effective in lowering intraocular pressure; however, it is associated with a higher risk of severe complications. Visual dysfunction may persist in relatively uneventful cases because of induced astigmatism or worsening optical aberrations. Therefore, for early- to moderate-stage glaucoma, an increasing number of surgeons are prioritizing surgical safety and preserving postoperative visual function by opting for minimally invasive glaucoma surgery (MIGS). Among the various MIGS techniques, canal-opening surgery—targeting aqueous outflow through the Schlemm’s canal (Schlemm’s canal-based MIGS, CB-MIGS)—has gained increasing popularity. Unlike filtration surgery, CB-MIGS does not require creating an aqueous outflow pathway between the intraocular and extraocular spaces. Consequently, it is considered a minimally invasive procedure with a reduced risk of severe complications and is increasingly being chosen for suitable cases. Although this surgical technique has limitations in lowering intraocular pressure, it avoids the manipulation of the conjunctiva or sclera and is primarily performed through a small corneal incision. Therefore, a minimal impact on induced astigmatism or postoperative refractive changes is expected. However, few reviews comprehensively summarize postoperative changes in visual function. Therefore, this study reviews the literature on visual function after CB-MIGS, focusing on changes in best-corrected visual acuity (BCVA), refraction, astigmatism, and the effectiveness of visual field preservation to assess the extent of these postoperative changes. Hyphema is the primary cause of early postoperative vision loss and is often transient in cases in which other complications would have led to visual impairment. Severe complications that threaten vision are rare. Additionally, compared with filtration surgery, postoperative visual recovery tends to be faster, and the degree of induced astigmatism is comparable to that of standalone cataract surgery. When combined with cataract surgery, the refractive error is at the same level as that of cataract surgery alone. However, in some cases, mild hyperopic shifts may occur because of axial length shortening, depending on the extent of intraocular pressure reduction. This possibility has been highlighted in several studies. Regarding the effectiveness of slowing the progression of visual field defects, most studies have focused on short- to medium-term postoperative outcomes. Many of these studies have reported the sufficient suppression of progression rates. However, studies with large sample sizes and long-term prospective designs are limited. To establish more robust evidence, future research should focus on conducting larger-scale, long-term investigations. Full article
(This article belongs to the Special Issue Clinical Debates in Minimally Invasive Glaucoma Surgery (MIGS))
10 pages, 2627 KiB  
Article
Diabetes Mellitus: A Risk Factor in Schlemm’s Canal-Based Minimally Invasive Glaucoma Surgery
by Etsuo Chihara, Eri Nakano and Tomoyuki Chihara
J. Clin. Med. 2024, 13(24), 7660; https://doi.org/10.3390/jcm13247660 - 16 Dec 2024
Viewed by 693
Abstract
Objectives: The objective of this study was to evaluate the impact of diabetes mellitus (DM) on the outcome of Schlemm’s canal-based minimally invasive glaucoma surgery (MIGS). Methods: In a retrospective interventional cohort study, postoperative intraocular pressure (IOP) and intracameral bleeding were analyzed [...] Read more.
Objectives: The objective of this study was to evaluate the impact of diabetes mellitus (DM) on the outcome of Schlemm’s canal-based minimally invasive glaucoma surgery (MIGS). Methods: In a retrospective interventional cohort study, postoperative intraocular pressure (IOP) and intracameral bleeding were analyzed in 25 diabetic patients and 84 non-diabetic patients, with primary open-angle glaucoma (POAG) or ocular hypertension (OH). Results: The mean follow-up period for all 109 eyes was 35.3 ± 24.8 months. There was no significant difference in preoperative IOP between cohorts with or without diabetes. However, the post-surgical IOP between 3 months and 2 years was significantly higher in the cohort with diabetes (p = 0.019 to 0.001). The 3-year survival probability of achieving an IOP ≤ 15 mmHg was 17.8 ± 0.09% in patients with diabetes, significantly lower than the 30.4 ± 0.06% observed in patients without diabetes (p = 0.042 Log-rank test). The 3-year survival probability of achieving an IOP ≤ 18 mmHg was 56.7 ± 0.12% in patients with diabetes compared to 79.5 ± 0.05% in patients without diabetes, indicating a marginally significant difference between cohorts with and without diabetes (p = 0.065). When the random effect of diabetes mellitus (DM) was analyzed alongside the fixed effects of preoperative IOP, age, refractive error, and the extent of canal opening using a multivariate linear mixed model, DM emerged as a significant risk factor for higher postoperative IOP at both 6 and 12 months (p < 0.001). Conclusions: Diabetes mellitus is a significant risk factor for poor outcomes following Schlemm’s canal-based MIGS, particularly in achieving lower postoperative IOP. Full article
(This article belongs to the Section Ophthalmology)
Show Figures

Figure 1

9 pages, 1940 KiB  
Article
One-Year Outcomes of Trabeculotomy with 120°, 180°, or 360° Schlemm’s Canal Incision for Primary Open-Angle Glaucoma: A Retrospective Study
by Hidetsugu Mori, Tatsunori Kiriishi, Masatoshi Omi, Masayuki Ohnaka and Hisanori Imai
J. Clin. Med. 2024, 13(24), 7653; https://doi.org/10.3390/jcm13247653 - 16 Dec 2024
Cited by 1 | Viewed by 685
Abstract
Background/Objectives: Primary open-angle glaucoma (POAG), if caused by elevated intraocular pressure (IOP), may require a trabeculotomy (LOT), in which the trabecular meshwork (TM) and Schlemm’s canal (ISC) are incised. However, the association between the incision angle and outcomes remains unclear. Therefore, in this [...] Read more.
Background/Objectives: Primary open-angle glaucoma (POAG), if caused by elevated intraocular pressure (IOP), may require a trabeculotomy (LOT), in which the trabecular meshwork (TM) and Schlemm’s canal (ISC) are incised. However, the association between the incision angle and outcomes remains unclear. Therefore, in this study, we investigated the surgical outcomes of a trabeculotomy combined with cataract surgery in patients with POAG over a 12-month follow-up period. Methods: We included 66 patients (corresponding to 83 eyes) with POAG who underwent trabeculotomy ab externo with a metal probe (M-LOT: 120° incision of the TM and ISC), ab interno with a Kahook Dual Blade® (K-LOT: 180° incision of the TM and ISC), or ab interno with a 5-0 nylon suture (S-LOT: 360° incision of the TM and ISC) between January 2015 and December 2022. We assessed IOP, the percentage reduction from preoperative IOP, the number of IOP-lowering medications taken, the incidence of postoperative complications, and the success rate using Kaplan–Meier survival analysis. Results: The median IOP was significantly lower than the baseline across all three groups. The number of IOP-lowering medications taken was significantly reduced only in the M-LOT group. The mean percentage reduction from the preoperative IOP in the K-LOT group was significantly lower than that in the M and S-LOT groups. Beween those subjected to an ab ineterno LOT, the S-LOT group demonstrated a significantly higher rate of IOP reduction 12 months after the operation compared to the K-LOT group. Kaplan–Meier cumulative survival analyses revealed a lower success rate for the K-LOT group than for the M and S-LOT groups. The M-LOT group had the lowest incidence of hyphema and IOP spikes, whereas the S-LOT group had the highest incidence of these complications. Conclusions: The M-, K-, and S-LOTs had different surgical outcomes during the 12 months of follow-up, with the M-LOT group showing the fewest complications. These results will help in selecting the most suitable trabeculotomy strategy for patients with POAG. Based on the postoperative outcomes of the ab interno K- and S-LOTs, a wider incision of the TM and ISC leads to effective IOP reduction. Full article
(This article belongs to the Section Ophthalmology)
Show Figures

Figure 1

28 pages, 1580 KiB  
Review
Historical and Contemporary Debates in Schlemm’s Canal-Based MIGS
by Etsuo Chihara and Teruhiko Hamanaka
J. Clin. Med. 2024, 13(16), 4882; https://doi.org/10.3390/jcm13164882 - 19 Aug 2024
Cited by 3 | Viewed by 1514
Abstract
Glaucoma is one of the primary causes of blindness worldwide. Canal opening surgery, a type of minimally invasive glaucoma surgery (MIGS) applied in cases of mild to moderate glaucoma, has gained increasing popularity in recent years due to its efficacy in reducing the [...] Read more.
Glaucoma is one of the primary causes of blindness worldwide. Canal opening surgery, a type of minimally invasive glaucoma surgery (MIGS) applied in cases of mild to moderate glaucoma, has gained increasing popularity in recent years due to its efficacy in reducing the intraocular pressure, its safety profile, the simplicity of its technique, and the reduced likelihood of compromised vision. Nevertheless, the existing body of histopathological studies remains insufficient for a comprehensive understanding of post-surgical wound healing. Consequently, debates persist among researchers regarding the mechanism through which Schlemm’s canal opening surgery reduces the intraocular pressure, as well as the surgical techniques that may impact the outcomes and the factors influencing surgical success. As the history of MIGS is relatively short and lacks sufficient systemic reviews or meta-analyses evaluating the influence of individual factors, this review was conducted to illuminate the disparities in researchers’ opinions at the current stage of research. Full article
(This article belongs to the Special Issue Clinical Debates in Minimally Invasive Glaucoma Surgery (MIGS))
Show Figures

Figure 1

11 pages, 1208 KiB  
Article
Position of the ISTENT Inject® Trabecular Micro-Bypass System Visualized with the NIDEK GS-1 Gonioscope—A Postoperative Analysis
by Julian Alexander Zimmermann, Jens Julian Storp, Ralph-Laurent Merté, Peter Heiduschka, Nicole Eter and Viktoria Constanze Brücher
J. Clin. Med. 2023, 12(16), 5171; https://doi.org/10.3390/jcm12165171 - 8 Aug 2023
Cited by 5 | Viewed by 2676
Abstract
Glaucoma is one of the leading causes of irreversible blindness globally and is characterized by the gradual loss of retinal ganglion cells. The primary risk factor for the development and progression of glaucoma is increased intraocular pressure (IOP). Numerous surgical interventions exist to [...] Read more.
Glaucoma is one of the leading causes of irreversible blindness globally and is characterized by the gradual loss of retinal ganglion cells. The primary risk factor for the development and progression of glaucoma is increased intraocular pressure (IOP). Numerous surgical interventions exist to lower IOP should conservative therapy fail. One trend in recent years has been minimally invasive glaucoma surgery (MIGS) as an alternative to traditional methods. The ISTENT inject® is an ab interno trabecular micro-bypass implant designed to be implanted through the trabecular meshwork into the Schlemm’s canal to lower IOP. The aim of the study was the postoperative visualization and description of the positioning of the ISTENT inject® using automated circumferential goniophotography. Patients with symptomatic cataracts and mild to moderate primary open-angle glaucoma (POAG), pseudoexfoliation glaucoma (PEX), and pigment-dispersion glaucoma were included who underwent combined cataract surgery with the ISTENT inject® and received postoperative automated gonioscopy with the NIDEK Gonioscope GS-1 to visualize the location of the implant. Twenty-four implants of 14 eyes in 11 patients could be visualized. Out of the implants, 14.3% were in the trabecular meshwork, 46.4% were at the border between the trabecular meshwork and scleral spur, 25% were below the trabecular meshwork, and 14.3% of the implants were not detectable in the gonioscopy. In the overall cohort, a statistically significant IOP reduction was found over the 12-month postoperative observation period. Even in three eyes, in each of which both stents were located below the trabecular meshwork, an IOP reduction over 12 months was observed compared to the baseline IOP. In this study, vertical two-dimensional positioning of the ISTENT inject® was performed for the first time using NIDKE GS-1 automated 360° goniophotography. The method is suitable for postoperative visualization, control, and documentation of positioning after ISTENT inject® implantation. Further studies are needed to analyze the correlation between positioning of the ISTENT inject® in the chamber angle and postoperative IOP reduction. Full article
(This article belongs to the Special Issue Innovation in Glaucoma: Imaging and Visual Function)
Show Figures

Figure 1

15 pages, 3021 KiB  
Review
Advances in Canaloplasty—Modified Techniques Yield Strong Pressure Reduction with Low Risk Profile
by Peter Szurman
J. Clin. Med. 2023, 12(8), 3031; https://doi.org/10.3390/jcm12083031 - 21 Apr 2023
Cited by 2 | Viewed by 2321
Abstract
For decades, trabeculectomy (TE) was considered the gold standard for surgical treatment of open-angle glaucoma owing to its powerful intraocular pressure (IOP)-lowering potency. However, owing to the invasive nature and high-risk profile of TE, this standard is changing, and minimally invasive procedures are [...] Read more.
For decades, trabeculectomy (TE) was considered the gold standard for surgical treatment of open-angle glaucoma owing to its powerful intraocular pressure (IOP)-lowering potency. However, owing to the invasive nature and high-risk profile of TE, this standard is changing, and minimally invasive procedures are becoming more preferable. In particular, canaloplasty (CP) has been established as a much gentler alternative in everyday life and is under development as a full-fledged replacement. This technique involves probing Schlemm’s canal with a microcatheter and inserting a pouch suture that places the trabecular meshwork under permanent tension. It aims to restore the natural outflow pathways of the aqueous humor and is independent of external wound healing. This physiological approach results in a significantly lower complication rate and allows considerably simplified perioperative management. There is now extensive evidence that canaloplasty achieves sufficient pressure reduction as well as a significant reduction in postoperative glaucoma medications. Unlike MIGS procedures, the indication is not only mild to moderate glaucoma; today, even advanced glaucoma benefits from the very low hypotony rate, which largely avoids a wipeout phenomenon. However, approximately half of patients are not completely medication-free after canaloplasty. As a consequence, a number of canaloplasty modifications have been developed with the goal of further enhancing the IOP-lowering effect while avoiding the risk of serious complications. By combining canaloplasty with the newly developed suprachoroidal drainage procedure, the individual improvements in trabecular facility and uveoscleral outflow facility appear to have an additive effect. Thus, for the first time, an IOP-lowering effect comparable to a successful trabeculectomy can be achieved. Other implant modifications also enhance the potential of canaloplasty or offer additional benefits such as the possibility of telemetric IOP self-measurement by the patient. This article reviews the modifications of canaloplasty, which has the potential to become a new gold standard in glaucoma surgery via stepwise refinement. Full article
(This article belongs to the Special Issue Advances in Glaucoma Surgery)
Show Figures

Figure 1

15 pages, 1698 KiB  
Article
360° Ab-Interno Schlemm’s Canal Viscodilation with OMNI Viscosurgical Systems for Open-Angle Glaucoma—Midterm Results
by Giacomo Toneatto, Marco Zeppieri, Veronica Papa, Laura Rizzi, Carlo Salati, Andrea Gabai and Paolo Brusini
J. Clin. Med. 2022, 11(1), 259; https://doi.org/10.3390/jcm11010259 - 4 Jan 2022
Cited by 16 | Viewed by 2891
Abstract
Purpose: To evaluate the effectiveness of ab-interno microcatheterization and 360° viscodilation of Schlemm’s canal (SC) performed with OMNI viscosurgical system in open angle glaucoma (OAG) together or not with phacoemulsification. Setting: Two surgical sites. Design: Retrospective, observational. Methods: Eighty eyes from 73 patients [...] Read more.
Purpose: To evaluate the effectiveness of ab-interno microcatheterization and 360° viscodilation of Schlemm’s canal (SC) performed with OMNI viscosurgical system in open angle glaucoma (OAG) together or not with phacoemulsification. Setting: Two surgical sites. Design: Retrospective, observational. Methods: Eighty eyes from 73 patients with mild to moderate OAG underwent ab- interno SC viscodilation performed with OMNI system. Fifty eyes (Group 1) underwent only SC viscodilation, while 30 eyes (Group 2) underwent glaucoma surgery + cataract extraction. Primary success endpoint at 12 months was an intraocular pressure (IOP) reduction higher than 25% from baseline with an absolute value of 18 mmHg or lower, either on the same number or fewer ocular hypotensive medications, without further interventions. Secondary effectiveness endpoints included mean IOP, number of medications and comparison of outcomes between groups. Safety endpoints consisted of best-corrected visual acuity (BCVA), adverse events (AEs), and subsequent surgical procedures. Results: Primary success was achieved in 40.0% and 67.9% in Groups 1 and 2, respectively. Mean IOP at 12-month follow-up showed a significant reduction in both groups (from 23.0 to 15.6 mmHg, p < 0.001, and from 21.5 to 14.1, p < 0.001, in Groups 1 and 2, respectively). Mean medication number decreased in both groups (from 3.0 to 2.0, p < 0.001 and from 3.4 to 1.9, p < 0.001, in Groups 1 and 2, respectively). AEs included hyphema (2 eyes), mild hypotony (4 eyes), IOP spikes one month after surgery (1 eye). Twelve eyes (15.0%) required subsequent surgical procedures. No BCVA reduction was observed. Conclusions: Viscodilation of SC using OMNI viscosurgical systems is safe and relatively effective in reducing IOP in adult patients with OAG. Full article
(This article belongs to the Special Issue Intraocular Pressure and Ocular Hypertension)
Show Figures

Figure 1

7 pages, 1134 KiB  
Article
Comparison of Efficacy between 120° and 180° Schlemm’s Canal Incision Microhook Ab Interno Trabeculotomy
by Naoki Okada, Kazuyuki Hirooka, Hiromitsu Onoe, Yumiko Murakami, Hideaki Okumichi and Yoshiaki Kiuchi
J. Clin. Med. 2021, 10(14), 3181; https://doi.org/10.3390/jcm10143181 - 19 Jul 2021
Cited by 27 | Viewed by 2480
Abstract
We compared surgical outcomes in patients with either primary open-angle glaucoma or exfoliation glaucoma after undergoing combined phacoemulsification with either a 120° or 180° incision during a Schlemm’s canal microhook ab interno trabeculotomy (μLOT-Phaco). This retrospective comparative case series examined 52 μLOT-Phaco eyes [...] Read more.
We compared surgical outcomes in patients with either primary open-angle glaucoma or exfoliation glaucoma after undergoing combined phacoemulsification with either a 120° or 180° incision during a Schlemm’s canal microhook ab interno trabeculotomy (μLOT-Phaco). This retrospective comparative case series examined 52 μLOT-Phaco eyes that underwent surgery between September 2017 and December 2020. Surgical qualified success was defined as an intraocular pressure (IOP) of ≤20 mmHg, ≥20% IOP reduction with IOP-lowering medications, and no additional glaucoma surgery. Success rates were evaluated by Kaplan-Meier survival analysis. The number of postoperative IOP-lowering medications and occurrence of complications were also assessed. Mean preoperative IOP in the 120° group was 16.9 ± 7.6 mmHg, which significantly decreased to 10.9 ± 2.7 mmHg (p < 0.01) and 11.1 ± 3.1 mmHg (p = 0.01) at 12 and 24 months, respectively. The mean number of preoperative IOP-lowering medications significantly decreased from 2.8 ± 1.4 to 1.4 ± 1.4 (p < 0.01) at 24 months. Mean preoperative IOP in the 180° group was 17.1 ± 7.0 mmHg, which significantly decreased to 12.1 ± 3.2 mmHg (p = 0.02) and 12.9 ± 1.4 mmHg (p = 0.01) at 12 and 24 months, respectively. The mean number of preoperative IOP-lowering medications significantly decreased from 2.9 ± 1.2 to 1.4 ± 1.5 (p < 0.01) at 24 months. The probability of qualified success at 24 months in the 120° and 180° groups was 50.4% and 54.6%, respectively (p = 0.58). There was no difference observed for hyphema formation or IOP spikes. Surgical outcomes were not significantly different between the 120° and 180° incisions in Schlemm’s canal. Full article
(This article belongs to the Special Issue Intraocular Pressure and Ocular Hypertension)
Show Figures

Figure 1

9 pages, 3489 KiB  
Article
High-Frequency Deep Sclerotomy, A Minimal Invasive Ab Interno Glaucoma Procedure Combined with Cataract Surgery: Physical Properties and Clinical Outcome
by Bojan Pajic, Zeljka Cvejic, Kaweh Mansouri, Mirko Resan and Reto Allemann
Appl. Sci. 2020, 10(1), 218; https://doi.org/10.3390/app10010218 - 27 Dec 2019
Cited by 4 | Viewed by 4242
Abstract
Background: The efficiency and safety of primary open-angle glaucoma with high-frequency deep sclerotomy (HFDS) combined with cataract surgery has to be investigated. Methods: Right after cataract surgery, HFDS was performed ab interno in 205 consecutive patients with open angle glaucoma. HFDS was performed [...] Read more.
Background: The efficiency and safety of primary open-angle glaucoma with high-frequency deep sclerotomy (HFDS) combined with cataract surgery has to be investigated. Methods: Right after cataract surgery, HFDS was performed ab interno in 205 consecutive patients with open angle glaucoma. HFDS was performed with a custom-made high-frequency disSection 19 G probe (abee tip 0.3 × 1 mm, Oertli Switzerland). The bipolar current with a frequency of 500 kHz is applied. The nasal sclera was penetrated repetitively six times through the trabecular meshwork and consecutively through Schlemm’s canal. Every time, a pocket of 0.3 mm high and 0.6 mm width was created. Results: Mean preoperative intraocular pressure (IOP) was 24.5 ± 2.1 mmHg (range 21 to 48 mmHg). After 48 months, the follow up average IOP was 15.0 ± 1.7 mmHg (range 10 to 20 mmHg). Postoperative IOP has been significantly reduced compared to preoperative IOP for all studied cases (p < 0.001). After 48 months, the target IOP less than 21 mmHg reached in 84.9%. No serious complications were observed during the surgical procedure itself and in the postoperative period. Conclusions: HFDS is a minimally invasive procedure. It is a safe and efficacious surgical technique for lowering IOP combined with cataract surgery. Full article
(This article belongs to the Special Issue Engineering for Surgery)
Show Figures

Figure 1

Back to TopTop