Next Article in Journal
Comparative Study on Kinetics of Ethylene and Propylene Polymerizations with Supported Ziegler–Natta Catalyst: Catalyst Fragmentation Promoted by Polymer Crystalline Lamellae
Previous Article in Journal
One-Pot Processing of Regenerated Cellulose Nanoparticles/Waterborne Polyurethane Nanocomposite for Eco-friendly Polyurethane Matrix
 
 
Article
Peer-Review Record

Characterization of the Fluidity of the Ultrasonic Plasticized Polymer Melt by Spiral Flow Testing under Micro-Scale

Polymers 2019, 11(2), 357; https://doi.org/10.3390/polym11020357
by Bingyan Jiang 1,2, Yang Zou 1,2, Tao Liu 1,2 and Wangqing Wu 1,2,*
Reviewer 1: Anonymous
Reviewer 2: Anonymous
Polymers 2019, 11(2), 357; https://doi.org/10.3390/polym11020357
Submission received: 15 January 2019 / Revised: 11 February 2019 / Accepted: 12 February 2019 / Published: 18 February 2019

Round 1

Reviewer 1 Report

The manuscript “Characterisation of the fluidity o the ultrasonic plasticized polymer melt by spiral flow testing under microscale” by Bingyan Jiang et. al., is an interesting paper where the authors investigate The fluidity of the molten polymer plasticized by ultrasonic vibration using an Archimede spiral mold.

The manuscript is well written and well-articulated, and the single factor analysis approach was used for determining the role of the process parameters.

I recommend the article to be published after minor revisions:

Title: line 2 “ultrasonic”

Line 34: “have report”

Line 67: “an reference”

Iine 71: “there are overall three kinds of material was used …”

 


Author Response

Dear Reviewer:


Thank you for your review of our manuscript (ID: polymers-436797). We appreciate the concerns and suggestions provided and have revised our manuscript accordingly: 


Point 1: Title: line 2 “ultrasonic”. 


Response 1: Replace “ultraosnic” with “ultrasonic”.


Point 2: Line 34: “have report”.


Response 2: Replace “have report” with “have reported”.


Point 3: Line 67: “an reference”.


Response 3: Replace “an reference” with “a reference”.


Point 4: Line 71: “there are overall three kinds of material was used …”


Response 4: Replace “There are overall three kinds of material was used in this study i.e.” with “There are three kinds of material used in this study, i.e.,”.


With sincere thanks

Author Response File: Author Response.docx

Reviewer 2 Report

I have only one comment. I didn't found the channel width of the spiral. It is also the important data for understanding of the cavity filling proces. Please add that information.

Author Response

Dear Reviewer:


Thank you for your review of our manuscript (ID: polymers-436797). We appreciate the concerns and suggestions provided and have revised our manuscript accordingly: 


Point 1: I have only one comment. I didn't find the channel width of the spiral. It is also the important data for understanding of the cavity filling process. Please add that information. 


Response 1: Channel width is 1500 μm and has been added to line 98.


With sincere thanks


Author Response File: Author Response.docx