Acquisition of Quasi-Monochromatic Dual-Energy in a Microfocus X-ray Generator and Development of Applied Technology

1
Department of Radiology, The University of Tokyo Hospital, Bunkyo-ku, Tokyo 113-8655, Japan
2
Department of Radiological Sciences, Faculty of Health Sciences, Komazawa University, Setagaya-ku, Tokyo 154-8525, Japan
*
Author to whom correspondence should be addressed.
Diagnostics 2019, 9(1), 27; https://doi.org/10.3390/diagnostics9010027
Received: 31 January 2019 / Revised: 27 February 2019 / Accepted: 27 February 2019 / Published: 4 March 2019
  |  
PDF [2181 KB, uploaded 4 March 2019]
  |  

Abstract

In regenerative medicine, evaluation of bone mineral density using a microfocus X-ray generator could eventually be used to determine the degree of bone tissue regeneration. To evaluate bone mineral density against regenerated bone material, two low-energy X-rays are necessary. Herein, the acquisition of quasi-monochromatic, dual-energy soft X-ray and the subsequent medical application were examined using the K-absorption edges of two types of metal filters (i.e., zirconium and tin) in a microfocus X-ray generator. Investigation of the optimal tube voltage and filter thickness to form a quasi-monochromatic energy spectrum with a single filter revealed that a filter thickness of 0.3 mm results in an optimal monochromatization state. When a dual filter was used, the required filter thickness was 0.3 mm for tin and 0.2 mm for zirconium at a tube voltage of 35 kV. For the medical application, we measured quasi-monochromatic, dual-energy X-rays to evaluate the measurement accuracy of bone mineral density. Using aluminum as a simulated bone sample, a relative error of ≤5% was consistent within the aluminum thickness range of 1–3 mm. These data suggest that a bone mineral density indicator of recycled bone material can be easily obtained with the quasi-monochromatic X-ray technique using a microfocus X-ray generator. View Full-Text
Keywords: microfocus X-ray generator; DEXA; K-absorption edge; dual-energy X-ray; bone mineral density microfocus X-ray generator; DEXA; K-absorption edge; dual-energy X-ray; bone mineral density
Figures

Figure 1

This is an open access article distributed under the Creative Commons Attribution License which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited (CC BY 4.0).
SciFeed

Share & Cite This Article

MDPI and ACS Style

Hasegawa, H.; Sato, M. Acquisition of Quasi-Monochromatic Dual-Energy in a Microfocus X-ray Generator and Development of Applied Technology. Diagnostics 2019, 9, 27.

Show more citation formats Show less citations formats

Note that from the first issue of 2016, MDPI journals use article numbers instead of page numbers. See further details here.

Related Articles

Article Metrics

Article Access Statistics

1

Comments

[Return to top]
Diagnostics EISSN 2075-4418 Published by MDPI AG, Basel, Switzerland RSS E-Mail Table of Contents Alert
Back to Top