Spatial Distribution of Overhead Power Lines and Underground Cables in Germany in 2016
Abstract
:1. Summary
2. Data Description
- Line data of the overhead power lines for Germany; and
- Line data of the underground cables for Germany.
- medium voltage ≥1 and <72.5 kV;
- high voltage ≥72.5 and <125 kV; and
- maximum voltage ≥125 kV
3. Methods
3.1. Data Source and Accesibility
3.2. Data Generation Process
3.3. Resulting Dataset and Validation
4. User Notes
Supplementary Materials
Supplementary File 1Author Contributions
Funding
Acknowledgments
Conflicts of Interest
References
- Bernardino, J.; Bevanger, K.; Barrientos, R.; Dwyer, J.F.; Marques, A.T.; Martins, R.C.; Shaw, J.M.; Silva, J.P.; Moreira, F. Bird collisions with power lines: State of the art and priority areas for research. Biol. Conserv. 2018, 222, 1–13. [Google Scholar] [CrossRef]
- Biasotto, L.D.; Kindel, A. Power lines and impacts on biodiversity: A systematic review. Environ. Impact Assess. Rev. 2018, 71, 110–119. [Google Scholar] [CrossRef]
- Slednev, V.; Bertsch, V.; Ruppert, M.; Fichtner, W. Highly resolved optimal renewable allocation planning in power systems under consideration of dynamic grid topology. Comput. Oper. Res. 2018, 96, 281–293. [Google Scholar] [CrossRef] [Green Version]
- Razeghi, G.; Brouwer, J.; Samuelsen, S. A spatially and temporally resolved model of the electricity grid—Economic vs environmental dispatch. Appl. Energy 2016, 178, 540–556. [Google Scholar] [CrossRef]
- Tempesta, T.; Vecchiato, D.; Girardi, P. The landscape benefits of the burial of high voltage power lines: A study in rural areas of Italy. Landsc. Urban Plan. 2014, 126, 53–64. [Google Scholar] [CrossRef]
- Bruns, E.; Koch, S.; Bauer, J.; Kraetzschmer, D.; Sicard, J.-C.; Garske, S.; Hofmann, L. Auswirkungen Zukünftiger Netzinfrastrukturen und Energiespeicher in Deutschland und Europa; Bundesamt für Naturschutz BfN: Bonn, Germany, 2015. (In German) [Google Scholar]
- Weingarten, E.; Peters, W.; Kinast, P.; Wachter, T.F. Methodik der trassenkorridorplanung bei der bundesfachplanung. In Proceedings of the Automated Vehicles Symposium, San Francisco, CA, USA, 9–12 July 2018; pp. 116–124. [Google Scholar]
- Peters, W.; Weingarten, E.; Koch, H.-J.; Prall, U.; Vollprecht, J.; Westermann, D.; Marten, A.-K. Umweltbelange und Raumbezogene Erfordernisse bei der Planung des Ausbaus des Höchstspannungs-Übertragungsnetzes; Umweltbundesamt: Dessau-Roßlau, Germany, 2014. (In German) [Google Scholar]
- Runge, K.; Meister, P.; Rottgardt, E. Bmu-Studie: Ökologische Auswirkungen von 380-kv-Erdleitungen und Hgü-Erdleitungen, Band 2: Bericht der Arbeitsgruppe Umwelt. Schriftenreihe des Energie-Forschungszentrums Niedersachsen (efzn); Cuvillier Verlag: Göttingen, Germany, 2012. (In German) [Google Scholar]
- Kemfert, C.; Kunz, F.; Rosellón, J. A welfare analysis of electricity transmission planning in Germany. Energy Policy 2016, 94, 446–452. [Google Scholar] [CrossRef]
- Medjroubi, W.; Müller, U.P.; Scharf, M.; Matke, C.; Kleinhans, D. Open data in power grid modelling: New approaches towards transparent grid models. Energy Rep. 2017, 3, 14–21. [Google Scholar] [CrossRef]
- BKG. Amtliches Topographisch-Kartographisches Informationssystem, Digitales Basis-Landschaftsmodell (Basis-dlm, aaa-Modellierung) Datenbestände der Arbeitsgemeinschaft der Vermessungsverwaltungen der länder der Bundesrepublik Deutschland, ©geobasis-de/bkg. Geodäsie, B.f.K.u. Available online: http://www.adv-online.de/AAA-Modell/ATKIS/ (accessed on 6 September 2018).
- BNetzA. Eeg in Zahlen bzw. Statistikbericht eeg—Jahresabrechnung; Bundesnetzagentur für Elektrizität, Gas, Telekommunikation, Post und Eisenbahnen (BNetzA): Bonn, Germany, 2016. (In German) [Google Scholar]
- UFZ_DMP. Spatial Distribution of Overhead Power Lines and Underground Cables in Germany in 2016. Available online: http://www.ufz.de/record/dmp/archive/5368 (accessed on 6 June 2018).
- Louis, J.-N.; Allard, S.; Debusschere, V.; Mima, S.; Tran-Quoc, T.; Hadjsaid, N. Environmental impact indicators for the electricity mix and network development planning towards 2050—A poles and eutgrid model. Energy 2018, 163, 618–628. [Google Scholar] [CrossRef]
- BDEW. Entwicklung der Stromnetze in Deutschland. Available online: https://www.bdew.de/service/daten-und-grafiken/entwicklung-stromnetze-deutschland (accessed on 6 June 2018).
- BNetzA. Monitoringbericht 2016; Bundesnetzagentur für Elektrizität, Gas, Telekommunikation, Post und Eisenbahnen (BNetzA): Bonn, Germany, 2016. (In German) [Google Scholar]
- OSM. Overhead Lines und Underground Cables. © Openstreetmap Contributors, Open Database License (ODbL). Available online: https://www.openstreetmap.org/copyright (accessed on 6 September 2018).
- STATISTA. Länge des Stromnetzes in Deutschland nach Spannungsebene im Jahresvergleich 2010 und 2016 (in 1.000 kilometern). Available online: https://de.statista.com/statistik/daten/studie/37962/umfrage/laenge-der-stromnetze-in-deutschland-in-1998-und-2008/ (accessed on 6 June 2018).
- EEA. Environmental Indicators: Typology and Overview; European Environment Agency: Copenhagen, Denmark, 1999. [Google Scholar]
- Martin, G.R.; Shaw, J.M. Bird collisions with power lines: Failing to see the way ahead? Biol. Conserv. 2010, 143, 2695–2702. [Google Scholar] [CrossRef]
- Haubaum, V.C.; Roth, M. Gis-gestützte sichtbarkeitsanalysen von hochspannungsleitungen: Grundlage zur landschaftsästhetischen beurteilung von energietrassen. Naturschutz Und Landschaftsplanung 2015, 47, 209–214. [Google Scholar]
Level of Voltage | Route Length (km) |
---|---|
medium voltage ≥1 kV and <72.5 kV | 18,933 |
high voltage ≥72.5 and <125 kV | 42,679 |
maximum voltage ≥125 kV | 18,246 |
Data Source | Type of Cable | Medium Voltage | High Voltage | Maximum Voltage | Total |
---|---|---|---|---|---|
BDEW [16] | Overhead line | 108,968 | 72,527 | 35,012 | 216,507 |
Underground cables | 405,032 | 7173 | 176 | 412,381 | |
Total | 514,000 | 79,700 | 35,188 | 628,888 | |
BNetzA [17] | Overhead line | NA | NA | NA | NA |
Underground cables | NA | NA | NA | NA | |
Total | 511,164 | 96,658 | 35,970 | 643,792 | |
OSM [18] | Overhead line | 16,017 | 82,884 | 37,062 | 135,963 |
Underground cables | 959 | 1124 | 268 | 2351 | |
Total | 16,976 | 84,008 | 37,330 | 104,717 |
© 2018 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
Share and Cite
Eichhorn, M.; Thylmann, M.; Peters, W.; Kinast, P.; Thrän, D.; Bauschmann, M.; Seitz, S.; Ponitka, J. Spatial Distribution of Overhead Power Lines and Underground Cables in Germany in 2016. Data 2018, 3, 34. https://doi.org/10.3390/data3030034
Eichhorn M, Thylmann M, Peters W, Kinast P, Thrän D, Bauschmann M, Seitz S, Ponitka J. Spatial Distribution of Overhead Power Lines and Underground Cables in Germany in 2016. Data. 2018; 3(3):34. https://doi.org/10.3390/data3030034
Chicago/Turabian StyleEichhorn, Marcus, Miron Thylmann, Wolfgang Peters, Pascal Kinast, Daniela Thrän, Martin Bauschmann, Stefanie Seitz, and Jens Ponitka. 2018. "Spatial Distribution of Overhead Power Lines and Underground Cables in Germany in 2016" Data 3, no. 3: 34. https://doi.org/10.3390/data3030034