Previous Article in Journal
Machine Learning and Deep Learning for Wildfire Prediction: A Systematic and Bibliometric Review of Methods, Data Practices, and Reproducibility (2020–2025)
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
This is an early access version, the complete PDF, HTML, and XML versions will be available soon.
Article

Simplified Post-Fire Structural Performance of Biaxial Voided Reinforced Concrete Slabs: Influence of Void Geometry

by
Nursel Kütük
* and
Mustafa Özakça
*
Department of Civil Engineering, Gaziantep University, Gaziantep 27310, Turkey
*
Authors to whom correspondence should be addressed.
Fire 2026, 9(5), 205; https://doi.org/10.3390/fire9050205
Submission received: 6 April 2026 / Revised: 7 May 2026 / Accepted: 8 May 2026 / Published: 15 May 2026

Abstract

Reinforced concrete (RC) slabs with internal voids are increasingly used to improve material efficiency; however, their residual structural performance after fire exposure remains insufficiently understood. This study presents a numerical investigation of RC slabs with different void geometries using a three-dimensional nonlinear Finite Element (FE) model. A sequential thermal–structural approach was adopted, in which fire exposure was simulated through transient thermal analysis, and the resulting spatial distribution of maximum temperatures was used to assign residual material properties to each FE based on its local peak temperature, followed by structural analysis under ambient conditions. A parametric study was conducted on seven slab configurations, including two solid slabs and five voided slabs with spherical, elliptical, ellipsoidal, capsule, and biaxial capsule geometries. To ensure a consistent evaluation, two reference solid slabs were considered: a 230 mm thick slab to enable comparison under identical geometric conditions, and a 160 mm thick slab representing equivalent concrete volume to assess material efficiency. Fire exposure was applied according to the ISO 834 standard fire curve for durations of 30, 60, and 90 min. The results indicate that voided slabs exhibit higher deflections than the solid slab of identical thickness due to reduced stiffness, while achieving comparable performance relative to the solid slab with equivalent concrete volume. These findings highlight the trade-off between structural stiffness and material efficiency under increasing fire exposure time.
Keywords: fire exposure; voided slab systems; reinforced concrete slabs; post-fire behavior; thermo-structural analysis; finite element analysis fire exposure; voided slab systems; reinforced concrete slabs; post-fire behavior; thermo-structural analysis; finite element analysis

Share and Cite

MDPI and ACS Style

Kütük, N.; Özakça, M. Simplified Post-Fire Structural Performance of Biaxial Voided Reinforced Concrete Slabs: Influence of Void Geometry. Fire 2026, 9, 205. https://doi.org/10.3390/fire9050205

AMA Style

Kütük N, Özakça M. Simplified Post-Fire Structural Performance of Biaxial Voided Reinforced Concrete Slabs: Influence of Void Geometry. Fire. 2026; 9(5):205. https://doi.org/10.3390/fire9050205

Chicago/Turabian Style

Kütük, Nursel, and Mustafa Özakça. 2026. "Simplified Post-Fire Structural Performance of Biaxial Voided Reinforced Concrete Slabs: Influence of Void Geometry" Fire 9, no. 5: 205. https://doi.org/10.3390/fire9050205

APA Style

Kütük, N., & Özakça, M. (2026). Simplified Post-Fire Structural Performance of Biaxial Voided Reinforced Concrete Slabs: Influence of Void Geometry. Fire, 9(5), 205. https://doi.org/10.3390/fire9050205

Article Metrics

Back to TopTop