Legionella Occurrence beyond Cooling Towers and Premise Plumbing

by
David Otto Schwake
1,
Absar Alum
2 and
Morteza Abbaszadegan
2,*
1
Department of Natural Sciences, Middle Georgia State University, 100 University Pkwy, Macon, GA 31206, USA
2
School of Sustainable Engineering and the Built Environment, Arizona State University, Tempe, AZ 85287, USA
*
Author to whom correspondence should be addressed.
Microorganisms 2021, 9(12), 2543; https://doi.org/10.3390/microorganisms9122543
Submission received: 6 November 2021 / Revised: 27 November 2021 / Accepted: 6 December 2021 / Published: 9 December 2021
(This article belongs to the Special Issue Legionella pneumophila: A Microorganism with a Thousand Faces)

Abstract

:
Legionella is an environmental pathogen that is responsible for respiratory disease and is a common causative agent of water-related outbreaks. Due to their ability to survive in a broad range of environments, transmission of legionellosis is possible from a variety of sources. Unfortunately, a disproportionate amount of research that is devoted to studying the occurrence of Legionella in environmental reservoirs is aimed toward cooling towers and premise plumbing. As confirmed transmission of Legionella has been linked to many other sources, an over-emphasis on the most common sources may be detrimental to increasing understanding of the spread of legionellosis. This review aims to address this issue by cataloguing studies which have examined the occurrence of Legionella in less commonly investigated environments. By summarizing and discussing reports of Legionella in fresh water, ground water, saltwater, and distribution system drinking water, future environmental and public health researchers will have a resource to aid in investigating these pathogens in relevant sources.

1. Introduction

Since their discovery as the causative agent of Legionnaire’s disease in 1976 [1], bacteria of the Legionella genus have become a major source of drinking water-related disease outbreaks [2]. Naturally occurring in water [3] and soil [4], Legionella possess traits that enable their survival in a wide variety of environmental conditions [5], including protozoan host parasitization [6]. Though numerous transmission sources have been implicated in the spread of legionellosis, transmission is thought to occur primarily through the inhalation of cells, commonly via aerosolized water from engineered systems [7]. Therefore, identifying potential transmission sources is a key step in learning more about the infectious risks of legionellosis [8]. Despite the known presence of Legionella in a multitude of environments, to date, a large portion of legionellosis epidemiological studies and monitoring programs have been focused on transmission that is linked to premise plumbing or cooling towers [9,10,11,12,13,14]. As these other reservoirs have lower reported contribution to human disease, it could be inferred that less studied sources of contamination are unimportant from a public health perspective. However, legionellosis cases have been traced to seemingly uncommon routes of transmission and the historical over-emphasis on cooling towers and tap-water may, ironically, even be partially responsible for under-reporting of legionellosis that is attributed to other contaminated sources [15].
The goal of this review is to address the potentially problematic de-emphasis of poorly understood environmental reservoirs for Legionella by summarizing their occurrence in the following sources that are related to drinking water: fresh water, ground water, saltwater, and distribution system drinking water. While outlining the reports of contamination in these environments, relevant conclusions that are posed by the individual studies will be discussed. In addition, certain methodological aspects from the various studies will be listed, as well as key results, such as positivity rates, concentration, and the detected species. The information that is provided may prove useful in further investigations on Legionella presence and concentrations in a variety of sources and in the determination of potential public health ramifications due to their occurrence.

2. Surface Freshwater

One of the first identified natural environmental sources for Legionella, surface freshwater, may also be one of the more relevant with regard to public health. The potential for human exposure to Legionella in natural surface water can come in many forms including directly through recreational water activities or more incidentally via aerosolization from bodies of water. Perhaps most important is the fact that surface water sources are often used to supply drinking water treatment plants and other engineered water systems. While conventional water treatment effectively reduces levels of fecally-derived microbes to relatively safe levels, Legionella’s ubiquity in surface water and the ability for regrowth and long-term survival in drinking water systems [16] can present risks that are not common with water-borne gastrointestinal pathogens. The summarized results from studies that are discussed in this section are listed in Table 1.

3. River Water

Shortly after the first reported cases of Legionnaires’ disease, environmental investigation determined rivers to be an environmental reservoir. An early study documented a near-constant presence of L. pneumophila in the littoral zones of lakes in the eastern United States [17]. Measurement by direct fluorescent antibody microscopy revealed >93% (14/15) positivity in samples from seven rivers. As the study was performed during the initial years of Legionella research, cross-reactivity was a concern for antibodies that were used, potentially impacting the high detection rates that were observed.
Cold temperature freshwater sources (even at <20 °C) have the potential to contain Legionella. In the Netherlands, 100% of river water near freezing temperatures of 3–4 °C were found to have to have a wide variety of microbial species, including L. pneumophila [19]. Perhaps even more unexpected, relatively high concentrations up to 2.5 × 103 cells/mL were recorded. It was speculated that the Legionella that were detected were survivors from the moderate summer or originated from wastewater discharge.
While pristine freshwater rivers with low levels of human contact may pose no direct legionellosis transmission risk, they still represent important natural reservoirs for Legionella. Water that was sampled from the Rio Branco River in the southern coast of Sao Paulo state, Brazil, was found to contain L. pneumophila [20]. Concentrated superficial water samples produced no culturable isolates and only the single species, in contrast to anthropogenically polluted downstream waters suggesting that there was contamination from a common source. The lower diversity and concentrations that were found in pristine sections of the same river could be common for similar natural environments.
Examination of natural waters can lead to the identification of novel Legionella species, including potential human pathogens. Multiple independent samples from the Elbe River in Germany contained culturable isolates of a previously unidentified species, L. dresdenensis [25]. Phenotypically, it is similar to both L. rubrilucens and L. pneumophila but the new species had a unique serotype profile and a demonstrated capability of invading and replicating within amoeba hosts. The routine water sampling also produced several strains of L. pneumophila.
Anthropogenic pollution can often lead to elevated contamination of Legionella in rivers. An environmental study to investigate the source of an L. pneumophila serogroup 1 outbreak in Norway discovered high levels downstream of an outlet for a biological treatment plant along the Glomma River [26]. Concentrations decreased with distance from the plant outlet yet remained high at 40 colony forming unit (CFU)/mL up to 1.6 km downstream of the plant, demonstrating a long-reaching effect of the discharge.
While some studies have demonstrated the impact of anthropogenic waste and seasonality on Legionella contamination in natural bodies of water, this is not always the case. Samples from the Tech River in Southern France upstream and downstream of discharge from thermal baths or a wastewater treatment plant revealed a significant increase in Legionella in only one of three sampling sites [27]. In addition, the concentrations remained stable over different seasons, potentially due to small shifts in the water temperature of 0–6 °C. High levels of contamination naturally occurring in the river may have impacted the results, with 100% of samples containing Legionella, with concentrations as high as 900 genomic units (GU)/mL.
High levels of Legionella in source water can lead to unsafe levels in drinking water when combined with insufficient treatment. Sampling of sites along the Jiulong River, Fujian province, China, revealed high levels of L. pneumophila, reaching up to 2.5 × 104 GU/mL [39]; all of the samples (16/16) tested positive. A nearby water treatment plant only demonstrated slightly greater than 1 log reduction in concentrations in treated water, presenting a scenario with a potential public health hazard.
The potential for water source biofilms to serve as habitats for Legionella was demonstrated in samples that were collected from the Yangtze River in Hubei province, China [31]. 100% (6/6) of biofilm samples from two branches, one natural river and one canal, contained Legionella and multiple species of amoebae. Although the concentrations were low relative to other bacteria, Legionella was found in all of the samples.
Although growth of Legionella is typically associated with parasitization of eukaryotic hosts, the presence of commonly associated host amoebae is not necessary for high levels of contamination. Water samples from the Puzih River in Taiwan demonstrated high frequencies of occurrence, yet amoebae were rarely detected [35]. Legionella were present in 63.1% (41/65) of the samples, despite <9% containing Hartmanella, Naegleria, or Acanthamoeba. The measured concentrations up to 103 GU/mL suggest alternative host organisms or extracellular replication allowed for the high levels that were observed in the river.
Legionella contamination in environmental sources is often linked to seasonality, with a higher frequency of detection typically observed in warmer months, although this is not always the case. A survey of five lakes and rivers in differing climate zones of South Korea demonstrated ubiquity of L. pneumophila, with positive PCR results from 14/100 samples [4]. While all of the sites had detectable L. pneumophila in at least one sample, higher positivity was observed during two sampling periods, both in winter. This atypical seasonality pattern throughout a variety of climates shows that other environmental factors beyond temperature play a role in Legionella populations.

4. Lake Water

Due to more stagnant conditions and potential for increased concentrations of nutrients, lakes may serve as more ideal natural habitats for Legionella than rivers. In an early environmental study of freshwater habitats, a large number of lakes and ponds in the United States (some thermally altered) were found to contain L. pneumophila [17]. More than 99% (767/771) of the samples from 55/56 sites tested positive by molecular analysis, despite the wide range of water quality parameters, including temperature (5.7–63 °C), pH (5.5–8.1), and oxygen concentration (0.3–8.2 mg/L). These results helped established the concept of ubiquity for Legionella in a wide variety of freshwater environments.
With the development of specific culture media, relevant data in the form of viable, culturable Legionella has been obtainable from environmental samples. Culturable Legionella were found in water from lakes and reservoirs in southern California, United States [18]. Although all of the samples tested positive by molecular or immunological assays, cultured isolates were only obtained from 25% (2/8) of the samples. Regardless of the lowered concentration and positivity that is often experienced with culture-based techniques, quantification of only living bacteria is an important advantage of this method.
Natural disasters often lead to increases in infectious disease rates, with hurricanes and floods often causing water pollution and civil infrastructure damage. An ecological study on the microbial water quality of Lake Pontchartrain, Louisiana, United States, following the effects of Hurricane Katrina revealed frequent Legionella contamination [21]. More than 72% (35/48) of the samples that were collected from the lake during fall, winter, and spring were positive, with lowered detection rates in winter suggesting seasonality. Despite frequent contamination of Legionella spp. and anthropogenic discharge into the lake, only a single sample was found to contain L. pneumophila.
While microbial life is ubiquitous in lake environments, the presence of thermotolerant bacteria in Antarctic habitats could be considered unexpected. Legionella were detected in 0 °C water samples that were collected in summer from two pristine lakes in King George Island, Antarctica [22]. Culture-based techniques successfully isolated a single L. pneumophila colony, with multiple species that were detected via PCR in both lakes. The presence of a diverse Legionella population in this setting was attributed to high concentrations of metal ions and the presence of protozoan host organisms.
A wide variety of Legionella have been found in lakes and other freshwater bodies, yet certain species are infrequently observed in these environments. In a rare observation in freshwater, L. longbeachae was among the species that were detected in samples from Lake Taihu, China [29]. The shallowness of the lake, which has an average depth of 1.9 m, may have contributed to the occurrence of this typically soil-associated species. Transient amoebae populations may have also played a role as intracellular Legionella were nearly twice as common as those not associated with a host.
Even with common occurrence, higher concentrations of Legionella in lakes may be caused by specific environmental conditions. During an environmental study to assess the impact of seasonal effects on the presence and species in Taiwanese reservoirs, extremely high concentrations of up to 1.6 × 106 cells/mL and 7.35 × 108 cells/mL were measured [36,40]. Although positivity was the highest in fall, the concentrations tended to peak in summer, with warmer regions in the south having more stable populations. Correlations with chlorophyll, dissolved oxygen, and conductivity were also reported, potentially describing the conditions that are responsible for the levels that were detected.
Often associated with heated engineered systems, Legionella is a diverse genus with members that are capable of surviving in a variety of stressful environments. The detection of Legionella spp. via PCR in 7/19 (36.8%) of samples from glacier lakes in Antarctica demonstrates this point [38]. Similar community structure of Legionella within geographically distant sites, as well as positive detection in one hypersaline lake, highlight the adaptability of specific members of the genus to extreme conditions.

5. Rainwater

Rainwater harvesting has been implemented for thousands of years [41], however, with rising global water scarcity, this technology has seen increasing use in recent history. Although often noted as being of superior quality to poorly treated drinking water from conventional sources, the potential for gastrointestinal disease that is linked to rainwater has been established [42]. Unfortunately, far fewer investigations have been performed to examine this source for pathogens that are capable of causing acute respiratory disease such as Legionella.
Environmental sampling on water systems utilizing rainwater was performed in a Legionnaires’ disease outbreak investigation in Auckland, New Zealand [23]. Out of 48 homes that were sampled, 7 containing household rainwater collection systems were positive for Legionella with high concentrations of 3 × 102 CFU/mL detected in a rainwater storage water tank. A rainwater-sourced water blaster at a local marina was also found to be contaminated with L. pneumophila serogroup 1, demonstrating an obvious route for transmission.
Rainwater that is harvested for potable use may not be the only form that is capable of legionellosis transmission, as rainwater puddles, particularly on roads, may pose a public health risk for drivers and pedestrians. L. pneumophila prevalence was detected in rain puddles on asphalt roads in Tokyo, Japan [24]. 1/10 rainwater samples were positive, and some puddles contained greater than 10 CFU/mL. A positive correlation between contamination and temperature was also noted, indicating a potentially increased risk for transmission from this source in warmer climates.
In another study, examination of 72 rainwater collection tanks from houses in 18 suburbs in Queensland, Australia demonstrated Legionella contamination [32]. Samples that were taken shortly after rains were analyzed by qPCR for the presence of L. pneumophila, with 6% of tanks being positive, with concentrations of 16–100 GU/mL. The large numbers of positive samples that were collected when water systems should have held the freshest and least stagnant water demonstrates the potential for contamination of these systems.
The presence of non-pneumophila species may also pose a health risk in drinking water systems. Metagenomic analysis of roof harvested rainwater collection tanks in Cape Province, South Africa, were shown to be frequently contaminated with several Legionella species [33]. Pyrosequencing identified eight known species in samples from 6/7 rainwater collection systems, including L. longbeachae, and Legionella were the most prevalent water pathogen that was identified. The fact that contamination was more extensive in harvested rainwater than in a local river highlights the need for proper water quality regardless of the source.
Although found in cold weather climates, it is reasonable to assume that low air temperatures could have an impact on the presence of Legionella in rainwater. Regardless, rainwater puddles sampled in the Netherlands were found to be contaminated [34]. Positivity was low (albeit with culture-based assays), with 3/77 samples that were positive for Legionella, including L. pneumophila. High ambient temperature of 20.3 °C may have contributed to these results, although it should be noted that all of the temperatures that were measured the day of sampling and in the preceding 14 days (6.9–20.3 °C) were near or below the typically minimum range for Legionella growth [43].
To date, most of the studies examining the occurrence of Legionella in natural water sources have been conducted on surface freshwater samples. Even though the majority of this research has documented generally low concentrations, vastly differing study-specific results have been produced. These highly variable reports on occurrence in freshwater could be, in part, due to a number of environmental factors differing between the study sites. Due to this apparent importance of habitat on the presence and concentration of Legionella, increasing knowledge on these relevant natural reservoirs under different conditions will continue to be important to gain a better understanding of the ecology of these pathogens.

6. Ground Freshwater

Similar to surface water, groundwater is often used as a source for drinking and recreational purposes. Typically, lower levels of water-borne pathogens that are present in non-contaminated sources, however, often leads to the treatment of groundwater being less substantial than for surface water. While these decreased levels of harmful microbes tend to hold true for gastrointestinal pathogens, Legionella have been shown to naturally inhabit even deep groundwater, albeit with lower positivity and concentrations compared to neighboring surface water. Potentially due to the reduced treatment/awareness and environmental factors such as natural heat, groundwater serves as a relatively common source of legionellosis outbreaks [44].
Concerning Legionella occurrence, groundwater is similar to surface freshwater, yet different in many ways. While surface water outside of tropical climates is commonly too cold to facilitate Legionella growth, groundwater can be heated by geothermal activity to temperatures that are optimal for growth. Although groundwater often lacks the potential for direct human contact, natural springs and artificial spas utilizing groundwater have long been established as habitats for Legionella [45] and routes of legionellosis transmission [46], demonstrating the importance of this source that is often neglected from a public health perspective. The summarized results from studies that discussed in this section are listed in Table 2.

7. Wells

Groundwater sources supplying water for potable purposes have long demonstrated potential for contamination. In the first large ecological study of this source, frequent contamination was detected in groundwater well samples from 16 states in the United States [18]. Nearly 95% of the samples from 29 public wells tested positive for a number of Legionella species. Although no culture positives were achieved and no samples contained L. pneumophila specifically, the high frequency of occurrence and concentrations > 40 cells/mL of other species demonstrated the potential for risk that is associated with this source.
The presence of PCR inhibitors in groundwater samples has been shown to drastically impact the accuracy of this detection method. Legionella were detected at high frequencies in both water (83%) and biofilm (75%) samples from two sites in the United States [48]. Decreased molecular detection was reported for both samples types when compared to cultivation, with 1/3 of samples exhibiting high levels of PCR inhibition. Heat enrichment of the samples at 35 °C was found to increase the accuracy of PCR detection.
Analysis of biofilms in groundwater wells have demonstrated frequent contamination, occasionally with surprising results. Biofilms from water meters, end caps, pipes, and coupons from wells in multiple states in the United States and provinces in Canada were found to contain up to 1.2 × 102 CFU/cm2, including L. pneumophila [49]. Wells that were sampled were not under the direct influence of surface water and received no recycled water, ruling out these sources as points of contamination. Culture-based techniques demonstrated increased levels of detection in water samples compared to molecular detection (44% vs. 26%) and water had higher positivity than biofilm (58% vs. 34%).
Hydrothermal groundwater that is heated to temperatures within the growth range of Legionella may have increased level of contamination. Groundwater samples from a series of boreholes in two geographically separated areas in central Portugal demonstrated a high frequency of occurrence [50]. Geothermal activity heated both areas (one containing artesian wells, the other a natural spring) to temperatures from 35–48 °C. Samples that were collected over a series of seven years revealed culturable Legionella, with >58% (68/116) of the samples tested positive. Several trends were observed, including a lack of positive samples during (but not after) chlorination, L. pneumophila presence in 100% of samples from one well, and no detection during the first year of operation of a new well.
Due to the metabolic requirement for oxygen, lower levels of Legionella are often noted in anaerobic waters. Molecular analysis of anaerobic and aerobic groundwater in the Netherlands revealed an increased frequency and concentrations in the latter [19]. Positivity was over double at 88%, while the maximum levels that were measured of 25 cells/mL were an order higher for aerobic water. A diverse array of 12 species were identified, L. worsleiensis being the most common, potentially due to high variable levels of oxygen and high concentrations of metals in the samples. Significantly lower diversity was reported in a similar study on groundwater supplies in the Netherlands [52], with the trend of higher detection in oxygen-rich water maintained.
Although the highest levels of Legionella in groundwater have been measured in heated sources, cold water wells have also demonstrated contamination. Groundwater samples from wells in Eastern Poland demonstrated 62.5% (10/16) positivity by molecular detection [53]. The samples were obtained directly from wells or from unheated and untreated private water supply taps on farms. Significantly lower positivity by culturing (6.3%) could have been related to the low water temperatures reducing the cultivability of the Legionella.
Shallow water tables present many unique conditions for groundwater including being under the direct influence of surface water and an increased potential for intrusion of microbes. Microarray analysis was performed on groundwater samples from wells in the Kathmandu Valley, Nepal to determine the occurrence of pathogens [57]. Legionella were among the 26 genera of pathogens that were detected and were present in 73% of samples that were collected from wells 4.6–12.2 m deep. In addition to the shallow depths of the wells, relatively warm water (up to 24 °C) and the effects of the monsoon season may have contributed to the high levels of contamination.
Water temperature and seasonality are often reported as being both correlated to Legionella contamination in groundwater sources or having little impact. Other environmental factors such as aquifer composition may play a larger role, as suggested in a study of Italian wells [61]. Culturable Legionella was detected in 31/145 wells, with PCR on the remaining 114 detecting DNA markers in 37 of the remaining wells. Water temperature was only weakly correlated with concentrations, but samples that were sourced from wells in porous as opposed to karst-fissured aquifers had higher levels, demonstrating an example of the complex interplay of environmental factors on Legionella populations.

8. Springs

Certain sources of groundwater can pose a significant risk of direct human exposure, with hot springs being popular recreational bathing sites in certain regions. The presence of Legionella in this source has been reported for many years [47] with environmental sampling within a French hot spring spa detecting 15 culturable species or serogroups, including L. pneumophila. Antibody titers of patients and therapists at the spa were highest for the dominant serogroup that was cultured. Renewed interest in bathing springs that are implicated in legionellosis transmission has prompted multiple recent studies, most in Asian countries.
Legionella were detected in weak alkaline carbonate spring water both from the groundwater source and samples that were collected in Taiwanese recreational areas [51]. A contamination rate of 33% was observed in hot springs/streams that were not impacted by humans and tubs in a bathing facility. Amoeba co-culturing greatly increased the detection rates in certain samples. Legionella were also detected in sodium bicarbonate and sulfur springs in Taiwan at similar levels [40]). Here, 38% of the samples that were collected from three springs tested positive for Legionella within host amoebae. H. vermiformis was the most commonly identified host and no free-living L. pneumophila were detected.
Unattended natural hot springs, known as noyu, are popular recreational water sites in Japan. Sampling of noyu from 11 prefectures revealed frequent Legionella contamination [54]. While concentrations were low, with a maximum of 3 CFU/mL, culturable Legionella were detected in 37% of the samples and 73% of prefectures. L. pneumophila, including serogroup 1, was by far the most common species, present in 87.5% (14/16) of the samples. The 33–41 °C sample temperatures may have contributed to the frequent occurrence detected.
Like many recreational bathing waters, hot spring water is often untreated, even when feeding a bathing facility. An environmental study to evaluate the frequency of L. pneumophila in Tunisian hot springs recorded high levels of contamination in therapeutic spas that were supplied by untreated deep spring thermal waters [55]. More than 70% (54/77) of the samples that were collected from spring outlets and facilities tested positive by molecular methods at a high concentration of 420 GU/mL, with significantly lower positivity and levels determined via culture-based techniques. Experiments demonstrated an L. pneumophila isolate to be more resistant to heat shock than a clinical strain; unsurprising given the 48–66 °C sample temperatures that were recorded.
Elevated temperatures and other factors that are associated with bathing facilities may lead to extreme levels of contamination in hot springs. Legionella were detected in samples from a resort in Beijing via culture-based techniques, quantitative PCR, and ethidium-monoazide quantitative PCR [56]. High positives (74–100%) were reported for each detection method, with all 121 samples testing positive by molecular techniques. The measured concentrations were particularly high for the sites that were sampled, with maximum levels reaching 1.5 × 103 GU/mL.
The correlation between Legionella contamination and amoebae has been reported for numerous sources, including hot springs. Waters from two hot spring recreation complexes in central and southern Taiwan demonstrated a positive correlation with H. vermiformis presence [35]. Molecular methods detected contamination in 48% of samples with an unusually high minimum concentration of 14 GU/mL. The lack of correlation between the occurrence of Legionella and Acanthamoeba or Naegleria species suggests a host preference for Hartmannella.
Recreational hot springs continue to be an increasingly relevant and studied source of Legionella occurrence and transmission. In Taiwan, 45 of 48 similar hot springs tested positive for Legionella via PCR [58], demonstrating the extremely common contamination that is possible for such sites. Additionally, the identification of a novel species (L. thermalis) that was detected in recreational springs highlights the importance of examination for these and other commonly over-looked sources [59].
Unsurprisingly, Legionella spp. from differing environments tend to be genetically distant, yet still may show a wide diversity. A sampling of hot springs and engineered water systems from a relatively geographically linked area around Wenzhou, China, produced 13 strains from 4 different serogroups [60]. Hot springs tended to have higher positivity (62.5%) and concentrations (up to 107 CFU/mL). Additionally, strains from hot springs tended to have more genetic homology than those from cooling towers or premise plumbing samples.

9. Saltwater

Aquatic environments with low to moderate osmotic pressures are thought to be the primary aquatic natural habitats for Legionella. While saltwater may produce environmental stress for bacterial cells, natural occurrence in and tolerance to this medium has long been reported for Legionella [62,63]. Research that is focused on the ecology of Legionella in saline sources is limited, often assuming freshwater contamination. Although this may often be the case, reports in high osmolality, isolated, and oceanic sites indicate salty environments may also be a natural habitat for Legionella. The summarized results from studies that are discussed in this section are listed in Table 3.

10. Marine

With the potential for exposure from recreational waters, as well as the risk that is posed by contamination of seawater sources for desalination plants, contamination of marine waters with Legionella has the capability to serve as a threat to public health. In one of the first reports of Legionella in saline waters, multiple coastal and estuarine sites in Puerto Rico demonstrated contamination [64]. The occurrence was detected in all 26 sites from 5 geographically separated areas on the island that were examined. Although several species were reported, L. pneumophila, including serogroup 1, was by far the most commonly detected at high concentrations of 3.1 × 104 CFU/mL. Environmental pollution from storm runoff, sewage, and factory effluent (including a large rum distillery) were presumed to play a role in the high levels of contamination that were recorded.
During examination of the impact of treated sewage on the presence of Legionella in ocean-receiving waters, contamination was detected both at outfalls and coastal waters in California, USA [65]. Samples from surface water and 30 m deep at outfall locations, as well as from a nearby surf zone were collected. The contamination was clearly traced from the deep-water outfalls, with positivity and concentrations dropping from 75% and 103 cells/mL to 14% and 28 cells/mL in the surf zone. A lack of culture results and seed experiments in ocean water samples suggested the formation of viable but non-culturable cells in response to the saltwater environment.
The tolerance of Legionella to saltwater compared to other naturally occurring microbes has been demonstrated. In a mesocosm study performed on 300 L of seawater from the Gulf of Lyons in the Mediterranean Sea, Legionella increased in abundance over time [66] After 281 h in the confined space of the tank, drastic changes in the microbial community of the collected seawater were observed with Legionella comprising nearly 20% of the bacterial clones. Present in the original sample, this recorded increase suggests the potential for blooms of this pathogen under certain conditions.
Anthropogenic pollution is often implicated in the occurrence of Legionella in marine environments. Examination of water samples from an estuarine region in the southern coast of Sao Paulo state, Brazil, revealed multiple species, including L. pneumophila [20]. The lack of diversity upstream of the site affected by untreated domestic sewage led to the conclusion that the salinity (7.8%) and human pollution of the estuary may have created environmental conditions favoring multiple species.
In a microbial ecology study on bacterial communities that were associated with healthy and diseased corals, Legionella were detected in samples containing coral and seawater [67]. Multiple species of corals were examined from sites along the coast of Taiwan, with Legionella DNA being detected in association with both healthy and sick specimens. The possibility of transient microbes from nearby anthropogenic sources, including nuclear power plant discharge, was suggested.
Legionella were detected in a warm-water coastal lagoon off the southern Adriatic coast of Italy [72]. While examining microbial communities during jellyfish blooms, molecular methods detected a previously unidentified species in surface samples that were collected in a site with low jellyfish levels. While a slightly cold freshwater spring intrusion may have led to the occurrence that was reported, the <28 °C waters could have facilitated growth in this environment.
Global warming may potentially lead to increasing water temperatures that are sufficient to support Legionella growth in new environments. In an ecological study to determine the effects of coastal water warming, Legionella occurrence was reported in water samples from Suruga Bay in Japan [73]. Multiple species were isolated from immediately processed samples that were collected in the fall and incubation at elevated temperature was shown to drastically increase the detected diversity in one sample.
The potential impact of anthropogenic pollution Legionella populations has been demonstrated in both freshwater and marine environments. In a survey of a Chesapeake Bay inlet, 38/38 samples near a wastewater treatment plant tested positive for Legionella genetic markers, with GU/mL levels in the thousands, increasing following rain events [74]. Similarly, field sampling in the Virgin Islands proceeding a hurricane reported higher concentrations of Legionella in more polluted coastal water sites [75]. Confusingly, temperature was strongly correlated with Legionella contamination in the Chesapeake Bay but not the Virgin Islands.

11. Inland Sources

While less common than ocean sources, inland saline aquatic environments share many characteristics, including the potential for human exposure. Amoeba isolates from 8/8 sediment samples from sewage-contaminated areas of the Great Salt Lake, Utah, United States contained Legionella DNA [68]. The sampling sites varied in salinity (3–140%) and were either mesotrophic or hypereutrophic. A total of 74% of the 53 amoeba isolates tested positive and L. pneumophila was an uncommon species that was detected, only present in 7.5% of amoebae. Samples that were collected in June showed increased positivity compared to those from August, potentially due to increased temperatures.
It can be assumed unique Legionella species that are naturally inhabiting saline environments would be adapted to their habitat, potentially with distinct proteomic profiles. A previously unidentified species, L. tunisiensis, was isolated via amoeba co-culturing in Lake Sabka, a hypersaline lake in Tunisia [69]. This novel species is interesting due to its large amount of potential coding sequences and unusually high number of resistance genes (50% more sequences and 37 more genes than L. pneumophila 130b). While not determined, a large number of encoded proteins could be related to mechanisms for overcoming osmotic stress.
Perhaps the most likely source of transmission of Legionella in saltwater, saline baths have demonstrated contamination. L. pneumophila was detected in 100% (15/15) of water and floating biofilm samples from balneotherapy facilities in Poland [70]. Water for the baths was supplied by thermal saline groundwater sources 700–1700 m deep and were measured at 30.7–36.5 °C. Legionella were major members of the microbial community, constituting 22% of the bacteria and reaching concentrations of 105 cells/mL. The combination of ideal growth temperatures, age of facilities (up to 80 years old), and low salinities of 1.5–5% likely contributed to the high levels of occurrence.
Another unique saline environment that was found to contain Legionella is Hot Lake, Washington, United States [71]. Metagenomic analysis of the bacterial community of the lake margin soil and water samples from this epsomite lake with high levels of magnesium sulfate revealed a high relative abundance of Legionella clones. While the samples appeared to contain similar microbiomes to common soil, with actinomycetes dominating by a wide margin, Legionella was one of the next most common genera that were detected. Even without cultured isolates, these results demonstrate that high representation of Legionella is possible in waters with near-saturated salinities.
With the majority of life on the planet residing in the ocean, it should come as no surprise that saltwater can be a rich environment with an incredibly important microbiome for ecological and public health purposes [76], possessing nutrients and conditions that are necessary for Legionella persistence and growth. While occurrence may be lower than other sources, saline aquatic habitats still serve as an important niche for Legionella both from an environmental reservoir and potential source of direct human exposure.

12. Drinking Water

It is thought that a large proportion of legionellosis cases can be linked to an exposure route via cooling towers or in-premise plumbing water, with these sources of transmission accounting for a majority of reported incidence in many parts of the world [2,10]. The importance of point-of-use distributed water signifies that the water treatment plants and distribution systems delivering this water are also important in the transmission of legionellosis. While it is often assumed that appropriate drinking water treatment sufficient to reduce gastrointestinal pathogen concentrations to safe levels will do the same for Legionella [77], this may not necessarily be true given their ability to resist environmental stress and replicate in oligotrophic conditions; there are key differences separating them from other waterborne pathogens and highlighting the importance of understanding the complex dynamics of populations in drinking water systems and treatment plants. A Morbidity and Mortality Weekly Report demonstrating Legionella were responsible for 66% of waterborne-disease outbreaks and 26% of illnesses suggests that current standards of drinking-water treatment may not be sufficient [78]. The summarized results from the studies that are discussed in this section are listed in Table 4.

13. Drinking Water Treatment Plants

While early investigations on the presence of Legionella within drinking water treatment plants frequently produced negative results [93] perhaps due to improved detection methodology, later studies have been successful in isolation from this environment. A molecular ecology study on bacterial biofilm communities in a drinking water production system fed by the Rhine River, identified the presence of Legionella DNA [80].
Analysis of amoebae-resistant bacteria after water treatment steps in a plant that was supplied by surface water in Paris, France, revealed the presence of Legionella within the isolated amoebae [82]. While only one Legionella-like amoeba pathogen was successfully cultured, indigenous amoeba isolates from sand biofilm, carbon filter biofilm, and post-carbon filtered water contained DNA from multiple Legionella species. The increased detection of Legionella within hosts suggests a potential for increased survival throughout the water treatment processes via amoeba endoparasitization.
The amplification of Legionella during water treatment may be possible, particularly in biologically active steps or with processing of anaerobic source water. A drinking water treatment plant in the Netherlands that was supplied by anaerobic groundwater demonstrated drastic increases in Legionella contamination during treatment [52]. While raw water and aeration tanks samples were below the limit of detection, rapid sand filter, pellet softener, and treated water samples each contained approximately 10 cells/mL. Although no isolates were cultured, the presence of multiple species, including L. pneumophila, after treatment presents a counter-intuitive dynamic in the system that was examined.
Another example of increase in Legionella concentration during water treatment was demonstrated in samples that were collected from a chlorination-based plant in Hubei province, China [31]. Molecular analysis of biofilm and water samples from a reaction tank, settling pond, sand filter, and clear water tank revealed a constant presence of Legionella in every sample type, albeit with fluctuating levels throughout the treatment process. Surprisingly, while the concentrations decreased significantly in clear water tank water samples, biofilm from this source contained over an order higher number of cells than any other sample type, 3 × 103 GU/g. While the literal concentration of Legionella may have led to these results, growth in these biologically active systems’ biofilms would be a reasonable possibility.

14. Drinking Water Distribution Systems

With the presence of Legionella within drinking water treatment plants well documented, it should come as no surprise that frequent occurrence has been demonstrated within drinking water distribution systems as well. In an environmental study on biofilms within the distribution system of a town that is fed by the Rhine River [79], Legionella were detected within biofilm that formed on a variety of coupons that were placed along points downstream of a treatment plant. While culturable cells were not observed, a high positivity by molecular detection was recorded, with 87.5% (14/16) of the sampling sets positive. Chlorine residual seemed to have little impact on Legionella survival in these systems as high positivity was reported both before and after the plant shifted from chlorine dioxide to UV based treatment.
The loss of disinfectant residual through the length of a distribution system can lead to water quality issues, including increased Legionella levels. Investigation of a distribution system in Pinellas County, FL, United States, revealed common contamination [81]. While Legionella presence was observed in biofilm and water samples from multiple sites along the system, including sampling stations, backflow valves, and master meters, dead-end streets had higher positivity. Additional sampling of previously identified high risk sites, including the ends of the distribution network and backwash areas, produce a single sampling event with 20% positivity, as well. The denaturing gradient gel electrophoresis analysis of certain biofilm samples showed Legionella to dominate populations, suggesting that low levels of chlorine residual may have had a greater impact on other, less resilient microbes.
Similar to the results from water treatment plants, water quality parameters often appear to have a seemingly minor impact on Legionella populations within drinking water distribution systems. Samples that were collected over time from sites within a Hungarian distribution system examined the relationships between pathogen occurrence and a number of environmental factors [83]. Little to no correlation was measured between contamination and temperature, turbidity, nitrate, sulfate, heterotrophic plate counts, total organic carbon, or chemical oxygen demand. Legionella were detected more commonly than Pseudomonas aeruginosa, a common member of the microbial community in drinking water.
In contrast to other reports, an environmental study on drinking water supplies in the Caribbean observed a correlation between Legionella concentration and certain environmental factors [84]. A total of three distribution systems that were connected to reverse osmosis saltwater treatment plants with either UV or chlorine disinfection were examined. An occasional correlation was measured between Legionella concentration and turbidity, ATP, and H. vermiformis levels. Culturable cells were detected in 41/49 samples at distances up to 15 km from treatment, with L. pneumophila representing 80% of colonies that were observed in samples from the UV treated systems. While positivity was high with both forms of treatment, concentrations were significantly lower in the chlorinated system.
Certain regions have recently made shifts toward using chloramination for drinking water disinfection in place of chlorination, and while chloramine has been proven effective against Legionella, in-depth examination of chloraminated systems are rare. A large-scale molecular survey of opportunistic pathogens and amoebae in two recently chloraminated drinking water distribution systems in the United States demonstrated high levels of Legionella contamination in taps that were connected to the system [39]. Legionella was detected in >33% (30/90) samples from one system and >83% (45/54) from another, with L. pneumophila observed in 4.4% and 5%, respectively. While high concentrations greater than 103 GU/mL were occasionally observed, culturable cells were only present in a single sample that was collected, suggesting a high potential for chloramine to trigger viable but non-culturable Legionella.
In another study of distribution systems, Legionella contamination rates from rural areas in eastern Poland were low [53]. Using a combination of culture-based and molecular detection methodology, only 7.4% of 27 samples that were collected from cold water taps on farms in three villages receiving chlorinated groundwater were positive. Although collected from hot water sources, the samples that were collected from the city of Lublin, a more urban environment, were significantly more likely to contain Legionella, with a 49% (22/45) positivity.
In certain regions with poorly established civil infrastructure or widespread populations, water quality issues may arise, and non-conventional drinking water distribution systems are often implemented, presenting potential ramifications for Legionella occurrence. Drinking water distribution systems and reverse osmosis water supply tankers in Basra Governate, Iraq, were found to contain high levels of contamination [86]. A total of 100% (18/18) of the samples that were collected from distribution system sites contained Legionella concentrations up to 400 CFU/mL, and while tankers exhibited lower levels of contamination, >66% (6/19) were positive. Drinking water treatment plant deficiencies may have played a role as a majority of effluent samples from 13 plants contained Legionella with a high concentration of 1.8 × 103 CFU/mL recorded. Indicative of additional public health risk, over 77% of L. pneumophila isolates that were identified in the study belonged to serogroup 1.
Individual studies examining drinking water systems from large regions have rarely been performed, despite the fact that stark variations have been reported with different detection methodologies and between systems. In one of the only such studies that was conducted in the United States, L. pneumophila serogroup 1 was commonly detected in cold water taps from 40 geographically dispersed sites [87]. A total of 272 samples from 68 sites were analyzed by PCR, revealing 29% of samples and 47% of sites were positive and an average concentration of 2 GU/mL. While similar detection rates and concentrations were observed for water containing chlorine or monochloramine, the variability in concentration was much lower for the latter.
Seasonality of Legionella in certain sources is feasible due to differences in temperatures situationally, allowing substantial growth potential. This effect was observed in both a chlorinated and a chloraminated water distribution system in South Australia [88]. Legionella and L. pneumophila concentrations were highest in both systems in the summer, with exceptionally high Legionella concentrations of up to 106 and 103 GU/mL, respectively. Levels were also noted to increase in a dead end and with increasing distance along one of the systems. While the warm summer water temperatures up to 27 °C may have contributed to the observed results due to reduction in disinfectant residual, increased potential for growth may have also been a factor.
Extensive differences in Legionella contamination may exist within relatively similar distribution systems. Biofilms that were sampled from domestic water meters in two close-by networks that were located in central Arizona, United States, exhibited vastly differing positivity [90]. Molecular analysis on biofilms that were collected from 67 water meters originating from the two distribution systems showed Legionella positivity of 26% in one (14% for L. pneumophila), with no positive samples coming from the other. Such a stark difference was surprising, given the nearly identical source waters and largely similar treatment methods that were employed for the two systems.
Drinking water distribution system infrastructure can often play a role in pathogen contamination, with larger municipal systems being more prone to contain areas of stagnation. High-risk areas in distribution networks, notably dead ends, have been associated with increased potential for water-borne pathogens due to several possible factors, including stagnation and loss of residual disinfectants. A phylogenetic study on L. pneumophila in biofilm and water samples that were collected from a variety of points, including suspect areas in the city of Alcoy, Spain, revealed a significant increase in positivity in dead ends [89]. Out of 180 chlorinated or unchlorinated samples that were collected, 18 were positive for Legionella, including 12/18 dead ends that were sampled. In addition, the only culturable Legionella that were detected in the study were isolated from street dead end samples. Interestingly, a positive correlation was measured with temperature and contamination but not chlorine presence. The greatly increased positivity in select locations highlights the importance of proper sampling to gauge the true levels of contamination in drinking water distribution systems.
Residual disinfection is assumed to lower total levels of pathogens in drinking water distributions systems and a comparison between a chloraminated system in the US versus a no-residual system in Norway demonstrated this held true for Legionella [91]. While no Legionella were detected in biofilm from water mains in the chloraminated system, 10/23 samples from a residual-free system had concentrations as high as 7.8 × 104 gene copies/cm2. Tap-water that was collected throughout both systems, however, showed relatively similar occurrence and concentrations, highlighting the often-reported effectiveness of chloramine on biofilm microbial populations.
Wide-spread sampling regimes in distribution systems often reveal ubiquitous Legionella presence in water mains. In a broad sampling of four drinking water distribution systems in Paris, Legionella were detected in 192/268 water samples at concentrations greater than 100 GU/mL [92]. While no correlation was reported between the contamination and a series of water quality parameters, including temperature, a high degree of seasonality was observed with higher concentrations and more consistent detection of Legionella in the spring.
Due to studies reporting low concentrations and sporadic occurrence, the relevance of Legionella contamination within drinking water distribution systems is typically overshadowed by that in buildings and cooling towers. Dismissal of the importance of distribution systems in legionellosis transmission could be unwarranted as increases in Legionella contamination within them due to disruptions, treatment failures, or other events and factors impacting the distributed water quality may play a part in outbreaks [2,94]. While total elimination of Legionella in drinking water systems may not be feasible, occurrence data in tap-water will be needed to develop reasonably specific treatment and monitoring guidelines in this source.

15. Conclusions

With increasing incidence of legionellosis worldwide and novel sources of transmission continuing to be discovered, the importance of documenting all possible reservoirs for Legionella is clear. This importance extends to environmental habitats that are not commonly linked to human disease at the current time. Additional knowledge on the occurrence of these pathogens in source water and distribution networks will be critical for the development of effective practices to limit transmission via commonly implicated point sources. Investigation of these poorly understood sources will also provide fundamental insight that is relevant to the physiology and ecology of Legionella in all environments, including cooling towers and premise plumbing systems, providing additional tools to combat legionellosis.
A longstanding and current limitation of all such investigations concerns the detection methodology that is employed. As demonstrated throughout this review, differing methods are capable of delivering contrasting results, both for detection and quantification. In addition to future studies that are designed to help researchers better interpret the ‘meaning’ of current detection techniques beyond raw data, research that is focused on improving current or developing novel methods will be critical for both field and laboratory studies of Legionella. Examples of several such advances include use of immunofluorescence solid phase cytometry [28] and microcolony-based quantification [85], both of which may help overcome error that is associated with environmental samples containing PCR inhibitors and poorly culturable cells.

Author Contributions

All authors have read and agreed to the published version of the manuscript.

Funding

This work was funded by the National Science Foundation Water and Environmental Technology Center at Arizona State University (grant number 1361815).

Institutional Review Board Statement

Not applicable.

Informed Consent Statement

Not applicable.

Data Availability Statement

Not applicable.

Acknowledgments

This work was funded by the National Science Foundation Water and Environmental Technology Center at Arizona State University All opinions expressed in this paper are the authors’ and do not necessarily reflect the policies and views of NSF. The authors would like to thank Wei Yao for assistance in article translation.

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. Brenner, D.J.; Steigerwalt, A.G.; McDade, J.E. Classification of the Legionnaires’ disease bacterium: Legionella pneumophila, genus novum, species nova, of the family Legionelleceae, familia nova. Ann. Intern. Med. 1979, 9, 656–658. [Google Scholar] [CrossRef] [PubMed]
  2. Brunkard, J.M.; Ailes, E.; Roberts, V.A.; Hilborn, E.D.; Craun, G.F.; Rajasingham, A.; Kahler, A.; Garrison, L.; Hicks, L.; Carpenter, J.; et al. Surveillance for waterborne disease outbreaks associated with drinking water—United States, 2007–2008. MMWR Surveill. Summ. 2011, 60, 38–68. [Google Scholar] [PubMed]
  3. Fliermans, C.B.; Cherry, W.B.; Orrison, L.H.; Thacker, L. Isolation of Legionella pneumophila from nonepidemic-related aquatic habitats. Appl. Environ. Microbiol. 1979, 37, 1239–1242. [Google Scholar] [CrossRef] [Green Version]
  4. Whiley, H.; Bentham, R. Legionella longbeachae and legionellosis. Emerg. Infect. Dis. 2011, 17, 579–583. [Google Scholar] [CrossRef]
  5. Vatansever, C.; Türetgen, I. Survival of biofilm-associated Legionella pneumophila exposed to various stressors. Water Environ. Res. 2015, 87, 227–232. [Google Scholar] [CrossRef] [PubMed]
  6. Declerck, P. Biofilms: The environmental playground of Legionella pneumophila. Environ. Microbiol. 2010, 12, 557–566. [Google Scholar] [CrossRef]
  7. Fields, B.S. The molecular ecology of legionellae. Trends Microbiol. 1996, 4, 286–290. [Google Scholar] [CrossRef]
  8. Parr, A.; Whitney, E.A.; Berkelman, R.L. Legionellosis on the Rise: A Review of Guidelines for Prevention in the United States. J. Public Health Manag. Pract. 2015, 21, E17–E26. [Google Scholar] [CrossRef] [Green Version]
  9. Den Boer, J.W.; Euser, S.M.; Brandsema, P.; Reijnen, L.; Bruin, J.P. Results from the National Legionella Outbreak Detection Program, the Netherlands, 2002–2012. Emerg. Infect. Dis. 2015, 21, 1167–1173. [Google Scholar] [CrossRef]
  10. Walser, S.M.; Gerstner, D.G.; Brenner, B.; Höller, C.; Liebl, B.; Herr, C.E. Assessing the environmental health relevance of cooling towers—A systematic review of legionellosis outbreaks. Int. J. Hyg. Environ. Health 2014, 217, 145–154. [Google Scholar] [CrossRef]
  11. Mercante, J.W.; Winchell, J.M. Current and emerging Legionella diagnostics for laboratory and outbreak investigations. Clin. Microbiol. Rev. 2015, 28, 95–133. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  12. Ehrhardt, J.; Alabi, A.S.; Kuczius, T.; Tsombeng, F.F.; Becker, K.; Kremsner, P.G.; Schaumburg, F.; Esen, M. Population structure of Legionella spp. from environmental samples in Gabon, 2013. Infect. Genet. Evol. 2015, 33, 299–303. [Google Scholar] [CrossRef]
  13. Tabatabaei, M.; Hemati, Z.; Moezzi, M.O.; Azimzadeh, N. Isolation and identification of Legionella spp. from different aquatic sources in south-west of Iran by molecular & culture methods. Mol. Biol. Res. Commun. 2016, 5, 215–223. [Google Scholar] [PubMed]
  14. Borella, P.; Guerrieri, E.; Marchesi, I.; Bondi, M.; Messi, P. Water ecology of Legionella and protozoan: Environmental and public health perspectives. Biotechnol. Annu. Rev. 2005, 11, 355–380. [Google Scholar]
  15. van Heijnsbergen, E.; Schalk, J.A.C.; Euser, S.M.; Brandsema, P.S.; den Boer, J.W.; Husman, A.M. Confirmed and Potential Sources of Legionella Reviewed. Environ. Sci. Technol. 2015, 49, 4797–4815. [Google Scholar] [CrossRef]
  16. Lau, H.Y.; Ashbolt, N.J. The role of biofilms and protozoa in Legionella pathogenesis: Implications for drinking water. J. Appl. Microbiol. 2009, 107, 368–378. [Google Scholar] [CrossRef] [PubMed]
  17. Fliermans, C.B.; Cherry, W.B.; Orrison, L.H.; Smith, S.J.; Tison, D.L.; Pope, D.H. Ecological distribution of Legionella pneumophila. Appl. Environ. Microbiol. 1981, 41, 9–16. [Google Scholar] [CrossRef] [Green Version]
  18. Lye, D.; Fout, G.S.; Crout, S.R.; Danielson, R.; Thio, C.L.; Paszko-Kolva, C.M. Survey of ground, surface, and potable waters for the presence of Legionella species by Enviroamp PCR Legionella kit, culture, and immunofluorescent staining. Water Res. 1997, 31, 287–293. [Google Scholar] [CrossRef]
  19. Wullings, B.A.; van der Kooij, D. Occurrence and genetic diversity of uncultured Legionella spp. in drinking water treated at temperatures below 15 °C. Appl. Environ. Microbiol. 2006, 72, 157–166. [Google Scholar] [CrossRef] [Green Version]
  20. Carvalho, F.R.; Vazoller, R.F.; Foronda, A.S.; Pellizari, V.H. Phylogenetic study of legionella species in pristine and polluted aquatic samples from a tropical Atlantic forest ecosystem. Curr. Microbiol. 2007, 55, 288–293. [Google Scholar] [CrossRef]
  21. Sinigalliano, C.D.; Gidley, M.L.; Shibata, T.; Whitman, D.; Dixon, T.H.; Laws, E.; Hou, A.; Bachoon, D.; Brand, L.; Amaral-Zettler, L.; et al. Impacts of hurricanes Katrina and Rita on the microbial landscape of the New Orleans area. Proc. Natl. Acad. Sci. USA 2007, 104, 9029–9034. [Google Scholar] [CrossRef] [Green Version]
  22. Carvalho, F.R.; Nastasi, F.R.; Gamba, R.C.; Foronda, A.S.; Pellizari, V.H. Occurrence and diversity of Legionellaceae in polar lakes of the Antarctic peninsula. Curr. Microbiol. 2008, 57, 294–300. [Google Scholar] [CrossRef]
  23. Simmons, G.; Jury, S.; Thornley, C.; Harte, D.; Mohiuddin, J.; Taylor, M. A Legionnaires’ disease outbreak: A water blaster and roof-collected rainwater systems. Water Res. 2008, 42, 1449–1458. [Google Scholar] [CrossRef]
  24. Sakamoto, R.; Ohno, A.; Nakahara, T.; Satomura, K.; Iwanaga, S.; Kouyama, Y.; Kura, F.; Kato, N.; Matsubayashi, K.; Okumiya, K.; et al. Legionella pneumophila in rainwater on roads. Emerg. Infect. Dis. 2009, 15, 1295–1297. [Google Scholar] [CrossRef] [PubMed]
  25. Lück, P.C.; Jacobs, E.; Röske, I.; Schröter-Bobsin, U.; Dumke, R.; Gronow, S. Legionella dresdenensis sp. nov., isolated from river water. Int. J. Syst. Evol. Microbiol. 2010, 60 (Pt 11), 2557–2562. [Google Scholar] [CrossRef]
  26. Olsen, J.S.; Aarskaug, T.; Thrane, I.; Pourcel, C.; Ask, E.; Johansen, G.; Waagen, V.; Blatny, J.M. Alternative routes for dissemination of Legionella pneumophila causing three outbreaks in Norway. Environ. Sci. Technol. 2010, 44, 8712–8717. [Google Scholar] [CrossRef] [PubMed]
  27. Parthuisot, N.; West, N.J.; Lebaron, P.; Baudart, J. High diversity and abundance of Legionella spp. in a pristine river and impact of seasonal and anthropogenic effects. Appl. Environ. Microbiol. 2010, 76, 8201–8210. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  28. Parthuisot, N.; Binet, M.; Touron-Bodilis, A.; Pounard, C.; Lebaron, P.; Baudart, J. Total and viable Legionella pneumophila cells in hot and natural waters as measured by immunofluorescence-based assays and solid-phase cytometry. Appl. Environ. Microbiol. 2011, 77, 6225–6232. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  29. Wang, N.; Xing, P.; Wu, Q.L.; Yu, D.W. Distribution and diversity of Legionella spp. in Lake Taihu in the winter. Huan Jing Ke Xue 2011, 32, 2125–2131. [Google Scholar] [PubMed]
  30. Wang, Q.; Lin, H.R.; Zhang, S.T.; Yu, X. Real-time PCR detection and quantification of emerging waterborne pathogens (EWPs) and antibiotic resistance genes (ARGs) in the downstream area of Jiulong River. Huan Jing Ke Xue 2012, 33, 2685–2690. [Google Scholar]
  31. Lin, W.; Yu, Z.; Zhang, H.; Thompson, I.P. Diversity and dynamics of microbial communities at each step of treatment plant for potable water generation. Water Res. 2014, 52, 218–230. [Google Scholar] [CrossRef]
  32. Ahmed, W.; Brandes, H.; Gyawali, P.; Sidhu, J.P.; Toze, S. Opportunistic pathogens in roof-captured rainwater samples, determined using quantitative PCR. Water Res. 2014, 53, 361–369. [Google Scholar] [CrossRef] [PubMed]
  33. Chidamba, L.; Korsten, L. Pyrosequencing analysis of roof-harvested rainwater and river water used for domestic purposes in Luthengele village in Eastern Cape Province of South Africa. Environ. Monit. Assess. 2015, 187, 41. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  34. van Heijnsbergen, E.; de Roda Husman, A.M.; Lodder, W.J.; Bouwknegt, M.; Docters van Leeuwen, A.E.; Bruin, J.P.; Euser, S.M.; den Boer, J.W.; Schalk, J.A. Viable Legionella pneumophila bacteria in natural soil and rainwater puddles. J. Appl. Microbiol. 2014, 117, 882–890. [Google Scholar] [CrossRef] [PubMed]
  35. Ji, W.T.; Hsu, B.M.; Chang, T.Y.; Kao, P.M.; Huang, K.H.; Tsai, S.F.; Huang, Y.L.; Fan, C.W. Surveillance and evaluation of the infection risk of free-living amoebae and Legionella in different aquatic environments. Sci. Total Environ. 2014, 499, 212–219. [Google Scholar] [CrossRef] [PubMed]
  36. Kao, P.M.; Hsu, B.M.; Change, T.Y.; Hsu, T.K.; Tzeng, K.J.; Huang, Y.L. Seasonal variation of Legionella in Taiwan’s reservoir and its relationships with environmental factors. Environ. Sci. Pollut. Res. Int. 2015, 22, 6104–6111. [Google Scholar] [CrossRef]
  37. Bakh, Y.Y.; Kim, H.S.; Rhee, O.; You, K.; Bae, K.S.; Lee, W.; Kim, T.; Lee, S. Long-Term Monitoring of Noxious Bacteria for Construction of Assurance Management System of Water Resources in Natural Status of the Republic of Korea. J. Microbiol. Biotechnol. 2020, 30, 1516–1524. [Google Scholar] [CrossRef]
  38. Shimada, S.; Nakai, R.; Aoki, K.; Shimoeda, N.; Ohno, G.; Kudoh, S.; Imura, S.; Watanabe, K.; Miyazaki, Y.; Ishii, Y.; et al. Chasing Waterborne Pathogens in Antarctic Human-Made and Natural Environments, with Special Reference to Legionella spp. Appl. Environ. Microbiol. 2021, 87, e02247-20. [Google Scholar] [CrossRef]
  39. Wang, H.; Edwards, M.; Falkinham, J.O.; Pruden, A. Molecular survey of the occurrence of Legionella spp., Mycobacterium spp., Pseudomonas aeruginosa, and amoeba hosts in two chloraminated drinking water distribution systems. Appl. Environ. Microbiol. 2012, 78, 6285–6294. [Google Scholar] [CrossRef] [Green Version]
  40. Kao, P.M.; Tung, M.C.; Hsu, B.M.; Hsu, S.Y.; Huang, J.T.; Liu, J.H.; Huang, Y.L. Differential Legionella spp. survival between intracellular and extracellular forms in thermal spring environments. Environ. Sci. Pollut. Res. Int. 2013, 20, 3098–3106. [Google Scholar] [CrossRef]
  41. Boers, T.M.; Ben-Asher, J. A review of rainwater harvesting. Agric. Water Manag. 1982, 5, 145–158. [Google Scholar] [CrossRef]
  42. Dean, J.; Hunter, P.R. Risk of gastrointestinal illness associated with the consumption of rainwater: A systematic review. Environ. Sci. Technol. 2012, 46, 2501–2507. [Google Scholar] [CrossRef]
  43. Farhat, M.; Molletta-Denat, M.; Frère, J.; Onillon, S.; Trouilhé, M.C.; Robine, E. Effects of disinfection on Legionella spp., eukarya, and biofilms in a hot water system. Appl. Environ. Microbiol. 2012, 78, 6850–6858. [Google Scholar] [CrossRef] [Green Version]
  44. Centers for Disease Control and Prevention. Surveillance for waterborne disease outbreaks associated with drinking water and other nonrecreational water—United States, 2009–2010. MMWR Morb. Mortal. Wkly. Rep. 2013, 62, 714–720. [Google Scholar]
  45. Dutka, B.J.; Evans, P. Isolation of Legionella pneumophila from Canadian hot springs. Can. J. Public Health 1986, 77, 136–138. [Google Scholar] [PubMed]
  46. Mashiba, K.; Hamamoto, T.; Torikai, K. A case of Legionnaires’ disease due to aspiration of hot spring water and isolation of Legionella pneumophila from hot spring water. Kansenshogaku Zasshi 1993, 67, 163–166. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  47. Bornstein, N.; Marmet, D.; Surgot, M.; Nowicki, M.; Arslan, A.; Esteve, J.; Fleurette, J. Exposure to Legionellaceae at a hot spring spa: A prospective clinical and serological study. Epidem. Inf. 1989, 102, 31–36. [Google Scholar] [CrossRef] [Green Version]
  48. Riffard, S.; Douglass, S.; Brooks, T.; Springthorpe, S.; Filion, L.G.; Sattar, S.A. Occurrence of Legionella in groundwater: An ecological study. Water Sci. Technol. 2001, 43, 99–102. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  49. Brooks, T.; Osicki, R.; Springthorpe, V.; Sattar, S.; Filion, L.; Abrial, D.; Riffard, S. Detection and identification of Legionella species from groundwaters. J. Toxicol. Environ. Health A 2004, 67, 1845–1859. [Google Scholar] [CrossRef]
  50. Costa, J.; Tiago, I.; da Costa, M.S.; Veríssimo, A. Presence and persistence of Legionella spp. in groundwater. Appl. Environ. Microbiol. 2005, 71, 663–671. [Google Scholar] [CrossRef] [Green Version]
  51. Huang, S.W.; Hsu, B.M.; Chen, N.H.; Huang, C.C.; Huang, K.H.; Chen, J.S.; Kao, P.M. Isolation and identification of Legionella and their host amoebae from weak alkaline carbonate spring water using a culture method combined with PCR. Parasitol. Res. 2011, 109, 1233–1241. [Google Scholar] [CrossRef]
  52. Wullings, B.A.; Bakker, G.; van der Kooij, D. Concentration and diversity of uncultured Legionella spp. in two unchlorinated drinking water supplies with different concentrations of natural organic matter. Appl. Environ. Microbiol. 2011, 77, 634–644. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  53. Stojek, N.M.; Wójcik-Fatla, A.; Dutkiewicz, J. Efficacy of the detection of Legionella in hot and cold water samples by culture and PCR. II. Examination of native samples from various sources. Ann. Agric. Environ. Med. 2012, 19, 295–298. [Google Scholar]
  54. Furuhata, K.; Edagawa, A.; Ishizaki, N.; Fukuyama, M. Isolation of Legionella species from Noyu (unattended natural hot springs in mountains and fields) samples in Japan. Biocontrol. Sci. 2013, 18, 169–173. [Google Scholar] [CrossRef] [PubMed]
  55. Ghrairi, T.; Chaftar, N.; Jarraud, S.; Berjeaud, J.M.; Hani, K.; Frere, J. Diversity of legionellae strains from Tunisian hot spring water. Res. Microbiol. 2013, 164, 342–350. [Google Scholar] [CrossRef]
  56. Yan, G.B.; Wang, H.X.; Qin, T.; Zhou, H.J.; Li, M.C.; Xu, Y.; Zhao, M.Q.; Shao, Z.J.; Ren, H.Y. Three quantitative methods to continuously monitor Legionella in spring water. Zonghua Yu Fang Yi Xue Za Zhi 2013, 47, 637–640. [Google Scholar]
  57. Inoue, D.; Hinoura, T.; Suzuki, N.; Pang, J.; Malla, R.; Shrestha, S.; Chapagain, S.K.; Matsuzawa, H.; Nakamura, T.; Tanaka, Y.; et al. High-throughput DNA microarray detection of pathogenic bacteria in shallow well groundwater in the Kathmandu Valley, Nepal. Curr. Microbiol. 2015, 70, 43–50. [Google Scholar] [CrossRef]
  58. Shen, S.M.; Chou, M.Y.; Hsu, B.M.; Ji, W.T.; Hsu, T.K.; Tsai, H.F.; Huang, Y.L.; Chiu, Y.C.; Kao, E.S.; Kao, P.M.; et al. Assessment of Legionella pneumophila in recreational spring water with quantitative PCR (Taqman) assay. Pathog. Glob. Health 2015, 109, 236–241. [Google Scholar] [CrossRef] [Green Version]
  59. Ishizaki, N.; Sogawa, K.; Inoue, H.; Agata, K.; Edagawa, A.; Miyamoto, H.; Fukuyama, M.; Furuhata, K. Legionella thermalis sp. nov., isolated from hot spring water in Tokyo, Japan. Microbiol. Immunol. 2016, 60, 203–208. [Google Scholar] [CrossRef] [Green Version]
  60. Zhang, L.; Wang, X.; Shangguan, Z.; Zhou, H.; Wu, J.; Wan, L.; Ren, H.; Hu, Y.; Meifen, L.; Qin, T. High Prevalence and Genetic Polymorphisms of Legionella in Natural and Man-Made Aquatic Environments in Whenzhou, China. Int. J. Environ. Res. 2017, 14, 222. [Google Scholar] [CrossRef] [Green Version]
  61. De Giglio, O.; Napoli, C.; Apollonia, F.; Brigida, S.; Marzella, A.; Diella, G.; Calia, C.; Scrascia, M.; Pacifico, C.; Pazzani, C.; et al. Occurrence of Legionella in Groundwater used for sprinkler irrigation in Southern Italy. Environ. Res. 2019, 170, 215–221. [Google Scholar] [CrossRef] [PubMed]
  62. Ortiz-Roque, C.; Hazen, T.C. Legionellosis and Legionella spp. in the waters of Puerto Rico. Biol. Assoc. Med. PR 1983, 75, 403–407. [Google Scholar]
  63. Dutka, B.J. Sensitivity of Legionella pneumophila to sunlight in fresh and marine waters. Appl. Environ. Microbiol. 1984, 48, 970–974. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  64. Ortiz-Roque, C.M.; Hazen, T.C. Abundance and distribution of Legionellaceae in Puerto Rican Waters. Appl. Environ. Microbiol. 1987, 53, 2231–2236. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  65. Palmer, C.J.; Tsai, Y.L.; Paszko-Kolva, C.; Mayer, C.; Sangermano, L.R. Detection of Legionella species in sewage and ocean water by polymerase chain reaction, direct fluorescent-antibody, and plate culture methods. Appl. Environ. Microbiol. 1993, 59, 3618–3624. [Google Scholar] [CrossRef] [Green Version]
  66. Schäfer, H.; Servais, P.; Muyzer, G. Successional changes in the genetic diversity of a marine bacterial assemblage during confinement. Arch. Microbiol. 2000, 173, 138–145. [Google Scholar] [CrossRef]
  67. Chiou, S.F.; Kuo, J.; Wong, T.Y.; Fan, T.Y.; Tew, K.S.; Liu, J.K. Analysis of the coral associated bacterial community structures in healthy and diseased corals from off-shore of southern Taiwan. J. Environ. Sci. Health B 2010, 45, 408–415. [Google Scholar] [CrossRef] [PubMed]
  68. Gast, R.J.; Moran, D.M.; Dennett, M.R.; Wurtsbaugh, W.A.; Amaral-Zettler, L.A. Amoebae and Legionella pneumophila in saline environments. J. Water Health 2011, 9, 37–52. [Google Scholar] [CrossRef] [Green Version]
  69. Pagnier, I.; Boughalmi, M.; Croce, O.; Robert, C.; Raoult, D.; La Scola, B. Genome sequence of Legionella tunisiensis strain LegM(T), a new Legionella species isolated from hypersaline lake water. J. Bacteriol. 2012, 194, 5978. [Google Scholar] [CrossRef] [Green Version]
  70. Walczak, M.; Krawiec, A.; Lalke-Porczyk, E. Legionella pneumophila bacteria in thermal saline bath. Ann Agric. Environ. Med. 2013, 20, 649–652. [Google Scholar]
  71. Kilmer, B.R.; Eberl, T.C.; Cunderla, B.; Chen, F.; Clark, B.C.; Schneegurt, M.A. Molecular and phenetic characterization of the bacterial assemblage of Hot Lake, WA, an environment with high concentrations of magnesium sulfate, and its relevance to Mars. Int. J. Astrobiol. 2014, 13, 69–80. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  72. Manzari, C.; Fosso, B.; Marzano, M.; Annese, A.; Caprioli, R.; D’Erchia, A.M.; Gissi, C.; Intranuovo, M.; Picardi, E.; Santamaria, M.; et al. The influence of invasive jellyfish blooms on the aquatic microbiome in a coastal lagoon (Varano, SE Italy) detected by an Illumina-based deep sequencing strategy. Biol. Invasions 2015, 17, 923–940. [Google Scholar] [CrossRef] [Green Version]
  73. Tuyet, D.T.A.; Tanaka, T.; Sohrin, R.; Hao, D.M.; Nagaosa, K.; Kato, K. Effects of warming on microbial communities in the coastal waters of temperate and subtropical zones in the Northern Hemisphere, with a focus on Gammaproteobacteria. J. Oceanogr. 2015, 71, 91–103. [Google Scholar] [CrossRef]
  74. Leight, A.K.; Crump, B.C.; Hood, R.R. Assessment of Fecal Indicator Bacteria and Potential Pathogen Co-Occurrence at a Shellfish Growing Area. Front. Microbiol. 2018, 9, 384. [Google Scholar] [CrossRef] [Green Version]
  75. Jiang, S.C.; Han, M.; Chandrasekaran, S.; Fang, Y.; Kellogg, C.A. Assessing the water quality impacts of two Category-5 hurricanes on St. Thomas, Virgin Islands. Water Res. 2020, 171, 115440. [Google Scholar] [CrossRef]
  76. Fleming, L.E.; Broad, K.; Clement, A.; Dewailly, E.; Elmir, S.; Knap, A.; Pomponi, S.A.; Smith, S.; Solo Gabriele, H.; Walsh, P. Oceans and Human health: Emerging public health risks in the marine environment. Mar. Pollut. Bull. 2006, 53, 545–560. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  77. US EPA. Surface Water Treatment Rule; US EPA: Washington, DC, USA, 1989.
  78. Beer, K.D.; Gargano, J.W.; Roberts, V.A.; Reses, H.E.; Hill, V.R.; Garrison, L.E.; Kutty, P.K.; Hilborn, E.D.; Wade, T.J.; Fullerton, K.E.; et al. Outbreaks Associated With Environmental and Undetermined Water Exposures—United States, 2011–2012. MMWR Morb. Mortal. Wkly. Rep. 2015, 64, 849–851. [Google Scholar] [CrossRef] [Green Version]
  79. Schwartz, T.; Hoffman, S.; Obst, U. Formation of natural biofilms during chlorine dioxide and u.v. disinfection in a public drinking water distribution system. J. Appl. Microbiol. 2003, 95, 591–601. [Google Scholar] [CrossRef] [Green Version]
  80. Emtiazi, F.; Schwartz, T.; Marten, S.M.; Krolla-Sidenstein, P.; Obst, U. Investigation of natural biofilms formed during the production of drinking water from surface water embankment filtration. Water Res. 2004, 38, 1197–1206. [Google Scholar] [CrossRef] [PubMed]
  81. Pryor, M.; Springthorpe, S.; Riffard, S.; Brooks, T.; Huo, Y.; Davis, G.; Sattar, S.A. Investigation of opportunistic pathogens in municipal drinking water under different supply and treatment regimes. Water Sci. Technol. 2004, 50, 83–90. [Google Scholar] [CrossRef]
  82. Thomas, V.; Loret, J.F.; Jousset, M.; Greub, G. Biodiversity of amoebae and amoebae-resisting bacteria in a drinking water treatment plant. Environ. Microbiol. 2008, 10, 2728–2745. [Google Scholar] [CrossRef] [PubMed]
  83. Felföldi, T.; Tarnóczai, T.; Homonnay, Z.G. Presence of potential bacterial pathogens in a municipal drinking water supply system. Acta Microbiol. Immunol. Hung. 2010, 57, 165–179. [Google Scholar] [CrossRef]
  84. Valster, R.M.; Wullings, B.A.; van den Berg, R.; van der Kooij, D. Relationships between free-living protozoa, cultivable Legionella spp., and water quality characteristics in three drinking water supplies in the Caribbean. Appl. Environ. Microbiol. 2011, 77, 7321–7328. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  85. Baba, T.; Inoue, N.; Yamaguchi, N.; Nasu, M. Rapid enumeration of active Legionella pneumophila in freshwater environments by the microcolony method combined with direct fluorescent antibody staining. Microbes Environ. 2012, 27, 324–326. [Google Scholar] [CrossRef] [Green Version]
  86. Al-Sulami, A.A.; Al-Taee, A.M.; Yehyazarian, A.A. Isolation and identification of Legionella pneumophila from drinking water in Basra governorate, Iraq. East. Mediterr. Health J. 2013, 19, 936–941. [Google Scholar] [CrossRef]
  87. Donohue, M.J.; O’Connell, K.; Vesper, S.J.; Mistry, J.H.; King, D.; Kostich, M.; Pfaller, S. Widespread molecular detection of Legionella pneumophila serogroup 1 in cold water taps across the United States. Environ. Sci. Technol. 2014, 48, 3145–3152. [Google Scholar] [CrossRef] [PubMed]
  88. Whiley, H.; Keegan, A.; Fallowfield, H.; Bentham, R. Detection of Legionella, L. pneumophila, and Mycobacterium avium complex (MAC) along potable water distribution pipelines. Int. J. Environ. Res. Public Health 2014, 11, 7393–7405. [Google Scholar] [CrossRef] [Green Version]
  89. Sánchez-Busó, L.; Olmos, M.P.; Camaró, M.L.; Adrián, F.; Calafat, J.M.; González-Candelas, F. Phylogenetic analysis of environmental Legionella pneumophila isolates from an endemic area (Alcoy, Spain). Infect. Genet. Evol. 2015, 30, 45–54. [Google Scholar] [CrossRef]
  90. Schwake, D.O.; Alum, A.; Abbaszadegan, M. Impact of environmental factors on Legionella populations in drinking water. Pathogens 2015, 4, 269–282. [Google Scholar] [CrossRef] [Green Version]
  91. Waak, M.B.; LaPara, T.M.; Hallé, C.; Hozalski, R.M. Occurrence of Legionella spp. In Water-Main Biofilms from Two Drinking Water Distribution Systems. Environ. Sci. Technol. 2018, 52, 7630–7639. [Google Scholar] [CrossRef] [PubMed]
  92. Perrin, Y.; Bouchon, D.; Héchard, Y.; Moulin, L. Spatio-temporal survey of opportunistic premise plumbing pathogens in the Paris drinking water distribution system. Int. J. Hyg. Environ. Health 2019, 222, 687–694. [Google Scholar] [CrossRef] [PubMed]
  93. States, J.S.; Conley, L.F.; Kuchta, J.M.; Oleck, B.M.; Lipvich, M.J.; Wolford, R.S.; Wadowsky, R.M.; McNamara, A.M.; Sykora, J.L.; Keleti, G.; et al. Survival and Multiplication of Legionella pneumophila in municipal drinking water systems. Appl. Environ. Microbiol. 1987, 53, 979–986. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  94. Rhoads, W.J.; Garner, E.; Ji, P.; Zhu, N.; Parks, J.; Schwake, D.O.; Pruden, A.; Edwards, M.A. Distribution system operational deficiencies coincide with reported Legionnaires’ disease clusters in Flint, Michigan. Environ. Sci. Technol. 2017, 51, 11986–11995. [Google Scholar] [CrossRef] [PubMed]
Table 1. Occurrence of Legionella in Surface Freshwater.
Table 1. Occurrence of Legionella in Surface Freshwater.
Geographic Location% Positivity ConcentrationReference
USA: NC, SC, GA, FL, AL, IN, ILDFA: 99.5% samples, 98.5% sites9.1–3.3 × 104 cells/mL[17]
USA: CADFA: 100%,
PCR: 100%, Cul.: 25%
DFA: <0.1–>0.1 cells/mL
PCR: <103–103 cells/mL
[18]
NetherlandsPCR: 100%20–2.5 × 103 cells/mL[19]
Itanhaém River, Sao Paolo, BrazilCul.: 0%, PCR: 100%N/A[20]
Lake Pontchartrain, New Orleans, USAPCR: 72.9% samples, 100% sitesN/A[21]
Antarctica (King George Island)PCR: 100%, Cul.: 50%0.02 CFU/mL[22]
Auckland, New ZealandCul.: 15% Lp0.3–8 × 102 CFU/mL[23]
Tokyo, JapanCul.: 25%.
PCR: 60%
<0.2 CFU/mL–>10 CFU/mL[24]
Elbe River, Dresden, GermanyNAN/A[25]
Glomma River, NorwayCul.: 42.3% samples, 87.5% sites 40–1.9 × 103 CFU/mL[26]
Tech River, FranceCul.: 20.8%, PCR: 100% 0.05–0.583 CFU/mL.
7.39–936 GU/mL
[27]
Pyranees, FranceCul: 20.8%. PCR: 100%Cul.: 0.19–0.22 CFU/mL
PCR: 1.1–2 × 102 cells/mL
[28]
Lake Taihu, ChinaPCR: 65.6%NA[29]
Jiulong River, Fujian province, ChinaPCR: 100%<5 × 102–2.5 × 104 GU/mL[30]
Hubei Province, ChinaPCR: 100%Biofilm:10–103 GU/g.
Water: 30–100 GU/mL
[31]
Queensland, AustraliaPCR: 6%16–100 GU/mL[32]
East Cape Province, South AfricaPCR: 86%N/A[33]
Utrecht, NetherlandsCul.: 3.9%N/A[34]
Puzih river, TaiwanPCR: 63.1% Leg:, 7.7% Lp18–103 GU/mL[35]
TaiwanPCR: 35.5% samples, 78.9% reservoirs0.05–1.6 × 106 cells/mL[36]
South KoreaPCR: 100% sites, 14% samplesN/A[37]
AntarcticaPCR: 36.8%N/A[38]
DFA: direct fluorescent antibody microscopy, Cul.: cultivation techniques, N/A: no data available, Lp: Legionella pneumophila, Leg: Legionella spp.
Table 2. Occurrence of Legionella in Ground Freshwater.
Table 2. Occurrence of Legionella in Ground Freshwater.
Geographic Location% PositivityConcentration Reference
Savoie, FranceCul: NA1–100 CFU/mL [47]
USA: AL, FL, ID, IL, IN, MD, MI, MN, MT, NY, NC, OH, OR, TX, VT, WA, USAPCR: 94.8%, Cul.: 7% <44–>44 cells/mL[18]
USCul.: 100%Water: 0.1–840 CFU/mL. Biofilm: 2–267 CFU/cm2 [48]
USA: FL, AZ, TX, IL, MO, MI, NJ. Canada: Ontario, New BrunswickCul.: 33.3%. PCR: 24.1%.
Combined: 46% (58% water, 34.1% biofilm)
Cul: Water: 0.1–100 CFU/mL, Biofilm: 3–1.2 × 102 CFU/cm2[49]
Central PortugalCul.: Water: 58.6%, Well: 83.3%, Biofilm: 100%Water: 0.05–400 CFU/mL. Biofilm: 24–240 CFU/mL[50]
The NetherlandsPCR: Anaerobic Water: 42.9%, Aerobic Water: 88.9%Anaerobic: <0.2–2.4 cells/mL
Aerobic: <0.2–25 cells/mL
[19]
TaiwanCul.: Spring water: 33.3%, Hot tub/spa water: 33.3%N/A[51]
NetherlandsPCR: 60%, Cul.: 0% PCR: 0.076–0.39 cells/mL[52]
Southern TaiwanCul. and PCR: 38% N/A[40]
Eastern PolandCul.: 6.3%,
PCR: 62.5%
N/A[53]
JapanCul.: 37.2% samples,
72.7% prefectures
0.1–3 CFU/mL[54]
Northern TunisiaCul.: 22%.
PCR: 70.1%
Cul.: 0.1–8.2 CFU/mL.
PCR: 0.1–420 GU/mL
[55]
Beijing, ChinaCul.: 74.4%.
PCR: 100%.
EMA qPCR: 100%
Cul.: 0.1–216 CFU/mL.
PCR: 1.47–1557.75 GU/mL.
EMA qPCR: 0.2–301.69 GU/mL
[56]
Central and Southern TaiwanPCR: 47.5% Leg, 9.8% Lp14–170 GU/mL[35]
Kathmandu Valley, NepalPCR: 73%N/A[57]
TaiwanCul.: 93.8%Cul.: 72.1–5.7 × 106 CFU/mL[58]
Tokyo, JapanCul.: N/ACul.: N/A[59]
Wenzhou, ChinaPCR: 62.5%Cul: 0.2–107 CFU/mL[60]
Apulia Region, ItalyCul: 21.2%, PCR: 32.4%PCR: 0.263–2.87 × 103 GU/mL
Cul: 50 CFU/mL (maximum)
[61]
Cul.: cultivation techniques, N/A: no data available, SD: standard deviation, EMA qPCR: ethidium monoazide quantitative PCR, Lp: Legionella pneumophila, Leg: Legionella spp.
Table 3. Occurrence of Legionella in Saltwater.
Table 3. Occurrence of Legionella in Saltwater.
Geographic Location% PositivityConcentration Reference
Puerto RicoDFA: 100% Leg: 8.67 × 103–5.6 × 104 cells/mL,
Lp: 2.1 × 103–3.1 × 104 cells/mL
[64]
USACul.: 0%, PCR: 30%, DFA: 26.7%PCR: <103–>103 cells/mL.
DFA: 4–28 cells/mL
[65]
Gulf of Lyons, Mediterranean SeaPCR: 100%N/A[66]
Itanhaém River, Sao Paolo, BrazilCul.: 0%, PCR: 100%N/A[20]
3 coral reef sites; Southern Taiwan PCR: N/AN/A[67]
Mt Hope Bay, New England, and Great Salt Lake, UT, USAPCR: 88.6% soil samplesN/A[68]
Lake Sabka, TunisiaCul.: N/AN/A[69]
PolandDFA: 100%Leg: 1.98 × 103–3.2 × 104 cells/mL,
Lp: 70–4.85 × 103 cells/mL
[70]
Hot Lake, WA, USAPCR: N/AN/A[71]
Varano Lagoon, Adriatic coast. Apulia, ItalyPCR: 50% sampling sitesN/A[72]
Suruga Bay, Japan. Ha Long Bay, VietnamPCR: ≥30%N/A[73]
Oxford, Maryland, USAPCR: 100%>103 GU/mL (maximum)[74]
St. Thomas, Virgin IslandsPCR: 10%N/A[75]
DFA: direct fluorescent antibody microscopy, Leg: Legionella spp., Lp: Legionella pneumophila, Cul.: cultivation techniques, N/A: no data available.
Table 4. Occurrence of Legionella in Distribution System Drinking Water.
Table 4. Occurrence of Legionella in Distribution System Drinking Water.
Geographic Location% PositivityConcentration Reference
Central Europe PCR: 100% platelet materials, 87.5% sampling setsN/A[79]
Central Europe PCR: 100%N/A[80]
Pinellas County, Florida, USAPCR: 20% of select sites N/A[81]
Drinking Water Treatment Plant
Paris, France.
PCR: 29% samplesN/A[82]
HungaryPCR: 40% (Post chlorination 8%) N/A[83]
Leeward Antilles, Caribbean SeaPCR: 84%UV: 0.3–250 CFU/mL,
Cl: <0.25–65 CFU/mL
[84]
NetherlandsCul.: 0%. PCR: 100%
water, 93% biofilm
Water: 0.13–5.7 cells/mL, biofilm: 1.8–390 cells/cm2[52]
JapanCul.: 17%, MC-FA 28%Cul.: 0.1–12 CFU/mL. MC-FA: 0.02–19 micro CFU/mL[85]
Eastern PolandCul.: 0%. PCR: 7.4%N/A[53]
USA: FL and VAPCR: Water: 51.7% (4.8% Lp),
Biofilm: 34.6% (3.8% Lp)
Leg: 2.3 × 103 GU/mL water, 1.5 × 106 /swab biofilm.
Lp: 219.4 GU/mL water,
1.9 × 104 GU/swab biofilm
[39]
Basra, IraqCul.: WTP: 70%, DS: 100% sites,
Water tankers: 31.6%.
WTP: 10–5.6 × 104 CFU/mL,
DS: 20–400 CFU/mL
[86]
Hubei Province, ChinaPCR: 100% sampling sitesBiofilm: 10–3000 GU/g,
Water: 0.316–10 GU/mL
[31]
USA. 25 states PCR: 20% samples,
47% taps
0.04–3.65 × 102 GU/mL[87]
South Australia, AustraliaPCR: 100% sampling sitesCl: Leg: 3–1238 GU/mL, Lp: 3–1981 GU/mL.
Cla: Leg: 24–316,956 GU/mL, Lp: 3–3176 GU/mL
[88]
Alcoy, SpainCul.: 7.5% water,
21.6% biofilm
<0.04–0.45 CFU/mL[89]
Arizona, USACul.: 0%. PCR:
Leg: 13.4%, Lp: 7.5%
N/A[90]
US and NorwayPCR. biofilm: 0% cla, 43.47% no residual systemBiofilm: 7.8 × 104 GU/ cm2 (maximum)[91]
Paris, FrancePCR: 52.17% sampling sites>102 GU/mL (maximum)[92]
N/A: no data available, UV: ultraviolet light disinfection, Cl: chlorine disinfection, Cul.: cultivation techniques, MC-FA: micro-colony fluorescent antibody microscopy, Lp: Legionella pneumophila, Leg: Legionella spp., WTP: water treatment plant, DS: distribution system, Cla: chloramine disinfection.
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Share and Cite

MDPI and ACS Style

Schwake, D.O.; Alum, A.; Abbaszadegan, M. Legionella Occurrence beyond Cooling Towers and Premise Plumbing. Microorganisms 2021, 9, 2543. https://doi.org/10.3390/microorganisms9122543

AMA Style

Schwake DO, Alum A, Abbaszadegan M. Legionella Occurrence beyond Cooling Towers and Premise Plumbing. Microorganisms. 2021; 9(12):2543. https://doi.org/10.3390/microorganisms9122543

Chicago/Turabian Style

Schwake, David Otto, Absar Alum, and Morteza Abbaszadegan. 2021. "Legionella Occurrence beyond Cooling Towers and Premise Plumbing" Microorganisms 9, no. 12: 2543. https://doi.org/10.3390/microorganisms9122543

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop