Next Article in Journal
Implantable Blood Pressure Sensors with Analogic Thermal Drift Compensation
Previous Article in Journal
Investigation of the Thermally Generated Au and Ag Nanoislands for SERS and LSPR Applications
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Abstract

FLIM Indicators for Quantitative Measurement of pH †

by
Tatiana R. Simonyan
1,*,
Anastasia V. Mamontova
1,
Konstantin A. Lukyanov
1 and
Alexey M. Bogdanov
2
1
Center of Life Sciences, Skolkovo Institute of Science and Technology, 121205 Moscow, Russia
2
Shemyakin-Ovchinnikov Institute of Bioorganic Chemistry, 117997 Moscow, Russia
*
Author to whom correspondence should be addressed.
Presented at the 8th International Symposium on Sensor Science, 17–28 May 2021; Available online: https://i3s2021dresden.sciforum.net/.
Published: 17 May 2021
(This article belongs to the Proceedings of The 8th International Symposium on Sensor Science)

Abstract

:
Monitoring of intracellular pH changes in situ can provide valuable information about cellular metabolism and a deeper understanding of physiological processes. Most traditional fluorescent indicators are only capable of a relative assessment of changes in the studied parameter in the cell. We associate the possibility of measuring the absolute values that characterize the analyte with the detection of the indicator signal in the time domain, where its quantitative measure is the fluorescence lifetime (tau). In this project, we test promising pH-sensitive fluorophores with labile fluorescence lifetimes—EYFP-G65T and EGFP-Y145L/S205V—both as fluorescent cores for the previously described pH indicators and as independent pH indicators. Measurement of the fluorescence attenuation kinetics of four structures (EYFP-G65T, EGFP-Y145L/S205V, SypHer3s, and SypHer3s-G65T) over a wide pH range revealed areas where tau is linearly dependent on pH. The differences in the fluorescence excitation modes of these molecules makes it possible to use them in one experimental system to assess pH changes in a wide range, 4.0–9.0. We showed that under the conditions of traditional fluorescence microscopy (in the cytoplasm of HEK293 cells), the SypHer3s-G65T indicator shows a dynamic response range approximately 3 times wider than the original SypHer3s.

Supplementary Materials

Funding

This work is supported by the Russian Foundation for Basic Research. Grant 19-34-60019.
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Share and Cite

MDPI and ACS Style

Simonyan, T.R.; Mamontova, A.V.; Lukyanov, K.A.; Bogdanov, A.M. FLIM Indicators for Quantitative Measurement of pH. Eng. Proc. 2021, 6, 33. https://doi.org/10.3390/I3S2021Dresden-10144

AMA Style

Simonyan TR, Mamontova AV, Lukyanov KA, Bogdanov AM. FLIM Indicators for Quantitative Measurement of pH. Engineering Proceedings. 2021; 6(1):33. https://doi.org/10.3390/I3S2021Dresden-10144

Chicago/Turabian Style

Simonyan, Tatiana R., Anastasia V. Mamontova, Konstantin A. Lukyanov, and Alexey M. Bogdanov. 2021. "FLIM Indicators for Quantitative Measurement of pH" Engineering Proceedings 6, no. 1: 33. https://doi.org/10.3390/I3S2021Dresden-10144

Article Metrics

Back to TopTop