Next Article in Journal
Influence of Inductive Effect in Organic Residuals Content in IZO Thin Films and the Performance on the Behavior of MIS Capacitors on Plastic
Previous Article in Journal
Fabrication of Micro-Structured Surface Topologies for the Promotion of Marine Bacteria Biofilm
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Abstract

Microswimmers for Biomedical Applications: Focus on Light †

by
Ada-Ioana Bunea
*,
Einstom Engay
,
Alexandre Emmanuel Wetzel
and
Rafael Taboryski
DTU Nanolab—National Centre for Nano Fabrication and Characterization, Technical University of Denmark, DK-2800 Kgs. Lyngby, Denmark
*
Author to whom correspondence should be addressed.
Presented at the 1st International Conference on Micromachines and Applications, 15–30 April 2021; Available online: https://micromachines2021.sciforum.net/.
Published: 16 April 2021
(This article belongs to the Proceedings of The 1st International Conference on Micromachines and Applications)
Microswimmers are microscopic objects that can move and perform tasks in liquid environments. Although only two decades have passed since their emergence [1], microswimmers have already attracted significant attention in the scientific world because of their many valuable potential applications. Among these, biomedical applications seem particularly promising, and many interesting studies have been performed already in vitro or even in vivo [2]. However, no microswimmers have so far been approved for clinical use, which is why ongoing research is often focused on clinical translation or relevant related issues such as biocompatibility. Different propulsion and control modalities are employed for microswimmers, including biohybrid, optical, magnetic, chemical, thermal or acoustic propulsion. Among these, our group focuses on the use of optical forces generated by manipulating light. For most intents and purposes, light is a biocompatible actuator. However, because of the limited tissue penetration depth, light is only suited for applications in superficial tissues of the human body [3]. On the other hand, light-controlled microswimmers can be employed for various laboratory studies relevant for biomedical research, such as cell manipulation, fluid viscosity characterization, or drug delivery. Furthermore, supplementing the use of light with that of, e.g., a magnetic actuator can help overcome the challenges encountered in the human body [4]. Light is a flexible actuator which can be tailored to the desired application. When it comes to light-controlled microswimmers, one option is to use focused near-infrared laser beams for optical trapping. This enables extremely precise manipulation of the microswimmers with six degrees of freedom. Another option is to use visible light to induce shape changes in light-responsive polymers in a controlled manner. Both options are interesting for biomedical applications and have characteristic advantages and challenges [5]. Designing and fabricating light-controlled microswimmers currently needs tailoring to specific applications, which often requires interdisciplinary teams of highly trained researchers [6]. Ultimately, gathering sufficient knowledge and overcoming the existing challenges in the field should enable the development of a toolbox of light-controlled microswimmers readily available for various biomedical studies.

Supplementary Materials

Acknowledgments

A.-I. Bunea acknowledges financial support from Villum Fonden (grant number 34424). E. Engay acknowledges financial support from Villum Fonden (grant number 00022918). A. E. Wetzel acknowledges financial support from Novo Nordisk Fonden (grant number NNF16OC0021948).

References

  1. Ozin, G.A.; Manners, I.; Fournier-Bidoz, S.; Arsenault, A. Dream Nanomachines. Adv. Mater. 2005, 17, 3011. [Google Scholar] [CrossRef]
  2. Bunea, A.I.; Taboryski, R. Recent Advances in Microswimmers for Biomedical Applications. Micromachines 2020, 11, 1048. [Google Scholar] [CrossRef] [PubMed]
  3. Bunea, A.I.; Glückstad, J. Strategies for Optical Trapping in Biological Samples: Aiming at Microrobotic Surgeons. Laser Photon. Rev. 2019, 13, 1800227. [Google Scholar] [CrossRef]
  4. Sitti, M.; Wiersma, D.S. Pros and Cons: Magnetic versus Optical Microrobots. Adv. Mater. 2020, 32, 1906766. [Google Scholar] [CrossRef] [PubMed]
  5. Bunea, A.I.; Martella, D.; Nocentini, S.; Parmeggiani, C.; Taboryski, R.; Wiersma, D.S. Light-Powered Microrobots: Challenges and Opportunities for Hard and Soft Responsive Microswimmers. Adv. Intell. Syst. 2021. [Google Scholar] [CrossRef]
  6. Nocentini, S.; Parmeggiani, C.; Martella, D.; Wiersma, D.S. Optically Driven Soft Micro Robotics. Adv. Optical Mater. 2018, 6, 1800207. [Google Scholar] [CrossRef]
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Share and Cite

MDPI and ACS Style

Bunea, A.-I.; Engay, E.; Wetzel, A.E.; Taboryski, R. Microswimmers for Biomedical Applications: Focus on Light. Eng. Proc. 2021, 4, 8. https://doi.org/10.3390/Micromachines2021-09578

AMA Style

Bunea A-I, Engay E, Wetzel AE, Taboryski R. Microswimmers for Biomedical Applications: Focus on Light. Engineering Proceedings. 2021; 4(1):8. https://doi.org/10.3390/Micromachines2021-09578

Chicago/Turabian Style

Bunea, Ada-Ioana, Einstom Engay, Alexandre Emmanuel Wetzel, and Rafael Taboryski. 2021. "Microswimmers for Biomedical Applications: Focus on Light" Engineering Proceedings 4, no. 1: 8. https://doi.org/10.3390/Micromachines2021-09578

Article Metrics

Back to TopTop