Numerical Study of the Effect of the Port Angle of the Superior Vena Cava Supplying Cannula on Hemodynamics in the Right Atrium in VV-ECMO
Abstract
:1. Introduction
2. Method
2.1. 3D Geometry Model Reconstruction
2.2. Meshing Generation
2.3. Boundary Conditions
2.4. Calculation Settings
2.5. Hemodynamic Analysis
3. Results
3.1. Right Atrial Blood Flow Field
3.2. Right Atrial Wall Pressure
3.3. Right Atrial Wall WSS
3.4. Recirculation Fraction
3.5. Relative Residence Time
4. Discussion
5. Conclusions
Author Contributions
Funding
Institutional Review Board Statement
Informed Consent Statement
Data Availability Statement
Conflicts of Interest
References
- Di Russo, G.B.; Martin, G.R. Extracorporeal membrane oxygenation for cardiac disease: No longer a mistaken diagnosis. In Seminars in Thoracic and Cardiovascular Surgery: Pediatric Cardiac Surgery Annual; WB Saunders: Philadelphia, PA, USA, 2005; pp. 34–40. [Google Scholar]
- Fan, E.; Gattinoni, L.; Combes, A.; Schmidt, M.; Peek, G.; Brodie, D.; Muller, T.; Morelli, A.; Ranieri, V.M.; Pesenti, A.; et al. Venovenous extracorporeal membrane oxygenation for acute respiratory failure: A clinical review from an international group of experts. Intensive Care Med. 2016, 42, 712–724. [Google Scholar] [CrossRef] [PubMed]
- Maslach-Hubbard, A.; Bratton, S.L. Extracorporeal membrane oxygenation for pediatric respiratory failure: History, development and current status. World J. Crit. Care Med. 2013, 2, 29. [Google Scholar] [CrossRef]
- Liu, Y.; Liu, Y.; Tong, C.; Zhang, Y.; Liu, X.; Cong, P.; Jin, H.; Gao, Y.; Hou, M. Research progress of extracorporeal membrane oxygenation technology in clin-ical application. Trauma Crit. Care Med. 2016, 24–27. [Google Scholar] [CrossRef]
- Muhammad, J.; Rezaeimoghaddam, M.; Cakmak, B.; Rasooli, R.; Salihoglu, E.; Yıldız, Y.; Pekkan, K. Patient-Specific Atrial Hemodynamics of a Double Lumen Neonatal Cannula in Correct Caval Position. J. Artif. Organs 2018, 42, 401–409. [Google Scholar] [CrossRef] [PubMed]
- Togo, K.; Takewa, Y.; Katagiri, N.; Fujii, Y.; Kishimoto, S.; Date, K.; Miyamoto, Y.; Tatsumi, E. Impact of Bypass Flow Rate and Catheter Position in Veno-venous Extracorporeal Membrane Oxygenation on Gas Exchange In Vivo. J. Artif. Organs 2015, 18, 128–135. [Google Scholar] [CrossRef] [PubMed]
- Palmér, O.; Palmér, K.; Hultman, J.; Broman, M. Cannula Design and Recirculation during Venovenous Extracorporeal Membrane Oxygenation. ASAIO J. 2016, 62, 737–742. [Google Scholar] [CrossRef]
- Bonacchi, M.; Harmelin, G.; Peris, A.; Sani, G. A Novel Strategy to Improve Systemic Oxygenation in Venovenous Extracorporeal Membrane Oxygenation: The “Χ-Configuration”. J. Thorac. Cardiovasc. Surg. 2011, 142, 1197–1204. [Google Scholar] [CrossRef] [PubMed]
- Xie, A.; Yan, T.D.; Forrest, P. Recirculation in Venovenous Extracorporeal Membrane Oxygenation. J. Crit. Care 2016, 36, 107–110. [Google Scholar] [CrossRef]
- Xie, A.; Jayewardene, I.; Dinale, A.; Macdonald, P.; Pye, R.; Dhital, K. Recirculation during venovenous extracorporeal membrane oxygenation: A comparative mock circulation study. J. Heart Lung Transplant. 2015, 34, S193. [Google Scholar] [CrossRef]
- Conrad, S.A.; Wang, D. Evaluation of Recirculation During Venovenous Extracorporeal Membrane Oxygenations Using Computational Fluid Dynamics Incorporating Fluid-Structure Interaction. ASAIO J. 2021, 67, 943–953. [Google Scholar] [CrossRef] [PubMed]
- Madhani, S.P.; May, A.G.; Frankowski, B.J.; Burgreen, G.W.; Federspiel, W.J. Blood Recirculation Enhances Oxygenation Efficiency of Artificial Lungs. ASAIO J. 2020, 66, 565–570. [Google Scholar] [CrossRef] [PubMed]
- Ward, S.R.; Lieber, R.L. Density and hydration of fresh and fixed human skeletal muscle. J. Biomech. 2005, 38, 2317–2320. [Google Scholar] [CrossRef] [PubMed]
- Calvo, B.; Ramírez, A.; Alonso, A.; Grasa, J.; Soteras, F.; Osta, R.; Muñoz, M.J. Passive nonlinear elastic behaviour of skeletal muscle: Experimental results and model formulation. J. Biomech. 2010, 43, 318–325. [Google Scholar] [CrossRef]
- Kim, H.; Yoo, L.; Shin, A.; Demer, J.L. Determination of poisson ratio of bovine extraocular muscle by computed X-ray tomography. BioMed Res. Int. 2013, 2013, 197479. [Google Scholar] [CrossRef] [PubMed]
- Wang, H.; Anzai, H.; Liu, Y.; Qiao, A.; Xie, J.; Ohta, M. Hemodynamic-based evaluation on thrombosis risk of fusiform coronary artery aneurysms using computational fluid dynamic simulation method. Complexity 2020, 2020, 8507273. [Google Scholar] [CrossRef]
- Abrams, D.; Bacchetta, M.; Brodie, D. Recirculation in venovenous extracorporeal membrane oxygenation. ASAIO J. 2015, 61, 115–121. [Google Scholar] [CrossRef] [PubMed]
- Lebenatus, A.; Salehi Ravesh, M. Aortocaval fistula at 4D flow MRI: Visualization and quantification of vascular flow. Radiology 2018, 289, 617. [Google Scholar] [CrossRef] [PubMed]
- Meng, H.; Wang, Z.; Hoi, Y.; Gao, L.; Metaxa, E.; Swartz, D.D.; Kolega, J. Complex hemodynamics at the apex of an arterial bifurcation induces vascular remodeling resembling cerebral aneurysm initiation. Stroke 2007, 38, 1924–1931. [Google Scholar] [CrossRef] [PubMed]
- Han, Y.; Xia, J.; Jin, L.; Qiao, A.; Su, T.; Li, Z.; Xiong, J.; Wang, H.; Zhang, Z. Computational fluid dynamics study of the effect of transverse sinus stenosis on the blood flow pattern in the ipsilateral superior curve of the sigmoid sinus. Eur. Radiol. 2021, 31, 6286–6294. [Google Scholar] [CrossRef] [PubMed]
- Teijeiro-Paradis, R.; Gannon, W.D.; Fan, E. Complications Associated with Venovenous Extracorporeal Membrane Oxygenation—What Can Go Wrong? Crit. Care Med. 2022, 50, 1809–1818. [Google Scholar] [CrossRef]
T1 | T2 | T3 | T4 | |
---|---|---|---|---|
0.22 million | 2270.8 | 5176.3 | 2341.4 | 879.3 |
relative error | 1.94% | 4.66% | 6.83% | 9.86% |
0.43 million | 2315.8 | 5429.2 | 2513.1 | 975.43 |
relative error | 1.06% | 1.85% | 1.11% | 0.53% |
0.76 million | 2410.7 | 5681.6 | 2611.3 | 1018.6 |
CASE a −90° | CASE b −60° | CASE c −30° | CASE d 0° | CASE e 30° | CASE f 60° | CASE g 90° | |
---|---|---|---|---|---|---|---|
Maximum Pressure (Pa) | 13,472 | 13,424 | 10,915 | 7680.2 | 5890.3 | 5597.6 | 7883.5 |
Average Pressure (Pa) | 6788.9 | 8615.1 | 8684.9 | 6717.2 | 5429.2 | 5455.6 | 7117.8 |
Maximum WSS (Pa) | 63.572 | 55.839 | 31.705 | 39.531 | 40.11 | 28.474 | 35.424 |
Average WSS (Pa) | 3.8589 | 3.6706 | 3.3013 | 3.2487 | 2.3995 | 1.3304 | 2.0747 |
Proportion of High RRT Area | 3.44% | 2.23% | 4.24% | 1.83% | 3.69% | 7.73% | 3.68% |
CASE a −90° | CASE b −60° | CASE c −30° | CASE d 0° | CASE e 30° | CASE f 60° | CASE g 90° | |
---|---|---|---|---|---|---|---|
The number of particles frozen at the TV | 3142 | 3101 | 3018 | 3699 | 3803 | 4234 | 4057 |
The number of particles frozen at the IVCD | 864 | 939 | 744 | 532 | 434 | 226 | 355 |
Recirculation fraction (%) | 21.57% | 23.24% | 19.78% | 12.57% | 10.24% | 5.07% | 8.05% |
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content. |
© 2024 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
Share and Cite
Ma, X.; Xu, K.; Gao, B. Numerical Study of the Effect of the Port Angle of the Superior Vena Cava Supplying Cannula on Hemodynamics in the Right Atrium in VV-ECMO. Biomedicines 2024, 12, 2198. https://doi.org/10.3390/biomedicines12102198
Ma X, Xu K, Gao B. Numerical Study of the Effect of the Port Angle of the Superior Vena Cava Supplying Cannula on Hemodynamics in the Right Atrium in VV-ECMO. Biomedicines. 2024; 12(10):2198. https://doi.org/10.3390/biomedicines12102198
Chicago/Turabian StyleMa, Xinrui, Kaihang Xu, and Bin Gao. 2024. "Numerical Study of the Effect of the Port Angle of the Superior Vena Cava Supplying Cannula on Hemodynamics in the Right Atrium in VV-ECMO" Biomedicines 12, no. 10: 2198. https://doi.org/10.3390/biomedicines12102198
APA StyleMa, X., Xu, K., & Gao, B. (2024). Numerical Study of the Effect of the Port Angle of the Superior Vena Cava Supplying Cannula on Hemodynamics in the Right Atrium in VV-ECMO. Biomedicines, 12(10), 2198. https://doi.org/10.3390/biomedicines12102198