Dose Descriptors and Assessment of Risk of Exposure-Induced Death in Patients Undergoing COVID-19 Related Chest Computed Tomography
Abstract
1. Introduction
2. Materials and Methods
3. Results
4. Discussion
5. Conclusions
Author Contributions
Funding
Institutional Review Board Statement
Informed Consent Statement
Data Availability Statement
Conflicts of Interest
References
- Ciotti, M.; Angeletti, S.; Minieri, M.; Giovannetti, M.; Benvenuto, D.; Pascarella, S.; Sagnelli, C.; Bianchi, M.; Bernardini, S.; Ciccozzi, M. COVID-19 outbreak: An overview. Chemotherapy 2019, 64, 215–223. [Google Scholar] [CrossRef]
- Daga, M.K.; Kumar, N.; Aarthi, J.; Mawari, G.; Garg, S.; Rohatgi, I. From SARS-CoV to coronavirus disease 2019 (COVID-19)—A brief review. J. Adv. Res. Med. 2019, 6, 1–9. [Google Scholar] [CrossRef]
- Chalkia, M.; Arkoudis, N.A.; Maragkoudakis, E.; Rallis, S.; Tremi, I.; Georgakilas, A.G.; Kouloulias, V.; Efstathopoulos, E.; Platoni, K. The Role of Ionizing Radiation for Diagnosis and Treatment against COVID-19: Evidence and Considerations. Cell 2022, 11, 467. [Google Scholar] [CrossRef] [PubMed]
- Zheng, M.; Gao, Y.; Wang, G.; Song, G.; Liu, S.; Sun, D.; Xu, Y.; Tian, Z. Functional exhaustion of antiviral lymphocytes in COVID-19 patients. Cell. Mol. Immunol. 2020, 17, 533–535. [Google Scholar] [CrossRef] [PubMed]
- Yuki, K.; Fujiogi, M.; Koutsogiannaki, S. COVID-19 pathophysiology: A review. Clin. Immunol. 2020, 215, 108427. [Google Scholar] [CrossRef]
- Arapović, J.; Skočibušić, S. The first two months of the COVID-19 pandemic in Bosnia and Herzegovina: Single-center experience. Bosn. J. Basic Med. Sci. 2020, 20, 396–400. [Google Scholar] [CrossRef]
- Dyer, O. Covid-19: Lockdowns spread in China as omicron tests “zero covid” strategy. BMJ 2022, 376, o859. [Google Scholar] [CrossRef]
- Abeysuriya, R.G.; Delport, D.; Stuart, R.M.; Sacks-Davis, R.; Kerr, C.C.; Mistry, D.; Klein, D.J.; Hellard, M.; Scott, N. Preventing a cluster from becoming a new wave in settings with zero community COVID-19 cases. BMC Infect. Dis. 2022, 22, 232. [Google Scholar] [CrossRef]
- Kalra, M.K.; Homayounieh, F.; Arru, C.; Holmberg, O.; Vassileva, J. Chest CT practice and protocols for COVID-19 from radiation dose management perspective. Eur. Radiol. 2020, 30, 6554–6560. [Google Scholar] [CrossRef]
- Homayounieh, F.; Holmberg, O.; Umairi, R.A.; Aly, S.; Basevičius, A.; Costa, P.R.; Darweesh, A.; Gershan, V.; Ilves, P.; Kostova-Lefterova, D.; et al. Variations in CT utilization, protocols, and radiation doses in COVID-19 pneumonia: Results from 28 countries in the IAEA Study. Radiology 2021, 298, E141–E151. [Google Scholar] [CrossRef]
- Herpe, G.; Lederlin, M.; Naudin, M.; Ohana, M.; Chaumoitre, K.; Gregory, J.; Vilgrain, V.; Freitag, C.A.; De Margerie-Mellon, C.; Flory, V.; et al. Efficacy of Chest CT for COVID-19 Pneumonia Diagnosis in France. Radiology 2021, 298, E81–E87. [Google Scholar] [CrossRef] [PubMed]
- Borakati, A.; Perera, A.; Johnson, J.; Sood, T. Diagnostic accuracy of X-ray versus CT in COVID-19: A propensity-matched database study. BMJ Open 2020, 10, e042946. [Google Scholar] [CrossRef] [PubMed]
- Sodickson, A.; Baeyens, P.F.; Andriole, K.P.; Prevedello, L.M.; Nawfel, R.D.; Hanson, R.; Khorasani, R. Recurrent CT, cumulative radiation exposure, and associated radiation-induced cancer risks from CT of adults. Radiology 2009, 251, 175–184. [Google Scholar] [CrossRef] [PubMed]
- Rubin, G.D.; Ryerson, C.J.; Haramati, L.B.; Sverzellati, N.; Kanne, J.P.; Raoof, S.; Schluger, N.W.; Volpi, A.; Yim, J.J.; Martin, I.B.; et al. The role of chest imaging in patient management during the COVID-19 pandemic: A multinational consensus statement from the Fleischner Society. Radiology 2020, 296, 172–180. [Google Scholar] [CrossRef]
- Aubert, B.; Biau, A.; Derreumaux, S.; Etard, C.; Rannou, A.; Rehel, J.L. ICRP Publication 105. Radiological Protection in Medicine; Publication 105 de la CIPR. Protection radiologique en medecine; Elsevier Ltd.: Oxiord, UK, 2011. [Google Scholar]
- Valentin, J. ICRP Publication 102; Managing patient dose in multi-detector computed tomography (MDCT). Ann. ICRP 2007, 37, 1–79. [Google Scholar]
- Pernicka, F.; McLean, I.D. Dosimetry in Diagnostic Radiology: An International Code of Practice; Number 457 in Technical Reports Series; International Atomic Energy Agency: Vienna, Austria, 2007. [Google Scholar]
- Fisher, D.R.; Fahey, F.H. Appropriate use of effective dose in radiation protection and risk assessment. Health Phys. 2017, 113, 102–109. [Google Scholar] [CrossRef]
- Menzel, H.; Harrison, J. Effective dose: A radiation protection quantity. Ann. ICRP 2012, 41, 117–123. [Google Scholar] [CrossRef]
- Valentin, J. The 2007 Recommendations of the International Commission on Radiological Protection; ICRP publication 103; Elsevier: Amsterdam, The Netherlands, 2007; Volume 37, pp. 1–332. [Google Scholar]
- Paul, J.; Banckwitz, R.; Krauss, B.; Vogl, T.J.; Maentele, W.; Bauer, R.W. Estimation and comparison of effective dose (E) in standard chest CT by organ dose measurements and dose-length-product methods and assessment of the influence of CT tube potential (energy dependency) on effective dose in a dual-source CT. Eur. J. Radiol. 2012, 81, e507–e512. [Google Scholar] [CrossRef]
- Christner, J.A.; Kofler, J.M.; McCollough, C.H. Estimating effective dose for CT using dose–length product compared with using organ doses: Consequences of adopting International Commission on Radiological Protection Publication 103 or dual-energy scanning. Am. J. Roentgenol. 2010, 194, 881–889. [Google Scholar] [CrossRef]
- Lin, E.C. Radiation Risk From Medical Imaging. Mayo Clin. Proc. 2010, 85, 1142–1146. [Google Scholar] [CrossRef] [PubMed]
- Mettler, F.A.J.; Huda, W.; Yoshizumi, T.T.; Mahesh, M. Effective doses in radiology and diagnostic nuclear medicine: A catalog. Radiology 2008, 248, 254–263. [Google Scholar] [CrossRef] [PubMed]
- Shi, H.M.; Sun, Z.C.; Ju, F.H. Understanding the harm of low-dose computed tomography radiation to the body (Review). Exp. Ther. Med. 2022, 24, 534. [Google Scholar] [CrossRef]
- Masjedi, H.; Omidi, R.; Zamani, H.; Perota, G.; Zare, M.H. Radiation dose and risk of exposure-induced death associated with common computed tomography procedures in Yazd Province. Eur. J. Radiol. 2020, 126, 108932. [Google Scholar] [CrossRef] [PubMed]
- Fehrmann, M.; Schegerer, A.; Werncke, T.; Schlattl, H. Comparison of Experimental and Numerical Methods of Patient dose Estimations in CT Using Anthropomorphic Models. Radiat. Prot. Dosim. 2020, 190, 71–83. [Google Scholar] [CrossRef]
- Servomaa, A.; Tapiovaara, M. Organ Dose Calculation in Medical X Ray Examinations by the Program PCXMC. Radiat. Prot. Dosim. 1998, 80, 213–219. [Google Scholar] [CrossRef]
- National Research Council. Health Risks from Exposure to Low Levels of Ionizing Radiation: BEIR VII Phase 2; National Academies Press: Washington, DC, USA, 2006. [Google Scholar]
- Kutanzi, K.R.; Lumen, A.; Koturbash, I.; Miousse, I.R. Pediatric exposures to ionizing radiation: Carcinogenic considerations. Int. J. Environ. Res. Public Health 2016, 13, 1057. [Google Scholar] [CrossRef]
- Sakane, H.; Ishida, M.; Shi, L.; Fukumoto, W.; Sakai, C.; Miyata, Y.; Ishida, T.; Akita, T.; Okada, M.; Awai, K.; et al. Biological effects of low-dose chest CT on chromosomal DNA. Radiology 2020, 295, 439–445. [Google Scholar] [CrossRef]
- Cristofaro, M.; Fusco, N.; Petrone, A.; Albarello, F.; Di Stefano, F.; Pianura, E.; Schininà, V.; Ianniello, S.; Campioni, P. Increased Radiation Dose Exposure in Thoracic Computed Tomography in Patients with Covid-19. Radiation 2021, 1, 153–161. [Google Scholar] [CrossRef]
- Peng, Y.; Li, J.; Ma, D.; Zhang, Q.; Liu, Y.; Zeng, J.; Sun, G. Use of automatic tube current modulation with a standardized noise index in young children undergoing chest computed tomography scans with 64-slice multidetector computed tomography. Acta Radiol. 2009, 50, 1175–1181. [Google Scholar] [CrossRef]
- Steuwe, A.; Rademacher, C.; Valentin, B.; Köhler, M.H.; Appel, E.; Keitel, V.; Timm, J.; Antoch, G.; Aissa, J. Dose-optimised chest computed tomography for diagnosis of Coronavirus Disease 2019 (COVID-19)–Evaluation of image quality and diagnostic impact. J. Radiol. Prot. 2020, 40, 877–891. [Google Scholar] [CrossRef] [PubMed]
- Pan, F.; Ye, T.; Sun, P.; Gui, S.; Liang, B.; Li, L.; Zheng, D.; Wang, J.; Hesketh, R.L.; Yang, L.; et al. Time course of lung changes at chest CT during recovery from coronavirus disease 2019 (COVID-19). Radiology 2020, 295, 715–721. [Google Scholar] [CrossRef] [PubMed]
- Bernardo, M.; Homayounieh, F.; Rodel Cuter, M.C.; Bellegard, L.M.; Oliveira Junior, H.M.; Buril, G.O.; de Melo Tapajós, J.S.; Sales, D.M.; de Moura Carvalho, L.C.; Pinto, D.A.; et al. Chest CT usage in COVID-19 pneumonia: Multicenter study on radiation doses and diagnostic quality in Brazil. Rad. Prot. Dosim. 2021, 197, 135–145. [Google Scholar] [CrossRef] [PubMed]
- Liu, D.; Li, L.; Wu, X.; Zheng, D.; Wang, J.; Liang, B.; Yang, L.; Zheng, C. Pregnancy and perinatal outcomes of women with COVID-19 pneumonia: A preliminary analysis. Am. J. Roentgenol. 2020, 215, 127–132. [Google Scholar] [CrossRef] [PubMed]
- Zhou, Y.; Zheng, Y.; Wen, Y.; Dai, X.; Liu, W.; Gong, Q.; Huang, C.; Lv, F.; Wu, J. Radiation dose levels in chest computed tomography scans of coronavirus disease 2019 pneumonia: A survey of 2119 patients in Chongqing, southwest China. Medicine 2021, 100, e26692. [Google Scholar] [CrossRef] [PubMed]
- Karakaş, H.M.; Yıldırım, G.; Çiçek, E.D. The reliability of low-dose chest CT for the initial imaging of COVID-19: Comparison of structured findings, categorical diagnoses and dose levels. Diagn. Interv. Radiol. 2021, 27, 607–614. [Google Scholar] [CrossRef]
- Schulze-Hagen, M.; Hübel, C.; Meier-Schroers, M.; Yüksel, C.; Sander, A.; Sähn, M.; Kleines, M.; Isfort, P.; Cornelissen, C.; Lemmen, S.; et al. Low-Dose Chest CT for the Diagnosis of COVID-19: A Systematic, Prospective Comparison With PCR. Dtsch. Arzteb. Int. 2020, 117, 389–395. [Google Scholar]
- Castelli, M.; Maurin, A.; Bartoli, A.; Dassa, M.; Marchi, B.; Finance, J.; Lagier, J.C.; Million, M.; Parola, P.; Brouqui, P.; et al. Prevalence and risk factors for lung involvement on low-dose chest CT (LDCT) in a paucisymptomatic population of 247 patients affected by COVID-19. Insights Imaging 2020, 11, 117. [Google Scholar] [CrossRef]
- Agostini, A.; Floridi, C.; Borgheresi, A.; Badaloni, M.; Pirani, P.E.; Terilli, F.; Ottaviani, L.; Giovagnoni, A. Proposal of a low-dose, long-pitch, dual-source chest CT protocol on third-generation dual-source CT using a tin filter for spectral shaping at 100 kVp for CoronaVirus Disease 2019 (COVID-19) patients: A feasibility study. Radiol. Med. 2020, 125, 365–373. [Google Scholar] [CrossRef]
- Tawk, S.; Mansour, W.; Sleiman, D.; Gemayel, S.; Lozom, E.; El Mendelek, K.; Saliba, N.; Mourad, C. Submillisievert CT chest for COVID-19 patients in a rural hospital with limited resources. Egypt. J. Radiol. Nucl. Med. 2022, 53, 61. [Google Scholar] [CrossRef]
- Vañó, E.; Miller, D.; Martin, C.; Rehani, M.; Kang, K.; Rosenstein, M.; Ortiz-López, P.; Mattsson, S.; Padovani, R.; Rogers, A. ICRP publication 135: Diagnostic reference levels in medical imaging. Ann. ICRP 2017, 46, 1–144. [Google Scholar] [CrossRef] [PubMed]
- European Commission. Diagnostic Reference Levels in Thirty-Six European Countries; European Union: Luxembourg, 2014. [Google Scholar]
- Dangis, A.; Gieraerts, C.; De Bruecker, Y.; Janssen, L.; Valgaeren, H.; Obbels, D.; Gillis, M.; Van Ranst, M.; Frans, J.; Demeyere, A.; et al. Accuracy and reproducibility of low-dose submillisievert chest CT for the diagnosis of COVID-19. Radiol. Cardiothorac. Imaging 2020, 2, e200196. [Google Scholar] [CrossRef] [PubMed]
- Bistaraki, A.; Roussos, S.; Tsiodras, S.; Sypsa, V. Age-dependent effects on infectivity and susceptibility to SARS-CoV-2 infection: Results from nationwide contact tracing data in Greece. Infect. Dis. 2022, 54, 186–195. [Google Scholar] [CrossRef]
- Davies, N.G.; Klepac, P.; Liu, Y.; Prem, K.; Jit, M.; Eggo, R.M. Age-dependent effects in the transmission and control of COVID-19 epidemics. Nat. Med. 2020, 26, 1205–1211. [Google Scholar] [CrossRef]
- Lee, C. Managing radiation dose from chest CT in patients with COVID-19. Radiology 2021, 298, E158–E159. [Google Scholar] [CrossRef]
- Albert, J.M. Radiation risk from CT: Implications for cancer screening. Am. J. Roentgenol. 2013, 201, W81–W87. [Google Scholar] [CrossRef] [PubMed]
- Khan, M.G.M.; Wang, Y. Advances in the Current Understanding of How Low-Dose Radiation Affects the Cell Cycle. Cells 2022, 11, 356. [Google Scholar] [CrossRef] [PubMed]
- Schultz, C.H.; Fairley, R.; Murphy, L.S.L.; Doss, M. The risk of cancer from CT scans and other sources of low-dose radiation: A critical appraisal of methodologic quality. Prehosp. Disaster Med. 2020, 35, 3–16. [Google Scholar] [CrossRef]
- Shah, D.J.; Sachs, R.K.; Wilson, D.J. Radiation-induced cancer: A modern view. Br. J. Radiol. 2012, 85, e1166–e1173. [Google Scholar] [CrossRef]
- Chaparian, A.; Zarchi, H.K. Assessment of radiation-induced cancer risk to patients undergoing computed tomography angiography scans. Int. J. Radiat. Res. 2018, 16, 107–115. [Google Scholar]
- Karimizarchi, H.; Chaparian, A. Estimating risk of exposure induced cancer death in patients undergoing computed tomography pulmonary angiography. Radioprotection 2017, 52, 81–86. [Google Scholar] [CrossRef]
- Karambatsakidou, A.; Steiner, K.; Fransson, A.; Poludniowski, G. Age-specific and gender-specific radiation risks in paediatric angiography and interventional cardiology: Conversion coefficients and risk reference values. Br. J. Radiol. 2020, 93, 20190869. [Google Scholar] [CrossRef] [PubMed]



| CTDIvol (mGy) | DLP (mGy cm) | ||||||||
|---|---|---|---|---|---|---|---|---|---|
| Male | Female | Male | Female | ||||||
| Age group | <40.0 | 3.1 | 3.0 | 2.4 | 0.75 | 165 | 123 | 136 | 46 |
| 40.0–64.9 | 3.2 | 2.2 | 2.7 | 1.9 | 172 | 105 | 149 | 90 | |
| ≥65.0 | 2.7 | 1.7 | 2.6 | 1.5 | 157 | 75.8 | 146 | 64 | |
| Total | 3.0 | 1.9 | 2.6 | 1.5 | 164 | 92.1 | 147 | 71 | |
| E (mSv) | |||||||
|---|---|---|---|---|---|---|---|
| Male | Female | Total | |||||
| Age group | <40.0 | 2.7 | 2.6 | 2.4 | 0.6 | 2.6 | 1.8 |
| 40.0–64.9 | 2.9 | 2.0 | 2.7 | 1.9 | 2.8 | 1.9 | |
| ≥65.0 | 2.4 | 1.5 | 2.6 | 1.5 | 2.5 | 1.4 | |
| Total | 2.7 | 1.7 | 2.6 | 1.5 | 2.6 | 1.5 | |
| Mean REID Values (per Million) | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| Age | Sex | Leukemia | Breast | Colon | Liver | Lung | Ovary | Stomach | Bladder | Total |
| <40.0 | M | 12.8 | - | 27.1 | 9.1 | 42.3 | - | 13.4 | 0.4 | 105.1 |
| F | 9.4 | 29.3 | 3.9 | 6.4 | 92.5 | 0.1 | 19.1 | 0.1 | 160.9 | |
| 40.0–64.9 | M | 13.8 | - | 23.2 | 7.6 | 38.1 | - | 11.5 | 0.4 | 94.5 |
| F | 11.7 | 9.5 | 3.8 | 6.2 | 92.9 | 0.1 | 18.6 | 0.1 | 142.9 | |
| ≥65.0 | M | 12.4 | - | 15.3 | 4.4 | 27.0 | - | 7.3 | 0.4 | 66.7 |
| F | 10.1 | 2.3 | 2.5 | 3.7 | 59.6 | 0.0 | 12.0 | 0.1 | 89.6 | |
| Total | M | 13.1 | - | 20.1 | 6.3 | 33.6 | - | 9.8 | 0.4 | 83.3 |
| F | 10.7 | 7.2 | 3.1 | 4.9 | 75.4 | 0.1 | 15.2 | 0.1 | 116.3 | |
| TOTAL | 12.1 | 7.2 | 13.5 | 5.8 | 49.9 | 0.1 | 11.9 | 0.3 | 96.1 | |
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations. |
© 2022 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
Share and Cite
Čiva, L.M.; Beganović, A.; Busuladžić, M.; Jusufbegović, M.; Awad-Dedić, T.; Vegar-Zubović, S. Dose Descriptors and Assessment of Risk of Exposure-Induced Death in Patients Undergoing COVID-19 Related Chest Computed Tomography. Diagnostics 2022, 12, 2012. https://doi.org/10.3390/diagnostics12082012
Čiva LM, Beganović A, Busuladžić M, Jusufbegović M, Awad-Dedić T, Vegar-Zubović S. Dose Descriptors and Assessment of Risk of Exposure-Induced Death in Patients Undergoing COVID-19 Related Chest Computed Tomography. Diagnostics. 2022; 12(8):2012. https://doi.org/10.3390/diagnostics12082012
Chicago/Turabian StyleČiva, Lejla M., Adnan Beganović, Mustafa Busuladžić, Merim Jusufbegović, Ta’a Awad-Dedić, and Sandra Vegar-Zubović. 2022. "Dose Descriptors and Assessment of Risk of Exposure-Induced Death in Patients Undergoing COVID-19 Related Chest Computed Tomography" Diagnostics 12, no. 8: 2012. https://doi.org/10.3390/diagnostics12082012
APA StyleČiva, L. M., Beganović, A., Busuladžić, M., Jusufbegović, M., Awad-Dedić, T., & Vegar-Zubović, S. (2022). Dose Descriptors and Assessment of Risk of Exposure-Induced Death in Patients Undergoing COVID-19 Related Chest Computed Tomography. Diagnostics, 12(8), 2012. https://doi.org/10.3390/diagnostics12082012

