Influence of Branching Density in Ethylene-Octene Copolymers on Electron Beam Crosslinkability

Department of Polymer Engineering, Faculty of Technology, Tomas Bata University in Zlin, Vavreckova 275, 762 72 Zlin, Czech Republic
Polymers 2015, 7(12), 2522-2534; https://doi.org/10.3390/polym7121530
Submission received: 11 November 2015 / Revised: 26 November 2015 / Accepted: 26 November 2015 / Published: 2 December 2015

Abstract

:
Two ethylene-octene copolymers (EOC) with the same melt flow index (MFI = 3 g/10 min) but different octene contents, being 20 and 35 wt % (EOC-20 and EOC-35), were compared with regard to sensitivity to electron beam crosslinking. Dynamic mechanical analysis (DMA) revealed a large influence of the octene content on the storage modulus and the glass transition temperature (Tg) but a smaller influence of irradiation on the properties below melting point (Tm). Rheology at 150 °C pointed out large differences in samples crosslinked in the 0–60 kGy range and at lower frequencies (0.1–1 Hz). The loss factor tanδ confirmed that before irradiation the two copolymers were very similar, while after irradiation to 120 kGy, the EOC-35 had considerably lower tanδ than EOC-20, which corresponds to a better elasticity (or a higher level of crosslinking). A high-temperature creep test showed a considerably lower creep for EOC with a higher octene content. An analysis of the insoluble gel content exhibited higher values for EOC-35 confirming a higher level of crosslinking. Analysis according to the Charlesby-Pinner equation revealed increased crosslinking-to-scission ratio, G(X)/G(S), for EOC-35. While the G(X) value changed only slightly, a significant decrease in the G(S) value was discovered.

1. Introduction

The development of catalysts has led to a new class of polyolefin copolymers [1]. The older type of polyolefins produced by Ziegler-Natta catalysts had a broad molecular weight distribution (MWD) and a broad distribution of the comonomer. The new type of copolymer is produced by constrained geometry catalyst technology (CGCT), which leads to copolymers with a narrow MWD and also a very uniform comonomer distribution; in other words, a uniform short chain branching (SCB). Processability (shear thinning) is enhanced by a controlled level of long chain branching (LCB).
These copolymers provide an excellent opportunity to study structure-property relationships as a function of only one variable while all other variables are kept constant. This is a necessary condition for obtaining meaningful results. Alamo et al. studied the influence of comonomer type (butane, hexane, octene) and also the influence of molecular weight [2]. Bensason et al. studied the influence of comonomer content [3], and Wood-Adams et al. focused on the degree of LCB [4].
Ethylene-octene copolymers with densities smaller than 0.89 g/cm3 have no lamellae or spherulites. Fringed micellar or bundled crystals are inferred from a low degree of crystallinity, a low melting temperature, and a granular nonlamellar morphology [5]. This unique crystalline structure then influences the mechanical properties. During the tensile test, the yield point is not present and the elastic behaviour is greatly improved (measured by tremendously reduced permanent set after repeated elongation to 100%) [1].
Ethylene-octene copolymers (EOC) have many other desirable properties, including softness, long shelf life, and good tear resistance, which enable various applications. These applications include elastic fibres for apparel with improved UV resistance (to replace Elastane) [6], packaging, blood bags, and catheters in hospitals [7]. Crosslinked polyolefin foams have various kinds of applications, such as thermal insulation, floatation, automotive trim, and sporting goods [8,9]. For some applications it is necessary to crosslink these new elastic polyolefins because some of them have a very low melting point (in the range of 45–55 °C) [10].
There are several possibilities of how to crosslink saturated polyolefin. One possibility is careful mixing with peroxide (the temperature must be kept low to avoid premature crosslinking during mixing) followed by high-temperature crosslinking of the moulded article [8,11]. Another method includes grafting by vinyltrimethoxy silane followed by exposure to water or humidity at elevated temperatures [12,13,14,15,16,17,18,19,20,21,22,23,24,25,26]. Last but not least is crosslinking by electron [11,27,28] or gamma [7,9,29] irradiation.
Although several researchers have attempted to compare the crosslinking behaviour of these copolymers, their research unfortunately varies several parameters at the same time (e.g., octene content and molecular weight) which leads to dubious conclusions. At present, there is no solid understanding of the effect of octene content on crosslinkability by irradiation. In order to get scientifically sound conclusions, in our studies we have attempted to have only one variable (octene content), while keeping all other parameters constant.
The main objective of this paper is to investigate of the influence of electron irradiation on the crosslinking behaviour of ethylene-octene copolymers with the same initial melt flow index but with a different octene content. While the introduction of peroxide or silane could cause some inhomogeneities, and thus influence the results, the e-beam crosslinking method represents a very pure, smart, and modern way of 3D network formation—for this reason, it was chosen for this investigation. It must be mentioned that the level of crosslinking was kept rather low compared to crosslinking levels in tyres, for example. This lower level of crosslinking is industrially important, for example, during foaming when the level of crosslinking must not be too high (bubbles cannot grow) or too low (bubbles collapse during foaming) [8,9]. Testing methods included dynamic mechanical analysis (DMA), rheology, a high-temperature creep test, and an analysis of the gel content.

2. Experimental

2.1. Materials

Two ethylene-octene copolymers with the trade name ENGAGE® and supplied by The Dow Chemical Company (Midland, MI, USA) which had different octene contents but the same initial melt flow index (MFI), being 3 g/10 min at 190 °C, were chosen. The octene contents of these copolymers were 20 and 35 wt %. For a better understanding, the abbreviations EOC-20 and EOC-35 reflect the octene content in wt %. The molecular weights were measured by gel permeation chromatography (GPC) and were found to be very similar for both samples. The octene content was also recalculated from wt % into mol %, and so the ethylene-to-octene molar ratio was calculated (see Table 1). Based on this data, an ideal theoretical chemical structure is shown in Figure 1a. In reality the copolymer is random and therefore the real chemical structure looks slightly different. However, Figure 1 is useful for the illustration that EOC-35 has about two-times higher branching density than EOC-20. The difference is not negligible and one can make a significantly sound conclusion about the influence of the branching density on crosslinkability of these ethylene-octene copolymers. Figure 1b illustrates the presence of both short chain branching (SCB) and also the controlled level of long chain branching (LCB), which tremendously influences processability (shear thinning) [1,4].
Low density polyethylene (LDPE), which has been used for a comparison of some properties, was Bralene RB 2-62, manufactured by Slovnaft Petrochemicals, Bratislava, Slovak Republic. MFI and the density of Bralene RB 2-62 was 2 g/10 min and 0.918 g·cm−3, respectively.
Table 1. Composition, density, and molecular weight of investigated ethylene-octene copolymers (EOC). Melt flow index at 190 °C was 3.0 g/10 min for both samples.
Table 1. Composition, density, and molecular weight of investigated ethylene-octene copolymers (EOC). Melt flow index at 190 °C was 3.0 g/10 min for both samples.
SampleTrade NameOcteneEthyleneOcteneEthyleneET/OCTDensityMwMnPDI
wt %wt %mol %mol %Molar Ratiog/cm3DaDa-
EOC-20ENGAGE 845020805.8894.1216.00.90278,54037,4002.10
EOC-35ENGAGE 8452356511.8688.147.40.87593,10642,3212.20
Figure 1. Schematics of investigated ethylene-octene copolymers: (a) ideal theoretical arrangement from the ethylene/octene molar ratio; (b) structures showing short and long chain branching (SCB and LCB).
Figure 1. Schematics of investigated ethylene-octene copolymers: (a) ideal theoretical arrangement from the ethylene/octene molar ratio; (b) structures showing short and long chain branching (SCB and LCB).
Polymers 07 01530 g001

2.2. Compression Moulding of the Sheets

Sheets with thickness 0.5 mm (stainless steel frame size was 12 cm × 6 cm) were prepared by compression moulding. Pellets were pre-heated at 130 °C under minimal pressure for 5 min and compressed at 10 MPa for 3 min in a laboratory press, and then quenched in another cold press under pressure.

2.3. Electron Beam Irradiation

Electron irradiation was performed in normal air at room temperature, in BGS Beta-Gamma-Service GmbH, Wiehl, Germany. The temperature was controlled not to exceed 50 °C. The source of radiation was toroid electron accelerator Rhodotron (10 MeV, 200 kW). The irradiation was carried out in a tunnel on a continuously moving conveyer with the irradiation dosage ranging from 30–120 kGy, in steps of 30 kGy per pass.

2.4. Dynamic Mechanical Analysis (DMA)

DMA was carried out in an IT Keisoku-seigyo (DVA-200S) machine (Osaka, Japan). Specimens were tested in the dynamic tensile mode with a frequency of 10 Hz and a strain of 0.1% from −100 to +200 °C with a heating rate of 5 K·min−1 and a grip-to-grip distance of 13.0 mm.

2.5. Rheology

Advanced Rheometric Expansion System ARES 2000 (Rheometric Scientific, Inc., Piscataway, NJ, USA) equipped with 25 mm parallel plates geometry was used to determine storage modulus G’, loss modulus G”, and complex viscosity η* in the frequency range 0.1–100 rad·s−1 at constant temperature (150 °C) and strain (1%). tanδ = G”/G’.

2.6. High-Temperature Creep Test

Tensile samples were cut out of the cross-linked sheets and were used for the tensile creep experiments according to ISO 899. Creep testing was carried out in a Memmert UFE 400 oven with digital temperature control. Creep was recorded through the glass window using a SONY SLT-A33 camera, capable of HD 1920 × 1080 video (25 frames/s). This video was later analysed at regular time intervals. The effects of octene content, MFI, and radiation dose on the creep behaviour of e-beam crosslinked EOC were studied at a fixed stress level of 0.1 MPa and a temperature of 150 °C.

2.7. Gel Content

The gel content of the e-beam crosslinked EOC and LDPE samples were determined by an evaluation of the content of insoluble fraction of cross-linked material after solvent extraction, according to ASTM D2765-01. About 0.3 g of cross-linked sample was wrapped in a 120 mesh stainless steel cage and extracted in refluxing xylene containing 1 wt % of antioxidant (Irganox 1010) for 6 h. The sample was then dried in a vacuum at 55 °C and weighed. The gel content was calculated as a ratio of the final weight to the initial weight of the sample multiplied by one hundred. Always, three samples were averaged.

2.8. Size-Exclusion Chromatography

The molecular weight measurements were performed at 160 °C on a Polymer Laboratories PL 220 high-temperature chromatograph (Polymer Laboratories, Varian Inc., Church Stretton, Shropshire, England) equipped with three 300 mm × 7.5 mm PLgel Olexis columns and a differential refractive index detector. 1,2,4-Trichlorobenzene (TCB) was used as an eluent, stabilized with butylhydroxytoluene (BHT) (Ciba, Basel, Switzerland) as an antioxidant. A mobile phase flow rate of 1 mL·min−1 was used and 200 μL was injected in all cases. All samples were prepared to a concentration of 0.5 mg·mL−1 in TCB. Narrowly distributed polyethylene standards (Polymer Standards Service GmbH, Mainz, Germany) were used for calibration purposes.

3. Results and Discussion

Initially these two copolymers were investigated at lower temperatures by dynamic mechanical analysis (DMA). Figure 2a shows the storage modulus curves. Below −50 °C there is a very small difference between these copolymers. Above −50 °C the EOC-35 exhibits a much lower storage modulus at all temperatures. This is caused by a greater disruption of regularity in the ethylene chain, which leads to lower crystallinity.
Figure 2b illustrates tanδ curves. The EOC-35 shows a single peak at −38 °C while EOC-20 exhibits two peaks, one at −22 °C, the other at +40 °C. They are called β and α transitions. The relaxation behaviour of ethylene copolymers is strongly influenced by variables that describe the crystalline state, such as crystallinity, lamellar thickness, and interfacial structure. In literature [3], three relaxations were observed and identified conventionally as α, β, and γ, in order of decreasing temperature for non-crosslinked copolymers. The low-temperature γ relaxation (at around −120 °C) is the least sensitive to comonomer content; it is not shown in this paper. However, α and β relaxations are strongly affected by comonomer content. β relaxation (at −38 and −22 °C) relates to glass transition temperature (Tg), while α relaxation (at +40 °C) relates to the reorganization of chain segments at crystal surfaces and the redistribution of tight and loose folds, cilia, and inter-crystalline links that make up the amorphous layer [3].
Figure 2. Dynamic mechanical analysis (DMA) results of crosslinked samples. (a) storage modulus; (b) loss factor tanδ.
Figure 2. Dynamic mechanical analysis (DMA) results of crosslinked samples. (a) storage modulus; (b) loss factor tanδ.
Polymers 07 01530 g002
Figure 2 illustrates results only for copolymers crosslinked by 120 kGy. The curves of polymers irradiated to a smaller extent looked very similar to these (so it is not necessary to show them all). Positions of the first peak were then used to see the influence of octene content and radiation level on glass transition temperature (Tg), which is illustrated in Figure 3a.
Figure 3. DMA analysis results. (a) Tg from peak positions of tanδ in Figure 2b; (b) storage modulus at various temperatures from Figure 2a.
Figure 3. DMA analysis results. (a) Tg from peak positions of tanδ in Figure 2b; (b) storage modulus at various temperatures from Figure 2a.
Polymers 07 01530 g003
Increasing the octene content decreases the Tg significantly. A lower Tg is favourable for impact toughness at low temperatures. Low-temperature impact testing is a common practice for consumer products that are dropped on the ground on a cold winter day, such as cell phones. Interestingly, the radiation does not significantly influence the Tg. Below melting point (Tm), mechanical properties are governed mainly by crystals that hold amorphous chains together.
In contrast, the properties above Tm are greatly influenced by radiation levels when chemical bonds play an important role; this will be shown in the following sections. The DMA revealed important data about the influence of octene content on the storage modulus at various temperatures (see Figure 3b). Higher octene content causes a lower storage modulus (or higher softness) in a copolymer. The influence is large, therefore the storage modulus axis is in logarithmic scale. The difference was less pronounced at lower temperatures (−50 and −40 °C).
High-temperature testing, when all physical crosslinking (crystals holding amorphous chains) disappears and only chemical crosslink bonds caused by irradiation remain, reveals with a high sensitivity the differences among samples exposed to various levels of radiation.
The first of these high-temperature tests is rheological measurement at 150 °C, as shown in Figure 4. G’, η*, and tanδ values are plotted as a function of frequency. The G’ and η* curves are systematically arranged with higher values for higher radiation levels at lower frequencies (0.1–1 rad·s−1). At a lower frequency, the chemical crosslinking plays an important role, while at higher frequencies (10–100 rad·s−1), the entanglements on the molecules play an important role in rheology data (the above-mentioned trend was not observed).
Figure 4. Rheology results at 150 °C for EOC-35 (a) G’, (b) η*, (c) tanδ as a function of frequency for variously irradiated samples.
Figure 4. Rheology results at 150 °C for EOC-35 (a) G’, (b) η*, (c) tanδ as a function of frequency for variously irradiated samples.
Polymers 07 01530 g004
The tanδ curves (see Figure 4c) exhibit a large difference for the radiation level in the range 0–60 kGy. Then, in the range 60–120 kGy, the differences in tanδ curves are smaller. Again, the largest difference one can observe for tanδ values is especially at low frequencies; e.g., at 0.1 rad·s−1 the tanδ dropped from 10 to 1 just by 30 kGy of irradiation.
The influence of octene content on the rheology data can be clearly seen on tanδ curves (see Figure 5). Figure 5a illustrates tanδ curves as a function of frequency for the two copolymers before irradiation. The tanδ curves are very similar. This corresponds well with the molecular weight data listed in Table 1 and the same original MFI being 3 g/10 min. Due to the extremely similar rheology and molecular weight data before irradiation, one can be certain that the conclusions made after irradiation are sound.
Figure 5b shows the tanδ curves after irradiation to 120 kGy. Clearly the EOC-35 with double branching density exhibits much lower tanδ (0.15 vs. 0.35 at 0.1 rad·s−1). Lower tanδ values correspond to better elastic behaviour (or better crosslinking).
To support the rheology data, we have carried out an additional high-temperature test, creep at 150 °C. The results are shown in Figure 6a. In the initial time period of approximately 300 s the creep curves are almost exactly the same, whereas in the time period 300–1200 s the difference is much more pronounced. Clearly EOC-35 with higher branching density creeps less than EOC-20. The difference in absolute values for various times is more visible in Figure 6b. Higher octene content decreases creep at 150 °C.
To support the previously shown data, we have carried out an analysis of insoluble gel content after boiling in xylene in a cage for a period of 6 h. For this test only, we also used a low density polyethylene (LDPE). For simplicity we can assume that there are no short chain branches (SCB) (0 wt % of octene) in LDPE. The results are depicted in Figure 7a. Samples before irradiation and samples irradiated to 30 kGy dissolved completely. The differences among samples are better visible for 90 and 120 kGy. The data were analysed in detail according to the Charlesby-Pinner equation (shown in the following section).
Figure 5. Rheology results (tanδ as a function of frequency) at 150 °C for EOC-20 and EOC-35. (a) 0 kGy, (b) 120 kGy.
Figure 5. Rheology results (tanδ as a function of frequency) at 150 °C for EOC-20 and EOC-35. (a) 0 kGy, (b) 120 kGy.
Polymers 07 01530 g005
Figure 6. Creep behaviour at 150 °C at a stress of 0.1 MPa for EOC-20 and EOC-35 irradiated by 90 kGy. (a) As a function of time; (b) as a function of octene content.
Figure 6. Creep behaviour at 150 °C at a stress of 0.1 MPa for EOC-20 and EOC-35 irradiated by 90 kGy. (a) As a function of time; (b) as a function of octene content.
Polymers 07 01530 g006
Figure 7. Gel content results for LDPE, EOC-20, EOC-35 (a) as a function of radiation level; (b) as a function of octene content.
Figure 7. Gel content results for LDPE, EOC-20, EOC-35 (a) as a function of radiation level; (b) as a function of octene content.
Polymers 07 01530 g007

Estimation of G Values of Crosslinking by the Charlesby-Pinner Method

Charlesby and Pinner published research results in 1959 concerning solubility of irradiated polyethylene. They analysed the data with the help of the following equation [30]:
s + s = p 0 q 0 + 1 q 0 u 1 r
where s is the sol fraction (s + g = 1), g is the gel fraction, r is the radiation dose, p0 is the fracture density per unit dose, q0 is the density of crosslinked units per unit dose, u1 is the number-average degree of polymerization.
These days the same equation is frequently expressed as [31]:
s + s = p 0 q 0 + 1 q 0 P n D
where Pn is the initial number-averaged degree of polymerization and D is the absorbed radiation dose in kGy [32].
Many radiation-induced chemical changes are measured quantitatively in terms of a G value, this being the number of such changes produced per 100 eV absorbed in the system [30]. G values for crosslinking and chain scission are expressed as G(X) and G(S), respectively. Crosslinking and chain scission are two competing processes that always co-exist under radiation. The overall effect depends on which of the two is predominant at a certain time. Whenever G(X) is larger than G(S), the overall result is crosslinking, and whenever G(S) is larger than G(X), the overall result is degradation. Charlesby and Pinner equation containing G values is expressed as [33]:
s + s = G ( S ) 2 G ( X ) + 4.82 × 10 6 G ( X ) M n D
where Mn is the number-averaged molecular weight.
Turgis et al. used a modified version of this equation for copolymers AB [34]:
s + s = G ( S ) 2 G ( X ) + 9.65 10 6 m A G ( X ) D M w [ x B m B + ( 1 x B ) m A ]
where mA and mB are molecular weights of comonomer units A and B, respectively. xB is the molar fraction of comonomer B.
The solubility of the two ethylene-octene copolymers was initially analysed with the help of Equation (2) (see Figure 8a). This led to intercept values p0/q0 (scission-to-crosslinking ratio) and slope values being 1/q0Pn. More detailed analysis, shown in the Supplementary Material, then led also to other values: q0, p0, G(X)/G(S), G(X), and G(S). Comparison of these values is illustrated in Figure 9.
The density of crosslinked units per unit dose (q0) is quite similar for both copolymers. However, the fracture density per unit dose (p0) is quite different—it is considerably lower for EOC-35. Reduced scission then leads to a much higher crosslinking-to-scission ratio (G(X)/G(S)) for the copolymer with higher octene content. With a higher content of octene pendants, the probability of radical formation on octene pendants increases, and thus the main chain is attacked less. The mobility of the octene pendants is much higher (compared to main chain mobility) so that the radicals on octene have a higher probability of recombination with other free radicals, which leads to crosslinking. The situation is schematically shown in Figure 10. The free radical can lead to crosslinking or scission. A copolymer with higher octene content has more short chain branches, and thus the probability of radical formation on the branch is higher (see Figure 10a—free radical formation on octene pendant—options c, d). While scission on the main chain (see Figure 10a—free radical formation on main chain—options a, b) leads to a decreased molecular weight, scission on an octene pendant has almost no influence at all on the molecular weight.
Figure 8. Charlesby-Pinner analysis for EOC-20 and EOC-35 (a) linear version, (b) non-linear curves according to Equation (7) in Supplementary Material.
Figure 8. Charlesby-Pinner analysis for EOC-20 and EOC-35 (a) linear version, (b) non-linear curves according to Equation (7) in Supplementary Material.
Polymers 07 01530 g008
Figure 9. Charlesby-Pinner analysis for EOC-20 and EOC-35—continuation: (a) p0/q0, (b) q0, (c) p0, (d) G(X)/G(S), (e) G(X), (f) G(S). p0 is the fracture density per unit dose, q0 is the density of crosslinked units per unit dose, G values for crosslinking and chain scission are expressed as G(X) and G(S), and G(X)/G(S) is the crosslinking-to-scission ratio.
Figure 9. Charlesby-Pinner analysis for EOC-20 and EOC-35—continuation: (a) p0/q0, (b) q0, (c) p0, (d) G(X)/G(S), (e) G(X), (f) G(S). p0 is the fracture density per unit dose, q0 is the density of crosslinked units per unit dose, G values for crosslinking and chain scission are expressed as G(X) and G(S), and G(X)/G(S) is the crosslinking-to-scission ratio.
Polymers 07 01530 g009
Another important fact is that a copolymer with a higher octene content contains a higher number of tertiary carbon atoms. After being exposed to e-beam radiation, the hydrogen atoms are extracted from carbon atoms. The radical on a tertiary carbon atom can be created more easily, even though the radicals on a main chain or on an octene branch are also generated (LDPE was also crosslinked, but to a lower extent). The polymer radicals can then form a crosslink by recombination with another polymer radical or they can extract a hydrogen atom from the neighbouring chain. Crosslinking options in Figure 10b, b-b, b-d, a-b, b-c play an important role during electron beam crosslinking of ethylene-octene copolymers. As it was shown, LDPE also crosslinks (a-a option) but to a lesser extent. Solubility results agree well with previously shown rheology and creep results.
Figure 10. Schematic representation of (a) free radical formation options; (b) various crosslinking options.
Figure 10. Schematic representation of (a) free radical formation options; (b) various crosslinking options.
Polymers 07 01530 g010
These presented results correspond well with other researchers [8,9,18,35]. For example, Liu et al. investigated UV photodegradation of polyethylene compared to ethylene-octene copolymers with an increasing octene content of 20, 30, and 38 wt %. After 200 h of UV exposure the values of gel content for LDPE, EOC-20, EOC-30, and EOC-38 were 18%, 22%, 31%, and 41%, respectively [35].
Vachon et al. [9] investigated foaming behaviour of gamma-irradiated ethylene-octene copolymers (EOC) with the same melt flow index (MFI = 1 g/10 min) but different octene content, EOC-30 (Engage 8003) and EOC-38 (Engage 8100). After irradiation to 50 kGy the copolymer with a higher octene content (EOC-38) exhibited an 80% gel content while the one with the lower octene content (EOC-30) had only a 68% gel content.
Abe et al. [8] made foam from two ethylene-1-hexene copolymers; LL1 had 25 branches and LL2 had 7 branches per 1000 backbone carbon atoms with the same molecular weight, Mn = 4.6 × 104 g/mol. The foams were produced directly by moulding using 0.1–0.9 wt % of dicumylperoxide (DCP) and 8 phr of a blowing agent. The copolymer with a higher branching density (LL1) rendered a foam with a higher storage modulus G’, lower tanδ, and with a higher gel content.
Sirisinha et al. [18] did research on silane-crosslinked EOC (Engage 8003) in comparison with LDPE. LDPE had a lower crosslinking rate and a lower gel content compared to EOC. In their case the short chain branching improved crosslinkability by using the silane method.

4. Conclusions

DMA testing revealed a large influence of octene content on storage modulus and Tg, but a smaller influence of irradiation on properties below Tm.
Rheology at 150 °C highlighted the huge differences in crosslinked polymers, especially in the 0–60 kGy range and at small frequencies (0.1–1 Hz). Before irradiation the two copolymers had very similar tanδ curves, while after irradiation to 120 kGy the EOC-35 had considerably lower tanδ than EOC-20, which corresponds to better elasticity (or a higher level of crosslinking).
High-temperature creep test, especially after 300 s, showed a considerably lower creep for EOC-35, confirming a higher level of crosslinking.
Analysis of insoluble gel content illustrated higher values for EOC-35, again confirming a higher level of crosslinking. Analysis according to the Charlesby-Pinner equation revealed increased crosslinking-to-scission ratio, G(X)/G(S), for EOC-35. Interesting was a substantial decrease in the G(S) parameter. This was explained by scission on an octene pendant which does not lead to a scission of the main chain (and EOC-35 has more octene pendants). Also, in EOC-35 the amount of tertiary carbon atoms with higher reactivity is higher.

Supplementary Materials

The supplementary materials is available online at: www.mdpi.com/2073-4360/7/12/1530/s1.

Acknowledgements

This work has been supported by the Internal Grant Agency of the Tomas Bata University in Zlin. Number IGA/FT/2015/007.

Conflicts of Interest

The author declares no conflict of interest. The founding sponsors had no role in the design of the study; in the collection, analyses, or interpretation of data; in the writing of the manuscript, and in the decision to publish the results.

References

  1. Chum, P.S.; Kao, C.I.; Knight, G.W. Structure-property relationships in polyolefins made by constrained geometry catalyst technology. Plast. Eng. 1995, 51, 21–23. [Google Scholar]
  2. Alamo, R.G.; Viers, B.D.; Mandelkern, L. Phase-structure of random ethylene copolymers—A study of counit content and molecular-weight as independent variables. Macromolecules 1993, 26, 5740–5747. [Google Scholar] [CrossRef]
  3. Bensason, S.; Minick, J.; Moet, A.; Chum, S.; Hiltner, A.; Baer, E. Classification of homogeneous ethylene-octene copolymers based on comonomer content. J. Polym. Sci. B Polym. Phys. 1996, 34, 1301–1315. [Google Scholar] [CrossRef]
  4. Wood-Adams, P.M.; Dealy, J.M.; Degroot, A.W.; Redwine, O.D. Effect of molecular structure on the linear viscoelastic behavior of polyethylene. Macromolecules 2000, 33, 7489–7499. [Google Scholar] [CrossRef]
  5. Minick, J.; Moet, A.; Hiltner, A.; Baer, E.; Chum, S.P. Crystallization of very-low-density copolymers of ethylene with α-olefins. J. Appl. Polym. Sci. 1995, 58, 1371–1384. [Google Scholar] [CrossRef]
  6. Casey, P.; Chen, H.Y.; Poon, B.; Bensason, S.; Menning, B.; Liu, L.Z.; Hu, Y.S.; Hoenig, W.; Gelfer, M.; Dems, B.; et al. Polyolefin based crosslinked elastic fiber: A technical review of DOW XLA™ elastic fiber technology. Polym. Rev. 2008, 48, 302–316. [Google Scholar] [CrossRef]
  7. Li, J.Q.; Peng, J.; Qiao, J.L.; Jin, D.B.; Wei, G.S. Effect of gamma Irradiation on ethylene-octene copolymers. Radiat. Phys. Chem. 2002, 63, 501–504. [Google Scholar] [CrossRef]
  8. Abe, S.; Yamaguchi, M. Study on the Foaming of crosslinked polyethylene. J. Appl. Polym. Sci. 2001, 79, 2146–2155. [Google Scholar] [CrossRef]
  9. Vachon, C.; Gendron, R. Effect of gamma-irradiation on the foaming behavior of ethylene-co-octene polymers. Radiat. Phys. Chem. 2003, 66, 415–425. [Google Scholar] [CrossRef]
  10. Kale, L.T.; Plumley, T.A.; Patel, R.M.; Redwine, O.D.; Jain, P. Structure-property relationships of ethylene/1-octene and ethylene/1-butene copolymers made using insite technology. J. Plast. Film Sheeting 1996, 12, 27–40. [Google Scholar]
  11. Nicolas, J.; Ressia, J.A.; Valles, E.M.; Merino, J.C.; Pastor, J.M. Characterization of metallocene ethylene-1-octene copolymers with high comonomer content cross-linked by dicumyl peroxide or β-radiation. J. Appl. Polym. Sci. 2009, 112, 2691–2700. [Google Scholar] [CrossRef]
  12. Sirisinha, K.; Meksawat, D. Comparison in processability and mechanical and thermal properties of ethylene-octene copolymer crosslinked by different techniques. J. Appl. Polym. Sci. 2004, 93, 1179–1185. [Google Scholar] [CrossRef]
  13. Sirisinha, K.; Meksawat, D. Changes in properties of silane-water crosslinked metallocene ethylene-octene copolymer after prolonged crosslinking time. J. Appl. Polym. Sci. 2004, 93, 901–906. [Google Scholar] [CrossRef]
  14. Jiao, C.M.; Wang, Z.Z.; Gui, Z.; Hu, Y. Silane grafting and crosslinking of ethylene-octene copolymer. Eur. Polym. J. 2005, 41, 1204–1211. [Google Scholar] [CrossRef]
  15. Sirisinha, K.; Meksawat, D. Preparation and properties of metallocene ethylene copolymer crosslinked by vinyltrimethoxysilane. Polym. Int. 2005, 54, 1014–1020. [Google Scholar] [CrossRef]
  16. Sirisinha, K.; Chimdist, S. Comparison of techniques for determining crosslinking in silane-water crosslinked materials. Polym. Test 2006, 25, 518–526. [Google Scholar] [CrossRef]
  17. Kamphunthong, W.; Sirisinha, K. Structure development and viscoelastic properties in silane-crosslinked ethylene-octene copolymer. J. Appl. Polym. Sci. 2008, 109, 2347–2353. [Google Scholar] [CrossRef]
  18. Sirisinha, K.; Chimdist, S. Silane-crosslinked ethylene-octene copolymer blends: thermal aging and crystallization study. J. Appl. Polym. Sci. 2008, 109, 2522–2528. [Google Scholar] [CrossRef]
  19. Sirisinha, K.; Kamphunthong, W. Rheological analysis as a means for determining the silane crosslink network structure and content in crosslinked polymer composites. Polym. Test 2009, 28, 636–641. [Google Scholar] [CrossRef]
  20. Bailly, M.; Kontopoulou, M.; El Mabrouk, K. Effect of polymer/filler interactions on the structure and rheological properties of ethylene-octene copolymer/nanosilica composites. Polymer 2010, 51, 5506–5515. [Google Scholar] [CrossRef]
  21. Garnier, L.; Duquesne, S.; Casetta, M.; Lewandowski, M.; Bourbigot, S. Melt spinning of silane-water cross-linked polyethylene-octene through a reactive extrusion process. React. Funct. Polym. 2010, 70, 775–783. [Google Scholar] [CrossRef]
  22. Kamphunthong, W.; Sirisinha, K. Thermal property improvement of ethylene-octene copolymer through the combined introduction of filler and silane crosslink. J. Appl. Polym. Sci. 2010, 115, 424–430. [Google Scholar] [CrossRef]
  23. Sirisinha, K.; Boonkongkaew, M.; Kositchaiyong, S. The effect of silane carriers on silane grafting of high-density polyethylene and properties of crosslinked products. Polym. Test 2010, 29, 958–965. [Google Scholar] [CrossRef]
  24. Chen, W.C.; Lai, S.M.; Qiu, R.Y.; Tang, S.X. Role of silane crosslinking on the properties of melt blended metallocene polyethylene-g-silane/clay nanocomposites at various clay contents. J. Appl. Polym. Sci. 2012, 124, 2669–2681. [Google Scholar] [CrossRef]
  25. Nordin, R.; Ismail, H.; Ahmad, Z.; Rashid, A. Performance improvement of (linear low-density polyethylene)/poly(vinyl alcohol) blends by in situ silane crosslinking. J. Vinyl Addit. Technol. 2012, 18, 120–128. [Google Scholar] [CrossRef]
  26. Sirisinha, K.; Boonkongkaew, M. Improved silane grafting of high-density polyethylene in the melt by using a binary initiator and the properties of silane-crosslinked products. J. Polym. Res. 2013, 20, 9. [Google Scholar] [CrossRef]
  27. Perraud, S.; Vallat, M.F.; Kuczynski, J. Radiation crosslinking of poly(ethylene-co-octene) with electron beam radiation. Macromol. Mater. Eng. 2003, 288, 117–123. [Google Scholar] [CrossRef]
  28. Mishra, J.K.; Chang, Y.W.; Lee, B.C.; Ryu, S.H. Mechanical properties and heat shrinkability of electron beam crosslinked polyethylene-octene copolymer. Radiat. Phys. Chem. 2008, 77, 675–679. [Google Scholar] [CrossRef]
  29. Benson, R.S.; Moore, E.A.; Martinez-Pardo, M.E.; Zaragoza, D.L. Effect of gamma irradiation on ethylene-octene copolymers produced by constrained geometry catalyst. Nucl. Instrum. Meth. B 1999, 151, 174–180. [Google Scholar] [CrossRef]
  30. Charlesby, A.; Pinner, S.H. Analysis of the solubility behaviour of irradiated polyethylene and other polymers. Proc. R. Soc. Lon. Ser. A 1959, 249, 367–386. [Google Scholar] [CrossRef]
  31. Dubey, K.A.; Chaudhari, C.V.; Rao, R.; Bhardwaj, Y.K.; Goel, N.K.; Sabharwal, S. Radiation processing and characterization of poly(vinyl alcohol) nano-composites, part 1: Nano-particulate filler tuned crosslinking behavior. J. Appl. Polym. Sci. 2010, 118, 3490–3498. [Google Scholar] [CrossRef]
  32. Mondal, M.; Gohs, U.; Wagenknecht, U.; Heinrich, G. Efficiency of high energy electrons to produce polypropylene/natural rubber-based thermoplastic elastomer. Polym. Eng. Sci. 2013, 53, 1696–1705. [Google Scholar] [CrossRef]
  33. Makuuchi, K.; Cheng, S. Radiation Processing Of Polymer Materilas And Its Industrial Applications; Wiley: New York, NY, USA, 2012. [Google Scholar]
  34. Turgis, J.D.; Coqueret, X. Electron beam sensitivity of butyl acrylate copolymers: effects of composition on reactivity. Macromol. Chem. Phys. 1999, 200, 652–660. [Google Scholar] [CrossRef]
  35. Liu, Z.Y.; Chen, S.J.; Zhang, J. Photodegradation of ethylene-octene copolymers with different octene contents. Polym. Degrad. Stab. 2011, 96, 1961–1972. [Google Scholar] [CrossRef]

Share and Cite

MDPI and ACS Style

Svoboda, P. Influence of Branching Density in Ethylene-Octene Copolymers on Electron Beam Crosslinkability. Polymers 2015, 7, 2522-2534. https://doi.org/10.3390/polym7121530

AMA Style

Svoboda P. Influence of Branching Density in Ethylene-Octene Copolymers on Electron Beam Crosslinkability. Polymers. 2015; 7(12):2522-2534. https://doi.org/10.3390/polym7121530

Chicago/Turabian Style

Svoboda, Petr. 2015. "Influence of Branching Density in Ethylene-Octene Copolymers on Electron Beam Crosslinkability" Polymers 7, no. 12: 2522-2534. https://doi.org/10.3390/polym7121530

Article Metrics

Back to TopTop