Sound Source Localization Indoors Based on Two-Level Reference Points Matching

Appl. Sci. 2022, 12(19), 9956; https://doi.org/10.3390/app12199956
by Shuopeng Wang 1,*, Peng Yang 2,3 and Hao Sun 2,3
Reviewer 1: Anonymous
Reviewer 2:
Appl. Sci. 2022, 12(19), 9956; https://doi.org/10.3390/app12199956
Submission received: 31 August 2022 / Revised: 26 September 2022 / Accepted: 27 September 2022 / Published: 3 October 2022
(This article belongs to the Special Issue Audio and Acoustic Signal Processing)

Round 1

Reviewer 1 Report

Dear Authors,

I have reviewed your paper with interest.  I think this paper is well written.
I have some comments and questions. Please answer these.

---------------------------------
1) It may be difficult because there are many figures, but if possible, please adjust the layout and reduce the gaps on the page as much as possible.

2) Can the RP database once created be used as-is for different sound sources?

3) What is the actual processing time required to locate the sound source?
---------------------------------

sincerely yours

 

Author Response

Please see the attachment.

Author Response File: Author Response.pdf

Reviewer 2 Report

Authors proposed two-level matching strategy to shrink the adjacent RPs searching scope. Literature review background is appropriate to show the previous work about the related research. The mathematical analysis with experimental results are good. Figure quality looks good. English grammar looks fine. Thus, the manuscript could be minor revision.

1. Data availability section is missing.

2. Please use abbreviated journal names in the reference section.

3. Please provide city, country, and date information of the conference papers in the reference section.

4. Figure 2 labels seems to be a littble it small.

5. In Figure 9, the error was increased a lot. Why is that ? Is there any method to further reduce that ?

6. In Figure 9, how about the results author could be expected if the number of the positions are higher than 10 ?

7. If the positions are located in 3-axis, how the proposed method could be changed ?

Author Response

Please see the attachment

Author Response File: Author Response.pdf