Study on the Variation in Shock Characteristics in a TNT-Based Shock Tube Under Different Experimental Conditions
Abstract
:1. Introduction
2. Shock Tube Experimental Setup
2.1. Shock Tube Description
2.2. Shock Tube Experimental Cases
3. Experiment Results
3.1. Experimental Results for Case 1
3.2. Experimental Results for Case 2
3.3. Experimental Results for Case 3
3.4. Summary
- Effect of TNT detonation position
- 2.
- Effect of shock tube and target contact on uniform pressure
- 3.
- Effect of sealing the driver section
- 4.
- Effect of expansion section
4. Conclusions
Author Contributions
Funding
Institutional Review Board Statement
Informed Consent Statement
Data Availability Statement
Conflicts of Interest
References
- Lee, S.J.; Park, J.Y.; Lee, Y.H.; Kim, H.S. Experimental analysis on the criteria of the explosion damage for one-way RC slabs. J. Korean Soc. Saf. 2017, 32, 68–74. [Google Scholar] [CrossRef]
- Schenker, A.; Anteby, I.; Gal, E.; Kivity, Y.; Nizri, E.; Sadot, O.; Michaelis, R.; Levintant, O.; Ben-Dor, G. Full-scale field tests of concrete slabs subjected to blast loads. Int. J. Impact Eng. 2008, 35, 184–198. [Google Scholar] [CrossRef]
- Morales-Alonso, G.; Cendon, D.A.; Galvez, F.; Erice, B.; Sanchez-Galvez, V. Blast response analysis of reinforced concrete slabs: Experimental procedure and numerical simulation. J. Appl. Mech. 2011, 78, 051010. [Google Scholar] [CrossRef]
- Army, U.S. Design of Structures to Resist the Effects of Accidental Explosions; Technical Manual TM5, 1300; United States Army: Arlington, VA, USA, 2008. [Google Scholar]
- Twisdale, L.A.; Sues, R.H.; Lavelle, F.M. Reliability-based design methods for protective structures. Struct. Saf. 1994, 15, 17–33. [Google Scholar] [CrossRef]
- Bogosian, D.; Ferritto, J.; Shi, Y. Measuring uncertainty and conservatism in simplified blast models. In Proceedings of the 30th Explosives Safety Seminar, Atlanta, GA, USA, 13–15 August 2002. [Google Scholar]
- Louar, M.A.; Belkassem, B.; Ousji, H.; Spranghers, K.; Kakogiannis, D.; Pyl, L.; Vantomme, J. Explosive driven shock tube loading of aluminium plates: Experimental study. Int. J. Impact Eng. 2015, 86, 111–123. [Google Scholar] [CrossRef]
- Li, Y.; Algassem, O.; Aoude, H. Response of high-strength reinforced concrete beams under shock-tube induced blast loading. Constr. Build. Mater. 2018, 189, 420–437. [Google Scholar] [CrossRef]
- Viau, C.; Doudak, G. Behavior and modeling of glulam beams with bolted connections subjected to shock tube-simulated blast loads. J. Struct. Eng. 2021, 147, 04020305. [Google Scholar] [CrossRef]
- Burrell, R.P.; Aoude, H.; Saatcioglu, M. Response of SFRC columns under blast loads. J. Struct. Eng. 2015, 141, 04014209. [Google Scholar] [CrossRef]
- Hammoud, A. Performance of High-Strength Reinforced Concrete Columns Under Shock-Tube Induced Blast Loading. Ph.D. Thesis, University of Ottawa, Ottawa, ON, Canada, 2017. [Google Scholar]
- Nian, W.; Subramaniam, K.V.; Andreopoulos, Y. Experimental investigation on blast response of cellular concrete. Int. J. Impact Eng. 2016, 96, 105–115. [Google Scholar] [CrossRef]
- Aune, V.; Fagerholt, E.; Langseth, M.; Børvik, T. A shock tube facility to generate blast loading on structures. Int. J. Prot. Struct. 2016, 7, 340–366. [Google Scholar] [CrossRef]
- Aune, V.; Casadei, F.; Valsamos, G.; Langseth, M.; Børvik, T. A shock tube used to study the dynamic response of blast-loaded plates. Proceedings 2018, 2, 503. [Google Scholar] [CrossRef]
- Kristoffersen, M.; Pettersen, J.E.; Aune, V.; Børvik, T. Experimental and numerical studies on the structural response of normal strength concrete slabs subjected to blast loading. Eng. Struct. 2018, 174, 242–255. [Google Scholar] [CrossRef]
- Skotak, M.; Alay, E.; Zheng, J.Q.; Halls, V.; Chandra, N. Effective testing of personal protective equipment in blast loading conditions in shock tube: Comparison of three different testing locations. PLoS ONE 2018, 13, e0198968.2018. [Google Scholar] [CrossRef] [PubMed]
- Andreotti, R.; Colombo, M.; Guardone, A.; Martinelli, P.; Riganti, G.; di Prisco, M. Performance of a shock tube facility for impact response of structures. Int. J. Non-Linear Mech. 2015, 72, 53–66. [Google Scholar] [CrossRef]
- Johnson, J.; Xu, M.; Jacques, E. Self-centering hybrid GFRP-steel reinforced concrete beams for blast resilience. J. Struct. Eng. 2021, 147, 04021099. [Google Scholar] [CrossRef]
- Phillips, E.E.; Murphy, R.; Connors, J.; McMullen, K.F.; Jacques, E.; Bruhl, J.C. Experimental evaluation of OSB-faced structural insulated panels subject to blast loads. Eng. Struct. 2021, 229, 111597. [Google Scholar] [CrossRef]
- Johnson, J.; Xu, M.; Jacques, E. Predicting the self-centering behavior of hybrid FRP-steel reinforced concrete beams under blast loading. Eng. Struct. 2021, 247, 113117. [Google Scholar] [CrossRef]
- Rhouma, M.B.; Maazoun, A.; Aminou, A.; Belkassem, B.; Vandenbruwane, I.; Tysmans, T.; Lecompte, D. Blast Loading of Small-Scale Circular RC Columns Using an Explosive-Driven Shock Tube. Buildings 2024, 14, 921. [Google Scholar] [CrossRef]
- Mu, Y.; Zhang, J.; Yang, M.; Huang, H.; Mao, Y.; Huang, H.; Zheng, X. Characterization of a large caliber explosively driven shock tube. Rev. Sci. Instrum. 2024, 95, 115103. [Google Scholar] [CrossRef]
Method | References | Shock Tube | Peak Reflected Pressure (MPa) | Impulse (MPa ms) | |||||
---|---|---|---|---|---|---|---|---|---|
Driver Section (mm) | Driven Section (mm) | ||||||||
Cross-Section | Length | Cross-Section | Length | ||||||
Shape | Dimension | Shape | Dimension | ||||||
Compressed gas | Ottawa’s shock tube [8,9,10,11] | Circle | 597 | 305~5158 | Square | 2032 | 6096 | 0.1 | 2.2 |
Nian et al. [12] | Circle | 89 | 1300 | Circle | 45 | 3300 | 0.5~1.5 | - | |
SIMLab shock tube [13,14,15] | Circle | 331 | ~2020 | Square | 300 | 16,120 | - | - | |
Skotak et al. [16] | - | - | - | Square | 710 | 6800 | - | - | |
Andreotti et al. [17] | Circle | 481 | 2350 | Circle | 481 | 10,500 | 1.83 | ||
Combustible gas | Virginia Tech Shock Tube Research Facility [18,19,20] | - | Rectangle | 2143 × 2440 | - | 0.2 | 2 | ||
Detonation | Louar et al. [7] | Circle | 168.2 | 1200 | Circle | 168.2 | - | 13 | - |
Rhouma et al. [21] | Circle | 100 | 800 | Circle | 100 | - | 15.3~32.3 | 2.1~3.8 | |
Mu et al. [22] | Circle | 2500 | 18,000 | Circle | 2500 | - | - | - |
Case | TNT (kg) | TNT Location | Sealing of Left Side of Driver Section | Target and Shock Tube Contact Status | Expansion Section |
---|---|---|---|---|---|
1-1 | 4.5–18 | Middle | Sealed | Not in contact | Not used |
1-2 | 8.8–13.2 | Left End | Sealed | In contact | Not used |
2-1 | 0.45–1.35 | Left End | Sealed | In contact | Not used |
2-2 | 0.45–0.9 | Left End | Opened | In contact | Not used |
3-1 | 1–17.6 | Left End | Sealed | In contact | Used |
3-2 | 4.4–8.8 | Left End | Opened | In contact | Used |
Case | Incident Pressure | ||||||
---|---|---|---|---|---|---|---|
Pso 1 (5 m) | Pso 2 (7 m) | Pso 3 (9 m) | Pso 4 (11 m) | Pso 5 (13 m) | Pso 6 (13.85 m) | Pso 7 (14.85 m) | |
1-1 | O | O | O | O | O | ||
1-2 | O | O | O | O | O | O | O |
2-1 | O | O | O | O | O | O | O |
2-2 | O | O | O | O | O | O | O |
3-1 | O | O | O | O | |||
3-2 | O | O | O | O |
Case | Distance from the Center to the Measurement Point of the Reflected Pressure (mm) | ||||
---|---|---|---|---|---|
Pr 1 | Pr 2 | Pr 3 | Pr 4 | Pr 5 | |
1-1 | 100 | 250 | 300 | 350 | 450 |
1-2 | 150 | 200 | 350 | 400 | |
3-1 | 30 | 400 | 450 | 600 | 800 |
3-2 | 30 | 400 | 450 | 600 | 800 |
Case | Round | TNT (kg) | Sealing Status | Peak Incident Pressure (MPa) | ||||
---|---|---|---|---|---|---|---|---|
Pso 1 | Pso 2 | Pso 3 | Pso 4 | Pso 5 | ||||
1-1 | 1 | 4.5 | Sealed | 1 | 1 | 1 | 1 | 1 |
2 | 4.5 | Sealed | 2.45 | 1.84 | 1.57 | 1.42 | 1.25 | |
3 | 4.5 | Sealed | 1.84 | 1.93 | 1.49 | 1.24 | 0.89 | |
COV | 0.14 | 0.024 | 0.026 | 0.068 | 0.17 |
Case | Round | TNT (kg) | Sealing Status | Peak Incident Pressure (MPa) | ||||
---|---|---|---|---|---|---|---|---|
Pso 1 | Pso 2 | Pso 3 | Pso 4 | Pso 5 | ||||
1-1 | 4 | 9 | Sealed | 4.13 | 3.06 | 2.66 | 2.58 | 1.87 |
5 | 9 | Sealed | 5.33 | 3.98 | 2.70 | 2.82 | 2.38 | |
6 | 9 | Sealed | 4.28 | 3.48 | 2.34 | 2.93 | 2.16 | |
COV | 0.12 | 0.11 | 0.06 | 0.05 | 0.1 |
Case | Round | TNT (kg) | Sealing Status | Peak Incident Pressure (MPa) | ||||
---|---|---|---|---|---|---|---|---|
Pso 1 | Pso 2 | Pso 3 | Pso 4 | Pso 5 | ||||
1-1 | 7 | 13.5 | Sealed | 7.05 | 5.48 | 4.63 | 3.17 | 2.63 |
8 | 18 | Sealed | 6.43 | 4.89 | 4.51 | 3.42 | 4.01 |
Locations | Arrival Time (ms) | |
---|---|---|
1st Peak Pressure | 2nd Peak Pressure | |
Pso 2 | 2.76 | 6.85 |
Pso 3 | 4.51 | 8.39 |
Pso 5 | 8.32 | 12.60 |
Case | Round | TNT (kg) | Sealing Status | Peak Reflected Pressure (MPa) | COV | ||||
---|---|---|---|---|---|---|---|---|---|
Pr 1 | Pr 2 | Pr 3 | Pr 4 | Pr 5 | |||||
1-1 | 1 | 4.5 | Sealed | 4.42 | 3.98 | 3.53 | 2.75 | 2.6 | 0.20 |
2 | 4.5 | Sealed | 4.36 | 3.89 | 4.62 | 2.62 | 2.46 | 0.25 | |
3 | 4.5 | Sealed | 4.36 | 3.84 | 3.95 | 2.26 | 2.2 | 0.27 | |
COV | 0.0065 | 0.015 | 0.11 | 0.081 | 0.068 |
Case | Round | TNT (kg) | Sealing Status | Peak Reflected Pressure (MPa) | COV | ||||
---|---|---|---|---|---|---|---|---|---|
Pr 1 | Pr 2 | Pr 3 | Pr 4 | Pr 5 | |||||
1-1 | 4 | 9 | Sealed | 7.92 | 7.93 | 6.56 | 4.67 | 4.71 | 0.23 |
5 | 9 | Sealed | 8.65 | 7.8 | 7.48 | 4.93 | 4.59 | 0.24 | |
6 | 9 | Sealed | 8.06 | 8.32 | 7.38 | 5.03 | 5.47 | 0.20 | |
COV | 0.039 | 0.028 | 0.058 | 0.031 | 0.079 |
Case | Round | TNT (kg) | Sealing Status | Peak Reflected Pressure (MPa) | COV | ||||
---|---|---|---|---|---|---|---|---|---|
Pr 1 | Pr 2 | Pr 3 | Pr 4 | Pr 5 | |||||
1-1 | 7 | 13.5 | Sealed | 12.01 | 13.64 | 10.72 | 5.7 | 7.67 | 0.29 |
8 | 18 | Sealed | 12.87 | 13.49 | 11.52 | 7.59 | 18.09 | 0.27 |
Case | Round | TNT (kg) | Sealing Status | Peak Incident Pressure (MPa) | ||||||
---|---|---|---|---|---|---|---|---|---|---|
Pso 1 | Pso 2 | Pso 3 | Pso 4 | Pso 5 | Pso 6 | Pso 7 | ||||
1-2 | 9 | 4.4 | Sealed | 2.72 | 2.07 | 1.66 | 1.51 | 1.76 | 1.21 | 1 |
10 | 4.4 | Sealed | 1 | 2.09 | 1.58 | 1.30 | 1.52 | 1.17 | 1.24 | |
11 | 4.4 | Sealed | 2.01 | 2.42 | 2.00 | 1.43 | 1.57 | 1.43 | 1.40 | |
COV | 0.15 | 0.07 | 0.10 | 0.06 | 0.06 | 0.09 | 0.06 |
Case | Round | TNT (kg) | Sealing Status | Peak Incident Pressure (MPa) | ||||||
---|---|---|---|---|---|---|---|---|---|---|
Pso 1 | Pso 2 | Pso 3 | Pso 4 | Pso 5 | Pso 6 | Pso 7 | ||||
1-2 | 12 | 8.8 | Sealed | 3.61 | 2.14 | 2.04 | 1.59 | 2.16 | 1.90 | 1.89 |
13 | 8.8 | Sealed | 2.76 | 2.60 | 2.19 | 1.63 | 2.22 | 2.06 | 1.90 | |
COV | 0.13 | 0.1 | 0.04 | 0.01 | 0.01 | 0.04 | 0.003 |
Case | Round | TNT (kg) | Sealing Status | Peak Incident Pressure (MPa) | ||||||
---|---|---|---|---|---|---|---|---|---|---|
Pso 1 | Pso 2 | Pso 3 | Pso 4 | Pso 5 | Pso 6 | Pso 7 | ||||
1-2 | 14 | 13.2 | Sealed | 2.01 | 1.62 | 1.78 | 1.40 | 1.50 | 1.20 | 0.98 |
Locations | Arrival Time (ms) | |
---|---|---|
1st Pressure | 2nd Pressure | |
Pso 2 | 3.03 | 18.47 |
Pso 5 | 7.58 | 12.78 |
Pso 7 | 9.69 | 10.4 |
Case | Round | TNT (kg) | Sealing Status | Peak Reflected Pressure (MPa) | COV | |||
---|---|---|---|---|---|---|---|---|
Pr 1 | Pr 2 | Pr 3 | Pr 4 | |||||
1-2 | 9 | 4.4 | Sealed | 6.17 | 4.99 | 6.13 | 5.66 | 0.083 |
10 | 4.4 | Sealed | 5.37 | 5.02 | 5.46 | 6.04 | 0.067 | |
11 | 4.4 | Sealed | 6.67 | 5.87 | 6.43 | 7.25 | 0.076 | |
COV | 0.088 | 0.077 | 0.068 | 0.11 |
Case | Round | TNT (kg) | Sealing Status | Peak Reflected Pressure (MPa) | COV | |||
---|---|---|---|---|---|---|---|---|
Pr 1 | Pr 2 | Pr 3 | Pr 4 | |||||
1-2 | 12 | 8.8 | Sealed | 10.82 | 10.13 | 8.54 | 8.55 | 0.10 |
13 | 8.8 | Sealed | 9.31 | 7.71 | 6.65 | 6.59 | 0.15 | |
COV | 0.075 | 0.14 | 0.12 | 0.13 |
Case | Round | TNT (kg) | Sealing Status | Peak Incident Pressure (MPa) | ||||||
---|---|---|---|---|---|---|---|---|---|---|
Pso 1 | Pso 2 | Pso 3 | Pso 4 | Pso 5 | Pso 6 | Pso 7 | ||||
2-1 | 15 | 0.45 | Sealed | 0.42 | 0.34 | 0.20 | 0.19 | 1 | 0.17 | 0.19 |
16 | 0.45 | Sealed | 0.30 | 0.22 | 1 | 0.18 | 1 | 0.18 | 1 | |
17 | 0.45 | Sealed | 0.53 | 0.34 | 0.25 | 0.25 | 1 | 0.18 | 1 | |
18 | 0.45 | Sealed | 0.41 | 0.36 | 0.25 | 0.24 | 1 | 0.19 | 0.21 | |
19 | 0.45 | Sealed | 0.46 | 0.30 | 0.26 | 0.23 | 1 | 0.18 | 0.20 | |
20 | 0.45 | Sealed | 0.35 | 0.31 | 0.22 | 0.18 | 1 | 0.18 | 1 | |
COV | 0.18 | 0.15 | 0.095 | 0.14 | 0.03 | 0.04 |
Case | Round | TNT (kg) | Sealing Status | Peak Incident Pressure (MPa) | ||||||
---|---|---|---|---|---|---|---|---|---|---|
Pso 1 | Pso 2 | Pso 3 | Pso 4 | Pso 5 | Pso 6 | Pso 7 | ||||
2-1 | 21 | 0.9 | Sealed | 0.70 | 1 | 0.43 | 0.40 | 1 | 0.36 | 0.31 |
22 | 0.9 | Sealed | 0.70 | 1 | 0.40 | 0.41 | 1 | 0.33 | 0.34 | |
23 | 0.9 | Sealed | 0.97 | 0.57 | 0.45 | 0.44 | 1 | 0.32 | 0.32 | |
24 | 0.9 | Sealed | 0.79 | 0.46 | 0.39 | 0.38 | 1 | 0.32 | 0.31 | |
25 | 0.9 | Sealed | 0.92 | 0.64 | 0.47 | 0.46 | 0.34 | 0.33 | 0.33 | |
26 | 0.9 | Sealed | 0.82 | 0.72 | 0.46 | 0.44 | 0.33 | 0.34 | 0.36 | |
COV | 0.12 | 0.16 | 0.068 | 0.064 | 0.015 | 0.041 | 0.054 |
Case | Round | TNT (kg) | Sealing Status | Peak Incident Pressure (MPa) | ||||||
---|---|---|---|---|---|---|---|---|---|---|
Pso 1 | Pso 2 | Pso 3 | Pso 4 | Pso 5 | Pso 6 | Pso 7 | ||||
2-1 | 27 | 1.35 | Sealed | 1.07 | 1 | 0.56 | 0.59 | 1 | 0.45 | 0.44 |
28 | 1.35 | Sealed | 1.01 | 0.83 | 0.71 | 0.61 | 0.45 | 0.46 | 0.41 | |
29 | 1.35 | Sealed | 0.97 | 1.05 | 0.68 | 0.65 | 0.46 | 0.45 | 0.45 | |
COV | 0.04 | 0.12 | 0.10 | 0.040 | 0.011 | 0.010 | 0.040 |
Case | Round | TNT (kg) | Sealing Status | Peak Incident Pressure (MPa) | ||||||
---|---|---|---|---|---|---|---|---|---|---|
Pso 1 | Pso 2 | Pso 3 | Pso 4 | Pso 5 | Pso 6 | Pso 7 | ||||
2-2 | 30 | 0.45 | Opened | 0.32 | 0.20 | 0.13 | 0.08 | 1 | 1 | 1 |
31 | 0.45 | Opened | 0.30 | 0.20 | 0.13 | 0.10 | 1 | 0.12 | 0.12 | |
COV | 0.032 | 0 | 0 | 0.11 |
Case | Round | TNT (kg) | Sealing Status | Peak Incident Pressure (MPa) | ||||||
---|---|---|---|---|---|---|---|---|---|---|
Pso 1 | Pso 2 | Pso 3 | Pso 4 | Pso 5 | Pso 6 | Pso 7 | ||||
2-2 | 32 | 0.9 | Opened | 0.54 | 0.42 | 0.27 | 1 | 1 | 0.22 | 0.22 |
33 | 0.9 | Opened | 1 | 1 | 0.23 | 1 | 1 | 1 | 0.22 | |
34 | 0.9 | Opened | 0.60 | 0.32 | 0.19 | 0.29 | 1 | 1 | 0.23 | |
COV | 0.059 | 0.14 | 0.14 | 0.021 |
Case | TNT (kg) | Sealing Status | Average Peak Incident Pressure (MPa) | ||||||
---|---|---|---|---|---|---|---|---|---|
Pso 1 | Pso 2 | Pso 3 | Pso 4 | Pso 5 | Pso 6 | Pso 7 | |||
2-1 | 0.45 | Sealed | 0.41 | 0.31 | 0.24 | 0.21 | 0.18 | 0.2 | |
2-2 | 0.45 | Opened | 0.31 | 0.2 | 0.13 | 0.09 | 0.12 | 0.12 | |
2-1 | 0.9 | Sealed | 0.82 | 0.60 | 0.43 | 0.42 | 0.335 | 0.33 | 0.33 |
2-2 | 0.9 | Opened | 0.57 | 0.37 | 0.23 | 0.29 | 0.22 | 0.22 |
Case | Round | TNT (kg) | Sealing Status | Peak Incident Pressure (MPa) | |||
---|---|---|---|---|---|---|---|
Pso 1 | Pso 2 | Pso 3 | Pso 4 | ||||
3-1 | 35 | 1 | Sealed | 0.85 | 0.62 | 0.51 | 0.43 |
36 | 1 | Sealed | 1.08 | 0.68 | 0.63 | 0.50 | |
37 | 1 | Sealed | 1.11 | 0.75 | 0.63 | 0.56 | |
38 | 1 | Sealed | 0.94 | 0.67 | 0.56 | 0.54 | |
39 | 1 | Sealed | 1.10 | 0.75 | 0.68 | 0.57 | |
40 | 1 | Sealed | 0.86 | 0.70 | 0.52 | 0.52 | |
41 | 1 | Sealed | 1.09 | 0.79 | 0.65 | 0.57 | |
42 | 1 | Sealed | 0.91 | 0.75 | 0.59 | 0.55 | |
COV | 0.11 | 0.07 | 0.1 | 0.08 |
Case | Round | TNT (kg) | Sealing Status | Peak Incident Pressure (MPa) | |||
---|---|---|---|---|---|---|---|
Pso 1 | Pso 2 | Pso 3 | Pso 4 | ||||
3-1 | 43 | 2 | Sealed | 1.51 | 1.11 | 1.04 | 0.90 |
44 | 2 | Sealed | 1.70 | 1.46 | 1.14 | 0.85 | |
COV | 0.06 | 0.14 | 0.06 | 0.03 |
Case | Round | TNT (kg) | Sealing Status | Peak Incident Pressure (MPa) | |||
---|---|---|---|---|---|---|---|
Pso 1 | Pso 2 | Pso 3 | Pso 4 | ||||
3-1 | 45 | 4.4 | Sealed | 1.80 | 1 | 1.35 | 1.36 |
46 | 4.4 | Sealed | 2.23 | 1 | 1.44 | 1.38 | |
47 | 4.4 | Sealed | 2.25 | 1 | 1.93 | 1.56 | |
COV | 0.1 | 0.16 | 0.06 |
Case | Round | TNT (kg) | Sealing Status | Peak Incident Pressure (MPa) | |||
---|---|---|---|---|---|---|---|
Pso 1 | Pso 2 | Pso 3 | Pso 4 | ||||
3-1 | 48 | 8.8 | Sealed | 1 | 2.48 | 2.30 | 2.09 |
49 | 17.6 | Sealed | 2.55 | 2.73 | 2.17 | 1.81 |
Case | Round | TNT (kg) | Sealing Status | Peak Reflected Pressure (kPa) | COV | ||||
---|---|---|---|---|---|---|---|---|---|
Pr 1 | Pr 2 | Pr 3 | Pr 4 | Pr 5 | |||||
3-1 | 35 | 1 | Sealed | 0.39 | 0.46 | 0.45 | 0.36 | 0.47 | 0.10 |
36 | 1 | Sealed | 0.47 | 1 | 0.5 | 0.45 | 0.37 | 0.11 | |
COV | 0.093 | 0.053 | 0.11 | 0.12 |
Case | Round | TNT (kg) | Sealing Status | Peak Reflected Pressure (kPa) | COV | ||||
---|---|---|---|---|---|---|---|---|---|
Pr 1 | Pr 2 | Pr 3 | Pr 4 | Pr 5 | |||||
3-1 | 43 | 2 | Sealed | 1.06 | 1.05 | 1.03 | 0.93 | 1.03 | 0.046 |
44 | 2 | Sealed | 1.41 | 1.18 | 1.35 | 1.27 | 1.31 | 0.059 | |
COV | 0.14 | 0.058 | 0.13 | 0.15 | 0.12 |
Case | Round | TNT (kg) | Sealing Status | Peak Reflected Pressure (kPa) | COV | ||||
---|---|---|---|---|---|---|---|---|---|
Pr 1 | Pr 2 | Pr 3 | Pr 4 | Pr 5 | |||||
3-1 | 45 | 4.4 | Sealed | 2.14 | 2.26 | 2.16 | 2.1 | 2.16 | 0.024 |
46 | 4.4 | Sealed | 2.24 | 2.41 | 2.53 | 2.24 | 2.27 | 0.049 | |
COV | 0.023 | 0.032 | 0.079 | 0.032 | 0.025 |
Case | Round | TNT (kg) | Sealing Status | Peak Reflected Pressure (kPa) | COV | ||||
---|---|---|---|---|---|---|---|---|---|
Pr 1 | Pr 2 | Pr 3 | Pr 4 | Pr 5 | |||||
3-1 | 48 | 8.8 | Sealed | 4.64 | 3.75 | 3.91 | 3.84 | 3.6 | 0.091 |
49 | 17.6 | Sealed | 1 | 1 | 1 | 1 | 1 |
Case | Round | TNT (kg) | Sealing Status | Peak Incident Pressure (MPa) | |||
---|---|---|---|---|---|---|---|
Pso 1 | Pso 2 | Pso 3 | Pso 4 | ||||
3-2 | 50 | 4.4 | Opened | 1 | 1.42 | 1.27 | 0.97 |
51 | 4.4 | Opened | 1 | 1 | 1 | 1 | |
52 | 4.4 | Opened | 2.04 | 1.54 | 1.18 | 0.99 | |
53 | 4.4 | Opened | 1.51 | 1.61 | 1.11 | 1.12 | |
COV | 0.15 | 0.05 | 0.05 | 0.06 |
Case | Round | TNT (kg) | Sealing Status | Peak Incident Pressure (MPa) | |||
---|---|---|---|---|---|---|---|
Pso 1 | Pso 2 | Pso 3 | Pso 4 | ||||
3-2 | 54 | 8.8 | Opened | 2.55 | 2.73 | 2.17 | 1.81 |
Case | Round | TNT (kg) | Sealing Status | Peak Reflected Pressure (kPa) | COV | ||||
---|---|---|---|---|---|---|---|---|---|
Pr 1 | Pr 2 | Pr 3 | Pr 4 | Pr 5 | |||||
3-2 | 50 | 4.4 | Opened | 1.12 | 1.28 | 1.29 | 0.94 | 1.26 | 0.11 |
54 | 8.8 | Opened | 2.7 | 2.73 | 3.25 | 2.97 | 2.81 | 0.070 |
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content. |
© 2025 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
Share and Cite
Kwon, Y.; Kim, Y.; Park, J.; Kim, K. Study on the Variation in Shock Characteristics in a TNT-Based Shock Tube Under Different Experimental Conditions. Appl. Sci. 2025, 15, 2633. https://doi.org/10.3390/app15052633
Kwon Y, Kim Y, Park J, Kim K. Study on the Variation in Shock Characteristics in a TNT-Based Shock Tube Under Different Experimental Conditions. Applied Sciences. 2025; 15(5):2633. https://doi.org/10.3390/app15052633
Chicago/Turabian StyleKwon, Youngbeom, Yoonkeon Kim, Jongyil Park, and Kyoungmin Kim. 2025. "Study on the Variation in Shock Characteristics in a TNT-Based Shock Tube Under Different Experimental Conditions" Applied Sciences 15, no. 5: 2633. https://doi.org/10.3390/app15052633
APA StyleKwon, Y., Kim, Y., Park, J., & Kim, K. (2025). Study on the Variation in Shock Characteristics in a TNT-Based Shock Tube Under Different Experimental Conditions. Applied Sciences, 15(5), 2633. https://doi.org/10.3390/app15052633