Abstract
Background and Objectives: Cardiac function in patients with Parkinson’s Disease (PD) is not well understood. We conducted a review of the literature to summarize all available data on the cardiac cycle in patients with PD and followed up the review with a case series to describe the cardiac cycle timing intervals in this patient population. Methods: Using the search terms (“Cardiac cycle” OR “echocardiography” OR “LVET” OR “IVCT” OR “IVRT” OR “LVEF” OR “Systolic Dysfunction” OR “Diastolic Dysfunction”) AND (“Parkinson’s Disease”), 514 studies were found with 19 included in the review. Results: Studies focused on the impact of medication, the presence of autonomic dysfunction, and resting-state, descriptive observational studies which considered the cardiac cycle. While inconsistent, the evidence suggests that patients with PD have some systolic dysfunction, with recent research implying the presence of subclinical systolic dysfunction. From the case series, 13 participants with PD were included and collected cardiac data daily for 6 weeks. Heart rate was consistent on a weekly basis at 67–71 bpm. Mean week-by-week cardiac parameters were also consistent with the systolic time interval at 332–348 ms, isovolumic relaxation time at 92–96 ms, and isovolumic contraction time at 34–36 ms. Conclusion: These timing intervals add valuable normative values for this patient population and the review of the literature suggests that more research is required to better understand cardiac cycle timing intervals in patients with Parkinson’s Disease.
1. Introduction
Parkinson’s Disease (PD) is prevalent in 0.2% of private households and 4.9% of residential areas in Canada [1]. Pharmaceutical interventions and exercise have gained interest and research, garnering these approaches as potential therapeutics. Recently, there has been growing evidence of impairments in sleep function in patients with PD as compared to controls [2]. From 157 patients with PD, with 95 at the early stage and 62 with late-stage PD, it was found that both groups had impaired sleep parameters, including sleep efficiency, wake after sleep onset and total sleep time as compared to controls when measured by actigraphy [3].
While sleep is better understood now in PD, there is still a need to understand how cardiac function is affected in PD. Indeed, using echocardiography, PD patients have shown reduced global longitudinal strain and ejection fraction, along with elevated left ventricular end-diastolic and systolic dimensions [4]. The authors state there does appear to be subclinical left ventricular systolic dysfunction in PD patients, which does correlate with cognitive impairment [4]. Heart rate variability (HRV) is a commonly used technique for the assessment of autonomic function, with depressed HRV in patients with PD [5]. However, HRV is generally associated with measures of sympathetic and parasympathetic tone [6], with the findings more consistent with inflammation and stress [6,7], and can be limited when attempting to understand the cardiac cycle. To understand the mechanism associated with cardiac changes in PD, there must be an emphasis on understanding changes associated with the cardiac cycle timing intervals. We conducted a literature review on the cardiac cycle parameters in PD patients and provided a proof-of-concept case series describing the cardiac cycle in a cohort of both exercising and non-exercising PD patients.
2. Materials and Methods
2.1. Literature Review
A literature review was conducted to understand the findings of cardiac cycle intervals in PD. PubMed (including MEDLINE) was searched from the first available article to June 1, 2022, using the search terms (“Cardiac cycle” OR “echocardiography” OR “LVET” OR “IVCT” OR “IVRT” OR “LVEF” OR “Systolic Dysfunction” OR “Diastolic Dysfunction”) AND (“Parkinson’s Disease”) for peer-reviewed studies published in English. This search yielded 514 articles. After the removal of articles that did not include PD patients, 356 remained. Two-hundred and two articles that did not include cardiac cycle data, and 135 articles that were either not in English, or did not include humans, case reports, reviews, books, or retractions were also removed. This resulted in 19 articles that were included in our analyses (Figure 1).
Figure 1.
Flowchart of article exclusion for review.
2.2. Case Series Methods
This study was approved by the University of Regina research ethics board (REB-2020-152). Eighteen participants were recruited. All participants read and signed an informed consent form prior to beginning the study. Participants completed a Montreal Cognitive Assessment (MoCA) and were required to score ≥23 to proceed with the study. Participants were given an actigraph (Phillips Respironics, Actiwatch) and wore the watch at least 1 h before going to sleep and for 1 h after getting out of bed. Participants were given a cardiac sensor (RecordisTM, LLA Technologies, Langley, BC, Canada) and collected their cardiac data for 1 min every morning. Participants were told to rest in a supine position for 1 min and placed the sensor on their sternum. The sensor was turned on for 1 min and recorded the cardiac vibrations [8,9,10,11]. Data were collected for 6 weeks. Exercisers completed a minimum of 150 min/week of exercise on their own or by involvement in an online exercise program. Sleep data were assessed using the Phillips Actiware software. Their algorithm allows for the computation of sleep metrics, with our focus being sleep efficiency, calculated as the time spent sleeping/total time spent in bed.
As stated by [8,9,10,11], data analysis of the fiducial points of the cardiac cycle included the mitral valve closure (MVC), aortic valve opening (AVO), aortic valve closure (AVC), mitral valve opening (MVO), and twist force (TF). After the extraction of morphological features, temporal features were calculated (milliseconds, ms). This included diastole (MVC—MVO timing), systole (AVO—AVC timing), isovolumic contraction time [IVCT (MVC—AVO)], isovolumic relaxation time [IVRT (AVC—MVO)] and heart rate (AVOn + 1—AVOn). Performance indices were calculated as [12]:
- -
- Diastolic performance index: DPI = IVRT/Ejection time
- -
- Systolic performance index: SPI = IVCT/Ejection time
- -
- Heart (or myocardial index) performance index: HPI (or MPI) = (IVCT + IVRT)/Ejection time
Due to the small sample size, descriptive statistics are presented as mean ± standard deviation. Percent (%) changes show differences in exercisers compared to non-exercisers on a week-by-week basis.
3. Results
3.1. Review Results
The findings of the studies included in the review are summarized in Table 1.
3.1.1. Baseline Observational Studies
Using 2D speckle tracking echocardiography, decreases in LVEF and global longitudinal strain and increases in left ventricular end-diastolic and systolic dimensions were found in patients with PD as compared to controls under resting conditions [4]. These speckle-tracking strain changes imply that subtle myocardial deformations and subclinical systolic dysfunction may be present in patients with PD. Another study observed cardiac changes against healthy controls and found elevated stroke volume index, ventricular and atrial mass, and filling pressures as defined by the E/e’ ratio. Furthermore, these findings implied a greater prevalence of diastolic dysfunction and with the MPI at 0.4, there is a suggestion of altered timing intervals (IVRT, IVCT and ejection time) for the PD patients [13]. Only one study assessed atrial conduction times, with results suggesting that PD patients exhibit prolonged interatrial, and right and left intra-atrial electromechanical delay, and this prolongation is associated with disease severity [14]. These prolonged atrial conduction timing intervals can further imply that left ventricular intervals may also be prolonged.
3.1.2. Autonomic Dysfunction
Utilizing 2D transthoracic echocardiography, it was found that PD patients with difficulties associated with blood pressure regulation (“reverse dipping”) have altered cardiac function in comparison to those with hypertension, as shown by PD patients having increased LV volume, LV mass, signs of LV hypertrophy, and signs of decreased LV filling pressure [15]. Building on autonomic dysfunction in PD patients, separating patients into those with a vasodilation or vasoconstriction response to a 70-degree head up tilt test found that the PD patients with a vasodilation response showed elevated total peripheral resistance and lower stroke volume and cardiac output when compared to vasoconstrictors and healthy controls [16]. In PD patients without neurogenic orthostatic hypotension, no altered cardiac cycle intervals were found to be associated with any PD severity demographics [17], and PD patients who had suffered from HF showed no differences in LVEF compared to PD patients who did not [18].
3.1.3. Impact of Medication
When comparing PD patients on different medications given in their early or late-stage PD, one study found that when assessing cardiac function using speckle-tracking echocardiography, there are no differences between any of the groups when observing strain parameters [19]. Indeed, drug-naïve PD patients showed no differences in echocardiography parameters when compared to healthy controls [20].
Limited research is available on interventions and the cardiac cycle; however, of the available data, exercise training such as coordination and manipulation therapy has been shown to increase LVEF in PD patients at 6 and 12-month follow-ups [21]. Another intervention observed cardiac changes in PD patients undergoing L-dopa/dopa decarboxylase inhibitor therapy in comparison to healthy controls, with results showing no differences in strain parameters or LVEF [22]. However, a decrease in the E/A ratio, a common marker of LV diastolic function, was found in PD patients [22]. An observational assessment of PD patients using cabergoline found that the E/A ratio and deceleration time of the ventricle is associated with cumulative cabergoline dose [23]. While ergot-derived dopamine agonists are known to induce a risk of valvular dysfunction, no differences were seen in the cardiac cycle parameters, including strain parameters or LVEF, thus implying that there are no differences in myocardial systolic or diastolic function between groups [24]. Even when treated with ergot-derived dopamine agonists for 6 months, no differences in LVEF are prominent [25]. The use of pergolide or cabergoline also does not seem to alter LVEF [26]. The systolic time interval has been shown to be elevated in PD patients following a stimulus such as an exercise in comparison to healthy, younger subjects (20 ± 2 years), and altered pre-ejection time period dynamics were found in PD in multiple studies [27,28], including after tyramine injection [29] and Levodopa therapy [30].
Given these findings, there is a requirement for research focusing on describing the cardiac cycle intervals in PD patients. Furthermore, these cardiac studies do not include any information on the PD patients’ sleep quality.
Table 1.
Summary of Cardiac Cycle findings in Parkinson’s Disease.
3.2. Case Series Results
Of the 18 participants recruited, 13 completed the 6-week data collection. The demographics are presented in Table 2.
Table 2.
Demographic details of participants included in case series.
Heart rate was consistent on a weekly basis at 67–71 bpm. Mean week-by-week cardiac parameters were also consistent with systole at 332–348 ms, IVRT at 92–96 ms, IVCT at 34–36 ms, SPI at 0.10–0.11, DPI at 0.27–0.29, HPI (MPI) at 0.37–0.40, and cardiac TF at 12–14 mG.
Six exercisers and seven non-exercisers were included. Weekly means and % changes for cardiac parameters are presented in Table 3. Cardiac parameters were consistent for exercisers with systole at 342–353 ms, IVRT at 94–98 ms, IVCT at 34–37 ms, SPI at 0.10–0.11, DPI at 0.28 to 0.29, HPI at 0.38–0.40, and TF at 11–13 mG on a weekly basis.
Table 3.
Weekly changes in primary cardiac cycle parameters in exercisers and non-exercisers.
For non-exercisers, cardiac parameters were also consistent week-by-week with systole at 321–348 ms, IVRT at 89–94 ms, IVCT at 33–35 ms, SPI at 0.10–0.11, DPI at 0.27 to 0.30, HPI at 0.36–0.42, and TF at 13–17 mG. Timing parameters for exercisers show between 3.8 and 6.2% changes in IVRT, −0.4 and 11.8% changes in IVCT, and −1.7 and 6.6% for systole. Performance indices ranged from −0.4 to 11.0% changes in SPI, −7.9 to 8.7% changes in DPI, and −6.8 to 9.5 % changes in HPI (MPI). Contractile parameter TF % changes ranged from −7.6 to −23.2%.
Of the secondary measures, diastole ranged from 411 to 449 ms per week for non-exercisers and 405–430 ms per week for exercisers. These changes represent a 1.6–6.3% difference per week between exercisers and non-exercisers. Heart rate ranged from 67 to 72 bpm per week for non-exercisers and 68 to 70 bpm for exercisers. These changes represent a 0.1–5.7% difference per week between exercisers and non-exercisers.
Sleep data showed that changes in sleep efficiency were minimal between exercisers and non-exercisers. Sleep efficiency ranged from 76 to 81% per week in non-exercisers and 80 to 85% per week in exercisers. % Changes in sleep efficiency ranged from 0.6 to 6.8% per week in exercisers compared to non-exercisers.
4. Discussion
In comparison to healthy normative data available in the literature, these descriptive results suggest that PD patients have a prolonged systolic time interval. Stratifying by exercisers and non-exercisers shows similar results between the groups. Sleep efficiency was also consistent between groups.
Cardiac function is not well studied in PD. As shown by the literature review, there is evidence for subclinical dysfunction, implying reduced LV function [4], and further timing deficits [14] imply that there may be cardiac cycle impairments in patients with PD.
Cardiac timing intervals and performance indices have been reported for healthy individuals in comparison to those with a history of cardiac complications [31]. In healthy individuals, there are differences based on sex and age [31]. In comparison to the healthy data in the literature, our group shows increased systole from the healthy 279 ms for females and 289 ms for males. The participants in this study exhibited a systolic time interval of 332–348 ms, thereby resulting in reduced performance indices. Elevations in HPI and DPI are associated with coronary heart disease and a history of major adverse cardiac events [12,32]. Our results show that the decreased HPI in PD patients can be due to the increase in the systolic time interval. Similar to research available in the literature on systolic dysfunction, our results imply that there may be a prolonged AVO period, resulting in elevated systolic time in patients with PD. However, we did not have a direct age-matched comparison group.
Our results show that sleep efficiency is consistently around 80% in PD patients. Sleep is known to be strongly affected by PD; however, exercise seems to aid in helping to reduce some of these sleep impairments [33]. A randomized, controlled trial showed improvements in sleep efficiency and sleep architecture in PD patients undergoing supervised resistance training exercise three times per week for sixteen weeks, including time spent SWS and total sleep time, as compared to a group in sleep hygiene being given advice on sleep [34]. Considering that our data showed consistent sleep efficiency results, there may be a potential influence from non-exercisers being active, even if they do not engage in organized exercise programs. Therefore, monitoring sleep function can be vital when assessing physiology in patients with PD.
Limitations of this study include the current sample size, self-statements for stratification of exercisers and non-exercisers, and exclusion of data for quality control. Furthermore, the non-exercisers completed general daily activities and the exercisers varied in exercise intensity and quantity. More randomized controlled trials are needed to understand the cardiac cycle in patients with PD. These can include more exercise studies to understand how exercise can influence the cardiac cycle, and studies that include a focus on how medications can influence the cardiac cycle.
5. Conclusions
The literature review suggests that there are alterations in systolic function in patients with PD; however, this finding is not always consistent. Recent research suggests that subclinical systolic dysfunction may be prevalent in patients with PD; however, more research is required to validate these findings. What is not well understood in the literature are the cardiac cycle timing intervals. The case series described cardiac parameters which include systole, IVCT, IVRT, HPI, DPI and SPI, and compared those between exercising and non-exercising PD patients. The normative data presented provide insight and comparable values that can be of clinical utility. More participants assessed over a greater number of weeks can provide further insights.
Author Contributions
Conceptualization, H.B. and J.S.; methodology, H.B. and J.S.; software, H.B. and J.S.; formal analysis, H.B. and J.S.; investigation, H.B. and J.S.; resources, H.B.; data curation, H.B. and J.S.; writing—original draft preparation, H.B.; writing—review and editing, H.B., J.S., P.B. and Z.R.; project administration, H.B.; funding acquisition, H.B. All authors have read and agreed to the published version of the manuscript.
Funding
This research was funded by external donations to the University of Regina.
Institutional Review Board Statement
The study was conducted in accordance with the Declaration of Helsinki and approved by the University of Regina Ethics Board (REB#2020-152).
Informed Consent Statement
Informed consent was obtained from all subjects involved in the study.
Data Availability Statement
The data presented in this study can be requested from the corresponding author following appropriate request.
Conflicts of Interest
The authors declare that they have no conflict of interest. The funders had no role in the design of the study; in the collection, analyses, or interpretation of data; in the writing of the manuscript; or in the decision to publish the results.
References
- Wong, S.L.; Gilmour, H.; Ramage-Morin, P.L. Parkinson’s disease: Prevalence, diagnosis and impact. Health Rep. 2014, 25, 10–14. [Google Scholar] [PubMed]
- Zhang, Y.; Ren, R.; Sanford, L.D.; Yang, L.; Zhou, J.; Tan, L.; Li, T.; Zhang, J.; Wing, Y.K.; Shi, J.; et al. Sleep in Parkinson’s disease: A systematic review and meta-analysis of polysomnographic findings. Sleep Med. Rev. 2020, 51, 101281. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Kataoka, H.; Saeki, K.; Kurumatani, N.; Sugie, K.; Obayashi, K. Objective sleep measures between patients with Parkinson’s disease and community-based older adults. Sleep Med. 2020, 68, 110–114. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- El Mokadem, M.O.; Hassan, A.; Hussein, M.; Mohamed, Y.M. The potential role of 2D-speckle tracking echocardiography for detecting left ventricular systolic dysfunction in patients with Parkinson’s disease: A case control study. Acta Cardiol. 2021, 76, 979–986. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Heimrich, K.G.; Lehmann, T.; Schlattmann, P.; Prell, T. Heart Rate Variability Analyses in Parkinson’s Disease: A Systematic Review and Meta-Analysis. Brain Sci. 2021, 11, 959. [Google Scholar] [CrossRef] [Scilit]
- Shaffer, F.; Ginsberg, J.P. An Overview of Heart Rate Variability Metrics and Norms. Front. Public Health 2017, 5, 258. [Google Scholar] [CrossRef] [Scilit]
- Haensel, A.; Mills, P.J.; Nelesen, R.A.; Ziegler, M.G.; Dimsdale, J.E. The relationship between heart rate variability and inflammatory markers in cardiovascular diseases. Psychoneuroendocrinology 2008, 33, 1305–1312. [Google Scholar] [CrossRef] [Scilit]
- Singh, J.; Bhagaloo, L.; Sy, E.; Lavoie, A.J.; Dehghani, P.; Bardutz, H.A.; Mang, C.S.; Buttigieg, J.; Neary, J.P. Cardiac impairments in postacute COVID-19 with sustained symptoms: A review of the literature and proof of concept. Physiol. Rep. 2022, 10, e15430. [Google Scholar] [CrossRef] [Scilit]
- Singh, J.; Bhagaloo, L.; Sy, E.; Lavoie, A.J.; Dehghani, P.; Neary, P. Novel effects of acute COVID-19 on cardiac mechanical function: Two case studies. Physiol. Rep. 2021, 9, e14998. [Google Scholar] [CrossRef] [Scilit]
- Singh, J.; Ellingson, C.J.; Ellingson, C.A.; Scott, P.; Neary, J.P. Cardiac cycle timing and contractility following acute sport-related concussion. Res. Sport. Med. 2022, 20, 1–8. [Google Scholar] [CrossRef] [Scilit]
- Singh, J.; Ellingson, C.J.; Ellingson, C.A.; Scott, P.; Patrick Neary, J. Cardiac cycle timing intervals in university varsity athletes. Eur. J. Sport Sci. 2023, 23, 1–15. [Google Scholar] [CrossRef] [Scilit]
- Biering-Sorensen, T.; Mogelvang, R.; Jensen, J.S. Prognostic value of cardiac time intervals measured by tissue Doppler imaging M-mode in the general population. Heart 2015, 101, 954–960. [Google Scholar] [CrossRef] [Scilit]
- Piqueras-Flores, J.; Lopez-Garcia, A.; Moreno-Reig, A.; Gonzalez-Martinez, A.; Hernandez-Gonzalez, A.; Vaamonde-Gamo, J.; Jurado-Roman, A. Structural and functional alterations of the heart in Parkinson’s disease. Neurol. Res. 2018, 40, 53–61. [Google Scholar] [CrossRef] [Scilit]
- Canga, Y.; Emre, A.; Yuksel, G.A.; Karatas, M.B.; Yelgec, N.S.; Gurkan, U.; Calik, A.N.; Tireli, H.; Terzi, S. Assessment of Atrial Conduction Times in Patients with Newly Diagnosed Parkinson’s Disease. Park. Dis. 2018, 2018, 2916905. [Google Scholar] [CrossRef] [Scilit]
- Di Stefano, C.; Sobrero, G.; Milazzo, V.; Vallelonga, F.; Romagnolo, A.; Zibetti, M.; Milan, A.; Veglio, F.; Maule, S. Cardiac organ damage in patients with Parkinson’s disease and reverse dipping. J. Hypertens 2020, 38, 289–294. [Google Scholar] [CrossRef] [Scilit]
- Zawadka-Kunikowska, M.; Słomko, J.; Tafil-Klawe, M.; Klawe, J.J.; Cudnoch-Jędrzejewska, A.; Newton, J.L.; Zalewski, P. Role of peripheral vascular resistance as an indicator of cardiovascular abnormalities in patients with Parkinson’s disease. Clin. Exp. Pharmacol. Physiol. 2017, 44, 1089–1098. [Google Scholar] [CrossRef] [Scilit]
- Pérez, T.; Tijero, B.; Gabilondo, I.; Luna, A.; Llorens, V.; Berganzo, K.; Acera, M.; Gonzalez, A.; Sanchez-Ferro, A.; Lezcano, E.; et al. Cardiocirculatory manifestations in Parkinson’s disease patients without orthostatic hypotension. J. Hum. Hypertens 2015, 29, 604–609. [Google Scholar] [CrossRef] [Scilit]
- Kinbara, T.; Hayano, T.; Otani, N.; Furutani, Y.; Tanaka, S. Iodine-123 metaiodobenzylguanidine imaging can predict future cardiac events in Japanese patients with Parkinson’s disease. Ann. Nucl. Med. 2013, 27, 123–131. [Google Scholar] [CrossRef] [Scilit]
- Erken Pamukcu, H.; Gerede Uludag, D.M.; Tekin Tak, B.; Sorgun, M.H.; Efe, T.H.; Acibuca, A.; Akbostanci, C.; Turhan, S. Evaluation of the effect of non-ergot dopamine agonists on left ventricular systolic function with speckle tracking echocardiography. Anatol. J. Cardiol. 2018, 20, 213–219. [Google Scholar] [CrossRef] [Scilit]
- Strano, S.; Fanciulli, A.; Rizzo, M.; Marinelli, P.; Palange, P.; Tiple, D.; De Vincentis, G.; Calcagnini, G.; Censi, F.; Meco, G.; et al. Cardiovascular dysfunction in untreated Parkinson’s disease: A multi-modality assessment. J. Neurol. Sci. 2016, 370, 251–255. [Google Scholar] [CrossRef] [Scilit]
- Zhao, M.; Hu, C.; Wu, Z.; Chen, Y.; Li, Z.; Zhang, M. Effects of coordination and manipulation therapy for patients with Parkinson disease. Int. J. Neurosci. 2017, 127, 762–769. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Gunaydin, Z.Y.; Bektas, O.; Karagoz, A.; Ozer, F.F. Effects of levodopa therapy on global left ventricular systolic function in patients with Parkinson disease. Wien. Klin. Wochenschr. 2016, 128, 528–533. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Ozer, N.; Yorgun, H.; Canpolat, U.; Elibol, B. Evaluation of the valvular and biventricular functions in Parkinson patients using ergotamine-derived dopamine agonist: An observational study. Anadolu. Kardiyol. Derg. 2014, 14, 121–127. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Rasmussen, V.G.; Poulsen, S.H.; Dupont, E.; Ostergaard, K.; Safikhany, G.; Egeblad, H. Ergotamine-derived dopamine agonists and left ventricular function in Parkinson patients: Systolic and diastolic function studied by conventional echocardiography, tissue Doppler imaging, and two-dimensional speckle tracking. Eur. J. Echocardiogr. 2008, 9, 803–808. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Rasmussen, V.G.; Poulsen, S.H.; Dupont, E.; Ostergaard, K.; Safikhany, G.; Egeblad, H. Heart valve disease associated with treatment with ergot-derived dopamine agonists: A clinical and echocardiographic study of patients with Parkinson’s disease. J. Intern. Med. 2008, 263, 90–98. [Google Scholar] [CrossRef] [Scilit]
- Kenangil, G.; Ozekmekçi, S.; Koldas, L.; Sahin, T.; Erginöz, E. Assessment of valvulopathy in Parkinson’s disease patients on pergolide and/or cabergoline. Clin. Neurol. Neurosurg. 2007, 109, 350–353. [Google Scholar] [CrossRef] [Scilit]
- Imrich, R.; Eldadah, B.A.; Bentho, O.; Pechnik, S.; Sharabi, Y.; Holmes, C.; Grossman, E.; Goldstein, D.S. Functional effects of cardiac sympathetic denervation in neurogenic orthostatic hypotension. Park. Relat. Disord. 2009, 15, 122–127. [Google Scholar] [CrossRef] [Scilit]
- Meijer, J.H.; Boesveldt, S.; Elbertse, E.; Berendse, H.W. Method to measure autonomic control of cardiac function using time interval parameters from impedance cardiography. Physiol. Meas. 2008, 29, S383–S391. [Google Scholar] [CrossRef] [Scilit]
- Imrich, R.; Eldadah, B.A.; Bentho, O.; Pechnik, S.; Sharabi, Y.; Holmes, C.; Goldstein, D.S. Attenuated pre-ejection period response to tyramine in patients with cardiac sympathetic denervation. Ann. N. Y. Acad. Sci. 2008, 1148, 486–489. [Google Scholar] [CrossRef] [Scilit]
- Whitsett, T.L.; Goldberg, L.I. Effects of levodopa on systolic preejection period, blood pressure, and heart rate during acute and chronic treatment of Parkinson’s disease. Circulation 1972, 45, 97–106. [Google Scholar] [CrossRef] [Scilit]
- Biering-Sorensen, T.; Mogelvang, R.; de Knegt, M.C.; Olsen, F.J.; Galatius, S.; Jensen, J.S. Cardiac Time Intervals by Tissue Doppler Imaging M-Mode: Normal Values and Association with Established Echocardiographic and Invasive Measures of Systolic and Diastolic Function. PLoS ONE 2016, 11, e0153636. [Google Scholar] [CrossRef] [Scilit]
- Biering-Sorensen, T.; Mogelvang, R.; Pedersen, S.; Schnohr, P.; Sogaard, P.; Jensen, J.S. Usefulness of the myocardial performance index determined by tissue Doppler imaging m-mode for predicting mortality in the general population. Am. J. Cardiol. 2011, 107, 478–483. [Google Scholar] [CrossRef] [Scilit]
- Amara, A.W.; Memon, A.A. Effects of Exercise on Non-motor Symptoms in Parkinson’s Disease. Clin. Ther. 2018, 40, 8–15. [Google Scholar] [CrossRef] [Scilit]
- Amara, A.W.; Wood, K.H.; Joop, A.; Memon, R.A.; Pilkington, J.; Tuggle, S.C.; Reams, J.; Barrett, M.J.; Edwards, D.A.; Weltman, A.L.; et al. Randomized, Controlled Trial of Exercise on Objective and Subjective Sleep in Parkinson’s Disease. Mov. Disord. 2020, 35, 947–958. [Google Scholar] [CrossRef] [Scilit]
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content. |
© 2023 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
