1. Introduction
Short-stem total hip arthroplasty (THA) has become an integral component of contemporary management for hip arthritis over the past two decades. These implants have demonstrated favorable medium-term clinical outcomes and consistently low revision rates across a variety of designs [
1,
2,
3]. With the increasing global volume of THA procedures, particularly among younger and more active patients, short-stem implants are increasingly preferred in this demographic due to their potential to preserve bone stock and soft tissue [
4,
5].
The heterogeneity of short-stem designs has posed challenges in developing a standardized classification system. The Joint Implant Surgery and Research Foundation (JISRF) has developed a widely accepted system based on the region of primary stability of short-stem implants. This classification categorizes stems into three primary groups: head-stabilized (Class 1), neck-stabilized (Class 2), and metaphyseal-stabilized (Class 3), with further subclassifications reflecting variations in design and surgical technique [
6].
Multiple studies have reported on the capacity of short stems to achieve more natural load distribution in the proximal femur, potentially reducing stress shielding and promoting adaptive bone remodeling [
7,
8,
9,
10,
11]. There, however, remains no consensus regarding the biomechanical differences between stem classes or the relative superiority of any class in facilitating physiological load-bearing.
Although prior studies have employed dual-energy X-ray absorptiometry (DEXA) to evaluate changes in bone mineral density (BMD) around short-stem implants [
8,
12,
13], no studies to date have sought to correlate these density changes in individual patients with computational biomechanical models of load transfer using 6-week postoperative radiographs. By integrating radiographic data with finite element analyses, this study seeks to advance understanding of the relationship between implant design, load transfer, and bone remodeling in short-stem THA.
This study hypothesizes that a biomechanical model can reliably predict the progression of proximal femoral remodeling based on early postoperative radiographs. To test this hypothesis, radiographic patterns of bone remodeling across different short-stem implant classes were compared and correlated with computational biomechanical models of load transfer.
The advantage of a biomechanical model is the possibility to perform variability analysis of implant positioning in an individual patient. It is further hypothesized that the variation in implant position is a decisive parameter in determining load transfer regardless of the geometry of the implant.
2. Materials and Methods
2.1. Study Design
This study evaluated bone remodeling associated with three distinct short-stem implant designs: Proxima (DePuy Synthes), Collo-MIS, and Minima (both by LimaCorporate). These stems were chosen to represent different classes of short-stem designs according to the JISRF classification. The Proxima stem (Class 2B) is a short lateral-engaging stem with a sintered microbead surface to maximize primary and secondary fixation. Although discontinued, the Proxima stem remains a unique representative of its class. The Collo-MIS stem (Class 2A) is a short curved, neck-sparing design with a hydroxyapatite coating on its proximal two-thirds for osseointegration while minimizing distal fixation by utilizing a polished tip. The Minima stem (Class 3A) is a triple-tapered, metaphyseally stabilized design with a porous titanium surface (200 µm pore size) in the metaphyseal region to promote bone ingrowth and a roughened distal surface that allows for bone ongrowth. For all implants, ceramic heads were used, with the Pinnacle acetabular cup used in combination with the Proxima stems and the Delta PF cup used with the Collo-MIS and Minima stems.
2.2. Patient Selection and Follow-Up
This retrospective, single-surgeon, consecutive case series conducted at a single tertiary center was approved by the institutional ethics board. The study included patients who underwent surgery utilizing the Proxima, Minima, and Collo-MIS short stems. Overall, there were 31 implanted hips of both the Minima (29 patients) and Collo-MIS (26 patients) stems and 13 hips of the Proxima stem (9 patients). The indication for THA was primary osteoarthritis in all patients. All patients were mobile before the surgery with varying levels of sports activity.
No patients experienced complications such as joint dislocation, periprosthetic joint infection, or periprosthetic fracture. Patients with major comorbidities based on the preoperative risk assessment based on the American Society of Anesthesiologists classification were excluded from the study. Any patients with previously diagnosed osteoporosis or clear signs of osteoporosis on radiographs were also excluded from this study. Inclusion criteria required clear radiographic evidence of remodeling indicative of biomechanical strain. Only patients with standardized radiographic and clinical follow-up evaluations at 6 weeks, 6 months, 1 year, and annually thereafter were included. The cohort sizes were normalized, with five patients allocated to each group.
After surgery, all patients offloaded with crutches for 6 weeks, where after a radiological and clinical follow-up, they were allowed to bear full weight. All patients were instructed on post-surgical activity, where they were advised to avoid high impact sports activities such as running, basketball, or football. Instead, low-impact sports activities were recommended.
Radiographic evaluations focused on changes indicative of stress shielding, cortical hypertrophy, or new trabecular formation. Bone remodeling patterns were analyzed in modified Gruen zones [
14] on radiographs taken at 6 weeks and 2 years postoperatively. Remodeling was categorized as bone resorption, bone apposition, or no activity. Demarcation of zones followed standardized anatomical landmarks, ensuring consistent assessment across implant designs.
2.3. Biomechanical Modeling
Finite element analysis (FEA) was employed to develop patient-specific planar biomechanical models from 6-week postoperative radiographs for each patient. The model differentiated between cortical bone, cancellous bone, and implant material, with material properties sourced from a study by R. Hambli [
15]. To simulate physiological loading conditions relevant to everyday activities, we applied a joint contact force equivalent to 2.38 times the patient’s body weight (BW). This loading magnitude corresponds to the peak hip joint force in an average adult patient typically observed during normal walking at speed about 4 km/h [
16]. The load was applied at the center of the femoral head, with the reaction force of the effective abductor muscles applied to the greater trochanter. Pauwel’s angle of the loading force [
17] was adjusted for each patient to account for anatomical variability.
Strain energy density (SED) was evaluated at the interface between implant and bone and used as an input for mechanostat-based remodeling predictions (Frost’s theory) [
18]. Specifically, SED divided by cancellous bone density stands for mechanical stimulus [
19].
The mechanobiological model employed in this study posits the existence of upper and lower thresholds of mechanical stimulus [
20]. The brute-force algorithm was used to find out the threshold value for apposition. The algorithm systematically tests all possible threshold values to find the one that maximizes classification accuracy. When the mechanical stimulus exceeds the upper threshold (12 J/kg), bone density increases through apposition. Conversely, if the stimulus falls below the lower threshold (2 J/kg) represented by the lower resorption occurrence IQR bound, bone resorption occurs. The range between these thresholds, referred to as the “lazy zone,” is characterized by negligible or minor remodeling activity. To align the biomechanical predictions with radiographic observations, each Gruen zone was categorized based on the predominant mechanical stimulus as indicative of bone apposition, bone resorption, or no activity. This approach allowed for a direct comparison between the computationally derived remodeling patterns and observed radiographic changes.
Using the mechanobiological model, we assessed how the position of the implant affects the bone remodeling in specific patients. For each of the three stems in a single patient, an implantation was numerically simulated with the stems in either varus, neutral, or valgus position. The valgus or varus position of the stem was determined by the surgeon based on radiographic positions for each stem observed in clinical practice.
2.4. Statistical Analysis
To evaluate the correlation between biomechanical predictions and observed remodeling patterns, a Mann–Whitney–Wilcoxon test was applied. Predicted remodeling patterns in the Gruen zones were compared to radiographic findings at 2 years post-surgery. The Chi-squared test was used for differentiation among the types of stems based on remodeling status. Statistical significance was set at p < 0.05.
The median value of mechanical stimulus was computed in each Gruen zone using numerical simulation data. Statistical correlation was conducted between median values of mechanical stimulus and clinical observations of three types of remodeling modes from 2-years postoperative radiographs.
3. Results
3.1. Biomechanical Model Predicts Long-Term Femoral Bone Remodeling
The mechanical stimulus at the implant–bone interface estimated from postoperative radiographs correlates with clinically observed radiographic remodeling patterns two years postoperatively (
Figure 1). Mechanical stimulus was significantly higher in zones with observed apposition that in zones without observable remodeling or radiographically observed resorption (Mann–Whitney–Wilcoxon test with
p value
p < 0.001,
Figure 2). Our preliminary findings suggest that bone apposition may be influenced by mechanical stimulus in the context of patient-specific biomechanical analysis. However, no statistically significant association was found between the overall observed remodeling patterns and the type of stem used (Chi-square test,
p = 0.44). These results should therefore be interpreted with caution, as the limited cohort size may have constrained the ability to detect subtle differences between implant designs. Proxima stems exhibited the highest proportion of new bone apposition in zones 1 and 6 while the Minima and Collo-MIS stems showed more frequent bone loss or inactivity in these zones as also predicted by the biomechanical model (
Table 1). All implants demonstrated bone resorption or inactivity in zone 7 both in clinical findings and numerical models except the Proxima stem in numerical simulations and the Col-lo-MIS stem showing the most pronounced resorption in radiological observations (
Figure 1 and
Table A1).
3.2. Stem Positioning Is Related to Bone Remodeling
Simulated surgical malpositioning, in both valgus and varus alignments, resulted in cortical bone overload (
Figure 3). However, the extent of this overload varied considerably among the tested stem designs. While the Collo-MIS and Minima stems demonstrated tolerance to both valgus and varus malpositioning, the Proxima stem exhibited localized cortical bone overload when malpositioned. Specifically, the biomechanical stimulus at the stem bone interface, under malaligned conditions, exceeded normal loading levels, potentially leading to bone cortical hypertrophy.
4. Discussion
In this study, we evaluated the bone remodeling of three different classes of short stems at two years post-surgery. While other studies focus mostly on comparison between stems of the same class, our study compares short stems of three different classes. We showed that all three stems showed very similar remodeling changes with most new bone apposition being observed in the Gruen zones G3 and G5 both in clinical results and numerical simulations. There were no statistically significant differences in remodeling between the stems. Our simulations suggest that the highest biomechanical strain may occur in zones G3 and G5 when using the Proxima stem, with the predicted bone stimulus appearing to be influenced by both stem positioning and implant classification. However, these observations should be interpreted cautiously due to the exploratory nature of the study and the limited sample size.
4.1. Limitations
This study included only three different types short stems. These, however, were of three separate classes with differing modes of primary fixation. This allows for their direct comparison in clinical and biomechanical performance (
Figure 1). While the Proxima stem is not produced any more, we consider the knowledge of its biomechanical properties to be important for further development of new short stem designs of class 2a. All implants were implanted using free hand surgery implantation of stems without robotic assistance by one surgeon with extensive experience. Our study indicates the advantage of navigated surgery of short-stem THA to achieve accurate implant placement (
Figure 3). However, the comparison in
Figure 3 is based on analysis of single patient geometry with extreme varus and valgus position. The results should be therefore considered as qualitative and may differ for patients with different bone geometry or quality and/or different implant position. As the implant position was estimated from a planar radiograph, its three-dimensional antero-posterior inclination was not measured. Large anterior or posterior inclination of the implant would be exhibited by its shorter length on the radiograph [
21], which was not observed in patients included in our study. It was shown in a cadaveric study that even a small deviation from the optimal position could influence primary stability [
22].
The cohort size with this study was limited by the requirement of a single surgeon performing all surgeries. This potentially reduced variations due to surgeon experience or technique but considerably reduced the available number of patients. As a result, the statistical power of the study is limited. We acknowledge that with a larger patient cohort, it is likely that clearer and potentially statistically significant differences in mechanical stimulus—particularly between bone resorption and no activity, as suggested in
Figure 3—could emerge. The majority of patients were excluded from this study due to missing two- year postoperative radiographs. When considering a follow-up study, it should be designed as a prospective study with rigorous follow-up procedures and periods. Such a study would also allow evaluation of time-dependent remodeling during the early and late postoperative periods.
A key limitation of this study is that the biomechanical analysis was based entirely on 2D postoperative radiographs, as no 3D imaging (e.g., CT) was available. Consequently, the finite element models were constructed and analyzed in two dimensions, and the remodeling predictions were derived from 2D strain energy distributions. While this approach simplifies the inherently 3D nature of bone remodeling, it enables consistent modeling across a broader patient population, where 3D imaging is often not part of routine clinical follow-up. CT data would allow design of three-dimensional models with location and patient-specific bone material parameters [
23]. Moreover, even when CT imaging is available, its quality in the presence of metallic implants is frequently compromised due to beam-hardening artifacts and scattering, which can significantly distort bone geometry and density information. As such, 2D radiographs remain a more practical and reliable source for postoperative modeling in many clinical settings.
We have shown that apposition level is dependent on increased mechanical stimulus, but it can also lead to pathological overload. In the remodeling estimation based on standard radiographs and a single-parameter biomechanical model, we did not differentiate between pathological overload and trabecular formation. The model could be further improved by adding an additional level of mechanical stimulus indicating bone overload that should be verified by additional DEXA measurements.
4.2. Biomechanical Model Predicts Long-Term Femoral Bone Remodeling
Our preliminary results suggest that the biomechanical model may be capable of estimating bone apposition based solely on a postoperative radiograph taken 6 weeks after surgery, even though the model does not explicitly incorporate biological processes such as bone metabolism or remodeling. These results are supported by independent measurement of bone density measurement by the DEXA method in another study, showing bone apposition in regions 3 and 5 [
13]. The model was not able to significantly differentiate between the bone loss or the lack of activity observed from radiographs. The only zone where bone resorption was reliably observed was in zone 7. Our results support observations that short stems prevent stress shielding by design when compared to standard stems [
8,
13].
4.3. Stem Positioning Is Related to Bone Remodeling
Simulation of different stem positions revealed noticeable variations in cortical bone loading among the three designs. In particular, the Proxima stem appeared to exhibit a tendency toward increased cortical loading under extreme varus or valgus alignment. However, given the exploratory nature of the study, these findings should be interpreted with caution and warrant further investigation in larger cohorts. We assume that this observation is due to the short design of the implant, leading to a sharp point contact of the implant and cortical bone, which leads to such high measured strain values. This correlates with clinical observations where cortical hypertrophy was observed in clinical cases with these stem positions [
5]. For clinical application, this implies that the Proxima stem is susceptible to these pathologic remodeling modes when implanted in abnormal positions. Some studies have pointed out the difficulty in proper stem alignment with the Proxima stem and recommend its use only by experienced surgeons [
24].
In the Collo-MIS stem, we observed much smaller stress values in general (
Figure 2). We understand this to mean that the load is distributed more efficiently through the stem to the endosteal bone of the metaphysis. The Collo-MIS stem as part of its design utilizes the neck as part of its primary fixation while using impactors to compress the cancellous bone into the shape of the implant. This means that the stem should not be in direct contact with cortical bone distally but has a layer of compressed cancellous bone allowing for remodeling into trabecular structures that may transfer load in a more physiological way. In a clinical study of Collo-MIS stems, CCD angle measurements showed a mean +2° variation compared to mean physiological values in 60% of cases, and no cortical overloading was observed [
25]. These results corroborate with our numerical results showing no cortical overload in the neutral position (
Figure 3).
The Minima stem (class 3a) shows no considerable differences between the varus, valgus, and neutral positions with the maximum strain being transferred to the lateral cortex in G3 Gruen zone in all positions. We assume this is due to the shape of the stem and method of implantation. The shape allows for deep implantation of the stem and wide cortical contact in all positions. Clinically, this means that the Minima stem potentially tolerates implantation in abnormal positions and can be more suited to general use even with less experienced surgeons. This method of primary fixation, however, requires direct contact between the stem and distal cortical bone, which can lead to bone overloading clinically presenting as cortical hypertrophy [
26].
On the radiographic observations, there were several different modes of bone formation with some showing formation of new trabecular structure attaching the surface of the stem if there was not in contact with cortical bone which allowed for formation of trabecular structures. In other situations, cortical hypertrophy was observed if either the medial or lateral surfaces of the stem were in direct contact with cortical bone. It can be assumed that trabecular bone is better adapted to transfer of force through it when compared to cortical bone, explaining this difference in new bone formation.
These preliminary findings suggest that bone remodeling may be more strongly influenced by stem positioning than by stem type alone. Certain stem designs appear to be more sensitive to malpositioning, which could lead to less favorable remodeling outcomes. In our simulations, the Proxima stem showed a greater dependency on accurate alignment to avoid such effects, whereas the Minima stem appeared more tolerant to positional variation. However, these trends require further validation in larger, clinically diverse cohorts.
5. Conclusions
Our results indicate that the biomechanical model may be capable of predicting bone remodeling patterns in the proximal femoral cortex following implantation of various short-stem THA designs. While the Proxima stem showed favorable trends in both biomechanical response and clinical indicators within our limited cohort, these findings should be interpreted as preliminary and require further validation in larger, more diverse patient populations. The applicability of the model was demonstrated in the analysis of three types of short-stem implants with three types of position, namely neutral, varus, and valgus in a single patient. This lays down a foundation for improving patient-specific preoperative planning by using patient radiographs to predict bone remodeling over time, based on stem position. Our findings suggest that implant positioning may play a more critical role in biomechanical outcomes than implant type alone. For example, the Collo-MIS stem demonstrated favorable biomechanical behavior in neutral alignment but showed increased cortical loading under extreme varus or valgus positioning compared to the other designs. These observations highlight the potential importance of precise surgical technique—such as the use of centering impactors or navigation-assisted implantation—particularly when using the Collo-MIS stem. In contrast, the Proxima and Minima stems appeared more tolerant to positional variation in our simulations. This study indicates that the combination of clinical data and patient-specific models has potential in predicting implant performance and optimizing patient-specific treatment and follow-up strategies. Further research is warranted to refine and validate these predictive tools in larger patient cohorts.
Author Contributions
Conceptualization, J.H. and M.D.; methodology, M.H.; validation, M.D. and A.S.; formal analysis, M.H.; investigation, J.H.; data curation, M.H.; writing—original draft preparation, J.H. and M.H.; writing—review and editing, M.D. and A.S.; visualization, M.H.; supervision, A.S.; All authors have read and agreed to the published version of the manuscript.
Funding
This research was supported by the Czech Ministry of Education, Youth and Sports project No. CZ.02.01.01/00/23_020/0008512.
Institutional Review Board Statement
The present study protocol was reviewed and approved by the institutional review board of Motol University Hospital (Reg. No. EK-587/24, approval date: 2 October 2024).
Informed Consent Statement
Patient consent was waived due to the retrospective character of the study where only anonymized radiographs were used.
Data Availability Statement
Dataset available on request from the authors.
Conflicts of Interest
The authors declare no conflicts of interest.
Abbreviations
The following abbreviations are used in this manuscript:
FEA | Finite Element Analysis |
SED | Strain Energy Density |
CT | Computed Tomography |
THA | Total Hip Arthroplasty |
JISRF | Joint Implant Surgery and Research Foundation |
DEXA | Dual-Energy X-ray Absorptiometry |
Appendix A
Table A1.
Radiographic observations.
Table A1.
Radiographic observations.
Zone | Stem Type |
---|
Collo-MIS | Minima | Proxima |
---|
Resorption | Lazy Zone | Apposition | Resorption | Lazy Zone | Apposition | Resorption | Lazy Zone | Apposition |
---|
G1 | 20% | 60% | 20% | 20% | 80% | Not observed | Not observed | 40% | 60% |
G2 | 20% | 20% | 60% | Not observed | 40% | 60% | Not observed | Not observed | 100% |
G3 | Not observed | Not observed | 100% | Not observed | Not observed | 100% | Not observed | 40% | 60% |
G4 | Not observed | 100% | Not observed | Not observed | 100% | Not observed | Not observed | 80% | 20% |
G5 | Not observed | 40% | 60% | Not observed | 20% | 80% | Not observed | 40% | 60% |
G6 | 20% | 40% | 40% | Not observed | 80% | 20% | Not observed | 20% | 80% |
G7 | 60% | 40% | Not observed | 100% | Not observed | Not observed | 40% | 60% | Not observed |
References
- Khanuja, H.S.; Banerjee, S.; Jain, D.; Pivec, R.; Mont, M.A. Short Bone-Conserving Stems in Cementless Hip Arthroplasty. J. Bone Jt. Surg. 2014, 96, 1742–1752. [Google Scholar] [CrossRef]
- Gombár, C.; Janositz, G.; Friebert, G.; Sisák, K. The DePuy ProximaTM Short Stem for Total Hip Arthroplasty—Excellent Outcome at a Minimum of 7 Years. J. Orthop. Surg. 2019, 27, 2309499019838668. [Google Scholar] [CrossRef]
- Nishi, M.; Atsumi, T.; Yoshikawa, Y.; Nakanishi, R.; Watanabe, M.; Kudo, Y. Long-Term Outcomes of the Mayo Conservative Hip System in Patients Aged 30 Years or Less with Osteonecrosis of the Femoral Head: Mean Follow-up of More than 10 Years. Arch. Orthop. Trauma. Surg. 2024, 144, 2823–2830. [Google Scholar] [CrossRef]
- Capone, A.; Bienati, F.; Torchia, S.; Podda, D.; Marongiu, G. Short Stem Total Hip Arthroplasty for Osteonecrosis of the Femoral Head in Patients 60 Years or Younger: A 3- to 10-Year Follow-up Study. BMC Musculoskelet. Disord. 2017, 18, 301. [Google Scholar] [CrossRef]
- Melisik, M.; Hrubina, M.; Daniel, M.; Cibula, Z.; Rovnak, M.; Necas, L. Ultra-Short Cementless Anatomical Stem for Intracapsular Femoral Neck Fractures in Patients Younger than 60 Years. Acta Orthop. Belg. 2021, 87, 619–627. [Google Scholar] [CrossRef]
- McTighe, T.; Keggi, J.; Stulberg, S.D.; Keppler, L.; Brazil, D.; McPherson, E.J. Total Hip Stem Classification System. Reconstr. Rev. 2014, 4, 70. [Google Scholar] [CrossRef]
- Burchard, R.; Braas, S.; Soost, C.; Graw, J.A.; Schmitt, J. Bone Preserving Level of Osteotomy in Short-Stem Total Hip Arthroplasty Does Not Influence Stress Shielding Dimensions—A Comparing Finite Elements Analysis. BMC Musculoskelet. Disord. 2017, 18, 343. [Google Scholar] [CrossRef]
- Meyer, J.S.; Freitag, T.; Reichel, H.; Bieger, R. Periprosthetic Bone Mineral Density Changes After Implantation of a Curved Bone Preserving Hip Stem Compared to a Standard Length Straight Stem: 5-Yr Results of a Prospective, Randomized DXA-Analysis. J. Clin. Densitom. 2019, 22, 96–103. [Google Scholar] [CrossRef]
- Yan, S.G.; Chevalier, Y.; Liu, F.; Hua, X.; Schreiner, A.; Jansson, V.; Schmidutz, F. Metaphyseal Anchoring Short Stem Hip Arthroplasty Provides a More Physiological Load Transfer: A Comparative Finite Element Analysis Study. J. Orthop. Surg. Res. 2020, 15, 498. [Google Scholar] [CrossRef]
- Yan, S.G.; Li, D.; Yin, S.; Hua, X.; Tang, J.; Schmidutz, F. Periprosthetic Bone Remodeling of Short Cementless Femoral Stems in Primary Total Hip Arthroplasty. Medicine 2017, 96, e8806. [Google Scholar] [CrossRef]
- Yan, S.G.; Weber, P.; Steinbrück, A.; Hua, X.; Jansson, V.; Schmidutz, F. Periprosthetic Bone Remodelling of Short-Stem Total Hip Arthroplasty: A Systematic Review. Int. Orthop. 2018, 42, 2077–2086. [Google Scholar] [CrossRef]
- Brinkmann, V.; Radetzki, F.; Delank, K.S.; Wohlrab, D.; Zeh, A. A Prospective Randomized Radiographic and Dual-Energy X-Ray Absorptiometric Study of Migration and Bone Remodeling after Implantation of Two Modern Short-Stemmed Femoral Prostheses. J. Orthop. Traumatol. 2015, 16, 237–243. [Google Scholar] [CrossRef]
- Synder, M.; Krajewski, K.; Sibinski, M.; Drobniewski, M. Periprosthetic Bone Remodeling Around Short Stem. Orthopedics 2015, 38, S40–S45. [Google Scholar] [CrossRef]
- Gruen, T.A.; McNeice, G.M.; Amstutz, H.C. “Modes of Failure” of Cemented Stem-Type Femoral Components: A Radiographic Analysis of Loosening. Clin. Orthop. Relat. Res. 1979, 17–27. [Google Scholar] [CrossRef]
- Hambli, R. Connecting Mechanics and Bone Cell Activities in the Bone Remodeling Process: An Integrated Finite Element Modeling. Front. Bioeng. Biotechnol. 2014, 2, 6. [Google Scholar] [CrossRef]
- Bergmann, G.; Deuretzbacher, G.; Heller, M.; Graichen, F.; Rohlmann, A.; Strauss, J.; Duda, G.N. Hip Contact Forces and Gait Patterns from Routine Activities. J. Biomech. 2001, 34, 859–871. [Google Scholar] [CrossRef]
- Zaghloul, A. Hip Joint: Embryology, Anatomy and Biomechanics. Biomed. J. Sci. Tech. Res. 2018, 12. [Google Scholar] [CrossRef]
- Weinans, H.; Huiskes, R.; Grootenboer, H.J. The Behavior of Adaptive Bone-Remodeling Simulation Models. J. Biomech. 1992, 25, 1425–1441. [Google Scholar] [CrossRef]
- Elleuch, S.; Jrad, H.; Wali, M.; Dammak, F. Mandibular Bone Remodeling around Osseointegrated Functionally Graded Biomaterial Implant Using Three Dimensional Finite Element Model. Int. J. Numer. Method. Biomed. Eng. 2023, 39, e3750. [Google Scholar] [CrossRef]
- Ghaziani, A.O.; Soheilifard, R.; Kowsar, S. The Effect of Functionally Graded Materials on Bone Remodeling around Osseointegrated Trans-Femoral Prostheses. J. Mech. Behav. Biomed. Mater. 2021, 118, 104426. [Google Scholar] [CrossRef]
- Yoon, J.Y.; Seo, W.Y.; Kim, H.J.; Yoo, J.J. The Relationship between Femoral Stem Tilt and Stem Length in Total Hip Arthroplasty: A Retrospective Case-Control Study. Clin. Orthop. Surg. 2022, 14, 184. [Google Scholar] [CrossRef]
- Konow, T.; Glismann, K.; Lampe, F.; Ondruschka, B.; Morlock, M.M.; Huber, G. Stem Size and Stem Alignment Affects Periprosthetic Fracture Risk and Primary Stability in Cementless Total Hip Arthroplasty. J. Orthop. Res. 2024, 42, 829–836. [Google Scholar] [CrossRef]
- Todo, M.; Fukuoka, K. Biomechanical Analysis of Femur with THA and RHA Implants Using CT-Image Based Finite Element Method. J. Orthop. Sports. Med. 2020, 2, 89–107. [Google Scholar] [CrossRef]
- Tóth, K.; Mécs, L.; Kellermann, P. Early Experience with the Depuy Proxima Short Stem in Total Hip Arthroplasty. Acta Orthop. Belg. 2010, 76, 613–618. [Google Scholar]
- Rinaldi, G.; Capitani, D.; Maspero, F.; Scita, V. Mid-Term Results with a Neck-Preserving Femoral Stem for Total Hip Arthroplasty. HIP Int. 2018, 28, 28–34. [Google Scholar] [CrossRef]
- Thalmann, C.; Horn Lang, T.; Bereiter, H.; Clauss, M.; Acklin, Y.P.; Stoffel, K. An Excellent 5-Year Survival Rate despite a High Incidence of Distal Femoral Cortical Hypertrophy in a Short Hip Stem. HIP Int. 2020, 30, 152–159. [Google Scholar] [CrossRef]
| Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content. |
© 2025 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).