Effect of Spectral Filtering and Segmental X-ray Tube Current Switch-Off on Interventionalist’s Scatter Exposure during CT Fluoroscopy
Abstract
:1. Introduction
2. Materials and Methods
2.1. Two-Dimensional Fluoro-CT
2.2. Exposure to Scattered Radiation
2.3. Patient Exposure
2.4. Statistics
3. Results
3.1. Effect of Using a Sn Filter
3.2. Effect of Combining Sn Filter with PACT
3.3. Patients’ CT Exposure
4. Discussion
5. Conclusions
Author Contributions
Funding
Institutional Review Board Statement
Informed Consent Statement
Data Availability Statement
Acknowledgments
Conflicts of Interest
References
- Schoenberg, S.O.; Attenberger, U.I.; Solomon, S.B.; Weissleder, R. Developing a Roadmap for Interventional Oncology. Oncologist 2018, 23, 1162–1170. [Google Scholar] [CrossRef]
- Sarti, M.; Brehmer, W.P.; Gay, S.B. Low-Dose Techniques in CT-Guided Interventions. Radiographics 2012, 32, 1109–1119. [Google Scholar] [CrossRef]
- ICRP. Statement on Tissue Reactions—ICRP Ref 4825-3093-1464; ICRP: Stockholm, Sweden, 2011. [Google Scholar]
- ICRP. ICRP Publication 103—The 2007 Recommendations of the International Commission on Radiological Protection; Annals of the ICRP 2007; ICRP: Stockholm, Sweden, 2007; pp. 1–35. [Google Scholar]
- Tsapaki, V. Radiation Dose Optimization in Diagnostic and Interventional Radiology: Current Issues and Future Perspectives. Phys. Medica 2020, 79, 16–21. [Google Scholar] [CrossRef]
- Rogits, B.; Jungnickel, K.; Loewenthal, D.; Kropf, S.; Nekolla, E.; Dudeck, O.; Pech, M.; Wieners, G.; Ricke, J. Prospective Evaluation of the Radiologist’s Hand Dose in CT-Guided Interventions. RoeFo 2013, 185, 1081–1088. [Google Scholar] [CrossRef]
- Grosser, O.S.; Wybranski, C.; Kupitz, D.; Powerski, M.; Mohnike, K.; Pech, M.; Amthauer, H.; Ricke, J. Improvement of Image Quality and Dose Management in CT Fluoroscopy by Iterative 3D Image Reconstruction. Eur. Radiol. 2017, 27, 3625–3634. [Google Scholar] [CrossRef]
- Stoeckelhuber, B.M.; Leibecke, T.; Schulz, E.; Melchert, U.H.; Bergmann-Koester, C.U.; Helmberger, T.; Gellissen, J. Radiation Dose to the Radiologist’s Hand During Continuous CT Fluoroscopy-Guided Interventions. Cardiovasc. Interv. Radiol. 2005, 28, 589–594. [Google Scholar] [CrossRef]
- Kikuchi, K.; Takaki, H.; Matsumoto, K.; Kobayashi, K.; Kako, Y.; Kodama, H.; Ogasawara, A.; Taniguchi, J.; Takahagi, M.; Hagihara, Y.; et al. Radioprotective Effects of a Semicircular X-ray Shielding Device for Operators During CT Fluoroscopy-Guided Interventional Procedures: Experimental and Clinical Studies. Cardiovasc. Interv. Radiol. 2023, 46, 770–776. [Google Scholar] [CrossRef]
- Dankerl, P.; May, M.S.; Canstein, C.; Uder, M.; Saake, M. Cutting Staff Radiation Exposure and Improving Freedom of Motion during CT Interventions: Comparison of a Novel Workflow Utilizing a Radiation Protection Cabin versus Two Conventional Workflows. Diagnostics 2021, 11, 1099. [Google Scholar] [CrossRef]
- Knott, E.A.; Rose, S.D.; Wagner, M.G.; Lee, F.T.; Radtke, J.; Anderson, D.R.; Zlevor, A.M.; Lubner, M.G.; Hinshaw, J.L.; Szczykutowicz, T.P. CT Fluoroscopy for Image-Guided Procedures: Physician Radiation Dose During Full-Rotation and Partial-Angle CT Scanning. J. Vasc. Interv. Radiol. 2021, 32, 439–446. [Google Scholar] [CrossRef] [PubMed]
- Carlson, S.K.; Bender, C.E.; Classic, K.L.; Zink, F.E.; Quam, J.P.; Ward, E.M.; Oberg, A.L. Benefits and Safety of CT Fluoroscopy in Interventional Radiologic Procedures. Radiology 2001, 219, 515–520. [Google Scholar] [CrossRef] [PubMed]
- Sarmento, S.; Pereira, J.S.; Sousa, M.J.; Cunha, L.T.; Dias, A.G.; Pereira, M.F.; Oliveira, A.D.; Cardoso, J.V.; Santos, L.M.; Santos, J.A.M.; et al. The Use of Needle Holders in CTF Guided Biopsies as a Dose Reduction Tool. J. Appl. Clin. Med. Phys. 2017, 19, 250–258. [Google Scholar] [CrossRef] [PubMed]
- Hohl, C.; Suess, C.; Wildberger, J.E.; Honnef, D.; Das, M.; Muehlenbruch, G.; Schaller, A.; Guenther, R.W.; Mahnken, A.H. Dose Reduction during CT Fluoroscopy: Phantom Study of Angular Beam Modulation. Radiology 2008, 246, 519–525. [Google Scholar] [CrossRef] [PubMed]
- Keisuke, T.; Atsushi, U.; Tsukasa, Y.; Yoshihiro, N.; Masahiro, E.; Takeshi, A. Radiation dose and image quality of CT fluoroscopy with partial exposure mode. Diagn. Interv. Radiol. 2020, 26, 333–338. [Google Scholar] [CrossRef]
- Greffier, J.; Pereira, F.; Hamard, A.; Addala, T.; Beregi, J.P.; Frandon, J. Effect of Tin Filter-Based Spectral Shaping CT on Image Quality and Radiation Dose for Routine Use on Ultralow-Dose CT Protocols: A Phantom Study. Diagn. Interv. Imag. 2020, 101, 373–381. [Google Scholar] [CrossRef] [PubMed]
- McCollough, C.H.; Leng, S.; Yu, L.; Fletcher, J.G. Dual- and Multi-Energy CT: Principles, Technical Approaches, and Clinical Applications. Radiology 2015, 276, 637–653. [Google Scholar] [CrossRef] [PubMed]
- Suntharalingam, S.; Mikat, C.; Wetter, A.; Guberina, N.; Salem, A.; Heil, P.; Forsting, M.; Nassenstein, K. Whole-Body Ultra-Low Dose CT Using Spectral Shaping for Detection of Osteolytic Lesion in Multiple Myeloma. Eur. Radiol. 2018, 28, 2273–2280. [Google Scholar] [CrossRef]
- Faby, S.; Kuchenbecker, S.; Sawall, S.; Simons, D.; Schlemmer, H.; Lell, M.; Kachelrieß, M. Performance of Today’s Dual Energy CT and Future Multi Energy CT in Virtual Non-contrast Imaging and in Iodine Quantification: A Simulation Study. Med. Phys. 2015, 42, 4349–4366. [Google Scholar] [CrossRef]
- Albrecht, M.H.; Scholtz, J.-E.; Kraft, J.; Bauer, R.W.; Kaup, M.; Dewes, P.; Bucher, A.M.; Burck, I.; Wagenblast, J.; Lehnert, T.; et al. Assessment of an Advanced Monoenergetic Reconstruction Technique in Dual-Energy Computed Tomography of Head and Neck Cancer. Eur. Radiol. 2015, 25, 2493–2501. [Google Scholar] [CrossRef] [PubMed]
- Uhrig, M.; Simons, D.; Kachelrieß, M.; Pisana, F.; Kuchenbecker, S.; Schlemmer, H.-P. Advanced Abdominal Imaging with Dual Energy CT Is Feasible without Increasing Radiation Dose. Cancer Imaging 2016, 16, 15. [Google Scholar] [CrossRef]
- Klein, O.; Nishina, Y. Über Die Streuung von Strahlung Durch Freie Elektronen Nach Der Neuen Relativistischen Quantendynamik von Dirac. Z. Phys. 1929, 52, 853–868. [Google Scholar] [CrossRef]
- Siemens Healthineers. CARE Vision CT with HandCARE and CARE View—White Paper 2009; Siemens Healthineers: Erlangen, Germany, 2009. [Google Scholar]
- IEC 60601-2-44; Medical Electrical Equipment—Part 2-44: Particular Requirements for the Basic Safety and Essential Performance of X-ray Equipment for Computed Tomography 2009. IEC: Geneva, Switzerland, 2009.
- ICRP. Managing Patient Dose in Multi-Detector Computed Tomography (MDCT); ICRP Publication 102; ICRP: Stockholm, Sweden, 2007. [Google Scholar]
- Podgoršak, E.B. Radiation Physics for Medical Physicists, 3rd ed.; Springer International Publishing: Cham, Switzerland, 2016; pp. 311–313. [Google Scholar]
- Mahnken, A.H.; Sedlmair, M.; Ritter, C.; Banckwitz, R.; Flohr, T. Efficacy of Lower-Body Shielding in Computed Tomography Fluoroscopy-Guided Interventions. Cardiovasc. Interv. Radiol. 2012, 35, 1475–1479. [Google Scholar] [CrossRef]
- NCRP. Structural Shielding Design for Medical X-Ray Imaging Facilities; NCRP Report No. 147; NCRP: Bethesda, MD, USA, 2005. [Google Scholar]
- Wallace, H.; Martin, C.J.; Sutton, D.G.; Peet, D.; Williams, J.R. Establishment of scatter factors for use in shielding calculations and risk assessment for computed tomography facilities. J. Radiol. Prot. 2012, 32, 39–50. [Google Scholar] [CrossRef]
- Edwards, S.M.; Schick, D. Comparative analysis of patient scatter to phantom scatter for computed tomography systems. Phys. Eng. Sci. Med. 2022, 45, 883–888. [Google Scholar] [CrossRef]
- Inaba, Y.; Hitachi, S.; Watanuki, M.; Chida, K. Occupational Radiation Dose to Eye Lenses in CT-Guided Interventions Using MDCT-Fluoroscopy. Diagnostics 2021, 11, 646. [Google Scholar] [CrossRef]
- Mahnken, A.H.; Seoane, E.B.; Cannavale, A.; de Haan, M.W.; Dezman, R.; Kloeckner, R.; O’Sullivan, G.; Ryan, A.; Tsoumakidou, G. CIRSE Clinical Practice Manual. Cardiovasc. Interv. Radiol. 2021, 44, 1323–1353. [Google Scholar] [CrossRef]
- Koch, A.; Gruber-Rouh, T.; Zangos, S.; Eichler, K.; Vogl, T.; Basten, L. Radiation protection in CT-guided interventions: Does real-time dose visualisation lead to a reduction in radiation dose to participating radiologists? A single-centre evaluation. Clin. Radiol. 2024, 79, e785–e790. [Google Scholar] [CrossRef] [PubMed]
- Theilig, D.; Mayerhofer, A.; Petschelt, D.; Elkilany, A.; Hamm, B.; Gebauer, B.; Geisel, D. Impact of interventionalist’s experience and gender on radiation dose and procedural time in CT-guided interventions—A retrospective analysis of 4380 cases over 10 years. Eur. Radiol. 2021, 31, 569–579. [Google Scholar] [CrossRef]
- Damm, R.; Damm, R.; Heinze, C.; Surov, A.; Omari, J.; Pech, M.; Powerski, M. Radioablation of Upper Abdominal Malignancies by CT-Guided, Interstitial HDR Brachytherapy: A Multivariate Analysis of Catheter Placement Assisted by Ultrasound Imaging. Roefo 2022, 194, 62–69. [Google Scholar] [CrossRef]
Protocol Name | Segments with X-ray Current Off 1 |
---|---|
10 o’clock | 300° (250–350°) |
12 o’clock | 0° (310–50°) |
2 o’clock | 60° (10–110°) |
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content. |
© 2024 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
Share and Cite
Grosser, O.S.; Volk, M.; Georgiades, M.; Punzet, D.; Alsawalhi, B.; Kupitz, D.; Omari, J.; Wissel, H.; Kreissl, M.C.; Rose, G.; et al. Effect of Spectral Filtering and Segmental X-ray Tube Current Switch-Off on Interventionalist’s Scatter Exposure during CT Fluoroscopy. Bioengineering 2024, 11, 838. https://doi.org/10.3390/bioengineering11080838
Grosser OS, Volk M, Georgiades M, Punzet D, Alsawalhi B, Kupitz D, Omari J, Wissel H, Kreissl MC, Rose G, et al. Effect of Spectral Filtering and Segmental X-ray Tube Current Switch-Off on Interventionalist’s Scatter Exposure during CT Fluoroscopy. Bioengineering. 2024; 11(8):838. https://doi.org/10.3390/bioengineering11080838
Chicago/Turabian StyleGrosser, Oliver S., Martin Volk, Marilena Georgiades, Daniel Punzet, Bahaa Alsawalhi, Dennis Kupitz, Jazan Omari, Heiko Wissel, Michael C. Kreissl, Georg Rose, and et al. 2024. "Effect of Spectral Filtering and Segmental X-ray Tube Current Switch-Off on Interventionalist’s Scatter Exposure during CT Fluoroscopy" Bioengineering 11, no. 8: 838. https://doi.org/10.3390/bioengineering11080838
APA StyleGrosser, O. S., Volk, M., Georgiades, M., Punzet, D., Alsawalhi, B., Kupitz, D., Omari, J., Wissel, H., Kreissl, M. C., Rose, G., & Pech, M. (2024). Effect of Spectral Filtering and Segmental X-ray Tube Current Switch-Off on Interventionalist’s Scatter Exposure during CT Fluoroscopy. Bioengineering, 11(8), 838. https://doi.org/10.3390/bioengineering11080838