Next Article in Journal
Laryngeal Electromyography as a Predictive Factor in the Evolution of Unilateral Recurrent Paralysis Post-Thyroidectomy
Next Article in Special Issue
What Are SAVR Indications in the TAVI Era?
Previous Article in Journal
Comparison of the Acute Effects of Auricular Vagus Nerve Stimulation and Deep Breathing Exercise on the Autonomic Nervous System Activity and Biomechanical Properties of the Muscle in Healthy People
Previous Article in Special Issue
Analysis of Calcium Patterns in the Thoracic Aorta and Clinical Outcomes of TAVR Patients Presenting with Porcelain Aorta
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

The Impact of Aortic Arch Morphology on Periprocedural Stroke in Transcatheter Aortic Valve Replacement

1
Department of Cardiovascular Surgery, Institute Insure, German Heart Centre Munich, School of Medicine & Health, Technical University of Munich, Lazarettstrasse 36, 80636 Munich, Germany
2
Division of Cardiac Surgery, Department of Cardiothoracic Surgery, University of Pittsburgh, Pittsburgh, PA 15213, USA
3
UPMC Heart and Vascular Institute, University of Pittsburgh Medical Center, Pittsburgh, PA 15219, USA
4
DZHK (German Centre for Cardiovascular Research)—Partner Site Munich Heart Alliance, 81377 Munich, Germany
*
Authors to whom correspondence should be addressed.
J. Clin. Med. 2025, 14(4), 1045; https://doi.org/10.3390/jcm14041045
Submission received: 16 December 2024 / Revised: 20 January 2025 / Accepted: 4 February 2025 / Published: 7 February 2025

Abstract

:
Objectives: Stroke after transcatheter aortic valve replacement (TAVR) continues to be one of the most concerning complications. Anatomical variations of the aortic arch may increase the risk of embolic debris entering the brain during transfemoral catheter manipulation. We aimed to analyze the influence of aortic arch morphology on the occurrence of ischemic stroke during TAVR. Methods: We performed a retrospective, 1:2 propensity-matched case–control study to compare patients with and without periprocedural stroke (defined according to the Valve Academic Research Consortium III endpoints) after transfemoral TAVR between June 2007 and September 2022. Multi-slice computed tomography (MSCT) analysis of pre-TAVR aortograms was performed to investigate arch anatomy, configuration, curvature, and the take-off angles of the epi-aortic vessels. Results: A total of 2371 patients were enrolled in this study. Periprocedural ischemic stroke was observed in 67 patients. After propensity score matching, this study included 201 patients: 67 (case) vs. 134 (control). The mean age was 80.0 ± 13.2 and 81.6 ± 6.4 years (p = 0.5), and the mean Euroscore II was 4.1 ± 3.6 and 4.3 ± 41 (p = 0.7). There was no difference in arch anatomy (p = 0.2) and configuration (p = 0.8) between the groups. Arch curvature (p = 0.9) and angulation of the brachiocephalic (p = 0.3) and left common carotid artery (p = 0.058) also did not differ significantly between the case and control groups. Conclusions: MSCT analysis in this propensity score-matched study found no correlation between aortic arch geometry and TAVR-associated stroke.

1. Introduction

Periprocedural stroke after transcatheter aortic valve replacement (TAVR) occurs in up to 2.3–4.3% [1,2,3] of patients and continues to be one of the most devastating complications. Cerebral emboli are the primary cause of most TAVR-associated intraprocedural strokes [4]. Transfemoral access requires retrograde insertion of large devices and accessory guidewires, which mechanically interact with the aortic arch vessel wall, potentially provoking intraprocedural dislodgment of debris [5,6,7]. Catheter navigation in special geometrical variations such as a steep configuration of the aortic arch might increase the contact forces with the aortic vessel wall [8], potentially increasing the risk of cerebral embolization, as previously described in thoracic endovascular aortic repair studies [9,10]. Another important issue, potentially influencing embolic stroke manifestation during THV steering and positioning, might be the anatomical orientation of the epi-aortic vessels originating from the arch. Fluid dynamic simulations in aortic arch models have indeed found that atypical configurations of the epi-aortic arteries, such as the bovine arch anomaly, might play a substantial role in embolus transport and stroke propensity [11,12,13]. However, studies investigating TAVR-associated strokes in relation to aortic arch geometry are missing. Currently, the prevention of periprocedural stroke has especially become an important therapeutic goal with the development of dedicated cerebral embolic protection devices [14,15,16]. Should evidence confirm that aortic arch morphology influences the incidence of embolic stroke, the targeted use of cerebral embolic protection devices might be warranted in this specific subset of TAVR patients. Thus, we aimed to evaluate the influence of aortic arch anatomy on the occurrence of ischemic stroke during TAVR using multi-slice computed tomography (MSCT) analysis in a propensity score matched case–control study.

2. Materials and Methods

2.1. Patients

We conducted a retrospective, propensity score matched, case–control analysis of all patients who received a TAVR procedure at the Department of Cardiovascular Surgery at the German Heart Center Munich between June 2007 and September 2022. Patients with non-femoral TAVR access, conversion to surgical aortic valve replacement, usage of a cerebral embolic protection device, significant carotid stenosis (>70%), and missing data points were excluded from this study. The case group included all patients with a TAVR-associated periprocedural (≤30 days) overt ischemic stroke fulfilling the Neurologic Academic Research Consortium Type I (NeuroARC) [17] criteria based on the Valve Academic Research Consortium (VARC-III) endpoint definitions [18]. Patients with missing neuroimaging datasets, onset of neurological signs without neuroimaging evidence of central nervous system (CNS) infarction, need for intraoperative resuscitation, and other not ischemic related periprocedural causes of stroke (procedure-related intraoperative aortic dissection, hemorrhagic stroke, covert CNS infarction) were further excluded from the case group. After identifying the case group, a 1:2 propensity matching was conducted to find patients with similar clinical and epidemiological characteristics among those who underwent TAVR without experiencing periprocedural neurological events (≤30 days). These patients served as the control group. This study adhered to the Declaration of Helsinki and received approval from the local ethics committee of the Technical University of Munich (approval reference number: 2023-56-S-NP).

2.2. Stroke Definition

All strokes included in this study trial met the NeuroARC Type I criteria (Valve Academic Research Consortium III) for ischemic, symptomatic, periprocedural stroke [18]. A symptomatic ischemic stroke, as defined by the Valve Academic Research Consortium (VARC-III) endpoint definitions, was characterized by the acute onset of focal neurological symptoms, accompanied by neuroimaging evidence of central nervous system infarction in the relevant brain territory [18]. All neuroimaging reports, including brain computer tomography scans and brain magnetic resonance imaging, were reviewed and compared with the corresponding clinical data. Periprocedural stroke was defined as a symptomatic, ischemic stroke that occurred either during the index hospitalization or within 30 days following TAVR [18].

2.3. Aortic Arch MSCT Measurements and Definitions

All MSCT scans made as part of the preoperative TAVR planning were analyzed using the automated software program 3mensioTM Structural Heart (version 10.2, Pie Medical Imaging, Maastricht, The Netherlands). A comprehensive description of the imaging analysis protocol for the respective CT measurements has been published previously by the authors [19,20,21]. The following imaging parameters were defined prior to evaluation and subsequently analyzed by two independent cardiac surgeons with experience in cardiovascular imaging.
1.
Anatomical variations of the aortic arch
  • Normal aortic arch with a separated origin of the brachiocephalic, left common carotid, and left subclavian artery.
  • Bovine arch Type I presenting with a common origin for the brachiocephalic and left common carotid artery.
  • Bovine arch Type II with a separate origin of the left common carotid artery from the brachiocephalic artery.
2.
Configuration of the aortic arch according to the origin of the supra-aortic arteries
  • Aortic arch Type I with all supra-aortic branches originating at the level of the outer aortic curvature.
  • Aortic arch Type II with at least one of the supra-aortic branches originating between the level of the outer and inner aortic curvature.
  • Aortic arch Type III with at least one of the supra-aortic branches originating under the level of the inner aortic curvature (Figure 1) [21,22].
3.
Aortic arch curvature
Assessment of aortic arch curvature included the calculation of the maximal aortic arch angulation (AAA) as well as the determination of the aortic arch tortuosity index (TI) following the description by Boufi et al. [6]. For evaluating the AAA, reference points along the aortic centerline at the pulmonary trunk bifurcation and the fourth thoracic vertebra were used. The angle between perpendicular planes at these points defined the aortic arch angulation (Figure 2A,B). The aortic arch TI was calculated as follows: [(center-line distance)/(straight-line distance) − 1] × 100 [6,19]. The centerline distance was defined as the true length along the 3D centerline between the previously selected landmarks, whereas the straight-line distance represents the linear distance between these two points (Figure 2C,D).
4.
Aortic arch take-off angles
The following angles, as described previously by the authors, were assessed [19,22]:
  • AA/BA angle = angle between the aortic arch and the brachiocephalic artery.
  • AA/LCC angle = angle between the aortic arch and the left common carotid artery.

2.4. Clinical Data Collection

Baseline demographics, procedural characteristics, and postoperative data were prospectively recorded in our dedicated TAVR database and updated to the latest VARC-III recommendations [18].

2.5. Statistical Analysis

After checking for normal distribution, data were provided as count, mean ± standard deviation, or median with interquartile range as appropriate. Groups were compared using unpaired t-test, Wilcox rank sum test, and Fisher’s exact test as appropriate. The matching was performed using a combination of exact matching (valve type) and propensity score matching (including age, gender, history of atrial fibrillation, Euroscore II, preoperative stroke, and previous operation). A logistic regression model was used to calculate the propensity score, and the nearest neighbor matching protocol was employed for the matching process. To ensure data completeness for matching, the number of variables was limited to only those deemed clinically relevant. The level of inter-observer and intra-observer consensus for all study-specific aortic arch imaging measurements was tested by calculating the inter- and intra-class correlation coefficient (ICC), as previously described [19,21,23]. ICC values were categorized as follows:
-
≤0.5: poor reliability;
-
0.5–0.75: moderate reliability;
-
0.75–0.9: good reliability;
-
≥0.9: excellent reliability.
A p-value of less than 0.05 was considered statistically significant. Statistical analyses were performed by using the R environment version 4.2.1 [24] and BM SPSS Statistics 22.0 software (IBM Corp, Armonk, NY USA).

3. Results

3.1. Patients and Matching Results

The study flow chart is displayed in Figure 3. Of 4054 patients undergoing TAVR at our institution, 2371 qualified for the study based on the inclusion/exclusion criteria. Of those, 98 patients (4.1%) had a periprocedural cerebrovascular event (≤30 days); 67 of those met the criteria for inclusion into the case group.
The 1:2 matching resulted in a control group of 134 patients without periprocedural cerebrovascular events. The distribution of the variables included in the matching is shown in Table 1. Prior to matching, there was a significant difference in the valve type used between the case and the control groups. Most notably, there was a higher rate of first-generation self-expanding valves in the case group (28% vs. 10%), whereas the rate of balloon-expandable valves was higher in the control group. Furthermore, patients without periprocedural stroke had a slightly higher Euroscore II (5.0 ± 6.2 vs. 4.1 ± 3.6) and a higher rate of previous cardiac operations (14.2% vs. 6.0%). After applying the matching procedure, the 134 matched patients, who represent the control group, showed perfect agreement concerning the implanted valve type and were similar in terms of the remaining variables used for matching (Table 1).

3.2. Baseline and Perioperative Patient Characteristics

Baseline characteristics not included in the matching protocol were comparable between the case and the control group (Table 2): median age was 83 years [IQR 65–93] and 82 years [IQR 53–94] (p = 0.7), and the previous stroke rate was 13.4% and 10.4% (p = 0.6) in the case and control group, respectively. The rate of balloon-expandable valves was 34.3% in both groups, with almost identical rates of pre- (59.7% vs. 58.2%, p = 0.9) and post-dilatation (32.8% vs. 33.6%, p = 1.0).

3.3. MSCT Measurements

Retrospective aortic arch morphology MSCT evaluation was performed in all patients (Table 3). The measurements showed good to excellent reliability in terms of inter- and intra-observer differences (Tables S1 and S2, Supplementary Materials). There was no difference regarding the anatomy of the aortic arch (p = 0.2) with a standard aortic arch anatomy being the predominant morphology in both groups (case group: 74%, control group: 66.4%). Bovine arch anatomy was found in 25.3% of patients with stroke and in 33.5% of patients without. Aortic arch configuration did not differ either among groups (p = 0.8) (Table 3). A Type II configurated aortic arch was the most common pattern with 71.6% in both groups (p = 0.8). There was also no difference in aortic arch angulation (p = 0.9) and tortuosity index (p = 0.3) (Table 3) (Figure 4). The determination of the AO/BA angle was also similar in both groups (median 111° vs. 107°, p = 0.3), as well as the AO/CCA angle (121° vs. 125°, p = 0.058) (Figure 4).

4. Discussion

Despite advances in technology and expertise, which have lowered the incidence of stroke post-TAVR over time, this complication remains a serious event that significantly affects both survival and quality of life [1]. Recent research has focused on the detection of risk factors for periprocedural stroke, including patient characteristics and procedural factors such as THV selection, access route, and aortic valve anatomy. However, the anatomical morphology of the aortic arch as a predictor for TAVR-associated stroke has not yet been systematically investigated. This study is the first of its kind to analyze how aortic arch anatomy, configuration, angulation, and the take-off angles of the epi-aortic arteries impact TAVR-associated stroke in a propensity-matched case–control study. However, imaging examinations in our patients showed no association between TAVR-associated stroke and aortic arch morphology.
We initially hypothesized that the presence of a bovine arch anatomy might serve as a predictive feature for embolic stroke in TAVR patients. This atypical supra-aortic branching pattern, occurring in up to 31% of individuals [21,25], constitutes the most common anatomical arch variation and has been linked to a higher stroke incidence in the general population [13,26,27]. Previous biomechanical studies indicated that such atypical branching patterns of the supra-aortic vessels may impact flow hemodynamics and embolus transport [11,12,13]. The shared origin of the brachiocephalic and the left common carotid arteries also creates a wider, single pathway for potential embolic debris, which might increase the stroke risk in patients with this anatomical variation [28]. However, our propensity-matched case–control study could not confirm this clinically. The frequency of bovine arch anatomy was 25.4% versus 33.5% among TAVR patients with and without a periprocedural stroke, respectively (p = 0.2).
Besides our investigation, there is only one recently published registry study by Russo et al., which also addresses the scarcely explored topic of aortic arch morphology in relation to stroke rates in the TAVR population [28]. However, Russo and colleagues present divergent study findings and report that a bovine arch is associated with a twofold increase in TAVR-associated stroke among TAVI patients with a bovine arch (n = 495) compared to patients with a non-bovine anatomy (n = 2280) [28]. There are several reasons why the results of Russo and colleagues could not be reproduced in our study. First, Russo et al. did not limit their cohort to patients with transfemoral access and did not exclude patients requiring conversion to SAVR or other TAVR-related complications such as aortic dissection. Second, Russo`s study also included patients with hemorrhagic infarctions as well as those with neurological symptoms without neuroimaging evidence of central nervous system infarction. In contrast, this patient population was intentionally excluded from our analysis. Our aim was to focus on a more specific patient cohort presenting with symptomatic, ischemic stroke to ensure the precision of our findings. Third, the method of correction for possible confounders was chosen differently in the two studies. While Russo et al. used a multivariate regression model to calculate the isolated effect of the bovine arch anatomy, we performed propensity score matching. Due to the study design, Russo and colleagues analyzed a significantly larger population. Nevertheless, the reliability of the two statistics largely depends on the number of patients with periprocedural stroke, which was similar in both studies. Fourth, an important confounder might be the usage of different transcatheter heart valve systems, as distinct implantation techniques might be linked to varying incidences of periprocedural stroke rates [14,29]. The analysis of our unmatched cohorts revealed a significant difference in valve types between the stroke and control groups (p = < 0.001), which was balanced after matching (p = 1.0). Russo et al. did not correct for valve type in their logistic regression model [28]. Furthermore, the study investigators did not provide a clear description of their CT evaluation protocol. In contrast, the MSCT evaluation in our study follows a comprehensive and highly standardized protocol, detailing each individual measurement and specifying the exact software used.
Besides bovine arch anatomy, we assumed that aortic arch steepness and the corresponding take-off angles of the supra-aortic arteries might be further potential determinants for procedure-related strokes. In our study, arch steepness was assessed by the evaluation of aortic arch configuration type and the measurement of arch curvature. Unlike bovine arch anatomy, there are currently no data concerning the distribution of arch steepness in general and TAVR populations and its potential influence on stroke rates. Navigating the THV catheter in a steeply configured arch might increase the contact forces on the vessel wall, potentially resulting in a higher risk of cerebral embolization [8]. Neurointerventional studies have found that a Type III arch could be associated with prolonged catheter manipulation time and therefore increased periprocedural risk [30]. In our study cohort, the Type II arch emerged as the most common configuration, with similar arch angulations and take-off angles of the supra-aortic arteries in both groups. Thus, arch steepness and supra-aortic take-off angles could also not be identified as predictors for periprocedural stroke.
Although our investigation did not demonstrate any significant impact of aortic arch anatomy on the incidence of TAVR-associated stroke, important clinical insights can still be drawn. Based on our findings, we do not consider it necessary to use additional cerebral embolic protection systems in patients with atypical aortic arch morphologies, such as a bovine arch configuration. This conclusion is particularly relevant given that current cerebral protection devices have not shown benefits regarding hard clinical endpoints [31]. Additionally, studies showed that the usage of dual-filter-based cerebral embolic protection devices in TAVR patients presenting with bovine arch anomalies has been associated with higher rates of device implantation failure, owing to the more complex navigation maneuvers required [19,32]. According to our MSCT-based propensity-matched analysis, we would not take any special precautions in this patient population.
Our study presents findings from a retrospective, single-center investigation focusing on the correlation between stroke incidence and aortic arch morphology in TAVR patients. Therefore, stroke severity was not evaluated. Although we performed propensity score matching to minimize confounders while isolating the effect of aortic arch morphology, procedural factors may still be confounded by advancements in technique, operator experience, and patient selection over time. Additionally, factors such as the amount of aortic calcification and periprocedural data, including the use of specific medications, may have influenced the outcomes.

5. Conclusions

MSCT analysis in this propensity-matched case–control study found no association between aortic arch morphology and TAVR-associated stroke. Therefore, it is not possible to elaborate on the risk of periprocedural stroke solely based on the morphology of the aortic arch.

Supplementary Materials

The following supporting information can be downloaded at: https://www.mdpi.com/article/10.3390/jcm14041045/s1. Table S1: Intraobserver agreement for 3-dimensional multislice computed tomography measurements, Table S2: Interobserver agreement for 3-dimensional multislice computed tomography measurements.

Author Contributions

Conceptualization, S.V.; data curation, K.R. and M.B.; formal analysis, S.V. and M.B.; investigation, S.V. and K.R.; methodology, S.V. and K.R.; project administration, S.V.; software, S.V., K.R. and M.B.; supervision, S.V. and M.K.; validation, S.V., K.R. and M.B.; visualization, S.V. and T.G.; writing—original draft, S.V., K.R. and M.B.; writing—review and editing, C.C., T.G., K.V., H.R., A.A., K.S. and M.K. All authors have read and agreed to the published version of the manuscript.

Funding

This research received no external funding.

Institutional Review Board Statement

This study adhered to the Declaration of Helsinki and received approval from the local ethics committee of the Technical University of Munich (approval reference number: 2023-56-S-NP, date of approval: 31 January 2023).

Informed Consent Statement

Patients confirmed anonymous data collection.

Data Availability Statement

All relevant data generated or analyzed during this study are included in this published article.

Conflicts of Interest

Ruge serves as a physician proctor for Abbott and Edwards Lifescience, is a consultant for Medtronic, Abbott, and Edwards Lifescience, and is a member of the Abbott advisory board. Krane is a physician proctor and a member of the medical advisory board for Sanamedi, a physician proctor for Peter Duschek, a medical consultant for EVOTEC and Moderna, and has received speakers’ honoraria from EDWARDS, AtriCure, Medtronic, and Terumo. Vitanova is a consultant for Medtronic and AstraZeneca and has received speakers’ honoraria from Edwards and AtruCure. Amabile is a consultant for Sanamedi, Inc.

Abbreviations:

AAAAortic arch angulation
AA/BAAngle aortic arch/brachiocephalic artery angle
AA/LCCAAngle aortic arch/left common carotid artery angle
AFAtrial fibrillation
CNSCentral nervous system
LVEFLeft ventricular ejection fraction
ICCIntra-class correlation coefficient
MSCT Multi-slice computed tomography
VARC IIIValve Academic Research Consortium III
TAVRTranscatheter aortic valve replacement
THVTranscatheter heart valve
TITortuosity index

References

  1. Levi, A.; Linder, M.; Seiffert, M.; Witberg, G.; Pilgrim, T.; Tomii, D.; Talmor-Barkan, Y.; Van Mieghem, N.M.; Adrichem, R.; Codner, P.; et al. Management and Outcome of Acute Ischemic Stroke Complicating Transcatheter Aortic Valve Replacement. JACC Cardiovasc. Interv. 2022, 15, 1808–1819. [Google Scholar] [CrossRef] [PubMed]
  2. Huded, C.P.; Tuzcu, E.M.; Krishnaswamy, A.; Mick, S.L.; Kleiman, N.S.; Svensson, L.G.; Carroll, J.; Thourani, V.H.; Kirtane, A.J.; Manandhar, P.; et al. Association Between Transcatheter Aortic Valve Replacement and Early Postprocedural Stroke. JAMA 2019, 321, 2306–2315. [Google Scholar] [CrossRef] [PubMed]
  3. Muralidharan, A.; Thiagarajan, K.; Van Ham, R.; Gleason, T.G.; Mulukutla, S.; Schindler, J.T.; Jeevanantham, V.; Thirumala, P.D. Meta-Analysis of Perioperative Stroke and Mortality in Transcatheter Aortic Valve Implantation. Am. J. Cardiol. 2016, 118, 1031–1045. [Google Scholar] [CrossRef] [PubMed]
  4. Van Gils, L.; Kroon, H.; Daemen, J.; Ren, C.; Maugenest, A.M.; Schipper, M.; De Jaegere, P.P.; Van Mieghem, N.M. Complete filter-based cerebral embolic protection with transcatheter aortic valve replacement. Catheter. Cardiovasc. Interv. Off. J. Soc. Card. Angiogr. Interv. 2018, 91, 790–797. [Google Scholar] [CrossRef] [PubMed]
  5. Kahlert, P.; Al-Rashid, F.; Dottger, P.; Mori, K.; Plicht, B.; Wendt, D.; Bergmann, L.; Kottenberg, E.; Schlamann, M.; Mummel, P.; et al. Cerebral embolization during transcatheter aortic valve implantation: A transcranial Doppler study. Circulation 2012, 126, 1245–1255. [Google Scholar] [CrossRef]
  6. Boufi, M.; Guivier-Curien, C.; Loundou, A.D.; Deplano, V.; Boiron, O.; Chaumoitre, K.; Gariboldi, V.; Alimi, Y.S. Morphological Analysis of Healthy Aortic Arch. Eur. J. Vasc. Endovasc. Surg. Off. J. Eur. Soc. Vasc. Surg. 2017, 53, 663–670. [Google Scholar] [CrossRef] [PubMed]
  7. Ignatius, A.; Eng, M.H.; Frisoli, T.M. Neurologic Complications in Transcatheter Aortic Valve Replacement. Interv. Cardiol. Clin. 2021, 10, 519–529. [Google Scholar] [CrossRef]
  8. Rafii-Tari, H.; Riga, C.V.; Payne, C.J.; Hamady, M.S.; Cheshire, N.J.; Bicknell, C.D.; Yang, G.Z. Reducing contact forces in the arch and supra-aortic vessels using the Magellan robot. J. Vasc. Surg. 2016, 64, 1422–1432. [Google Scholar] [CrossRef] [PubMed]
  9. Geisbusch, P.; Kotelis, D.; Muller-Eschner, M.; Hyhlik-Durr, A.; Bockler, D. Complications after aortic arch hybrid repair. J. Vasc. Surg. 2011, 53, 935–941. [Google Scholar] [CrossRef]
  10. Kotelis, D.; Bischoff, M.S.; Jobst, B.; von Tengg-Kobligk, H.; Hinz, U.; Geisbusch, P.; Bockler, D. Morphological risk factors of stroke during thoracic endovascular aortic repair. Langenbecks Arch. Surg. 2012, 397, 1267–1273. [Google Scholar] [CrossRef]
  11. Elsaid, N.; Bigliardi, G.; Dell’Acqua, M.L.; Vandelli, L.; Ciolli, L.; Picchetto, L.; Borzi, G.; Ricceri, R.; Pentore, R.; Vallone, S.; et al. The Relation Between Aortic Arch Branching Types and the Laterality of Cardio-Embolic Stroke. J. Stroke Cerebrovasc. Dis. Off. J. Natl. Stroke Assoc. 2020, 29, 104917. [Google Scholar] [CrossRef] [PubMed]
  12. Choi, H.W.; Luo, T.; Navia, J.A.; Kassab, G.S. Role of Aortic Geometry on Stroke Propensity based on Simulations of Patient-Specific Models. Sci. Rep. 2017, 7, 7065. [Google Scholar] [CrossRef]
  13. Matakas, J.D.; Gold, M.M.; Sterman, J.; Haramati, L.B.; Allen, M.T.; Labovitz, D.; Slasky, S.E. Bovine Arch and Stroke Laterality. J. Am. Heart Assoc. 2020, 9, e015390. [Google Scholar] [CrossRef]
  14. Kapadia, S.R.; Kodali, S.; Makkar, R.; Mehran, R.; Lazar, R.M.; Zivadinov, R.; Dwyer, M.G.; Jilaihawi, H.; Virmani, R.; Anwaruddin, S.; et al. Protection Against Cerebral Embolism During Transcatheter Aortic Valve Replacement. J. Am. Coll. Cardiol. 2017, 69, 367–377. [Google Scholar] [CrossRef] [PubMed]
  15. Lansky, A.J.; Schofer, J.; Tchetche, D.; Stella, P.; Pietras, C.G.; Parise, H.; Abrams, K.; Forrest, J.K.; Cleman, M.; Reinohl, J.; et al. A prospective randomized evaluation of the TriGuard HDH embolic DEFLECTion device during transcatheter aortic valve implantation: Results from the DEFLECT III trial. Eur. Heart J. 2015, 36, 2070–2078. [Google Scholar] [CrossRef] [PubMed]
  16. Rodes-Cabau, J.; Dumont, E.; Boone, R.H.; Larose, E.; Bagur, R.; Gurvitch, R.; Bedard, F.; Doyle, D.; De Larochelliere, R.; Jayasuria, C.; et al. Cerebral embolism following transcatheter aortic valve implantation: Comparison of transfemoral and transapical approaches. J. Am. Coll. Cardiol. 2011, 57, 18–28. [Google Scholar] [CrossRef]
  17. Lansky, A.J.; Messe, S.R.; Brickman, A.M.; Dwyer, M.; van der Worp, H.B.; Lazar, R.M.; Pietras, C.G.; Abrams, K.J.; McFadden, E.; Petersen, N.H.; et al. Proposed Standardized Neurological Endpoints for Cardiovascular Clinical Trials: An Academic Research Consortium Initiative. J. Am. Coll. Cardiol. 2017, 69, 679–691. [Google Scholar] [CrossRef]
  18. Généreux, P.; Piazza, N.; Alu, M.C.; Nazif, T.; Hahn, R.T.; Pibarot, P.; Bax, J.J.; Leipsic, J.A.; Blanke, P.; Blackstone, E.H.; et al. Valve Academic Research Consortium 3: Updated endpoint definitions for aortic valve clinical research. Eur. Heart J. 2021, 42, 1825–1857. [Google Scholar] [CrossRef] [PubMed]
  19. Voss, S.; Campanella, C.; Burri, M.; Trenkwalder, T.; Sideris, K.; Erlebach, M.; Ruge, H.; Krane, M.; Vitanova, K.; Lange, R. Anatomical reasons for failure of dual-filter cerebral embolic protection application in TAVR: A CT-based analysis. J. Card. Surg. 2021, 36, 4537–4545. [Google Scholar] [CrossRef] [PubMed]
  20. Voss, S.; Schechtl, J.; Nobauer, C.; Bleiziffer, S.; Lange, R. Patient eligibility for application of a two-filter cerebral embolic protection device during transcatheter aortic valve implantation: Does one size fit all? Interact. Cardiovasc. Thorac. Surg. 2020, 30, 605–612. [Google Scholar] [CrossRef]
  21. Campanella, C.; Vitanova, K.; Burri, M.; Ruge, H.; Lange, R.; Voss, S. Does Aortic Arch Anatomy Affect Stroke Laterality in Transcatheter Aortic Valve Implantation? J. Card. Surg. 2023, 2023, 5563121. [Google Scholar] [CrossRef]
  22. Muller, M.D.; Ahlhelm, F.J.; von Hessling, A.; Doig, D.; Nederkoorn, P.J.; Macdonald, S.; Lyrer, P.A.; van der Lugt, A.; Hendrikse, J.; Stippich, C.; et al. Vascular Anatomy Predicts the Risk of Cerebral Ischemia in Patients Randomized to Carotid Stenting Versus Endarterectomy. Stroke A J. Cereb. Circ. 2017, 48, 1285–1292. [Google Scholar] [CrossRef]
  23. Koo, T.K.; Li, M.Y. A Guideline of Selecting and Reporting Intraclass Correlation Coefficients for Reliability Research. J. Chiropr. Med. 2016, 15, 155–163. [Google Scholar] [CrossRef]
  24. R Core Team. R: A Language and Environment for Statistical Computing; R Foundation: Vienna, Austria, 2014. [Google Scholar]
  25. Moorehead, P.A.; Kim, A.H.; Miller, C.P.; Kashyap, T.V.; Kendrick, D.E.; Kashyap, V.S. Prevalence of Bovine Aortic Arch Configuration in Adult Patients with and without Thoracic Aortic Pathology. Ann. Vasc. Surg. 2016, 30, 132–137. [Google Scholar] [CrossRef] [PubMed]
  26. Syperek, A.; Angermaier, A.; Kromrey, M.L.; Hosten, N.; Kirsch, M. The so-called “bovine aortic arch”: A possible biomarker for embolic strokes? Neuroradiology 2019, 61, 1165–1172. [Google Scholar] [CrossRef] [PubMed]
  27. Samadhiya, S.; Sardana, V.; Bhushan, B.; Maheshwari, D.; Yadav, S.R.; Goyal, R. Propensity of Stroke in Standard versus Various Aortic Arch Variants: A 200 Patients Study. Ann. Indian Acad. Neurol. 2022, 25, 634–639. [Google Scholar] [CrossRef]
  28. Lo Russo, G.V.; Alarouri, H.S.; Al-Abcha, A.; Vogl, B.; Mahayni, A.; Sularz, A.; Hatoum, H.; Collins, J.; Crestanello, J.A.; Alkhouli, M. Association of Bovine Arch Anatomy With Incident Stroke After Transcatheter Aortic Valve Replacement. J. Am. Heart Assoc. 2024, 13, e032963. [Google Scholar] [CrossRef] [PubMed]
  29. Grabert, S.; Lange, R.; Bleiziffer, S. Incidence and causes of silent and symptomatic stroke following surgical and transcatheter aortic valve replacement: A comprehensive review. Interact. Cardiovasc. Thorac. Surg. 2016, 23, 469–476. [Google Scholar] [CrossRef] [PubMed]
  30. Lahlouh, M.; Chenoune, Y.; Blanc, R.; Piotin, M.; Escalard, S.; Fahed, R.; Szewczyk, J.; Passat, N. Automated Aortic Anatomy Analysis: From Image to Clinical Indicators. Annu. Int. Conf. IEEE Eng. Med. Biol. Soc. 2023, 2023, 1–5. [Google Scholar] [CrossRef] [PubMed]
  31. Kaur, A.; Dhaliwal, A.S.; Sohal, S.; Gwon, Y.; Gupta, S.; Bhatia, K.; Dominguez, A.C.; Basman, C.; Tamis-Holland, J. Role of Cerebral Embolic Protection Devices in Patients Undergoing Transcatheter Aortic Valve Replacement: An Updated Meta-Analysis. J. Am. Heart Assoc. 2024, 13, e030587. [Google Scholar] [CrossRef]
  32. Tagliari, A.P.; Ferrari, E.; Haager, P.K.; Schmiady, M.O.; Vicentini, L.; Gavazzoni, M.; Gennari, M.; Jorg, L.; Khattab, A.A.; Blochlinger, S.; et al. Feasibility and Safety of Cerebral Embolic Protection Device Insertion in Bovine Aortic Arch Anatomy. J. Clin. Med. 2020, 9, 118. [Google Scholar] [CrossRef]
Figure 1. Calculation of aortic arch configuration type based on the origin of the supra-aortic arteries (A). Three-dimensional MSCT reconstruction of a Type III steep aortic arch (B).
Figure 1. Calculation of aortic arch configuration type based on the origin of the supra-aortic arteries (A). Three-dimensional MSCT reconstruction of a Type III steep aortic arch (B).
Jcm 14 01045 g001
Figure 2. Assessment of aortic arch curvature. Schematic illustration of calculating the maximum aortic arch angulation (A) and aortic arch tortuosity index (C) relative to predefined landmarks (L1 = reference point at the level of the bifurcation of the pulmonary trunk; L2 = reference point at the level of the fourth thoracic vertebra body upper edge). MSCT-based measurements of the corresponding values (B,D).
Figure 2. Assessment of aortic arch curvature. Schematic illustration of calculating the maximum aortic arch angulation (A) and aortic arch tortuosity index (C) relative to predefined landmarks (L1 = reference point at the level of the bifurcation of the pulmonary trunk; L2 = reference point at the level of the fourth thoracic vertebra body upper edge). MSCT-based measurements of the corresponding values (B,D).
Jcm 14 01045 g002
Figure 3. Flow diagram of study population.
Figure 3. Flow diagram of study population.
Jcm 14 01045 g003
Figure 4. Boxplots illustrating MSCT measurements in the case and control groups.
Figure 4. Boxplots illustrating MSCT measurements in the case and control groups.
Jcm 14 01045 g004
Table 1. Balancing of matched variables before and after matching.
Table 1. Balancing of matched variables before and after matching.
PrematchPostmatch
CaseControlSMDp-ValueCaseControlSMDp-Value
n = 67n = 2273 n = 67n = 134
Female gender35 (52.2%)1089 (47.9%)0.0870.535 (52.2%)70 (52.2%)01.0
Atrial fibrilation16 (23.9%)640 (28.2%)0.0950.516 (23.9%)26 (19.4%)0.110.5
Preoperative stroke9 (13.4%)241 (10.6%)0.0920.49 (13.4%)14 (10.4%)0.0940.6
Previous operation4 (6.0%)323 (14.2%)0.2380.074 (6.0%)8 (6.0%)01.0
Age (Y)80.0 ± 13.279.7 ± 8.90.0420.880.0 ± 13.281.2 ± 6.40.1280.5
Euroscore 24.1 ± 3.65.0 ± 6.20.1450.0584.1 ± 3.64.3 ± 4.10.0550.7
Valve type <0.001 1.0
Medtronic CoreValve (Metdronic, Minneapolis, MN, USA)19 (28.4%)229 (10.1%) 19 (28.4%)38 (28.4%)
Medtronic Evolut R (Metdronic, Minneapolis, MN, USA)14 (20.9%)561 (24.7%) 14 (20.9%)28 (20.9%)
Edwards Sapien Ultra (Edwards Lifesciences, Irvine, CA, USA)12 (17.9%)527 (23.2%) 12 (17.9%)24 (17.9%)
Edwards Sapien 3 (Edwards Lifesciences, Irvine, CA, USA)10 (14.9%)523 (23.0%) 10 (14.9%)20 (14.9%)
Medtronic Evolut Pro (Metdronic, Minneapolis, MN, USA)5 (7.5%)90 (4.0%) 5 (7.5%)10 (7.5%)
Boston Scientific Lotus (Boston Scientific, Watertown, MA, USA)4 (6.0%)134 (5.9%) 4 (6.0%)8 (6.0%)
Symetis Acurate Neo (Boston Scientific, Watertown, MA, USA)2 (3.0%)80 (3.5%) 2 (3.0%)4 (3.0%)
Edwards Sapien XT (Edwards Lifesciences, Irvine, CA, USA)1 (1.5%)24 (1.1%) 1 (1.5%)2 (1.5%)
Other0 (0.0%)105 (4.6%) 0 (0.0%)0 (0.0%)
Notes: Groups were compared using Fisher’s exact test, chi-square, or t-test. SMD: standardized mean difference.
Table 2. Baseline and perioperative patient characteristics.
Table 2. Baseline and perioperative patient characteristics.
CharacteristicsCaseControlp-Value
n67134
Age (y)83 [65–93]82 [53–94]0.7
Female gender (n)35 (52.2%)70 (52.2%)1.0
Body mass index (kg/m2)25.7 [16.5–46.8]27.0 [3.3–45.7]0.09
Coronary artery disease (n)37 (55.2%)70 (52.2%)0.8
Hypertension (n)59 (88.1%)123 (91.8%)0.4
Diabetes (n)18 (26.9%)43 (32.1%)0.5
Peripheral artery disease (n)11 (16.4%)17 (12.7%)0.5
Previous cardiac procedure (n)4 (6.0%)8 (6.0%)1.0
Previous stroke (n)9 (13.4%)14 (10.4%)0.6
COPD (n)11 (16.4%)13 (9.7%)0.2
LV-EF (n) 0.3
>50%49 (73.1%)88 (65.7%)
35–50%13 (19.4%)34 (25.4%)
<35%5 (7.5%)11 (8.2%)
GFR (MDR) (n)58 ± 2065 ± 240.059
STS Score4.1 ± 3.04.2 ± 3.30.8
Euroscore II4.1 ± 3.64.3 ± 4.10.7
Year of procedure (n) 0.4
2007–201212 (17.9%)16 (11.9%)
2012–201724 (35.8%)47 (35.1%)
2017–202331 (46.3%)71 (53.0%)
Ballon-expandable valve (n)23 (34.3%)46 (34.3%)1.0
Second valve implantation (n)2 (3.0%)1 (0.7%)0.3
Puncture to suture (min)73 ± 3866 ± 390.2
Pre-dilatation (n)40 (59.7%)78 (58.2%)0.9
Post-dillatation (n)22 (32.8%)45 (33.6%)1.0
GFR: glomerular filtration rate.
Table 3. MSCT measurements.
Table 3. MSCT measurements.
MSCT DataCaseControlp-Value
n67134
Anatomy 0.2
Normal50 (74.6%)89 (66.4%)
Bovine I7 (10.4%)27 (20.1%)
Bovine II10 (14.9%)18 (13.4%)
Configuration 0.8
Type I9 (13.4%)15 (11.2%)
Type II48 (71.6%)96 (71.6%)
Type III10 (14.9%)23 (17.2%)
AO/BA Angle (degree)110 [60–141]107 [52–138]0.3
AO/CCA Angle (degree)121 [93–162]125 [96–168]0.058
Arch Angulation (degree)108 [49–137]107 [86–153]0.9
Tortuosity Index17.5 [3.3–37.4]18.1 [9.2–57.5]0.3
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Share and Cite

MDPI and ACS Style

Voss, S.; Rusa, K.; Campanella, C.; Georgescu, T.; Vitanova, K.; Ruge, H.; Amabile, A.; Sideris, K.; Krane, M.; Burri, M. The Impact of Aortic Arch Morphology on Periprocedural Stroke in Transcatheter Aortic Valve Replacement. J. Clin. Med. 2025, 14, 1045. https://doi.org/10.3390/jcm14041045

AMA Style

Voss S, Rusa K, Campanella C, Georgescu T, Vitanova K, Ruge H, Amabile A, Sideris K, Krane M, Burri M. The Impact of Aortic Arch Morphology on Periprocedural Stroke in Transcatheter Aortic Valve Replacement. Journal of Clinical Medicine. 2025; 14(4):1045. https://doi.org/10.3390/jcm14041045

Chicago/Turabian Style

Voss, Stephanie, Katerina Rusa, Caterina Campanella, Teodora Georgescu, Keti Vitanova, Hendrik Ruge, Andrea Amabile, Konstantinos Sideris, Markus Krane, and Melchior Burri. 2025. "The Impact of Aortic Arch Morphology on Periprocedural Stroke in Transcatheter Aortic Valve Replacement" Journal of Clinical Medicine 14, no. 4: 1045. https://doi.org/10.3390/jcm14041045

APA Style

Voss, S., Rusa, K., Campanella, C., Georgescu, T., Vitanova, K., Ruge, H., Amabile, A., Sideris, K., Krane, M., & Burri, M. (2025). The Impact of Aortic Arch Morphology on Periprocedural Stroke in Transcatheter Aortic Valve Replacement. Journal of Clinical Medicine, 14(4), 1045. https://doi.org/10.3390/jcm14041045

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop