1. Introduction
In the last 15 years, minimally invasive surgery has shown an increasing success rate in veterinary medicine, and numerous techniques are being proposed for many surgical procedures. Among them, ovariectomy (OVE) and ovariohysterectomy (OHE) are some of the most common surgical techniques performed in small animals [
1,
2,
3,
4,
5,
6,
7,
8]. When evaluating the main advantages of laparoscopic neutering procedures compared to the open conventional ones, most of the authors highlight lower trauma associated with smaller incisions, as well as a lower number of postoperative complications [
1,
3,
9]. Additionally, they also note lower rates of bleeding during surgery, less perioperative pain, reduced infection rates, decreased morbidity, and hospital stays [
3,
10,
11,
12].
Although laparoscopic surgery has many advantages, some complications have been described, mainly associated with the surgical access, the anesthesia management, and other procedures specific to laparoscopic techniques [
13,
14,
15]. Pathophysiological alterations have also been related to the abdomen insufflation with CO
2, which results in the establishment of pneumoperitoneum (PNP) [
16]. Specifically, the PNP leads to an elevated intra-abdominal pressure (IAP) with the consequent cranial displacement of the diaphragm, which induces changes in ventilatory and cardiovascular dynamics, such as decreased venous return, increased peripheral vascular resistance, decreased cardiac output, increased resistance to thoracic expansion, and decreased lung volume [
17,
18,
19]. The compression of the pulmonary parenchyma has been related to the appearance of atelectasis and ventilation/perfusion alterations [
17,
20]. Another critical event is associated with the insufflation of CO
2 and its absorption through the abdominal cavity, which may produce acid-base and cardiorespiratory disturbances [
21]. Presently, it is well-known that the severity of these alterations is positively correlated with higher IAP pressures [
22,
23]. For that reason, the current veterinary literature supports the use of IAP of maximum 10 mmHg in dogs [
24,
25] and below 6–8 mmHg in cats [
26,
27,
28]. Additionally, the duration of the PNP also appears to be another limiting factor in laparoscopic surgery, having an impact directly proportional to the systemic absorption of CO
2 and, therefore, increasing the number of complications associated with this fact [
21,
27,
29]. However, even following the recommended pressure values, complications may occur [
26,
27].
In relation to the pathophysiological changes that may occur during the laparoscopic surgery both in human [
19,
20,
30,
31,
32] and in veterinary medicine [
17,
21,
24,
33,
34], numerous publications have thoroughly examined these potential alterations. Some studies on animals recorded effects in terms of cardiovascular [
24,
29,
33,
35], respiratory [
17,
25,
26,
27,
34,
36] and metabolic parameters [
21,
29,
37].
On the other hand, several authors have examined the numerous advantages of minimally techniques compared to the open traditional ones in small animals. At present, most of them focus on the comparison of the perioperative complications, surgical recovery, and postoperative pain and morbidity [
1,
3,
9,
10,
11,
38], as well as inflammation response [
18,
39,
40]. However, there are only a few publications evaluating the systemic effects during PNP in the LAP neutering procedures compared to the open techniques. Höglund et al. [
41] recorded the changes in the blood pressure and heart rate during two surgical methods for neutering female dogs. Shariati et al. [
10] examined perioperative complications, blood loss, as well as some clinical and blood parameters in laparoscopic and open surgery for OVE in dogs. Kumari et al. [
42] evaluated the hemato-biochemical profile in bitches undergoing LAP and open Ove. Additionally, in another study on cats [
27], the authors evaluated the cardiopulmonary effects of low IAP in LAP OVE comparing these findings to those obtained in an open surgery approach.
Nevertheless, to the best of the authors’ knowledge, there are no studies on dogs that have examined the potential global pathophysiological differences and the gas inhalation requirements between both OVE surgical techniques. Therefore, the aim of this study is to quantitatively evaluate the potential cardiorespiratory and blood changes associated with the establishment of PNP in laparoscopic OVE, and to compare them to those determined in conventional open surgery in dogs in a randomized, prospective clinical trial. For those purposes, we collected cardiovascular and ventilatory variables and performed gasometrical, electrolyte, biochemical, and hematological analyses during the surgical procedure. Additionally, we examined the requirements for minimum alveolar concentration (MAC) gas inhaled, depending on the surgical technique, using the end-tidal sevoflurane concentration (FE’Sevo, %) during anesthesia. We hypothesized that the pathophysiological changes related to PNP would be transient and well-tolerated by the dogs. Furthermore, we also hypothesized that open OVE would result in a high MAC requirements for sevoflurane compared to laparoscopic surgery.
2. Materials and Methods
2.1. Animals
This prospective, randomized clinical study was conducted in the Rof Codina University Veterinary Hospital (Lugo, Spain) and was approved by the Ethics Committee of the Rof Codina Galician Public Foundation.
The inclusion criteria for this study were healthy client-owned female dogs admitted for neutering procedure. All animal owners were informed about the detailed study protocols and a written informed consent was obtained for each dog from the pet owner. The included animals were randomly assigned into two groups depending on the surgical technique, according to a computer-generated randomization list: laparoscopic ovariectomy group (LAP Ove, n = 8) and laparotomy ovariectomy group (LPT Ove, n = 8). All the procedures were performed by the same veterinary surgical team.
All the animals underwent an anamnesis, a physical examination and a complete blood cell analysis, and a serum biochemistry profile. Therefore, only dogs assigned to the ASA I (American Society of Anesthesiologist) and weighing more than 15 kg were included. Dogs were excluded from the study if they were affected by systemic disease, pregnancy, cardiac arrhythmias, or any technical or anesthetic complications. Additionally, in order to determine the sevoflurane requirements depending on the surgical technique, we also decided to exclude the animals that need intraoperative rescue analgesia. The study included general data on breed, age, weight, and body condition. For body condition assessment, a scale of one to five was used, with one being thin and five being obese [
43].
2.2. Equipment
The experimental work was carried out in the surgical area of the Rof Codina University Veterinary Hospital. The laparoscopic ovariectomies were performed using a Karl Storz
® endoscopy tower, consisting of modular equipment, which included: a Telecam camera with zoom, focus, brightness, and white balance control, a high-performance insufflator (Endoflator
® 50), a medical CO
2 bottle, and a power LED light source with fiber optic light cable. Two 6 mm threaded trocars with a blunt fixator were used, with one of them provided with gas inlet, and one 11 mm threaded trocar also provided with a gas inlet and a rubber reducer to allow the use of 5 mm instruments. A Hopkins
® model optic of 30°, with 5 mm in diameter and 29 cm in length, from Karl Storz was also used. A 5 mm diameter curved tip dissector was used for handling and holding the ovary. The cutting and coagulation of the ovaries was performed using an Ultracision
® harmonic scalpel with advanced hemostasis (HARMONIC ACE
® + 7 handpiece, ETHICON) [
11,
44].
2.3. Anesthesia and Analgesia
All animals underwent general anesthesia after premedication with medetomidine (10 µg/kg/IM, Domtor, Esteve, Barcelona, Spain) and morphine (0.3 mg/Kg/IM, Morfina Braun 2%, B. Braun Medical, Barcelona, Spain). Approximately 15 min afterwards, and once the patient was mildly-to-moderately sedated, a cephalic vein was catheterized (Abbocath T-20G) and an IV infusion rate with Ringer–Lactate solution was started (5 mL/kg/h, Braun
®, Barcelona, Spain). Additionally, meloxicam (0.2 mg/Kg/IV, Metacam, Boehringer Ingelheim España, Barcelona, Spain) was administered as a nonsteroidal anti-inflammatory analgesic [
45]. Each animal received antibiotic prophylaxis with cefazolin (22 mg/Kg/IV, Cefazolina Normon
®, Normon laboratories, Madrid, Spain), one dose 30 min prior to the surgery and another dose 60 min after the first incision.
The anesthesia was inducted with propofol injection (2 mg/Kg/IV, Propofol Lipuro
® 1%, Melsungen, Alemania). After endotracheal intubation, the patient was connected to an appropriate breathing system and the anesthesia was maintained with sevoflurane (vaporizer setting 2%) (SevoFlo
®, Esteve Veterinary, Barcelona, Spain) in O
2 100%. The anesthetic plane was evaluated every 15 min by eye position, jaw tone, and palpebral reflex. F
E’Sevo was adjusted accordingly by increasing or decreasing 0.5% of the previous vaporizer setting concentration each time until the appropriate anesthetic plane was achieved, which was established by the absence of palpebral reflex, loss of jaw tone, and ventrally rotated eye position [
46,
47]. If it was not enough, 1 mg/kg IV bolus of propofol was administered. Patients were placed in dorsal recumbency with a 15° head-up tilt (anti-Trendelenburg) and were mechanically ventilated in a volume-controlled mode with a ventilator (Mindray Anaesthesia Machine, WATO EX-65 Pro, Shenzhen, China). The initial tidal volume (TV) was established at 10 mL/Kg and afterwards was adjusted to maintain normocapnia, thereby establishing end-tidal carbon dioxide partial pressure (P
E’CO
2) at 35–45 mmHg. Additionally, we established a respiratory rate (RR) of 12–14/min, an inspiratory to expiratory ratio of 1:2, positive end-expiratory pressure (PEEP) of 4 cmH
2O and inspiratory pause of 50% inspiratory time.
Additionally, prior to surgery, the dorsal metatarsal artery was percutaneously catheterized with a 22–24 gauge catheter for invasive blood pressure monitoring and arterial blood collection (blood gas and electrolyte studies). This catheter was removed before anesthesia recovery. For postoperative pain management, meloxicam (0.2 mg/kg/PO) was administered by owners for three days following the day of the surgical procedure [
48,
49]
2.4. Surgical Procedure
2.4.1. Laparoscopic Ovariectomy Group
The LAP Ove surgeries were performed using a 3-portal technique with linear abdominal access [
50]. The first trocar (6 mm) was placed 1 cm caudal to the umbilicus using the modified Hasson technique [
51]. PNP was created with CO
2 insufflation, establishing an IAP of 8–9 mmHg which was maintained throughout the surgery. The 5 mm optic was introduced, and the remaining trocars were placed under direct vision. The second trocar (11 mm with reducer) was placed at an intermediate distance between the pubis and the umbilicus, while the third trocar (6 mm) was introduced 1 cm cranial to the umbilicus.
After the placement of the access portals, a general abdominal exploration was performed, and the patient was placed into left lateral recumbency for removing the right ovary and subsequently into right lateral recumbency for removing the left ovary. The coagulation and cutting of both ovarian pedicles, suspensory ligament, and the uterine horn were performed using a 5 mm harmonic scalpel forceps. Once the absence of bleeding was verified, the two ovaries were removed through the caudal port (11 mm trocar). The portal sites were closed by a simple continuous layer in the abdominal fascia using a 0 absorbable monofilament glyconate suture (Monosyn, B. Braun VetCare SA, Barcelona, Spain) and a simple intradermal pattern on the skin with a 2-0/3-0 absorbable suture (Monosyn, B. Braun VetCare SA, Barcelona, Spain).
2.4.2. Laparotomy Ovariectomy Group
For the conventional approach, an incision was made approximately 1 cm caudal of the umbilicus along the midline toward the pubis, for a length of approximately 4–8 cm (depending on the size of the patient) [
10]. After the dissection of the subcutaneous tissue, the
linea alba was located and a stab incision was made to access the abdominal cavity. Subsequently, a general inspection of the abdominal cavity was performed. Once the right ovary was located, a traction was carefully applied to allow its exteriorization and subsequent resection using the harmonic scalpel. Next, the left ovary was located and resected in the same way. After assessing the absence of bleeding, surgical closure was performed with 3 simple interrupted layers, using 0 monofilament suture in the abdominal fascia, 2-0 suture for subcutaneous layer, and a simple intradermal pattern on the skin with 2-0/3-0 absorbable suture.
2.5. Blood Sampling and Recorded Data
Anesthetic monitoring of the respiratory and hemodynamic variables was recorded using a multi-parametric monitor (Mindray multi-parametric monitor, iPM12 Vet). The parameters were manually collected every five minutes during the surgical procedure, but the statistical comparison of the data was performed with the values recorded at four different times: before PNP at the beginning of the surgery (T1), after the resection of the right ovary (T2), after the resection of the left ovary (T3), and at surgical closure after PNP deflation (T4). The following variables were considered for the study: the end-tidal CO2 (PE’CO2, mmHg), end-tidal concentration of sevoflurane (FE’Sevo; %), minute volume (MV; L/minute), peak inspiratory pressure (Ppeak; cmH2O), plateau pressure (Pplat; cmH2O), respiratory system compliance (C; mL/cmH2O), airway resistance (Raw; cmH2O), heart rate (HR; beats/minute), systolic (SAP; mmHg), diastolic (DAP; mmHg) and mean (MAP; mmHg) invasive blood pressure.
Additionally, blood samples were drawn before PNP insufflation (baseline) and immediately after deflation. Specifically, biochemical, and hematological parameters were determined by venous blood sampling (3 mL per sample): glucose (GLU; mg/dL), creatinine (CREA, mg/dL), total plasma proteins (TPP; g/dL), albumin (ALB; g/dL), globulins (GLOB; g/dL), alanine aminotransferase (ALT; UI/L), alkaline phosphatase (ALP; UI/L), hematocrit (PCV; %), hemoglobin concentration (HB; g/dL), white blood cells (WBC; K/μL), and platelet counts (PLT; K/μL). The biochemical parameters were carried out with an automatic biochemical analyzer (Catalyst One, IDEXX, Spain), and the hematologic values were obtained with the hematological analyzer (ProCyte Dx, IDEXX, Madrid, Spain). Moreover, arterial blood collection (1 mL per sample) was also performed using a heparinized syringe. Hydrogen ion concentration (pH), arterial partial pressure of carbon dioxide (PaCO2; mmHg), arterial partial pressure of oxygen (PaO2; mmHg), bicarbonate concentration (HCO3−; mEq/L), base excess (BE; mmol/L) and sodium, potassium, and chloride as electrolytes concentrations (Na+, K+, Cl−; mmol/L) (Electrolyte and Blood Gas Analyzer, IDEXX VetStat*, Madrid, Spain) were measured immediately after withdrawal.
2.6. Statistical Analysis
Statistical analyses were performed using the commercial software Sigma Plot 12.5 (Systat Software Inc., Chicago, IL, USA). The normality of the data was assessed using the Shapiro–Wilk test, and a Levene’s test was employed to assess the equality of variances of normal variables.
The analysis for the cardiorespiratory and FE’Sevo values, among the four different times (T1–T4), within the same group, were conducted using a repeated measures one-way analysis of variance (ANOVA) and by applying a post-hoc Holm–Sidak test. For non-normal variables, the statistical comparison was performed using repeated measures Friedman analysis followed by post-hoc Tukey test. Additionally, a paired Student’s t-test (normal distribution) or a Wilcoxon Signed Rank test (non-normal distribution) was used to compare the pre- and post- operative blood variables. The comparison of the variables between the two surgical groups (LAP Ove and LPT Ove group) was tested for significance using an unpaired Student’s t-test, or with a two-tailed Mann–Whitney U test when data did not follow a normal distribution. For all variables, the differences were considered statistically significant when p < 0.05.
4. Discussion
The laparoscopic OVE procedure has been determined as a valid and safe neutering method in dogs, being a less invasive and painful technique than the conventional procedure [
18,
38] However, it has also been associated with the occurrence of pathophysiological changes related to the establishment of PNP [
17,
21,
24,
41]. To the best of our knowledge, there is no study evaluating the cardiovascular and ventilatory parameters and complete blood analyses during the PNP in LAP Ove compared to conventional open ovariectomy in dogs. The same applies to MAC requirements of sevoflurane during anesthesia depending on the surgical technique.
As previously described, noticeable respiratory changes were found in laparoscopy surgeries mainly associated with the increase of IAP, which caused a cranial displacement of the diaphragm, decreasing the pulmonary distension, and reducing the functional residual capacity [
17,
19,
20,
52]. In our study, the establishment of PNP during the LAP Ove surgery resulted in a decrease in the compliance and an increase in the Ppeak and Pplat without affecting airway resistance. These results were in agreement with those observed by other authors, which determined that the establishment of the PNP, necessary to perform laparoscopic surgery, produced significant changes in pulmonary compliance and airway pressures [
17,
19,
31,
52]. For that reason, some authors have examined the use of spontaneous ventilation during laparoscopy surgeries [
21,
34] based on the fact that during mechanical ventilation, there is an increase in the inspiratory pressures. This pressure, in combination with an increased IAP, may in turn cause an increase in intrathoracic pressure thus reducing the cardiac output. Nevertheless, other studies associated spontaneous ventilation with a higher prevalence of respiratory problems, such as ventilation/perfusion disturbances and hypoventilation [
17,
20]. Additionally, similar to the results of our study, Raugh et al. [
19] demonstrated that although the creation of PNP induced ventilatory changes, these quickly returned to normal values after deflation.
The P
E’CO
2 results were similar to those published by Lee & Kim [
18], that is, no increased values during PNP were observed. The use of mechanical ventilation during LAP Ove seems to be capable of compensating the hypercapnia induced after CO
2 absorption, maintaining the P
E’CO
2 values in normocapnia. A previous study on dogs [
25] showed that in order to eliminate the absorbed CO
2 through the peritoneal cavity, an increased minute ventilation was required. Similar to the results obtained by Shih et al. [
27], our study did not find more requirements associated with the PNP. It may be associated with the use of low IAP values which should be better tolerated by the patients [
22].
As for the F
E’Sevo values registered, we observed that during ovarian resection, coinciding with a greater pain stimulus cause by the surgery, higher anesthetic requirements were determined in the LPT Ove group. This difference was statistically significant at T3 (left ovary resection), recording an increase by 0.55% of F
E’Sevo with respect to the LAP Ove group at the same point in time. MAC is a reliable quantitative measurement of the potency of inhaled anesthetic agents [
53]. Furthermore, ovarian stimulation pain is frequently noted in spaying procedures in companion animals [
54]. In this regard, the increase in the anesthetic MAC requirements in conventional open neutering surgery was in line with other research studies, in which it was determined that laparoscopy techniques caused less pain and surgical stress than conventional ones due to the smaller incision required and less traction on the ovarian pedicle [
1,
3]. To the best of the authors´ knowledge, there are no current scientific studies in veterinary medicine that specifically focus on the MAC requirements of sevoflurane associated with the surgical ovariectomy technique in dogs. Therefore, we consider that further studies are required in order to examine these preliminary values in a more specific and exhaustive manner.
In the study of the hemodynamic response to PNP, it was described that these alterations were mainly observed at the beginning of the surgical procedure as a result from the increase of the IAP, the patient position, and the hypercapnia, which can result in a decreased cardiac output. Additionally, it is well-known that hemodynamic perturbations are pronounced in patients with cardiac and vascular disease [
32]. At present, the prevention of the cardiovascular alterations is being thoroughly studied. In a recent publication, Di Bella et al. [
33] have shown that the pulse pressure variation can be a valid predictor of the hemodynamic response to laparoscopy in dogs. Moreover, it could be used to prevent the cardiac output reduction by allowing to optimize the fluid therapy before PNP.
In our study, in the evaluation of the cardiovascular changes in healthy dogs, we determined the highest arterial blood pressure values during ovarian resection. Although hardly any significant differences were recorded between both surgical groups, this increase was slightly more marked at T2 in the LPT Ove group compared to the LAP Ove group. This is in line with the findings of other authors, and it was probably associated with a higher pain stimulus [
1,
41]. Regarding pain management during ovarian ligation, in a recent publication Cicirelli et al. [
7] have investigated the potential benefits of using local anesthetic drugs in order to provide an adequate analgesia. The study showed that a local splash block using lidocaine resulted in greater hemodynamic stability and lower surgical pain. Likewise, increases in the arterial pressure were also recorded during trocar placement. It has been demonstrated that the use of a smaller number of portals [
2,
41,
55,
56] and smaller instruments [
57] could be beneficial in contributing to decreased intraoperative pain. Regarding HR, tachycardia was described in laparoscopic surgery as a compensatory response related to the peritoneal cavity distension, as well as the stimulatory effects of hypercapnia [
24]. Nevertheless, it seems that the use of lower IAP helps to prevent significant cardiovascular changes [
25,
26]. In our case, in line with other studies [
10,
11,
18,
41,
52], no significant variations in the HR were determined. This was probably due to the PNP values established (8–9 mmHg), the type of premedication and anesthesia, as well as a possible baroreceptor reflex caused by the increased arterial pressure.
As we previously mentioned, among the pathophysiological changes associated with the establishment of PNP, in addition to the alterations caused by the IAP mechanical effect, metabolic and respiratory changes were also observed as related to the absorption of CO
2 through the peritoneum [
16,
20,
21,
25,
27,
37]. Among the main changes described, there were increases in the PaCO
2, decreases in the pH, decreases in the PaO
2 values, and increases in the plasma–bicarbonate concentrations. In our study, after evaluating the main pre- and post-PNP arterial blood gasometrical parameters, we did not determine statistically significant variations depending on the surgical technique or blood sample collection time. This was similar to other studies where the patient was mechanically ventilated during laparoscopic surgery [
17,
18]. Therefore, the use of mechanical ventilation at positive low volumes, and with the application of PEEP, seems to be crucial to ensure an effective ventilation, preventing alterations in the gas exchange rate, the appearance of atelectasis, and improving the lung function and respiratory mechanics [
17,
20]. Additionally, Russo et al. also observed an improved cardiac function associated with an enhanced CO
2 washout, oxygenation, and a vasoconstriction inhibition [
30].
Regarding the biochemical analyses performed, in the evaluation of the GLU plasma concentrations, in line with other publications [
11,
38], significantly higher values were determined in both groups after surgery. However, no statistically significant differences were observed depending on the surgical technique used. On the contrary, Devitt et al. [
1] recorded higher and prolonged hyperglycemia in the open OHE group compared to the laparoscopic-assisted one. Nevertheless, we should take into account that although blood GLU concentration has been examined in small animals as an indicator of postoperative pain [
58] and surgical stress response [
59], some authors did not determine this parameter as a useful measure of surgical stress or pain [
11]. In relation to the ALB, TPP, and GLOB levels, decreased values were determined after surgery in both groups. This is different from what was observed in another publication [
40], in which no significant differences were determined in the serum ALB values among the sampling times.
As for the blood count parameters such as PCV, HB and PLT, there was a significant decrease after surgery in both groups, probably due to perioperative fluid administration, splenic sequestration, and surgical trauma. These results were in line with those published recently by Rubio et al. [
60], where significantly decreased values were also determined in PCV and PLT compared to baseline after open OHE in healthy dogs. Additionally, some authors observed greater loss of blood in the laparotomy with respect to laparoscopic techniques [
10,
18]. Shariati et al. [
10] determined less hemorrhage in LAP Ove than in the conventional approach. Nevertheless, similar to the results of our study, they did not find any differences in the complete blood count parameters between both groups. As for the concentration of WBC, previous publications have reported significantly increased post-operative values after OHE [
42,
60]. However, in our study, both groups showed a significant decrease in the immediately postoperative period, probably due to hemodilution. Nevertheless, this descent was more noticeable in the LAP Ove animals. The slightly higher leukocytes values observed in the LPT Ove group could correspond to a greater inflammatory and immune response, which is determined by a more invasive and painful technique than that performed with laparoscopic surgery [
1].
Finally, a better understanding of the pathophysiological effects of PNP is crucial for appropriate anesthetic and surgical planning. This is especially important in prolonged procedures or in high-risk patients with previous cardiorespiratory and metabolic pathologies. Although the insufflation of the abdominal cavity with CO
2 has been associated with numerous physiological and pathological changes, it has been proven that the use of low IAP [
22], in addition to an adequate selection of the parameters in the positive pressure ventilation, could allow the patients to physiologically respond, thus reducing the perioperative complications [
20,
30]. In conclusion, the results of our study suggested that local and systemic alterations related to PNP in LAP Ove seemed to be reversible after CO
2 deflation and well-tolerated by healthy patients. Thus, the laparoscopic approach for Ove should increasingly be considered the “gold standard” in neutering procedures in the veterinary field due to their lower invasiveness, better visualization, and fewer complications.
This study had several limitations, mainly that of a small patient population (limited to 8 dogs per group). As such, the results should be interpreted with caution. Therefore, further studies, including a power calculation, may be necessary to corroborate our preliminary results. Additionally, more blood sample collections during the surgery procedure and some hours afterwards would have contributed to a more complete evaluation of the pathophysiological changes under study. Lastly, taking into account the variety of LAP Ove techniques described in the literature, with a different number of portals described, the use of two portals rather than three may have been more appropriate, as recommended by some authors [
2,
41,
55].