Can We Trust Inertial and Heart Rate Sensor Data from an APPLE Watch Device? †
Abstract
:1. Introduction
2. Methods
2.1. Instrumentation and Device Data Acquisition
2.2. Participants and Protocol
2.3. Statistical Analysis
- 1)
- Mean values for step counting and heart rate monitoring using bar charts.
- 2)
- Correlation analysis of raw data using Pearson’s correlation coefficient to examine the strength of the relationship between the Apple watch and the benchmark devices.
- 3)
- Bland–Altman analysis [14] was used to assess more accurately the level of agreement between the Apple watch and the benchmark devices. The difference between two sets of data and the average between them was determined. In addition, the mean bias (mean of the difference), and upper and lower Limits of Agreement (LoA) were included in the results.
3. Results
3.1. Step Counting Measurements
3.2. Heart Rate Measurements
4. Conclusions
Conflicts of Interest
References
- Wartburton, D.E.; Nicol, C.W.; Bredin, S.S. Health benefits of physical activity: The evidence. CMAJ 2006, 174, 801–809. [Google Scholar] [CrossRef] [PubMed]
- Tuso, P. Strategies to increase physical activity. Perm J. 2015, 19, 84–88. [Google Scholar] [CrossRef] [PubMed]
- Espinosa, H.G.; Shepherd, J.B.; Thiel, D.V.; Worsey, M.T.O. Anytime, anywhere! Inertial sensors monitor sports performance. IEEE Potentials. 2019, 38, 11–16. [Google Scholar] [CrossRef]
- Canalys, North American Wearable Band Shipments and Annual Growth. Available online: https://www.canalys.com/newsroom/north-america-wearables-q2-2019 (accessed on 11 November 2019).
- Thomson, E.A.; Nuss, K.; Comstock, A.; Reinwald, S.; Blake, S.; Pimentel, R.E.; Tracy, B.L.; Li, K. Heart rate measures from the Apple Watch, Fitbit Charge HR 2, and electrocardiogram across different exercise intensities. J. Sports Sci. 2019, 37, 1411–1419. [Google Scholar] [CrossRef] [PubMed]
- Bai, Y.; Hibbing, P.; Mantis, C.; Welk, G.J. Comparative evaluation of heart rate-based monitors: Apple Watch vs. Fitbit Charge HR. J. Sports Sci. 2018, 36, 1734–1741. [Google Scholar] [CrossRef] [PubMed]
- Gillinov, S.; Etiwy, M.; Wang, R.; Blackburn, G.; Phelan, D.; Gillinov, A.M.; Houghtaling, P.; Javadikasgari, H.; Desai, M.Y. Variable accuracy of wearable heart rate monitors during aerobic exercise. Med. Sci. Sports Exerc. 2017, 49, 1697–1703. [Google Scholar] [CrossRef] [PubMed]
- Tam, K.M.; Cheung, S.Y. Validation of electronic activity monitor devices during treadmill walking. Telemed. e-Health 2018, 24, 782–789. [Google Scholar] [CrossRef] [PubMed]
- Degroote, L.; De Bourdeaudhuij, I.; Verloigne, M.; Poppe, L.; Crombez, G. The accuracy of smart devices for measuring physical activity in daily life: Validation study. JMIR mHealth uHealth 2018, 6, e10972. [Google Scholar] [CrossRef] [PubMed]
- Imboden, M.T.; Nelson, M.B.; Kaminsky, L.A.; Montoye, A.H. Comparison of four Fitbit and Jawbone activity monitors with a research-grade ActiGraph accelerometer for estimating physical activity and energy expenditure. Br. J. Sports Med. 2018, 52, 844–850. [Google Scholar] [CrossRef] [PubMed]
- Espinosa, H.G.; Lee, J.; James, D.A. The inertial sensor: A base platform for wider adoption in sports science applications. J. Fitness Res. 2015, 4, 1–8. [Google Scholar]
- Thiel, D.V.; Shepherd, J.; Espinosa, H.G.; Kenny, M.; Fischer, K.; Worsey, M.; Matsuo, A.; Wada, T. Predicting ground reaction forces in sprint running using a shank mounted inertial measurement unit. Proceedings 2018, 2, 199. [Google Scholar]
- Fitzpatrick, T.B. The validity and practicality of sun-reactive skin types I through VI. Arch. Dermatol. 1988, 124, 869–871. [Google Scholar] [CrossRef] [PubMed]
- Bland, J.M.; Altman, D.G. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986, 327, 307–310. [Google Scholar] [CrossRef]
- Espinosa, H.G.; Nordsborg, N.; Thiel, D.V. Front crawl swimming analysis using accelerometers: A preliminary comparison between pool and flume. Procedia Eng. 2015, 112, 497–501. [Google Scholar] [CrossRef]
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations. |
© 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
Share and Cite
Espinosa, H.G.; Thiel, D.V.; Sorell, M.; Rowlands, D. Can We Trust Inertial and Heart Rate Sensor Data from an APPLE Watch Device? Proceedings 2020, 49, 128. https://doi.org/10.3390/proceedings2020049128
Espinosa HG, Thiel DV, Sorell M, Rowlands D. Can We Trust Inertial and Heart Rate Sensor Data from an APPLE Watch Device? Proceedings. 2020; 49(1):128. https://doi.org/10.3390/proceedings2020049128
Chicago/Turabian StyleEspinosa, Hugo G., David V. Thiel, Matthew Sorell, and David Rowlands. 2020. "Can We Trust Inertial and Heart Rate Sensor Data from an APPLE Watch Device?" Proceedings 49, no. 1: 128. https://doi.org/10.3390/proceedings2020049128
APA StyleEspinosa, H. G., Thiel, D. V., Sorell, M., & Rowlands, D. (2020). Can We Trust Inertial and Heart Rate Sensor Data from an APPLE Watch Device? Proceedings, 49(1), 128. https://doi.org/10.3390/proceedings2020049128