Skip to Content
You are currently on the new version of our website. Access the old version .
BiosensorsBiosensors
  • Review
  • Open Access

30 June 2025

31 Pages

Biosensing Strategies to Monitor Contaminants and Additives on Fish, Meat, Poultry, and Related Products

,
,
,
and
1
Department of Food Science and Post-Harvest Technology, College of Dryland Agriculture and Natural Resources, Mekelle University, Mekelle P.O. Box 231, Ethiopia
2
Department of Chemical Engineering, Payame Noor University, Tehran 19395-4697, Iran
3
Laboratory of Preclinical and Translational Research, IRCCS CROB, Centro di Riferimento Oncologico della Basilicata, 85028 Rionero in Vulture, Italy
4
Laboratory of Microbial and Enzymes Biotechnology and Biomolecules (LMEBB), Centre of Biotechnology of Sfax (CBS), University of Sfax-Tunisia, Road of Sidi Mansour Km 6, P.O. Box 1177, Sfax 3018, Tunisia

Abstract

Biosensors have emerged as highly sensitive, rapid, and specific tools for detecting food safety hazards, particularly in perishable products, such as fish, meat, and poultry. These products are susceptible to microbial contamination and often contain additives intended to improve shelf life and flavor, which may pose health risks to consumers. Recent advances in biosensor technologies integrated with smartphones, artificial sensing systems, 3D printing, and the Internet of Things (IoT) offer promising solutions for real-time monitoring. This review explores the types, mechanisms, standardization approaches, and validation processes of biosensors used to detect contaminants and additives in animal-based food products. Furthermore, the paper highlights current challenges, technical limitations, and future perspectives regarding the broader implementation of biosensors in modern food safety monitoring systems.

1. Introduction

A wide range of contaminants, including physical, allergenic, environmental, chemical, and biological agents, can be found in fish, meat, poultry, and related products. According to the World Health Organization (WHO), approximately 600 million people fall ill and 420,000 die each year due to foodborne diseases [1]. The consumption of fish, meat, poultry, and related products with compromised quality and safety can significantly increase the risk of foodborne illnesses. Numerous chemical and biological contaminants have been reported in such products, including antibiotic residues, toxic chemicals, food additives, heavy metals, pathogens, and pesticides. For instance, nitrate has been detected in meat samples [2]; chloramphenicol, an antibiotic residue, has been found in beef and pork samples [3]; and pathogens, such as Salmonella enterica, Listeria monocytogenes, and Escherichia coli, have been identified in ready-to-eat beef, chicken, and turkey breast meat [4]. Other reported issues include the adulteration of donkey meat in cooked sausages [5], and the presence of spoilage biogenic amines, such as hypoxanthine (Hx), in fish samples [6]. Rapid and accurate detection of food contaminants, as an alternative to traditional culture-based techniques, is gaining increasing emphasis on current food quality and safety management systems. Conventional methods for detecting food contaminants, such as culture-based techniques, antibody-based immunoassays, fatty acid and protein profiling, chromatographic separations, and spectroscopic analyses, face several limitations. These include labor-intensiveness, high costs associated with chemical reagents, time-consuming procedures, the need for trained personnel, and limited applicability for on-site detection due to their dependence on laboratory infrastructure [1]. Figure 1 illustrates the target analytes in meat and fish samples, along with the types of bioreceptors and the corresponding measurement techniques. Biosensors are analytic devices employed to analyze, record, and transform biochemical information by controlling the interaction of immobilized bioreceptors and chemical components from pathogenic or naturally produced or additives used in foods [7,8]. Applications of food biosensors in intelligent packaging—such as for labeling, microbial spoilage detection, time–temperature indicators, nanosensors, and barcodes—are becoming increasingly common at industrial and commercial levels [9]. Biosensors are classified based on their measurement principles and the types of transducers used for real-time monitoring. These include: physical biosensors (which detect changes in mass, pressure, strain, or force), electrical biosensors (which measure variations in electrical distribution), calorimetric biosensors (which monitor changes in heat), optical biosensors (which detect changes in light), magnetic biosensors (which respond to changes in magnetic fields), and ion channel switch biosensors (which detect functional molecular interactions) [1]. Another classification of biosensors is based on the type of biorecognition element used to detect target analytes in the quality and safety monitoring of fish, meat, and poultry-related products. Enzyme-based biosensors, immunosensors, and DNA-based biosensors are among the most common types in this category, as described by Nami et al. [7]. Biosensors can also be classified based on their readout mechanisms, which include acoustic wave sensors, surface plasmon resonance (SPR), and mass spectrometry, as well as label-based approaches, such as fluorescence and chemiluminescence, as designated by Nanda et al. [9].
Figure 1. Schematic representation of meat and fish sample, target analytes, biorecognition elements, and an analytical method.
Standardization and validation of biosensors in fish, meat, poultry, and related product quality and safety monitoring for better reliability, reproducibility, and regulatory acceptance are mandatory at commercial and industrial levels. The complexity of food matrices and interference of environmental and biochemical changes could reduce the reliability and reproducibility of biosensors. Hence, calibration and standardization are regular approaches that should be established. For instance, heat-transfer biosensors employed to detect trace levels of chemical additives in dairy were calibrated to consistent sensitivity and reproducibility [10]. Although various types of biosensors have been developed to monitor fish and meat samples, their integration into regulatory and commercial systems, like HACCP, ISO 22000:2018 [11], and Codex Alimentarius, has not yet been fully realized due to limitations in standardization and validation. This review is intended to share insights on the biosensing strategies of biosensors for monitoring contaminants and additives in fish, meat, poultry, and related products. Moreover, a brief discussion on standardization and validation of biosensors in real-time quality analysis as well as current challenges, technical limitations, and future perspectives of biosensor utilization have been addressed.

3. Applications of Biosensors in Real-Time Food Quality Monitoring in Fish, Meat, and Meat Products

3.1. Biosensor-Based Detection of Freshness Indicators in Fish, Meat, and Meat Products

To measure the qualitative and quantitative characteristics of meat and meat product freshness, the visual appearance, pH, and meaty aroma are the major ones. In this line, metabolites, synthesized by chemical oxidation and microbial proliferation, could modify the quality of muscle food freshness. During storage, metabolites generated by microbial growth and chemical oxidation alter the quality and freshness of muscle foods [25,26,27,28]. Figure 4 shows existing applications of biosensors to monitor the freshness and quality of fish, meat, and meat products.
Figure 4. Applications of biosensors in meat and fish samples.

3.1.1. Hypoxanthine

In the fish/meat industry, xanthine is exploited as a freshness indicator because of its accumulation in tissues after death. In order to monitor the freshness of pork, a TiO2 and graphene composite has been established [6]. The biosensor assesses the oxidation activity of XOD and Hx for seven days under refrigerated conditions [6]. Hx existence provokes a sour taste that is facile for detecting fish and meat sample degradation. Pierini et al. [29] developed an electroanalytical tool (edge plane pyrolytic graphite electrode) to determine the Hx, xanthine, and UA content in Argentinian fish samples. Similarly, to control the Hx content for pork meat freshness at several post-mortem periods, Guo et al. [30] developed an enzyme sensor by joining the O2 electrode and XOD. These authors reported that the produced biosensor displayed heightened sensitivity to Hx compared to HPLC analysis. By grafting reduced expanded graphene oxide (REGO) with Fe3O4 nanoparticles, Dervisevic et al. [31] produced a new amperometric xanthine biosensor and applied it to control fish freshness for 20 days. The xanthine concentration was detected at a range between 2 and 36 mM, at 3 s at detection limit equal to 0.17 mA/M. Interestingly, in 25-day-old fish samples, biosensors monitored 70% of its activity. In order to assess fish freshness with color marking by the unaided eye, XOD was employed in enzyme-mediated AuNR oxidation [32]. In this study, the color of the sensing system has a good link with the Hx level at a range between 0.05 and 0.63 mM. Chen et al. [33] proposed a fluorescence sensor derived from platinum nanoparticles (Pt NPs) to perceive Hx in aquatic products. At a [Hx] range between 8 and 2500 μM, the new biomaterial possesses a linear connection and detection limit of 2.88 μM. In meat samples, a μPAD biosensor was developed to detect Hx. The detection and quantitative limits were registered at 1.8 and 6.1 mg/L, respectively. The proposed assay exhibited a linear dynamic in the range of 5–40 mg/L. The analysis time was 5 min for triplicate measurement [34]. To assess meat freshness by Hx detection, Görgülü et al. [35] fabricated multi-enzyme biosensors. In this study, polypyrrole–polyvinyl sulphonate (PPy–PTS) films were synthesized on the platinum electrode surface by electropolymerization. The indicator enzymes, XOD and uricase, were immobilized within the polymer matrix. The registered amperometric response, at a potential of +400 mV, was attributed to the current resulting from the enzymatic oxidation of H2O2. The established biosensor displayed a minimum detection limit of 2.5 µM and a concentration range with a linear response of 2.5 to 10 µM. After 33 days of storage, the biosensor maintained 65% of its initial performance, demonstrating acceptable long-term stability for practical applications. This indicates the reusability and long-term stability of the developed enzyme electrode, considering storage conditions. For the evaluation of Hx in beef, chicken, fish, and pork meat, Devi et al. [36] evolved a biosensor designed with Au/Fe nanoparticles, and XOD was covalently grafted onto the electrode surface. At an optimal response within 3 s at pH 7.2 and 30 °C, the biosensor showed linearity in the range of 0.05 µM to 150 µM for Hx, with a detection limit of 0.05 µM. Using an absorption transmission approach, Garg and Verma [21] developed an optical biosensor for the detection of Hx. The assay is based on an enzymatic reaction catalyzed by XO, which converts xanthine into uric acid and H2O2. The formation of uric acid leads to a pH decrease, typically from 7.5 to 6.0. The researchers evaluated the xanthine content in chicken meat over a five-day storage period. As expected, xanthine levels increased progressively, indicating meat quality deterioration—from approximately 5 µM on day 1 to 44 µM on day 5. The method’s reliability was established in spiked samples, displaying a recovery between 94.2 and 96.5%. Zhang et al. [37] developed a new tool named electrochemiluminescence (ECL) of CdS quantum dots (QDs), combining electrochemistry and chemiluminescence. This technique indicated that electrical energy was used to launch a chemical reaction that generates light. These authors assembled and synthesized the new material onto poly (diallyldimethylammonium chloride)-functionalized carbon nanospheres (PFCNSs), leading to an increase in ECL intensity by dissolved O2 as a co-reactant. The sensor established a fast response with a linear range from 2.5 × 10−8 to 1.4 × 10−5 M and a detection limit of 5 nM (S/N = 3), and the obtained findings from fish sample analysis were closely matched to those from standard amperometric methods. The response time is the time it takes for a biosensor to respond to a change in the analyte concentration. The difference in sensing/analyzing time of the biosensors in the above discussion could be due to the type of biosensor, the analyte, and the transducer technology, which can influence the response time.

3.1.2. Biogenic Amines and Volatile Amines

Biogenic amines, small organic compounds comprising one or more amino groups, are categorized into aliphatic, aromatic, and heterocyclic amines. These amines are mainly synthesized by the enzymatic decarboxylation of free amino acids or by amination and transamination of aldehydes and ketones [38].
The most prevalent biogenic amines present in aquatic and meat products are tyramine, cadaverine, putrescine, histamine, and trimethylamine [39]. Throughout muscle food deterioration, the formation of histamine, putrescine, and cadaverine are generally used as freshness indicators and can be monitored. Zhai et al. [40] created an amine-responsive bilayer film by using agar (AG), anthocyanins (AN), gellan gum (GG), and TiO2 nanoparticles for visual monitoring of meat spoilage. The AG-AN layer served as the detecting layer for volatile amines, while the AG-AN/GG-2%TiO2 film noticed trimethylamine (TMA) at a limit of 0.018 mM, a typical gas from meat spoilage. During the spoilage of silver carp and pork, the film exhibited a color variation ranging from rose-red to green, emphasizing its potential use in intelligent food packaging.
Based on the peroxidase-like activity of (Fe and Co) co-doped-CDs, Li et al. [41] developed a colorimetric tool to detect cadaverine and putrescine. With the enzymatic hydrolysis by diamine oxidase, biogenic amines were disintegrated to generate H2O2, which reacts with tetramethyl-benzidine with the catalysis of (Fe,Co)-co-doped CDs. The colorimetric method was used to perceive cadaverine and putrescine in various fish samples with a limit of 0.06 mg/kg. Checked by HPLC, the recoveries of the colorimetric method were confirmed by standards, signifying that the established colorimetric method was sensitive and accurate.
In order to monitor biogenic amines (BAs), Luo et al. [42] developed a hydrogel composed of β-d-glucose pentaacetate (β-D-GP), silver ions, and agarose. Under alkaline conditions, in contact with BAs, β-D-GP could be hydrolyzed to form β-d-glucose, which decreases silver ions to silver nanoparticles, and generates visible color variations. These changes can be analyzed with the naked eye or quantified using smartphone-based RGB (red/green/blue) analysis of fish samples. Polyaniline (PANI) synthesized via in situ chemical oxidative polymerization was spray-coated onto flexible interdigitated electrodes (IDEs) for observing ammonia gas and have been employed for checking food quality. The sensor’s electrical response increased linearly with increasing ammonia concentrations. It confirmed a constant linear response in the 50–150 ppm range and effectively evaluated the meat and sheep liver freshness in real-time [43]. Chang et al. [44] produced a detection system with an ultrasensitive amine gas sensor to perceive volatile amines in raw fish. Remarkably, the sensor offers an electrical response within 1 min that meticulously links total volatile basic nitrogen (TVBN) values. The sensor’s ppb-level sensitivity and integrated humidity control enable fast and accurate detection. These findings support the development of real-time, on-site freshness monitoring in fish processing environments. The amine gas sensor can detect ammonia, dimethylamine (DMA), and trimethylamine (TMA) at ppb levels, enabling it to monitor volatile compounds released from raw fish and indicate spoilage. The method truthfully releases the effects of storage temperature and a fish portion viz. ventral, dorsal, and lateral on spoilage development. For beltfish and mackerel, the sensors displayed a robust correlation with TVBN values.
Through in situ polymerization, Shi et al. [45] deposited TiO2-PANI into Silk Fibroin Fiber (SFF). The novel composite (TiO2-PANI/SFF) played the role of an excellent micro sensor exhibiting a sensing capability, with a response value equal to 0.82 and a response time of 10 s to 100 μg/L of NH3. In pork samples, the sensors used to evaluate freshness showed a strong correlation with TVB-N levels (R2 = 0.99). To measure TVBN more effectively, two non-destructive sensing methods, colorimetric sensors and hyperspectral imaging (HSI), were combined [46]. For data fusion and modeling, these authors proposed a BP-AdaBoost that corresponds to an effective backpropagation adaptive boosting algorithm. The performance of the model was examined relative to a PCA-BPANN: backpropagation artificial neural network model. The test results revealed that the data fusion model outdid the single-sensor models, with BP-AdaBoost proposing superior capability in handling complex data fusion compared to PCA-BPANN. In pork meat, this investigation revealed the possible integration of HIS and colorimetric sensors and the BP-AdaBoost algorithm for non-destructive TVB-N.

3.2. Biosensor-Based Detection of Microbial Hazards in Fish, Meat, and Meat Products

The occurrence of pathogenic microorganisms in food cause significant dangers to general health safety and can also affect the environment. Biosensor expansion has importantly improved food safety [47]. Conventional microbiological methods characteristically comprise enrichment, filtration, and incubation phases, requiring a time frame of 2–10 days to obtain [48]. Contrarily, modern biosensor-based tools proposed earlier have more precise detection, with the further advantage of on-site pertinence. For pathogens and their toxins and metabolites, their low detection limits the importance of highly sensitive analytical tools for guaranteeing fish, meat, and meat product safety.
Among different optical sensing methods, colorimetric, fluorescence, chemiluminescence SPR, and localized surface plasmon resonance (LSPR) are usually employed [49]. SPR-based biosensing normally engages reflectance spectroscopy for the detection of target pathogens, and the bioreceptors are fixed to a metal transducer surface. Specific wavelengths of electromagnetic radiation act towards the metal’s electrons and generate resonance. When bacterial cells attach to this surface, they induce quantifiable variations in the refractive index [47]. To detect pathogenic microorganisms in different meat and meat products, optical biosensors were employed. As an illustration, a fiber-optic immunosensor, fortified with immunomagnetic separation, certainly perceived Listeria monocytogenes in meat at levels as <3 × 102 CFU/mL [50]. Another method employed an aptamer-based fiber-optic biosensor to select L. monocytogenes in artificially infected ready-to-eat (RTE) meat, effectively identifying it specifically among other microbial strains [51]. Oh et al. [52] engaged LSPR to detect Salmonella Typhimurium in pork at 4 log CFU/mL within 30 min. To synchronize the detection of E. coli O157:H7, Salmonella enteritidis, and Listeria monocytogenes, Zhang et al. [53] established an SPR biosensor combined with an enrichment broth. To simplify selective recognition, polyclonal antibodies that are special for each pathogen were anchored on separate channels of SPR chips. After an enrichment step, chicken meat was analyzed using the SPR system, efficaciously perceiving target microorganisms at 14, 6, and 28 CFU/25 g for E. coli O157:H7, Salmonella enteritidis, and Listeria monocytogenes, respectively. Liang et al. [54] produced a smartphone-based biosensor to detect microbial spoilage of ground beef. In this study, the lower limit of detection was between 10 and 100 CFU of Escherichia coli K12. Morant-Miñana and Elizalde [55] produced an electrochemical genosensor for Campylobacter spp. detection. This new material, developed from thin-film gold electrodes dropped onto Cyclo Olefin Polymer (COP), displayed high sensitivity, a robust linear response for Campylobacter spp., and positive authentication of real poultry meat samples. It displayed similar findings to those obtained with purified PCR products with a concentration range between 1 and 25 nM, and a LOD equal to 90 pM. Ohk and Bhunia [4] developed and optimized a multiplex fiber optic sensor able to simultaneously detect L. monocytogenes, E. coli O157:H7, and S. enterica in food samples. Streptavidin-coated optical sensors were equipped with biotinylated polyclonal antibodies and treated with bacterial suspensions or supplemented food samples for 2 h. In this study, turkey, ready-to-eat beef, and chicken samples were inoculated with ~102 CFU of each pathogen/25 g and enriched for 18 h in a selective enrichment medium SEL broth and tested by the biosensor. The sensor positively recognized each pathogen individually or in combination, and the detection limit was 103 CFU/mL for all three pathogens. This new approach, a multiplex fiber optic biosensor, could be appropriate for simultaneously detecting Listeria, E. coli, and Salmonella in food, decreasing the necessity for separate single-pathogen detection systems. By virtue of its excellent characteristics, like ultra-rapid electron transfer aptitude, great surface/volume ratio, suitability for biological applications, and its single connections with DNA bases of the aptamer, Muniandy et al. [56] fabricated an rGO-azophloxine nanocomposite (rGO-AP) aptasensor to detect foodborne pathogens. The contact of the label-free single-stranded deoxyribonucleic acid (ssDNA) aptamer with S. Typhimurium was examined by variance pulse voltammetry exploration, and this aptasensor indicated high selectivity and sensitivity for the detection of intact bacterial cells. rGO-AP revealed a linear detection range between 10 and 108 CFU/mL and a good linearity (R2 = 98%). Furthermore, rGO-AP could detect bacterial concentrations ranging from 10 to 104 CFU/g in chicken samples inoculated with S. Typhimurium. Rasooly [57] evaluated the potential of SPR biosensors to detect staphylococcal enterotoxin B (SEB), engaging 2 antibodies, in foods. A capturing antibody, covalently enclosed in the biosensor chip surface, performed the initial binding of the antigen, and a second antibody sticks to the captured antigen. Initially, the entire assessment cycle took 5 min when using a single antibody and 8 min when two antibodies were employed. Interestingly, the SPR biosensor could detect SEB in meat at 10 ng/mL, with initial binding at < 2 min. In another study conducted by Liu et al. [58], a fast detection of Salmonella serotypes B and D in ready-to-eat (RTE) turkey has been explored. These authors proved that the concentration of Salmonella <3 × 102 cells/mL at 1 h was attained. Additionally, the findings displayed that the sensor can distinguish low concentrations of live Salmonella cells from high levels of dead Salmonella cells.

3.3. Biosensor-Based Detection of Contaminants, Antibiotics, and Drug Residues in Fish, Meat, and Meat Products

Food quality valuation includes perceiving impurities, such as drug residues, pesticides, toxins and heavy metals. Conventional tools, like mass spectrometry and capillary electrophoresis, are costly and require considerable time. To guarantee consumer security, biosensors offer a closer and gainful alternative with adequate perception. For instance, for heavy metals, such as Cd, As, and Hg, biosensors employed enzymes (e.g., GOx, urease, cholinesterase, alkaline phosphatase) and genetically modified microorganisms [59]. By developing a chemiluminescence sensor called MIP (molecularly imprinted polymer (MIP), Cai et al. [60] recognized eight benzimidazoles in beef and mutton, establishing ultrafast sensitivity. In fact, these authors confirmed that the detection limits ranged between 1.5 and 21 pg/mL, with 18 min, and had a high recovery efficiency (66–91%). To identify fungal or bacterial toxins existing in meat products, electrochemical biosensors are used. As an example, trichothecene (T-2 toxin) was detected in swine meat [61]. By employing an electrochemical and SPR biosensors, Staphylococcal enterotoxin B was sensed in pork [62] and potted meat [57], respectively. Using an amperometric biosensor, Dinçkaya et al. [2] appraised the nitrate concentrations in meat and confirmed that the LOD was 2.2 × 10−9 M with a response time equal to 10 s. On the other hand, some studies employed SPR as biosensors to identify drug residues. In several meat species like pork, beef, and chicken, SPR technique was able to detect sulphonamides and chloramphenicol have been quantified [62,63,64,65]. In order to detect the SDM: sulfadimethoxine in beef and chicken meat, Mohammad-Razdari et al. [66] established an electrochemical biosensor based on a pencil graphite electrode (PGE) and adapted with a reduced graphene oxide (RGO) and Au nanoparticles for sulfadimethoxine (SDM). In the best-performing trials, the proposed biosensor showed a linear range from 10 to 10−5 M and a LOD at 3.7 × 10−16 M towards SDM. For meat sample applications, the aptasensor was applied to fish, chicken, and beef and showed acceptable recovery rates across the tested concentration range, demonstrating dependable performance and accuracy in analytic quantification between 92 and 103%. For the label-free detection of ceftiofur residues in meat trials, Stevenson et al. [67] developed an affinity-based electrochemical biosensor. These authors validated a platform that could detect ceftiofur within 15 min of using the sample at levels down to 0.01 ng/mL in phosphate-buffered saline and 10 ng/mL in 220 mg ground turkey meat samples. Table 2 summarizes some examples of biosensors for monitoring the quality and safety of fish, meat, and meat products.
Table 2. Biosensors for monitoring the quality and safety of fish, meat, and meat products.

4. Standardization and Validation of Biosensors in Real-Time Food Quality Monitoring

The standardization and validation of biosensors are indispensable processes for ensuring their reliability, reproducibility, and regulatory acceptance in the food industry. Unlike conventional chemical assays, biosensors often demonstrate significant variability due to differences in biological recognition elements, sensor fabrication, and susceptibility to environmental factors, such as temperature, pH, and matrix complexity. This variability makes robust calibration and method validation protocols necessary for ensuring consistent performance across food matrices and operational environments [81,82].
Calibration and standardization are foundational steps for establishing accuracy and consistency in biosensor output. The calibration process typically involves the use of matrix-matched reference standards, ideally certified, to reflect real-world food conditions in terms of composition, viscosity, and potential interferents [83]. Biosensors must exhibit predictable and linear responses across a defined concentration range of the target analyte. For example, a heat-transfer biosensor used for detecting trace levels of chemical additives in dairy was calibrated using milk samples with varying fat contents to ensure consistent sensitivity and reproducibility [10].

4.1. Validation

Although harmonized guidelines for validation of biosensor-based methods do not exist, a valid text is represented by the International Council for Harmonisation (ICH) “Bioanalytical Method Validation and Study Sample Analysis—M10 guideline, 2022” [84]. This document was adopted also by the European Medicines Agency (EMA) and the Food and Drug Administration (FDA). Method validation, as defined in the ICH M10 guideline, requires comprehensive evaluation of analytical performance. Key parameters include accuracy, precision (repeatability and intermediate precision), selectivity, sensitivity, linearity, LOD, limit of quantitation (LOQ), carryover, and analyte stability [85,86,87,88]. The main concepts in bioanalytical method validation and key biosensor validation parameters are illustrated in Figure 5.
Figure 5. Bioanalytical method validation. (a) Key biosensor validation parameters. (b) Various aspects of bioanalytical method validation (reproduced from Vazvaei-Smith et al. [88] with permission from the AAPS Journal, copyright 2024).

4.1.1. Specificity and Cross-Reactivity Challenges

In biosensor-based ligand binding assays (LBA), specificity refers to the sensor’s ability to detect only the target analyte without interference from structurally similar compounds, such as analogues, metabolites, or co-formulated substances. This becomes critical when detecting contaminants, like veterinary drug residues or pesticide metabolites. Specificity is typically evaluated by spiking blank matrix samples with structurally related compounds at their expected maximal concentrations. A well-validated biosensor should show negligible response to these analogues and maintain accuracy for the primary analyte within ±25% at the extremes of its dynamic range. In cases in which specificity is compromised, adjusting the quantification range or employing alternative recognition elements (e.g., more selective antibodies or aptamers) may be necessary.

4.1.2. Selectivity in Complex Food Matrices

Selectivity addresses the biosensor’s performance in distinguishing the analyte from endogenous matrix components that may interfere with detection. This is especially challenging in samples, such as milk, eggs, or processed foods, where proteins, fats, and enzymes can cause non-specific binding or signal suppression. To ensure selectivity, the assay must be tested in at least 10 different blank food matrix samples, with analytes spiked at both low and high concentrations. The signal from unspiked samples should fall below the lower LLOQ in at least 80% of the matrices tested. Selectivity testing should also consider lipemic and hemolyzed conditions, as well as matrices derived from diseased or stressed animal populations when relevant.

4.1.3. Calibration Curve and Reportable Range

Accurate quantification with biosensors depends on the establishment of a calibration curve, relating the analyte concentration to the signal response. The curve should span from the LLOQ to the upper limit of quantification (ULOQ), ideally covering at least six concentration points plus a blank. Many biosensor platforms use a logistic fit (4- or 5-parameter models) to accommodate non-linear signal responses, especially near saturation zones. A robust calibration curve requires consistency across multiple runs (minimum of six), with at least 75% of calibration points meeting accuracy criteria (±25% at LLOQ/ULOQ; ±20% at other levels).

4.1.4. Accuracy and Precision Requirements

Validation of accuracy (closeness to the true value) and precision (repeatability) is conducted using quality control (QC) samples at multiple concentration levels, typically LLOQ, low, medium, high, and ULOQ. Within-run and between-run performance should be assessed over at least six analytical runs using independently prepared QCs. Acceptable accuracy and precision limits are ±20% (±25% for LLOQ and ULOQ). A total error (sum of bias and variability) threshold of ≤30% (≤40% at extremes) is often applied as an overall acceptance criterion.

4.1.5. Dilution Linearity and High-Dose Hook Effect

Due to the limited dynamic range of many biosensors, the dilution of samples with high analyte concentrations is necessary. Dilution linearity must be verified to ensure that sample dilution does not introduce bias. This is also critical for identifying the hook effect, a phenomenon in which excessive analyte concentrations saturate binding sites, leading to signal suppression. Dilution series should be tested in at least three independent preparations, demonstrating linearity across the measured range, with ≤20% deviation from expected values.

4.1.6. Stability Under Analytical Conditions

Stability testing ensures that storage, processing, and handling conditions do not compromise the biosensor’s performance. This includes assessments of freeze–thaw stability, bench-top stability, and long-term storage. For each condition, QCs at low and high concentrations should be evaluated, and analyte recovery should remain within ±20% of nominal values. This step is particularly important for biosensors using biologically active components (e.g., enzymes or antibodies), which are prone to degradation under suboptimal storage.
These criteria ensure the biosensor ability to generate reliable results for target contaminants, such as pesticides, preservatives, or industrial pollutants [85]. These validation criteria should be tailored depending on whether the biosensor detects contaminants, chemical additives, toxins, or other analytes. A critical point is also food matrices; in fact, the ICH M10 Guideline underlines that other pivotal parameters are matrix effects, incurred sample reanalysis (ISR), and inter-batch reproducibility, all of which are particularly relevant for biosensors deployed in complex food matrices, like oils, processed meats, and lipid-rich seafood (e.g., shellfish) [89,90].
While the ICH M10 guideline does not explicitly refer to “measurement uncertainty” in metrological terms, it does encompass key contributors to uncertainty through required validation parameters, such as accuracy, precision, LOD, LOQ, and total error. These collectively influence the uncertainty of biosensor measurements. In the context of biosensors, where environmental and matrix effects can further amplify variability, it may be valuable for future regulatory guidance or standardization efforts to integrate formal uncertainty estimation.
In Table 3, a summary of these parameters as well as a brief description is reported.
Table 3. Summary of key validation parameters for biosensor-based methods according to ICH M10 guidelines.
Despite innovative sensor designs, regulatory approval remains a time-intensive process. In fact, often, apart from a validation study, a comparison study with validated chemical reference methods, such as HPLC or mass spectrometry, is preferred. These comparative assessments are crucial for establishing biosensor equivalence in terms of sensitivity, selectivity, and reproducibility. Without this level of validation, biosensors face challenges in gaining acceptance for routine food safety monitoring, despite offering advantages, such as portability and real-time readouts [91,92].
Biosensor integration into quality control systems presents operational challenges, including interoperability with digital traceability platforms, training personnel in sensor operation, and upgrading existing laboratories or processing infrastructure. In large-scale manufacturing environments, biosensor data must seamlessly interface with automated decision-support systems for tasks, such as batch release or contamination alerts [93,94,95].
Furthermore, data harmonization is critical. Standardized biosensor outputs must be structured and formatted for compatibility with central databases that consolidate information from inspections, internal audits, and supply chain feedback. As highlighted by Wijayanti et al. [96], biosensors are increasingly incorporated into the digitalization of food quality frameworks, but effective deployment requires unified validation standards and interoperable data formats to enable real-time risk assessment and traceability [97].

4.2. Limits and Challenges for Biosensor Application in Real-Time Food Quality Monitoring

Achieving high sensitivity and specificity remains a central challenge in the development of biosensors for detecting food additives and contaminants. These parameters determine the biosensor’s ability to detect target analytes at trace levels and to discriminate them from structurally similar compounds. In complex food matrices, such as milk or cereals, matrix components can interact with sensor surfaces or recognition elements, leading to background signal noise or false positives [97].
For instance, certain immunoassays for mycotoxins have demonstrated cross-reactivity with masked or metabolized toxin forms, undermining their selectivity. Similarly, surface-enhanced Raman scattering (SERS)-based lateral flow biosensors developed for detecting colistin in milk have shown matrix interference from milk proteins, which reduced analytical clarity despite fast detection times. Such cases highlight the need for advanced recognition elements and sample pre-treatment strategies to mitigate matrix effects and improve signal fidelity. Moreover, the operational stability of biosensors, especially those incorporating biological recognition elements, like enzymes or antibodies, is a persistent issue limiting their shelf-life. Enzyme-based biosensors are particularly susceptible to denaturation or leaching during storage, which reduces signal reproducibility and overall reliability [98,99].
Efforts to improve stability have focused on immobilization techniques, such as cross-linking, encapsulation in polymeric matrices, or covalent bonding to support materials. These approaches aim to preserve the functional conformation of the biomolecules and enhance resilience to environmental stressors during storage and use. However, long-term validation of such methods under varied food storage conditions remains limited and is critical for regulatory and industrial acceptance. Another critical issue may be represented by environmental factors, including temperature, humidity, and pH, which have a significant impact on biosensor performance. Temperature fluctuations can alter enzyme kinetics, signal generation rates, or the refractive index in optical systems. For example, enzymatic biosensors may show exaggerated signals at elevated temperatures or delayed responses in colder environments. Similarly, pH instability affects the electrochemical response of sensors, especially those incorporating carbon nanomaterials for detecting heavy metals or preservatives [100].
Humidity can degrade sensitive components, particularly in optical biosensors, in which uncontrolled moisture introduces signal noise or damages light-sensitive dyes. Moreover, food matrices with variable composition further complicate biosensor operation, reinforcing the need for robust calibration and compensation mechanisms to ensure consistent performance [101].
Some examples of issues in biosensor validation and application for the analysis of food additives and contaminants, along with the study strategies developed for their resolution, are proposed in Table 4.
Table 4. Biosensor applications for food additives and contaminants: key challenges and mitigation strategies.

6. Conclusions

Biosensors have emerged as transformative tools for ensuring the safety and quality of fish, meat, poultry, and related food products. Their capacity to rapidly and sensitively detect contaminants, pathogens, spoilage markers, and drug residues positions them as viable and often superior alternatives to conventional laboratory-based methods. Recent advancements including the integration of nanomaterials, lab-on-a-chip platforms, smartphone interfaces, and IoT connectivity have significantly enhanced their portability, usability, and real-time monitoring capabilities.
Nevertheless, several critical challenges remain. The complexity of food matrices, environmental variability (such as pH, humidity, and temperature), and the inherent instability of biological recognition elements can affect performance and limit reproducibility. Regulatory acceptance is further constrained by the absence of harmonized validation standards and insufficient comparative assessments with gold-standard analytical techniques. Additionally, high development and implementation costs hinder widespread adoption, particularly in resource-limited settings.
Looking forward, the development of biosensors should prioritize robustness, affordability, and compliance with international regulatory frameworks. Embracing the REASSURED criteria, ensuring that devices are real-time, easy to use, affordable, sensitive, specific, user-friendly, rapid, robust, equipment free, and deliverable to end users, will be key to broader deployment. Integration with AI-powered analytics and blockchain-based traceability systems can also unlock new opportunities for predictive diagnostics and transparent supply chain management. With continued interdisciplinary collaboration and innovation, biosensors are well-positioned to become cornerstone technologies in next-generation food safety and quality assurance systems.

Author Contributions

S.S.: writing—review and editing, writing—original draft, validation, resources, investigation, formal analysis, data curation, conceptualization. T.V.: writing—review and editing, writing—original draft, visualization, validation, supervision, project administration, methodology, investigation, formal analysis, data curation, conceptualization. E.H.: writing—original draft, writing—review and editing, validation, formal analysis, data curation, investigation, visualization. Z.T.T.: writing—review and editing, writing—original draft, visualization, validation, methodology, investigation, data curation. T.D.: writing—review and editing, writing—original draft, visualization, validation, methodology, investigation, data curation. All authors have read and agreed to the published version of the manuscript.

Funding

This research received no external funding.

Data Availability Statement

No new data were created or analyzed in this study. Data sharing is not applicable to this article.

Conflicts of Interest

The authors declare no conflicts of interest.

References

  1. Daramola, O.B.; Omole, R.K.; Akinsanola, B.A. Emerging applications of biorecognition elements-based optical biosensors for food safety monitoring. Discov. Sens. 2025, 1, 3. [Google Scholar] [CrossRef] [Scilit]
  2. D’Amore, T.; Di Taranto, A.; Berardi, G.; Vita, V.; Iammarino, M. Nitrate as Food Additives: Reactivity, Occurrence, and Regulation. In Nitrate Handbook; CRC Press: Boca Raton, FL, USA, 2022; ISBN 978-0-429-32680-6. [Google Scholar]
  3. Zhang, N.; Xiao, F.; Bai, J.; Lai, Y.; Hou, J.; Xian, Y.; Jin, L. Label-free immunoassay for chloramphenicol based on hollow gold nanospheres/chitosan composite. Talanta 2011, 87, 100–105. [Google Scholar] [CrossRef] [Scilit]
  4. Ohk, S.-H.; Bhunia, A.K. Multiplex fiber optic biosensor for detection of Listeria monocytogenes, Escherichia coli O157:H7 and Salmonella enterica from ready-to-eat meat samples. Food Microbiol. 2013, 33, 166–171. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  5. Mansouri, M.; Fathi, F.; Jalili, R.; Shoeibie, S.; Dastmalchi, S.; Khataee, A.; Rashidi, M.-R. SPR enhanced DNA biosensor for sensitive detection of donkey meat adulteration. Food Chem. 2020, 331, 127163. [Google Scholar] [CrossRef] [Scilit]
  6. Albelda, J.A.V.; Uzunoglu, A.; Santos, G.N.C.; Stanciu, L.A. Graphene-titanium dioxide nanocomposite based hypoxanthine sensor for assessment of meat freshness. Biosens. Bioelectron. 2017, 89, 518–524. [Google Scholar] [CrossRef] [Scilit]
  7. Nami, M.; Taheri, M.; Siddiqui, J.; Deen, I.A.; Packirisamy, M.; Deen, M.J. Recent Progress in Intelligent Packaging for Seafood and Meat Quality Monitoring. Adv. Mater. Technol. 2024, 9, 2301347. [Google Scholar] [CrossRef] [Scilit]
  8. Tsegay, Z.T.; Hosseini, E.; Varzakas, T.; Smaoui, S. The latest research progress on polysaccharides-based biosensors for food packaging: A review. Int. J. Biol. Macromol. 2024, 282, 136959. [Google Scholar] [CrossRef] [Scilit]
  9. Nanda, P.K.; Bhattacharya, D.; Das, J.K.; Bandyopadhyay, S.; Ekhlas, D.; Lorenzo, J.M.; Dandapat, P.; Alessandroni, L.; Das, A.K.; Gagaoua, M. Emerging Role of Biosensors and Chemical Indicators to Monitor the Quality and Safety of Meat and Meat Products. Chemosensors 2022, 10, 322. [Google Scholar] [CrossRef] [Scilit]
  10. Nastasijevic, I.; Kundacina, I.; Jaric, S.; Pavlovic, Z.; Radovic, M.; Radonic, V. Recent Advances in Biosensor Technologies for Meat Production Chain. Foods 2025, 14, 744. [Google Scholar] [CrossRef] [Scilit]
  11. ISO 22000; Food Safety Management Systems—Requirements for Any Organization in the Food Chain. International Standard; ISO: Geneva, Switzerland, 2018; pp. 1–48.
  12. Hosseinikebria, S.; Khazaei, M.; Dervisevic, M.; Judicpa, M.A.; Tian, J.; Razal, J.M.; Voelcker, N.H.; Nilghaz, A. Electrochemical biosensors: The beacon for food safety and quality. Food Chem. 2025, 475, 143284. [Google Scholar] [CrossRef] [Scilit]
  13. Wang, K.; Lin, X.; Zhang, M.; Li, Y.; Luo, C.; Wu, J. Review of Electrochemical Biosensors for Food Safety Detection. Biosensors 2022, 12, 959. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  14. Ruiz-Gonzalez, A. Ion-Selective Electrodes in the Food Industry: Development Trends in the Potentiometric Determination of Ionic Pollutants. Electrochem 2024, 5, 178–212. [Google Scholar] [CrossRef] [Scilit]
  15. Jasim, I.; Shen, Z.; Mlaji, Z.; Yuksek, N.S.; Abdullah, A.; Liu, J.; Dastider, S.G.; El-Dweik, M.; Zhang, S.; Almasri, M. An impedance biosensor for simultaneous detection of low concentration of Salmonella serogroups in poultry and fresh produce samples. Biosens. Bioelectron. 2019, 126, 292–300. [Google Scholar] [CrossRef] [Scilit]
  16. Liang, Q.; Zhou, D.; Zhang, K.; Camarada, M.B.; Xiong, J.; Liao, X. A novel portable electrochemical sensor based on post-synthetic modified Cu-MOF for highly sensitive electrochemical detection of pefloxacin in food samples. Microchem. J. 2025, 209, 112895. [Google Scholar] [CrossRef] [Scilit]
  17. Fritea, L.; Tertis, M.; Sandulescu, R.; Cristea, C. Chapter Eleven—Enzyme–Graphene Platforms for Electrochemical Biosensor Design With Biomedical Applications. In Methods in Enzymology; Kumar, C.V., Ed.; Academic Press: Cambridge, MA, USA, 2018; pp. 293–333. [Google Scholar] [CrossRef] [Scilit]
  18. Sun, G.; Wei, X.; Zhang, D.; Huang, L.; Liu, H.; Fang, H. Immobilization of Enzyme Electrochemical Biosensors and Their Application to Food Bioprocess Monitoring. Biosensors 2023, 13, 886. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  19. Torre, R.; Costa-Rama, E.; Lopes, P.; Nouws, H.P.A.; Delerue-Matos, C. Amperometric enzyme sensor for the rapid determination of histamine. Anal. Methods 2019, 11, 1264–1269. [Google Scholar] [CrossRef] [Scilit]
  20. Omanovic-Miklicanin, E.; Valzacchi, S. Development of new chemiluminescence biosensors for determination of biogenic amines in meat. Food Chem. 2017, 235, 98–103. [Google Scholar] [CrossRef] [Scilit]
  21. Garg, D.; Verma, N. Fibre-optic biosensor for the detection of xanthine for the evaluation of meat freshness. J. Phys. Conf. Ser. 2020, 1531, 012098. [Google Scholar] [CrossRef] [Scilit]
  22. Uwimbabazi, E.; Mukasekuru, M.R.; Sun, X. Glucose Biosensor Based on a Glassy Carbon Electrode Modified with Multi-Walled Carbon Nanotubes-Chitosan for the Determination of Beef Freshness. Food Anal. Methods 2017, 10, 2667–2676. [Google Scholar] [CrossRef] [Scilit]
  23. Vizzini, P.; Manzano, M.; Farre, C.; Meylheuc, T.; Chaix, C.; Ramarao, N.; Vidic, J. Highly sensitive detection of Campylobacter spp. in chicken meat using a silica nanoparticle enhanced dot blot DNA biosensor. Biosens. Bioelectron. 2021, 171, 112689. [Google Scholar] [CrossRef] [Scilit]
  24. Lee, I.-H.; Ma, L. Integrating machine learning, optical sensors, and robotics for advanced food quality assessment and food processing. Food Innov. Adv. 2025, 4, 65–72. [Google Scholar] [CrossRef] [Scilit]
  25. Koçoğlu, İ.O.; Erden, P.E.; Kılıç, E. Disposable biogenic amine biosensors for histamine determination in fish. Anal. Methods 2020, 12, 3802–3812. [Google Scholar] [CrossRef] [Scilit]
  26. Zór, K.; Dymek, K.; Ortiz, R.; Faure, A.M.; Saatci, E.; Gorton, L.; Bardsley, R.; Nistor, M. Indirect, non-competitive amperometric immunoassay for accurate quantification of calpastatin, a meat tenderness marker, in bovine muscle. Food Chem. 2012, 133, 598–603. [Google Scholar] [CrossRef] [Scilit]
  27. Pikkemaat, M.G.; Rapallini, M.L.; Karp, M.T.; Elferink, J.A. Application of a luminescent bacterial biosensor for the detection of tetracyclines in routine analysis of poultry muscle samples. Food Addit. Contam. Part A 2010, 27, 1112–1117. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  28. Swaidan, A.; Barras, A.; Addad, A.; Tahon, J.-F.; Toufaily, J.; Hamieh, T.; Szunerits, S.; Boukherroub, R. Colorimetric sensing of dopamine in beef meat using copper sulfide encapsulated within bovine serum albumin functionalized with copper phosphate (CuS-BSA-Cu3(PO4)2) nanoparticles. J. Colloid Interface Sci. 2021, 582, 732–740. [Google Scholar] [CrossRef] [Scilit]
  29. Pierini, G.D.; Robledo, S.N.; Zon, M.A.; Di Nezio, M.S.; Granero, A.M.; Fernández, H. Development of an electroanalytical method to control quality in fish samples based on an edge plane pyrolytic graphite electrode. Simultaneous determination of hypoxanthine, xanthine and uric acid. Microchem. J. 2018, 138, 58–64. [Google Scholar] [CrossRef] [Scilit]
  30. Guo, C.; You, S.; Li, C.; Chen, T.; Wang, X. One-Step and Colorimetric Detection of Fish Freshness Indicator Hypoxanthine Based on the Peroxidase Activity of Xanthine Oxidase Grade I Ammonium Sulfate Suspension. Front. Microbiol. 2021, 12, 791227. [Google Scholar] [CrossRef] [Scilit]
  31. Dervisevic, M.; Custiuc, E.; Çevik, E.; Durmus, Z.; Şenel, M.; Durmus, A. Electrochemical biosensor based on REGO/Fe3O4 bionanocomposite interface for xanthine detection in fish sample. Food Control 2015, 57, 402–410. [Google Scholar] [CrossRef] [Scilit]
  32. Chen, Z.; Lin, Y.; Ma, X.; Guo, L.; Qiu, B.; Chen, G.; Lin, Z. Multicolor biosensor for fish freshness assessment with the naked eye. Sens. Actuators B Chem. 2017, 252, 201–208. [Google Scholar] [CrossRef] [Scilit]
  33. Chen, J.; Lu, Y.; Yan, F.; Wu, Y.; Huang, D.; Weng, Z. A fluorescent biosensor based on catalytic activity of platinum nanoparticles for freshness evaluation of aquatic products. Food Chem. 2020, 310, 125922. [Google Scholar] [CrossRef] [Scilit]
  34. Mooltongchun, M.; Teepoo, S. A Simple and Cost-effective Microfluidic Paper-Based Biosensor Analytical Device and its Application for Hypoxanthine Detection in Meat Samples. Food Anal. Methods 2019, 12, 2690–2698. [Google Scholar] [CrossRef] [Scilit]
  35. Görgülü, M.; Servet, Ç.; Halit, A.; Yaşar, A. Preparing a new biosensor for hypoxanthine determination by immobilization of xanthine oxidase and uricase in polypyrrole-polyvinyl sulphonate film. Artif. Cells Nanomed. Biotechnol. 2013, 41, 327–331. [Google Scholar] [CrossRef] [Scilit]
  36. Devi, R.; Yadav, S.; Nehra, R.; Yadav, S.; Pundir, C.S. Electrochemical biosensor based on gold coated iron nanoparticles/chitosan composite bound xanthine oxidase for detection of xanthine in fish meat. J. Food Eng. 2013, 115, 207–214. [Google Scholar] [CrossRef] [Scilit]
  37. Zhang, Y.; Deng, S.; Lei, J.; Xu, Q.; Ju, H. Carbon nanospheres enhanced electrochemiluminescence of CdS quantum dots for biosensing of hypoxanthine. Talanta 2011, 85, 2154–2158. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  38. Martuscelli, M.; Esposito, L.; Mastrocola, D. Biogenic Amines’ Content in Safe and Quality Food. Foods 2021, 10, 100. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  39. Schirone, M.; Esposito, L.; FD’Onofrio Visciano, P.; Martuscelli, M.; Mastrocola, D.; Paparella, A. Biogenic Amines in Meat and Meat Products: A Review of the Science and Future Perspectives. Foods 2022, 11, 788. [Google Scholar] [CrossRef] [Scilit]
  40. Zhai, X.; Zou, X.; Shi, J.; Huang, X.; Sun, Z.; Li, Z.; Sun, Y.; Li, Y.; Wang, X.; Holmes, M.; et al. Amine-responsive bilayer films with improved illumination stability and electrochemical writing property for visual monitoring of meat spoilage. Sens. Actuators B Chem. 2020, 302, 127130. [Google Scholar] [CrossRef] [Scilit]
  41. Li, Y.-F.; Lin, Z.-Z.; Hong, C.-Y.; Huang, Z.-Y. Colorimetric detection of putrescine and cadaverine in aquatic products based on the mimic enzyme of (Fe,Co) codoped carbon dots. J. Food Meas. Charact. 2021, 15, 1747–1753. [Google Scholar] [CrossRef] [Scilit]
  42. Luo, Q.; Zhang, Y.; Zhou, Y.; Liu, S.G.; Gao, W.; Shi, X. Portable functional hydrogels based on silver metallization for visual monitoring of fish freshness. Food Control 2021, 123, 107824. [Google Scholar] [CrossRef] [Scilit]
  43. Matindoust, S.; Farzi, A.; Baghaei MNejad Shahrokh MHAbadi Zou, Z.; Zheng, L.-R. Ammonia gas sensor based on flexible polyaniline films for rapid detection of spoilage in protein-rich foods. J. Mater. Sci. Mater. Electron. 2017, 28, 7760–7768. [Google Scholar] [CrossRef] [Scilit]
  44. Chang, L.-Y.; Chuang, M.-Y.; Zan, H.-W.; Meng, H.-F.; Lu, C.-J.; Yeh, P.-H.; Chen, J.-N. One-Minute Fish Freshness Evaluation by Testing the Volatile Amine Gas with an Ultrasensitive Porous-Electrode-Capped Organic Gas Sensor System. ACS Sens. 2017, 2, 531–539. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  45. Shi, Y.; Li, Z.; Shi, J.; Zhang, F.; Zhou, X.; Li, Y.; Holmes, M.; Zhang, W.; Zou, X. Titanium dioxide-polyaniline/silk fibroin microfiber sensor for pork freshness evaluation. Sens. Actuators B Chem. 2018, 260, 465–474. [Google Scholar] [CrossRef] [Scilit]
  46. Li, H.; Chen, Q.; Zhao, J.; Wu, M. Nondestructive detection of total volatile basic nitrogen (TVB-N) content in pork meat by integrating hyperspectral imaging and colorimetric sensor combined with a nonlinear data fusion. LWT-Food Sci. Technol. 2015, 63, 268–274. [Google Scholar] [CrossRef] [Scilit]
  47. Ali, A.A.; Altemimi, A.B.; Alhelfi, N.; Ibrahim, S.A. Application of Biosensors for Detection of Pathogenic Food Bacteria: A Review. Biosensors 2020, 10, 58. [Google Scholar] [CrossRef] [Scilit]
  48. Ito, T.; Sekizuka, T.; Kishi, N.; Yamashita, A.; Kuroda, M. Conventional culture methods with commercially available media unveil the presence of novel culturable bacteria. Gut Microbes 2019, 10, 77–91. [Google Scholar] [CrossRef] [Scilit]
  49. Li, Z.; Lin, H.; Wang, L.; Cao, L.; Sui, J.; Wang, K. Optical sensing techniques for rapid detection of agrochemicals: Strategies, challenges, and perspectives. Sci. Total Environ. 2022, 838, 156515. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  50. Mendonça, M.; Conrad, N.L.; Conceição, F.R.; Moreira, Â.N.; da Silva, W.P.; Aleixo, J.A.G.; Bhunia, A.K. Highly specific fiber optic immunosensor coupled with immunomagnetic separation for detection of low levels of Listeria monocytogenes and L. ivanovii. BMC Microbiol. 2012, 12, 275. [Google Scholar] [CrossRef] [Scilit]
  51. Alhogail, S.; Suaifan, G.A.; Zourob, M. Rapid colorimetric sensing platform for the detection of Listeria monocytogenes foodborne pathogen. Biosens. Bioelectron. 2016, 86, 1061–1066. [Google Scholar] [CrossRef] [Scilit]
  52. Oh, S.Y.; Heo, N.S.; Shukla, S.; Cho, H.-J.; Vilian, A.T.E.; Kim, J.; Lee, S.Y.; Han, Y.-K.; Yoo, S.M.; Huh, Y.S. Development of gold nanoparticle-aptamer-based LSPR sensing chips for the rapid detection of Salmonella typhimurium in pork meat. Sci. Rep. 2017, 7, 10130. [Google Scholar] [CrossRef] [Scilit]
  53. Zhang, H.; Ma, X.; Liu, Y.; Duan, N.; Wu, S.; Wang, Z.; Xu, B. Gold nanoparticles enhanced SERS aptasensor for the simultaneous detection of Salmonella typhimurium and Staphylococcus aureus. Biosens. Bioelectron. 2015, 74, 872–877. [Google Scholar] [CrossRef] [Scilit]
  54. Liang, P.-S.; Park, T.S.; Yoon, J.-Y. Rapid and reagentless detection of microbial contamination within meat utilizing a smartphone-based biosensor. Sci. Rep. 2014, 4, 5953. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  55. Morant-Miñana, M.C.; Elizalde, J. Microscale electrodes integrated on COP for real sample Campylobacter spp. detection. Biosens. Bioelectron. 2015, 70, 491–497. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  56. Muniandy, S.; Dinshaw, I.J.; Teh, S.J.; Lai, C.W.; Ibrahim, F.; Thong, K.L.; Leo, B.F. Graphene-based label-free electrochemical aptasensor for rapid and sensitive detection of foodborne pathogen. Anal. Bioanal. Chem. 2017, 409, 6893–6905. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  57. Rasooly, A. Surface Plasmon Resonance Analysis of Staphylococcal Enterotoxin B in Food. J. Food Prot. 2001, 64, 37–43. [Google Scholar] [CrossRef] [Scilit]
  58. Liu, J.; Jasim, I.; Shen, Z.; Zhao, L.; Dweik, M.; Zhang, S.; Almasri, M. A microfluidic based biosensor for rapid detection of Salmonella in food products. PLoS ONE 2019, 14, e0216873. [Google Scholar] [CrossRef] [Scilit]
  59. Turdean, G.L. Design and Development of Biosensors for the Detection of Heavy Metal Toxicity. Int. J. Electrochem. 2011, 2011, 343125. [Google Scholar] [CrossRef] [Scilit]
  60. Cai, Y.; He, X.; Cui, P.L.; Liu, J.; Li, Z.B.; Jia, B.J.; Zhang, T.; Wang, J.P.; Yuan, W.Z. Preparation of a chemiluminescence sensor for multi-detection of benzimidazoles in meat based on molecularly imprinted polymer. Food Chem. 2019, 280, 103–109. [Google Scholar] [CrossRef] [Scilit]
  61. Wang, Y.; Zhang, L.; Peng, D.; Xie, S.; Chen, D.; Pan, Y.; Tao, Y.; Yuan, Z. Construction of Electrochemical Immunosensor Based on Gold-Nanoparticles/Carbon Nanotubes/Chitosan for Sensitive Determination of T-2 Toxin in Feed and Swine Meat. Int. J. Mol. Sci. 2018, 19, 3895. [Google Scholar] [CrossRef] [Scilit]
  62. Tang, D.; Tang, J.; Su, B.; Chen, G. Ultrasensitive Electrochemical Immunoassay of Staphylococcal Enterotoxin B in Food Using Enzyme-Nanosilica-Doped Carbon Nanotubes for Signal Amplification. J. Agric. Food Chem. 2010, 58, 10824–10830. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  63. Gao, D.; Guan, C.; Wen, Y.; Zhong, X.; Yuan, L. Multi-hole fiber based surface plasmon resonance sensor operated at near-infrared wavelengths. Opt. Commun. 2014, 313, 94–98. [Google Scholar] [CrossRef] [Scilit]
  64. McGrath, T.; Baxter, A.; Ferguson, J.; Haughey, S.; Bjurling, P. Multi sulfonamide screening in porcine muscle using a surface plasmon resonance biosensor. Anal. Chim. Acta 2005, 529, 123–127. [Google Scholar] [CrossRef] [Scilit]
  65. Yuan, J.; Oliver, R.; Aguilar, M.-I.; Wu, Y. Surface Plasmon Resonance Assay for Chloramphenicol. Anal. Chem. 2008, 80, 8329–8333. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  66. Mohammad-Razdari, A.; Ghasemi-Varnamkhasti, M.; Izadi, Z.; Rostami, S.; Ensafi, A.A.; Siadat, M.; Losson, E. Detection of sulfadimethoxine in meat samples using a novel electrochemical biosensor as a rapid analysis method. J. Food Compos. Anal. 2019, 82, 103252. [Google Scholar] [CrossRef] [Scilit]
  67. Stevenson, H.S.; Shetty, S.S.; Thomas, N.J.; Dhamu, V.N.; Bhide, A.; Prasad, S. Ultrasensitive and Rapid-Response Sensor for the Electrochemical Detection of Antibiotic Residues within Meat Samples. ACS Omega 2019, 4, 6324–6330. [Google Scholar] [CrossRef] [Scilit]
  68. Baş, S.Z.; Handan, G.; Yildiz, S. Hypoxanthine Biosensor Based on Immobilization of Xanthine Oxidase on Modified Pt Electrode and Its Application for Fish Meat. Int. J. Polym. Mater. Polym. Biomater. 2014, 63, 476–485. [Google Scholar] [CrossRef] [Scilit]
  69. Zhang, Y.; Xin, Y.; Yang, H.; Zhang, L.; Xia, X.; Tong, Y.; Chen, Y.; Ma, L.; Wang, W. Novel affinity purification of xanthine oxidase from Arthrobacter M3. J. Chromatogr. B 2012, 906, 19–24. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  70. Erol, E.; Yildirim, E.; Cete, S. Construction of biosensor for hypoxanthine determination by immobilization of xanthine oxidase and uricase in polypyrrole-paratoluenesulfonate film. J. Solid State Electrochem. 2020, 24, 1695–1707. [Google Scholar] [CrossRef] [Scilit]
  71. Torres, A.C.; Ghica, M.E.; Brett, C.M.A. Design of a new hypoxanthine biosensor: Xanthine oxidase modified carbon film and multi-walled carbon nanotube/carbon film electrodes. Anal. Bioanal. Chem. 2013, 405, 3813–3822. [Google Scholar] [CrossRef] [Scilit]
  72. Mustafa, F.; Andreescu, S. Paper-Based Enzyme Biosensor for One-Step Detection of Hypoxanthine in Fresh and Degraded Fish. ACS Sens. 2020, 5, 4092–4100. [Google Scholar] [CrossRef] [Scilit]
  73. Bratcher, C.L.; Grant, S.A.; Vassalli, J.T.; Lorenzen, C.L. Enhanced efficiency of a capillary-based biosensor over an optical fiber biosensor for detecting calpastatin. Biosens. Bioelectron. 2008, 23, 1674–1679. [Google Scholar] [CrossRef] [Scilit]
  74. Costa, C.A.B.; Grazhdan, D.; Fiutowski, J.; Nebling, E.; Blohm, L.; Lofink, F.; Rubahn, H.-G.; de Oliveira Hansen, R. Meat and fish freshness evaluation by functionalized cantilever-based biosensors. Microsyst. Technol. 2020, 26, 867–871. [Google Scholar] [CrossRef] [Scilit]
  75. Zór, K.; Castellarnau, M.; Pascual, D.; Pich, S.; Plasencia, C.; Bardsley, R.; Nistor, M. Design, development and application of a bioelectrochemical detection system for meat tenderness prediction. Biosens. Bioelectron. 2011, 26, 4283–4288. [Google Scholar] [CrossRef] [Scilit]
  76. Liu, G.; Chai, C.; Yao, B. Rapid evaluation of Salmonella pullorum contamination in chicken based on a portable amperometric sensor. J. Biosens. Bioelectron 2013, 137, 2. [Google Scholar]
  77. Helali, S.; Sawelem Eid Alatawi, A.; Abdelghani, A. Pathogenic Escherichia coli biosensor detection on chicken food samples. J. Food Saf. 2018, 38, e12510. [Google Scholar] [CrossRef] [Scilit]
  78. Banerjee, P.; Bhunia, A.K. Cell-based biosensor for rapid screening of pathogens and toxins. Biosens. Bioelectron. 2010, 26, 99–106. [Google Scholar] [CrossRef] [Scilit]
  79. Ferguson, J.; Baxter, A.; Young, P.; Kennedy, G.; Elliott, C.; Weigel, S.; Gatermann, R.; Ashwin, H.; Stead, S.; Sharman, M. Detection of chloramphenicol and chloramphenicol glucuronide residues in poultry muscle, honey, prawn and milk using a surface plasmon resonance biosensor and Qflex® kit chloramphenicol. Anal. Chim. Acta 2005, 529, 109–113. [Google Scholar] [CrossRef] [Scilit]
  80. Wu, Y.-Y.; Huang, P.; Wu, F.-Y. A label-free colorimetric aptasensor based on controllable aggregation of AuNPs for the detection of multiplex antibiotics. Food Chem. 2020, 304, 125377. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  81. Lu, X.; Zheng, H.; Li, X.-Q.; Yuan, X.-X.; Li, H.; Deng, L.-G.; Zhang, H.; Wang, W.-Z.; Yang, G.-S.; Meng, M.; et al. Detection of ractopamine residues in pork by surface plasmon resonance-based biosensor inhibition immunoassay. Food Chem. 2012, 130, 1061–1065. [Google Scholar] [CrossRef] [Scilit]
  82. Chen, X.; Yao, C.; Li, Z. Microarray-based chemical sensors and biosensors: Fundamentals and food safety applications. TrAC Trends Anal. Chem. 2023, 158, 116785. [Google Scholar] [CrossRef] [Scilit]
  83. Romanholo, P.V.V.; Sgobbi, L.F. Chapter 4—Validation of biosensors. In Biosensors in Precision Medicine; Brazaca, L.C., Sempionatto, J.R., Eds.; Elsevier: Amsterdam, The Netherlands, 2024; pp. 105–131. [Google Scholar] [CrossRef] [Scilit]
  84. Zhang, J.; Huang, H.; Song, G.; Huang, K.; Luo, Y.; Liu, Q.; He, X.; Cheng, N. Intelligent biosensing strategies for rapid detection in food safety: A review. Biosens. Bioelectron. 2022, 202, 114003. [Google Scholar] [CrossRef] [Scilit]
  85. EMA—European Medicines Agency. Implementation Strategy of ICH Guideline M10 on Bioanalytical Method Validation 2024. Available online: https://www.ema.europa.eu/en/documents/scientific-guideline/implementation-strategy-ich-guideline-m10-bioanalytical-method-validation_en.pdf (accessed on 11 June 2025).
  86. ICH Expert Working Group. ICH Guideline M10 on Bioanalytical Method Validation and Study Sample Analysis 2022. Available online: https://database.ich.org/sites/default/files/M10_Guideline_Step4_2022_0524.pdf (accessed on 5 May 2025).
  87. U.S. Department of Health and Human Services Food and Drug Administration. M10 Bioanalytical Method Validation and Study Sample Analysis Guidance for Industry 2022. Available online: https://www.fda.gov/media/162903/download (accessed on 5 May 2025).
  88. IUPAC. Compendium of Terminology in Analytical Chemistry; Hibbert, D.B., Ed.; The Royal Society of Chemistry: London, UK, 2023. [Google Scholar] [CrossRef] [Scilit]
  89. Vazvaei-Smith, F.; Wickremsinhe, E.; Woolf, E.; Yu, C. ICH M10 Bioanalytical Method Validation Guideline-1 year Later. AAPS J. 2024, 26, 103. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  90. Ávila Oliveira, B.D.; Gomes, R.S.; de Carvalho, A.M.; Lima, E.M.F.; Pinto, U.M.; da Cunha, L.R. Revolutionizing food safety with electrochemical biosensors for rapid and portable pathogen detection. Braz. J. Microbiol. 2024, 55, 2511–2525. [Google Scholar] [CrossRef] [Scilit]
  91. Ozkan, S.A.; Uslu, B.; Sezgintürk, M.K. Validation Requirements in Biosensors. In Biosensors: Fundamentals, Emerging Technologies, and Applications; CRC Press: Boca Raton, FL, USA, 2022. [Google Scholar] [CrossRef] [Scilit]
  92. Nath, S. Advancements in food quality monitoring: Integrating biosensors for precision detection. Sustain. Food Technol. 2024, 2, 976–992. [Google Scholar] [CrossRef] [Scilit]
  93. Indyk, H.E.; Woollard, D.C. Single laboratory validation of an optical biosensor method for the determination of folate in foods. J. Food Compos. Anal. 2013, 29, 87–93. [Google Scholar] [CrossRef] [Scilit]
  94. Schulze, H.; Scherbaum, E.; Anastassiades, M.; SVorlová; Schmid, R.D.; Bachmann, T.T. Development, validation, and application of an acetylcholinesterase-biosensor test for the direct detection of insecticide residues in infant food. Biosens. Bioelectron. 2002, 17, 1095–1105. [Google Scholar] [CrossRef] [Scilit]
  95. Thakur, M.S.; Ragavan, K.V. Biosensors in food processing. J. Food Sci. Technol. 2013, 50, 625–641. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  96. Meliana, C.; Jingjing, L.; Loke, S.P.; Low, S.S. Biosensor in smart food traceability system for food safety and security. Bioengineered 2024, 15, 2310908. [Google Scholar] [CrossRef] [Scilit]
  97. Wijayanti, S.D.; Tsvik, L.; Haltrich, D. Recent Advances in Electrochemical Enzyme-Based Biosensors for Food and Beverage Analysis. Foods 2023, 12, 3355. [Google Scholar] [CrossRef] [Scilit]
  98. Curulli, A. Electrochemical Biosensors in Food Safety: Challenges and Perspectives. Molecules 2021, 26, 2940. [Google Scholar] [CrossRef] [Scilit]
  99. Inês, A.; Cosme, F. Biosensors for Detecting Food Contaminants—An Overview. Processes 2025, 13, 380. [Google Scholar] [CrossRef] [Scilit]
  100. Lv, M.; Liu, Y.; Geng, J.; Kou, X.; Xin, Z.; Yang, D. Engineering nanomaterials-based biosensors for food safety detection. Biosens. Bioelectron. 2018, 106, 122–128. [Google Scholar] [CrossRef] [Scilit]
  101. Griesche, C.; Baeumner, A.J. Biosensors to support sustainable agriculture and food safety. TrAC Trends Anal. Chem. 2020, 128, 115906. [Google Scholar] [CrossRef] [Scilit]
  102. Ouyang, Q.; Wang, L.; Ahmad, W.; Rong, Y.; Li, H.; Hu, Y.; Chen, Q. A highly sensitive detection of carbendazim pesticide in food based on the upconversion-MnO2 luminescent resonance energy transfer biosensor. Food Chem. 2021, 349, 129157. [Google Scholar] [CrossRef] [Scilit]
  103. Yang, J.; Zhang, Y.; Luo, G.; Zheng, S.; Han, S.; Liang, S.; Lin, Y. Collaborative light-off and light-on bacterial luciferase biosensors: Innovative approach for rapid contaminant detection. Biosens. Bioelectron. 2025, 280, 117369. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  104. Jadán, F.; Aristoy, M.-C.; Toldrá, F. Biosensor Based on Immobilized Nitrate Reductase for the Quantification of Nitrate Ions in Dry-Cured Ham. Food Anal. Methods 2017, 10, 3481–3486. [Google Scholar] [CrossRef] [Scilit]
  105. Zhao, L.; Guo, H.; Chen, H.; Zou, B.; Yang, C.; Zhang, X.; Gao, Y.; Sun, M.; Wang, L. A Rapid and Sensitive Aptamer-Based Biosensor for Amnesic Shellfish Toxin Domoic Acid. Bioengineering 2022, 9, 684. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  106. Fonfría, E.S.; NVilariño Campbell, K.; Elliott, C.; Haughey, S.A.; BBen-Gigirey Vieites, J.M.; Kawatsu, K.; Botana, L.M. Paralytic Shellfish Poisoning Detection by Surface Plasmon Resonance-Based Biosensors in Shellfish Matrixes. Anal. Chem. 2007, 79, 6303–6311. [Google Scholar] [CrossRef] [Scilit]
  107. Baskaran, N.; Sakthivel, R.; Karthik, C.S.; Lin, Y.-C.; Liu, X.; Wen, H.-W.; Yang, W.; Chung, R.-J. Polydopamine-modified 3D flower-like ZnMoO4 integrated MXene-based label-free electrochemical immunosensor for the food-borne pathogen Listeria monocytogenes detection in milk and seafood. Talanta 2025, 282, 127008. [Google Scholar] [CrossRef] [Scilit]
  108. Bahadır, E.B.; Sezgintürk, M.K. Applications of commercial biosensors in clinical, food, environmental, and biothreat/biowarfare analyses. Anal. Biochem. 2015, 478, 107–120. [Google Scholar] [CrossRef] [Scilit]
  109. Radhakrishnan, R.; Suni, I.I.; Bever, C.S.; Hammock, B.D. Impedance Biosensors: Applications to Sustainability and Remaining Technical Challenges. ACS Sustain. Chem. Eng. 2014, 2, 1649–1655. [Google Scholar] [CrossRef] [Scilit]
  110. Yibar, A.; Ajmi, N.; Duman, M. First report and genomic characterization of Escherichia coli O111:H12 serotype from raw mussels in Türkiye. BMC Genom. 2024, 25, 1027. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  111. Li, P.; Long, F.; Chen, W.; Chen, J.; Chu, P.K.; Wang, H. Fundamentals and applications of surface-enhanced Raman spectroscopy–based biosensors. Curr. Opin. Biomed. Eng. 2020, 13, 51–59. [Google Scholar] [CrossRef] [Scilit]
  112. Boodhoo, N.; Shoja, J.; Doost, S. Sharif Biosensors for Monitoring, Detecting, and Tracking Dissemination of Poultry-Borne Bacterial Pathogens Along the Poultry Value Chain: A Review. Animals 2024, 14, 3138. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  113. Masdor, N.A.; Altintas, Z.; Tothill, I.E. Surface Plasmon Resonance Immunosensor for the Detection of Campylobacter jejuni. Chemosensors 2017, 5, 16. [Google Scholar] [CrossRef] [Scilit]
  114. Zhang, H.; Zhou, L.; Zhu, Z.; Yang, C. Recent Progress in Aptamer-Based Functional Probes for Bioanalysis and Biomedicine. Chem.–A Eur. J. 2016, 22, 9886–9900. [Google Scholar] [CrossRef] [Scilit]
  115. Mak, W.C.; Beni, V.; Turner, A.P.F. Lateral-flow technology: From visual to instrumental. TrAC Trends Anal. Chem. 2016, 79, 297–305. [Google Scholar] [CrossRef] [Scilit]
  116. Sharma, P.; Thakur, D.; Kumar, D. Novel Enzymatic Biosensor Utilizing a MoS2/MoO3 Nanohybrid for the Electrochemical Detection of Xanthine in Fish Meat. ACS Omega 2023, 8, 31962–31971. [Google Scholar] [CrossRef] [Scilit]
  117. Callaway, T.R.; Lillehoj, H.; Chuanchuen, R.; Gay, C.G. Alternatives to Antibiotics: A Symposium on the Challenges and Solutions for Animal Health and Production. Antibiotics 2021, 10, 471. [Google Scholar] [CrossRef] [Scilit]
  118. Laxminarayan, R.; Duse, A.; Wattal, C.; Zaidi, A.K.M.; Wertheim, H.F.L.; Sumpradit, N.; Vlieghe, E.; Levi Hara, G.; Gould, I.M.; Goossens, H.; et al. Antibiotic resistanc—The need for global solutions. Lancet Infect. Dis. 2013, 13, 1057–1098. [Google Scholar] [CrossRef] [Scilit]
  119. Carlet, J. The gut is the epicentre of antibiotic resistance. Antimicrob. Resist. Infect. Control 2012, 1, 39. [Google Scholar] [CrossRef] [Scilit]
  120. Er, B.; Onurdağ, F.K.; Demirhan, B.; Özgacar, S.Ö.; Öktem, A.B.; Abbasoğlu, U. Screening of quinolone antibiotic residues in chicken meat and beef sold in the markets of Ankara, Turkey. Poult. Sci. 2013, 92, 2212–2215. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  121. Zhai, S.; Zhu, Y.; Feng, P.; Li, M.; Wang, W.; Yang, L.; Yang, Y. Ochratoxin A: Its impact on poultry gut health and microbiota, an overview. Poult. Sci. 2021, 100, 101037. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  122. Lozano, M.C.; Diaz, G.J. Microsomal and cytosolic biotransformation of aflatoxin B1 in four poultry species. Br. Poult. Sci. 2006, 47, 734–741. [Google Scholar] [CrossRef] [Scilit]
  123. Manessis, G.; Gelasakis, A.I.; Bossis, I. Point-of-Care Diagnostics for Farm Animal Diseases: From Biosensors to Integrated Lab-on-Chip Devices. Biosensors 2022, 12, 455. [Google Scholar] [CrossRef] [Scilit]
  124. Trinh, T.N.; Nguyen, H.A.; Thi, N.P.; Nam, N.N.; Tran, N.K.; Trinh, K.T. Biosensors for Seafood Safety Control—A Review. Micromachines 2024, 15, 1509. [Google Scholar] [CrossRef] [Scilit]
  125. Jiang, H.; Sun, Z.; Guo, Q.; Weng, X. Microfluidic thread-based electrochemical aptasensor for rapid detection of Vibrio parahaemolyticus. Biosens. Bioelectron. 2021, 182, 113191. [Google Scholar] [CrossRef] [Scilit]
  126. Villalonga, A.; Sánchez, A.; Mayol, B.; Reviejo, J.; Villalonga, R. Electrochemical biosensors for food bioprocess monitoring. Curr. Opin. Food Sci. 2022, 43, 18–26. [Google Scholar] [CrossRef] [Scilit]
  127. López, M.A.; Moreno-Guzman, M.; Jurado, B.; Escarpa, A. Chapter 9—Food Microfluidics Biosensors. In Comprehensive Analytical Chemistry; Scognamiglio, V., Rea, G., Arduini, F., Palleschi, G., Eds.; Elsevier: Amsterdam, The Netherlands, 2016; pp. 273–312. [Google Scholar] [CrossRef] [Scilit]
  128. Yang, F.-Q.; Ge, L. Colorimetric Sensors: Methods and Applications. Sensors 2023, 23, 9887. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  129. Cui, Y.; Zhao, J.; Li, H. Chromogenic Mechanisms of Colorimetric Sensors Based on Gold Nanoparticles. Biosensors 2023, 13, 801. [Google Scholar] [CrossRef] [Scilit]
  130. Chi, J.; Ju, P.; Bi, F.; Wen, S.; Xiang, Z.; Chen, J.; Qiu, M. A smartphone-assisted ultrasensitive colorimetric aptasensor based on DNA-encoded porous MXene nanozyme for visual detection of okadaic acid. Food Chem. 2025, 464, 141776. [Google Scholar] [CrossRef] [Scilit]
  131. Roda, A.; Michelini, E.; Zangheri, M.; Di Fusco, M.; Calabria, D.; Simoni, P. Smartphone-based biosensors: A critical review and perspectives. TrAC Trends Anal. Chem. 2016, 79, 317–325. [Google Scholar] [CrossRef] [Scilit]
  132. Pan, Y.; Xu, S.; Wang, Z.; Jiang, C.; Ma, X. Sensitive SERS aptasensor for histamine detection based on Au/Ag nanorods and IRMOF-3@Au based flexible PDMS membrane. Anal. Chim. Acta 2024, 1288, 342147. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  133. Lee, S.; Dang, H.; Moon, J.-I.; Kim, K.; Joung, Y.; Park, S.; Yu, Q.; Chen, J.; Lu, M.; Chen, L.; et al. SERS-based microdevices for use as in vitro diagnostic biosensors. Chem. Soc. Rev. 2024, 53, 5394–5427. [Google Scholar] [CrossRef] [Scilit]
  134. Chauhan, N.; Saxena, K.; Rawal, R.; Yadav, L.; Jain, U. Advances in surface-enhanced Raman spectroscopy-based sensors for detection of various biomarkers. Prog. Biophys. Mol. Biol. 2023, 184, 32–41. [Google Scholar] [CrossRef] [Scilit]
  135. Usman, F.; Ghazali, K.H.; Fen, Y.W.; Meriaudeau, F.; Jose, R. Biosensing through surface enhanced Raman spectroscopy: A review on the role of plasmonic nanoparticle-polymer composites. Eur. Polym. J. 2023, 195, 112250. [Google Scholar] [CrossRef] [Scilit]
  136. Zhou, J.-Y.; Zhu, J.; Weng, G.-J.; Li, J.-J.; Zhao, J.-W. Fabrication of SERS composite substrates using Ag nanotriangles-modified SiO2 photonic crystal and the application of malachite green detection. Spectrochim. Acta Part A Mol. Biomol. Spectrosc. 2024, 318, 124472. [Google Scholar] [CrossRef] [Scilit]
  137. Li, K.; Li, H.; Yin, M.; Yang, D.; Xiao, F.; Tammina, S.K.; Yang, Y. Fluorescence-SERS dual-mode for sensing histamine on specific binding histamine-derivative and gold nanoparticles. Spectrochim. Acta Part A Mol. Biomol. Spectrosc. 2022, 273, 121047. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  138. Ravindran, N.; Sandhya, K.; Yashini, M.; Rajeshwari, S.; Mamathi, C.A.; Nirmal, T.S.; CK, S. Recent advances in Surface Plasmon Resonance (SPR) biosensors for food analysis: A review. Crit. Rev. Food Sci. Nutr. 2023, 63, 1055–1077. [Google Scholar] [CrossRef] [Scilit]
  139. Zhou, J.; Qi, Q.; Wang, C.; Qian, Y.; Liu, G.; Wang, Y.; Fu, L. Surface plasmon resonance (SPR) biosensors for food allergen detection in food matrices. Biosens. Bioelectron. 2019, 142, 111449. [Google Scholar] [CrossRef] [Scilit]
  140. Ramezani, M.; Esmaelpourfarkhani, M.; Taghdisi, S.M.; Abnous, K.; Alibolandi, M. Chapter 22—Application of nanosensors for food safety. In Nanosensors for Smart Cities; Han, B., Tomer, V.K., Nguyen, Farmani, T.A., Kumar, A., Singh, P., Eds.; Elsevier: Amsterdam, The Netherlands, 2020; pp. 369–386. [Google Scholar] [CrossRef] [Scilit]
  141. Prodromidis, M.I. Impedimetric immunosensors—A review. Electrochim. Acta 2010, 55, 4227–4233. [Google Scholar] [CrossRef] [Scilit]
  142. Bosona, T.; Gebresenbet, G. Food traceability as an integral part of logistics management in food and agricultural supply chain. Food Control 2013, 33, 32–48. [Google Scholar] [CrossRef] [Scilit]
  143. Arshad, F.; Abdillah, A.N.; Shivanand, P.; Ahmed, M.U. CeO2 nanozyme mediated RPA/CRISPR-Cas12a dual-mode biosensor for detection of invA gene in Salmonella. Biosens. Bioelectron. 2024, 247, 115940. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  144. Zhu, L.; Liang, Z.; Xu, Y.; Chen, Z.; Wang, J.; Zhou, L. Ultrasensitive and Rapid Visual Detection of Escherichia coli O157:H7 Based on RAA-CRISPR/Cas12a System. Biosensors 2023, 13, 659. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  145. Wang, J.Y.; Tuck, O.T.; Skopintsev, P.; Soczek, K.M.; Li, G.; Al-Shayeb, B.; Zhou, J.; Doudna, J.A. Genome expansion by a CRISPR trimmer-integrase. Nature 2023, 618, 855–861. [Google Scholar] [CrossRef] [Scilit]
  146. Mohtar, L.G.; Aranda, P.; Messina, G.A.; Nazareno, M.A.; Pereira, S.V.; Raba, J.; Bertolino, F.A. Amperometric biosensor based on laccase immobilized onto a nanostructured screen-printed electrode for determination of polyphenols in propolis. Microchem. J. 2019, 144, 13–18. [Google Scholar] [CrossRef] [Scilit]
  147. Ye, Y.; Ji, J.; Sun, Z.; Shen, P.; Sun, X. Recent advances in electrochemical biosensors for antioxidant analysis in foodstuff. TrAC Trends Anal. Chem. 2020, 122, 115718. [Google Scholar] [CrossRef] [Scilit]
  148. Weng, X.; Neethirajan, S. Ensuring food safety: Quality monitoring using microfluidics. Trends Food Sci. Technol. 2017, 65, 10–22. [Google Scholar] [CrossRef] [Scilit]
  149. Sonu; Chaudhary, V. A Paradigm of Internet-of-Nano-Things Inspired Intelligent Plant Pathogen-Diagnostic Biosensors. ECS Sens. Plus 2022, 1, 031401. [Google Scholar] [CrossRef] [Scilit]
  150. Ariyarathna, I.R.; Rajakaruna, R.M.P.I.; Karunaratne, D.N. The rise of inorganic nanomaterial implementation in food applications. Food Control 2017, 77, 251–259. [Google Scholar] [CrossRef] [Scilit]
  151. Verma, N.; Kaur, G. Chapter 2—Trends on Biosensing Systems for Heavy Metal Detection. In Comprehensive Analytical Chemistry; Scognamiglio, V., Rea, G., Arduini, F., Palleschi, G., Eds.; Elsevier: Amsterdam, The Netherlands, 2016; pp. 33–71. [Google Scholar] [CrossRef] [Scilit]
  152. Pawar, D.; Lo Presti, D.; Silvestri, S.; Schena, E.; Massaroni, C. Current and future technologies for monitoring cultured meat: A review. Food Res. Int. 2023, 173, 113464. [Google Scholar] [CrossRef] [Scilit]
  153. FAO. Food Safety Aspects of Cell-Based Food—Background Document Two: Generic Production Process; FAO, Ed.; FAO: Rome, Italy, 2022. [Google Scholar]
  154. Dudefoi, W.; Villares, A.; Peyron, S.; Moreau, C.; Ropers, M.-H.; Gontard, N.; Cathala, B. Nanoscience and nanotechnologies for biobased materials, packaging and food applications: New opportunities and concerns. Innov. Food Sci. Emerg. Technol. 2018, 46, 107–121. [Google Scholar] [CrossRef] [Scilit]
  155. Hao, S.; Sun, X.; Zhang, H.; Zhai, J.; Dong, S. Recent development of biofuel cell based self-powered biosensors. J. Mater. Chem. B 2020, 8, 3393–3407. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  156. Zhang, D.; Liu, Q. Biosensors and bioelectronics on smartphone for portable biochemical detection. Biosens. Bioelectron. 2016, 75, 273–284. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  157. Kim, J.; Imani, S.; de Araujo, W.R.; Warchall, J.; GValdés-Ramírez Paixão, T.R.L.C.; Mercier, P.P.; Wang, J. Wearable salivary uric acid mouthguard biosensor with integrated wireless electronics. Biosens. Bioelectron. 2015, 74, 1061–1068. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  158. Zhou, Q.; Kannan, P.; Natarajan, B.; Maiyalagan, T.; Subramanian, P.; Jiang, Z.; Mao, S. MnO2 cacti-like nanostructured platform powers the enhanced electrochemical immunobiosensing of cortisol. Sens. Actuators B Chem. 2020, 317, 128134. [Google Scholar] [CrossRef] [Scilit]
  159. Piñeiro, M.; Morales, J.; Vizcaíno, E.; Murillo, J.A.; Klauke, T.; Petersen, B.; Piñeiro, C. The use of acute phase proteins for monitoring animal health and welfare in the pig production chain: The validation of an immunochromatographic method for the detection of elevated levels of pig-MAP. Meat Sci. 2013, 95, 712–718. [Google Scholar] [CrossRef] [Scilit]
  160. Neethirajan, S. Recent advances in wearable sensors for animal health management. Sens. Bio-Sens. Res. 2017, 12, 15–29. [Google Scholar] [CrossRef] [Scilit]
  161. Land, K.J.; Boeras, D.I.; Chen, X.-S.; Ramsay, A.R.; Peeling, R.W. Reassured diagnostics to inform disease control strategies, strengthen health systems and improve patient outcomes. Nat. Microbiol. 2019, 4, 46–54. [Google Scholar] [CrossRef] [Scilit]
  162. Lin, K.; Chavalarias, D.; Panahi, M.; Yeh, T.; Takimoto, K.; Mizoguchi, M. Mobile-based traceability system for sustainable food supply networks. Nat. Food 2020, 1, 673–679. [Google Scholar] [CrossRef] [Scilit]
  163. Abdelbasset, W.K.; Savina, S.V.; Mavaluru, D.; Shichiyakh, R.A.; Bokov, D.O.; Mustafa, Y.F. Smartphone based aptasensors as intelligent biodevice for food contamination detection in food and soil samples: Recent advances. Talanta 2023, 252, 123769. [Google Scholar] [CrossRef] [Scilit]
  164. Zhang, Y.; Lin, T.; Shen, Y.; Li, H. A High-Performance Self-Supporting Electrochemical Biosensor to Detect Aflatoxin B1. Biosensors 2022, 12, 897. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  165. Xie, Y.; Lu, L.; Gao, F.; He, S.; Zhao, H.; Fang, Y.; Yang, J.; An, Y.; Ye, Z.-W.; Dong, Z. Integration of Artificial Intelligence, Blockchain, and Wearable Technology for Chronic Disease Management: A New Paradigm in Smart Healthcare. Curr. Med. Sci. 2021, 41, 1123–1133. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  166. WHO. Food Safety (19 May 2022); WHO: Geneva, Switzerland, 2022. [Google Scholar]
  167. Chen, S.; Brahma, S.; Mackay, J.; Cao, C.; Aliakbarian, B. The role of smart packaging system in food supply chain. J. Food Sci. 2020, 85, 517–525. [Google Scholar] [CrossRef] [Scilit]
  168. Li, F.; Ye, Q.; Chen, M.; Zhou, B.; Zhang, J.; Pang, R.; Xue, L.; Wang, J.; Zeng, H.; Wu, S.; et al. An ultrasensitive CRISPR/Cas12a based electrochemical biosensor for Listeria monocytogenes detection. Biosens. Bioelectron. 2021, 179, 113073. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  169. Ma, L.; Peng, L.; Yin, L.; Liu, G.; Man, S. CRISPR-Cas12a-Powered Dual-Mode Biosensor for Ultrasensitive and Cross-validating Detection of Pathogenic Bacteria. ACS Sens. 2021, 6, 2920–2927. [Google Scholar] [CrossRef] [Scilit]
  170. Yang, L.; Xu, X.; Song, Y.; Huang, J.; Xu, H. Research progress of nanozymes in colorimetric biosensing: Classification, activity and application. Chem. Eng. J. 2024, 487, 150612. [Google Scholar] [CrossRef] [Scilit]
  171. Sun, Z.; Zhang, B.; Tu, H.; Pan, C.; Chai, Y.; Chen, W. Advances in colorimetric biosensors of exosomes: Novel approaches based on natural enzymes and nanozymes. Nanoscale 2024, 16, 1005–1024. [Google Scholar] [CrossRef] [Scilit]
  172. Zhao, F.; Wang, L.; Li, M.; Wang, M.; Liu, G.; Ping, J. Nanozyme-based biosensor for organophosphorus pesticide monitoring: Functional design, biosensing strategy, and detection application. TrAC Trends Anal. Chem. 2023, 165, 117152. [Google Scholar] [CrossRef] [Scilit]
  173. Zhang, Z.; Liu, D.; Zhang, X.; Luo, X.; Lin, W.; Li, Z.; Huang, J. Silver nanoparticles deposited carbon microspheres nanozyme with enhanced peroxidase-like catalysis for colorimetric detection of Hg2+ in seafood. Microchim. Acta 2023, 190, 340. [Google Scholar] [CrossRef] [Scilit]
  174. Li, J.; Lin, X.; Wu, J.; Ying, D.; Duan, N.; Wang, Z.; Wu, S. Multifunctional magnetic composite nanomaterial for Colorimetric-SERS Dual-Mode detection and photothermal sterilization of Vibrio parahaemolyticus. Chem. Eng. J. 2023, 477, 147113. [Google Scholar] [CrossRef] [Scilit]
  175. Ayerdurai, V.; Cieplak, M.; Kutner, W. Molecularly imprinted polymer-based electrochemical sensors for food contaminants determination. TrAC Trends Anal. Chem. 2023, 158, 116830. [Google Scholar] [CrossRef] [Scilit]
  176. Munir, M.A.; Rahmawati, F.; Jamal, J.A.; Ibrahim, S.; Said, M.M.; Ahmad, M.S. Inspecting Histamine Isolated from Fish through a Highly Selective Molecularly Imprinted Electrochemical Sensor Approach. ACS Omega 2023, 8, 13352–13361. [Google Scholar] [CrossRef] [Scilit]
  177. Ding, S.-J.; Chang, B.-W.; Wu, C.-C.; Chen, C.-J.; Chang, H.-C. A new method for detection of endotoxin on polymyxin B-immobilized gold electrodes. Electrochem. Commun. 2007, 9, 1206–1211. [Google Scholar] [CrossRef] [Scilit]
  178. Su, W.; Lin, M.; Lee, H.; Cho, M.; Choe, W.-S.; Lee, Y. Determination of endotoxin through an aptamer-based impedance biosensor. Biosens. Bioelectron. 2012, 32, 32–36. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  179. Kubicek-Sutherland, J.Z.; Vu, D.M.; Noormohamed, A.; Mendez, H.M.; Stromberg, L.R.; Pedersen, C.A.; Hengartner, A.C.; Klosterman, K.E.; Bridgewater, H.A.; Otieno, V.; et al. Direct detection of bacteremia by exploiting host-pathogen interactions of lipoteichoic acid and lipopolysaccharide. Sci. Rep. 2019, 9, 6203. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  180. Wang, L.; He, Y.; Wu, Z. Design of a Blockchain-Enabled Traceability System Framework for Food Supply Chains. Foods 2022, 11, 744. [Google Scholar] [CrossRef] [Scilit]
  181. Mustafa, F.; Othman, A.; Andreescu, S. Cerium oxide-based hypoxanthine biosensor for Fish spoilage monitoring. Sens. Actuators B Chem. 2021, 332, 129435. [Google Scholar] [CrossRef] [Scilit]
  182. Cheng, X.; Liu, W.; Wang, Z.; Yang, R.; Yu, L.; Du, Q.; Ge, A.; Liu, C.; Chi, Z. Improved triple-module fluorescent biosensor for the rapid and ultrasensitive detection of Campylobacter jejuni in livestock and dairy. Food Control 2022, 137, 108905. [Google Scholar] [CrossRef] [Scilit]
  183. Das, A.; Terry, L.R.; Guo, H. A surface-enhanced Raman spectroscopy based smart Petri dish for sensitive and rapid detection of bacterial contamination in shrimp. Food Chem. Adv. 2023, 2, 100222. [Google Scholar] [CrossRef] [Scilit]
  184. Guo, H.; Li, Y.; Pi, F. Sensitive and reproducible gold nanostar@metal–organic framework-based SERS membranes for the online monitoring of the freshness of shrimps. Analyst 2023, 148, 2081–2091. [Google Scholar] [CrossRef] [Scilit]
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Article Metrics

Citations

Article Access Statistics

Multiple requests from the same IP address are counted as one view.