Next Article in Journal
Temporal Progression of Aortic Valve Pathogenesis in a Mouse Model of Osteogenesis Imperfecta
Previous Article in Journal
Maturation and Function of the Intercalated Disc: Report of Two Pediatric Cases Focusing on Cardiac Development and Myocardial Hyperplasia
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

Tricuspid Regurgitation (TR) after Implantation of a Cardiac Implantable Electronic Device (CIED)—One-Year Observation of Patients with or without Left Ventricular Dysfunction

by
Karolina Chodór-Rozwadowska
1,2,*,
Magdalena Sawicka
3,4,
Stanisław Morawski
5,
Zbigniew Kalarus
2 and
Tomasz Kukulski
6
1
Doctoral School, Department of Cardiology, Congenital Heart Diseases and Electrotherapy, Silesian Center for Heart Diseases, Faculty of Medical Sciences in Zabrze, Medical University of Silesia, 40-055 Katowice, Poland
2
Department of Cardiology, Congenital Heart Diseases and Electrotherapy, Medical University of Silesia, 40-055 Katowice, Poland
3
Department of Cardiac, Vascular and Endovascular Surgery and Transplantology, Silesian Center for Heart Diseases, Maria Skłodowska—Curie 9 Street, 41-800 Zabrze, Poland
4
Department of Cardiac Transplantation and Mechanical Circulatory Support, Silesian Center for Heart Diseases, Maria Skłodowska—Curie 9 Street, 41-800 Zabrze, Poland
5
Department of Cardiology, Silesian Centre for Heart Diseases, 41-800 Zabrze, Poland
6
2nd Department of Cardiology, Medical University of Silesia, Katowice Poland, Spec. Hospital, 41-808 Zabrze, Poland
*
Author to whom correspondence should be addressed.
J. Cardiovasc. Dev. Dis. 2023, 10(8), 353; https://doi.org/10.3390/jcdd10080353
Submission received: 24 July 2023 / Revised: 14 August 2023 / Accepted: 16 August 2023 / Published: 19 August 2023

Abstract

The frequency of tricuspid regurgitation (TR) progression after cardiac implantable electronic devices (CIEDs) implantation varies from 7.2% to 44.7%. TR is associated with increased mortality and hospitalizations due to heart failure (HF) decompensation. The aim of this study was to assess the rate of early TR progression after CIED implantation and the frequency of HF decompensation and mortality. The 101 patients, who received a CIED between March 2020 and October 2021, before the procedure were divided into two groups–one with left ventricle ejection fraction (LVEF) ≥ 40% (n = 60) and one with LVEF < 40% (n = 41). Lead-related tricuspid regurgitation (LRTR) was defined as an increase of TR by at least one grade. The follow-up period was similar between both groups and was on average 13 (12–16) months. In the whole study group, TR progression by one grade was 34.6% and by two or more grades 15.8%. The significant changes in the dynamic of TR degree were as follows before and after implantation: none/trivial TR in group 1 (61.7% vs. 28.3%, p = 0.01) and severe/massive TR in group 2 (0.0% vs. 14.6%, p = 0.03). The groups did not differ from each other in terms of survival from decompensation of HF (18.3% vs. 36.6%, p = 0.70) and survival from death (1.7% vs. 4.9%, p = 0.16). At the one-year follow-up, the baseline LVEF did not affect the survival rate from death or HF decompensation among patients with a progression of TR after CIED implantation. In this study, a progression by one grade was more common in group 1, but the occurrence of severe/massive TR after implantation was more specific for group 2.
Keywords: tricuspid regurgitation; cardiac implantable electronic device; heart failure tricuspid regurgitation; cardiac implantable electronic device; heart failure

Share and Cite

MDPI and ACS Style

Chodór-Rozwadowska, K.; Sawicka, M.; Morawski, S.; Kalarus, Z.; Kukulski, T. Tricuspid Regurgitation (TR) after Implantation of a Cardiac Implantable Electronic Device (CIED)—One-Year Observation of Patients with or without Left Ventricular Dysfunction. J. Cardiovasc. Dev. Dis. 2023, 10, 353. https://doi.org/10.3390/jcdd10080353

AMA Style

Chodór-Rozwadowska K, Sawicka M, Morawski S, Kalarus Z, Kukulski T. Tricuspid Regurgitation (TR) after Implantation of a Cardiac Implantable Electronic Device (CIED)—One-Year Observation of Patients with or without Left Ventricular Dysfunction. Journal of Cardiovascular Development and Disease. 2023; 10(8):353. https://doi.org/10.3390/jcdd10080353

Chicago/Turabian Style

Chodór-Rozwadowska, Karolina, Magdalena Sawicka, Stanisław Morawski, Zbigniew Kalarus, and Tomasz Kukulski. 2023. "Tricuspid Regurgitation (TR) after Implantation of a Cardiac Implantable Electronic Device (CIED)—One-Year Observation of Patients with or without Left Ventricular Dysfunction" Journal of Cardiovascular Development and Disease 10, no. 8: 353. https://doi.org/10.3390/jcdd10080353

APA Style

Chodór-Rozwadowska, K., Sawicka, M., Morawski, S., Kalarus, Z., & Kukulski, T. (2023). Tricuspid Regurgitation (TR) after Implantation of a Cardiac Implantable Electronic Device (CIED)—One-Year Observation of Patients with or without Left Ventricular Dysfunction. Journal of Cardiovascular Development and Disease, 10(8), 353. https://doi.org/10.3390/jcdd10080353

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop