Article

Relationship between Pharmacokinetic Profile and Clinical Efficacy Data of Three Different Forms of Locally Applied Flurbiprofen in the Mouth/Throat

1
Institute of Pharmacology, First Faculty of Medicine, Charles University, Albertov 4, 12800 Prague, Czech Republic
2
Reckitt Healthcare Limited, 103-105 Bath Road, Slough, Berkshire SL1 3UH, UK
3
Cadore INV Scientific Consultant, Akademicka 1, 10800 Prague, Czech Republic
4
SAS BORVO Consultant, 18 Av de Charade, 63122 Ceyrat, France
*
Author to whom correspondence should be addressed.
Pharmaceutics 2023, 15(7), 1863; https://doi.org/10.3390/pharmaceutics15071863
Submission received: 8 May 2023 / Revised: 16 June 2023 / Accepted: 16 June 2023 / Published: 1 July 2023

Abstract

:
This study aimed to link pharmacokinetic (PK) data from different flurbiprofen preparations for the treatment of sore throat with published data to elucidate whether early efficacy is due to the local action of flurbiprofen or a systemic effect after absorption of the swallowed drug. Three comparative bioavailability studies conducted in healthy subjects provided data from flurbiprofen 8.75 mg formulations, including spray solution, spray gel, lozenges, and granules. A parallel interstudy comparison was made of PK parameters, including partial AUCs (pAUCs), using an ANOVA model with the calculation of 90% confidence intervals (CI) for the differences between least squares (LS) means for each of the test groups versus the respective reference groups. All three studies showed bioequivalence for the respective product comparisons. The interstudy comparison showed a slower rate of absorption for granules compared to spray solution (reference) based on Tmax, Cmax, and pAUCs for 1 h and 2 h. When AUC0.25h and AUC0.5h were considered, slower rates of absorption were also seen for lozenges and spray gel. The differences correlated with the reported time of onset of action, which is faster for the spray solution (20 min) compared to lozenges (26 min) and granules (30 min). These pAUCs provide useful data that allow for the discrimination between formulations. Moreover, the pAUC values represent <5% of the total AUC, suggesting that the early onset of pain relief is a response to immediate local absorption at the site of action rather than a systemic effect.

1. Introduction

The main objective of developing locally applied products, including non-steroidal anti-inflammatory drugs (NSAIDs), is to ensure that they are delivered locally and exert their effect only at the locally affected site, with any systemic effects being considered undesirable [1,2]. The site-specific absorption of locally applied NSAIDs has been achieved through targeted delivery using various pharmaceutical forms with evidence of local tissue concentration [3,4]. This maximises the local effect of NSAIDs at the site of inflammation while reducing the dose administered to the patient in order to limit systemic exposure and thus potential adverse effects [5,6]. The concept of local delivery of a low dose of the drug for localised effect has been applied successfully to several NSAIDs [7], with efficacy having been demonstrated despite much lower systemic exposure compared with oral administration.
For example, in a study in healthy subjects that compared topical diclofenac sodium 2% solution twice daily and diclofenac sodium 1.5% solution four times daily to oral diclofenac sodium 75 mg tablets twice daily, the 2% and 1.5% topical solutions were bioequivalent with respect to AUC at steady state, with approximately 93% lower systemic exposure compared to oral administration [8]. Topical application was associated with slower absorption and delayed elimination, with an apparent terminal half-life 4 to 6 times longer than that for oral diclofenac. This is presumed to be due to a reservoir effect in the skin and subcutaneous fat, from which there is a sustained release of drug into the underlying target tissues [9]. The much lower exposure seen with the topical solutions did not affect efficacy when compared with oral diclofenac but was associated with significantly fewer adverse events such as gastrointestinal (GI) complaints and increased liver enzymes [3,10,11].
The efficacy of locally applied, locally acting NSAID products is a consequence of higher concentrations achieved in the target tissues when compared to those seen in the systemic circulation. Topical diclofenac or flurbiprofen, for example, are associated with better penetration [5,12] and permeation of the drug into the target tissues, with a lower plasma-to-tissue ratio than is seen for oral diclofenac [9]. Following application of diclofenac sodium 4% spray gel to the knee two- or three-times daily for 3 days prior to planned total arthroplasty, the median diclofenac concentration was approximately 10–20-fold higher in synovial tissue (36.2 and 42.8 ng/g) than in synovial fluid (2.6 and 2.8 ng/mL) or plasma (3.9 and 4.1 ng/mL) [3]. Moreover, after topical delivery, diclofenac is highly bound to the target tissues, so levels are sustained for a longer duration (at least several hours) compared to oral administration, thus maintaining concentrations that are sufficient to exert a therapeutic effect [9].
Similar data have been reported for flurbiprofen. For example, in patients administered flurbiprofen 40 mg perorally or topically 16 h and 2 h prior to knee surgery, significantly higher concentrations of the active drug were found in the fat, tendon, muscle, and periosteal tissues in the topical application group compared to those who received tablets [12].
Although the efficacy and safety of locally applied NSAIDs are well established in a variety of indications, the role of local versus systemic concentrations in the pharmacological effects remains incompletely understood. For flurbiprofen 8.75 mg lozenges and sprays used in the treatment of oral inflammatory conditions, in vitro data show that the active drug reached all layers of the human cadaveric pharynx mucosal tissue, including the underlying lamina propria, which contains blood vessels and nerve fibres that contribute to pain during pharyngitis [4,13]. This suggests that flurbiprofen has a local mechanism of action for sore throats that is linked with the concentration in the oral tissues rather than systemic blood concentrations. An adhesive gel spray formulation that has shown, in vitro, higher penetration into the oropharyngeal tissues could, potentially, have better targeted clinical efficacy and reduced the scope for adverse events by reducing the amount of swallowed flurbiprofen (data on file). This is consistent with published data for different topical pharmaceutical forms of flurbiprofen (solution, granules, and lozenges), which differ with respect to onset of action (from 2 to 5 min) and time to meaningful pain relief [14,15,16].
In this study, we compared the PK parameter (pAUC) of different locally applied flurbiprofen preparations with the efficacy parameter (time to clinically meaningful pain relief) from published studies of the treatment of sore throat. Such a comparison contributes to the elucidation of whether initial efficacy is due to local absorption in the throat rather than systemic absorption of swallowed flurbiprofen from the GI tract.

2. Materials and Methods

2.1. Pharmacokinetic Studies

Three randomised, open-label, crossover design PK studies were conducted in healthy male and female subjects following standard inclusion/exclusion criteria for bioavailability and bioequivalence studies [17,18], including an age range of 18–55 years with normal oral mucosa and a Body Mass Index (BMI) of 18.5–30 kg/m2. The studies were conducted in accordance with the Declaration of Helsinki and Good Clinical Practice recommendations. Approvals were obtained from an ethics committee in line with local regulations, and written informed consent was obtained from each participant. The studies were registered on the European Union Drug Regulating Authorities Clinical Trials Database (EudraCT).
Study EudraCT 2018-003175-36 included 16 subjects and compared two flurbiprofen viscous spray gel formulations to a reference spray solution (non-viscous). The treatment regimen for all products was a single therapeutic dose of 3 sprays (equivalent to 8.75 mg flurbiprofen) delivered to the back of the throat.
The study EudraCT 2011-003332-31 compared two spray solutions (Treatments B and D; 3 sprays for an 8.75 mg dose) to a flurbiprofen 8.75 mg lozenge formulation (Treatment A) in 33 subjects.
Finally, the randomised study EudraCT 2008-005177-34 consisted of 16 subjects using flurbiprofen granules or a lozenge formulation, both at a strength of 8.75 mg, crossing over to the alternative treatment in the second period.
A total of 12, 18, and 15 blood samples, respectively, were drawn over 720 min from each subject at each study period in the first, second, and third studies; all studies included sampling at least every 5 min for the first 15 min (two studies involving spray also included a 2-min sample), along with further sampling at 30 min. The sampling time points were based on standard requirements of adequate sampling prior to and around the Cmax [1] and then up to 720 min to capture the full plasma concentration profiles up to more than 3 terminal half-lives. The spray studies included an earlier sampling time point based on a pilot study (Study No. TH0918 [19]). The plasma obtained was analysed for flurbiprofen using a validated high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) method [20,21]. The following PK parameters were derived to describe the PK properties of the respective flurbiprofen formulations and are similar to those published for the spray solution pilot study (Study No. TH0918 [19]): maximum observed plasma concentration (Cmax), area under plasma concentration curve from administration to last quantifiable concentration at time t (AUC0−t), time to maximum observed concentration (Tmax), AUC extrapolated to infinity (AUC0−inf), elimination rate constant (Kel), and elimination half-life (T½). An Analysis of Variance (ANOVA) model (separate models for each product) using Excel was fitted to naturally log-transformed (ln) AUC0−t, Cmax, and AUC0−inf with fixed terms for treatment, period, sequence, and subject nested within sequence, and 90% CI for the differences between LS means for each of the test groups versus the chosen reference group were calculated for each of the individual PK studies.

2.2. Parallel Interstudy Comparison and Partial AUCs

Plasma concentration data from all three PK studies was combined into one database. Partial AUCs (pAUCs) over the first two hours after administration of flurbiprofen products were calculated using the linear trapezoidal rule as an additional metric to reflect the rate of absorption [22,23]. The pAUCs up to 30 min also serve as a tool in the case of locally applied products to separate early drug absorption at the site of action from the systemic absorption of swallowed drugs from the GI tract [1]. The parallel interstudy comparison was based on an ANOVA model that was fitted to ln AUC0-t, Cmax, and pAUCs (for the intervals 0–15 min, 0–30 min, 0–1 h, and 0–2 h) with fixed terms for treatment, and the 90% CI for the differences between LS means for each of the test groups versus the respective reference groups was calculated. Reference scaling was used in order to take potential differences in study design into account in the across-study comparison, as previously described by Cardot et al. [24]. Data from spray formulations and subsequently from the flurbiprofen lozenge formulation were used for this purpose, both representing common points across the PK studies. Finally, linear regressions were used to compare the reference scaled early pAUCs (0–15 and 0–30 min) data from the studies with the respective onset of action times previously reported for different formulations [14,15,16,25]. Specifically, time to clinically meaningful pain relief [25,26] was used in order to provide a comprehensive treatment comparison with direct clinical implications.

3. Results

The results of the study EudraCT 2018-003175-36 in 16 subjects are presented in Figure 1 and demonstrate a similar overall exposure for all spray formulations (simple solution and gel).
The PK parameters were similar for extent of absorption, with geometric means for AUC0−t ranging from 3930 ng∗h/mL (spray gel B) to 4225 ng∗h/mL (marketed spray solution), denoting a 7% difference between the extremes. As a measure of rate of absorption, the geometric means for Cmax ranged from 922 to 1040 ng/mL (highest for the marketed spray), with a 12% difference between the extremes. Both spray gel formulations were bioequivalent to the reference spray solution product, with 90% CI for AUC and Cmax falling within the standard acceptance range of 80–125%, apart from the lower CI for Cmax for the second spray gel formulation (B), which was marginally below 80%. No statistically significant differences were observed in secondary PK parameters (Tmax, T½, and Kel) when the new spray gel formulations were compared with marketed spray solutions.
The results of study EudraCT 2011-003332-31 in 33 subjects (presented in Figure 2) also demonstrated similar overall exposure for all formulations (8.75 mg spray solution and lozenges).
The spray solutions (Treatments B and D) and lozenges (Treatment A) differed by less than 3% for extent of absorption (AUC0−t geometric means ranging from 5544 to 5682 ng∗h/mL) and by less than 2% for rate of absorption (Cmax geometric means ranging from 1553 to 1580 ng/mL). The 90% CIs for the ratios of the geometric means for Cmax and AUC0−t fell within the standard acceptance range of 80–125%, confirming the bioequivalence of the spray solutions compared to the lozenges. There was a statistically significant difference between Tmax values (Wilcoxon Matched Pair Test; p value = 0.030, D versus A), with plasma concentrations peaking earlier for the spray solutions (median 0.50 h) than for the lozenges (median 0.83 h), a difference of well over 20%.
Finally, study EudraCT 2008-005177-34 in 16 subjects also demonstrated a similar overall exposure for both formulations (granules and lozenges), as shown in Figure 3.
The extent of absorption (AUC0−t) was similar for granules and lozenges, with geometric means (5932 and 6251 ng∗h/mL) differing by approximately 5%. For Cmax as a measure of rate of absorption, the respective geometric means were 1413 and 1620 ng/mL, just less than 13% lower for granules compared to lozenges. The formulations were bioequivalent, with 90% CIs for the ratios of geometric means for Cmax and AUC0−t falling within the standard acceptance range of 80–125%. There was a statistically significant difference between formulations for peak plasma concentrations (Wilcoxon Matched Pair Test; p value = 0.030); although median Tmax values for the lozenge formulation (0.75 h) differed from granules (0.88 h) by less than 20%, the respective ranges differed markedly (0.50 to 1.00 h for lozenges and 0.25 to 2.00 h for granules), and the difference between arithmetic mean Tmax values was ~25 min.

3.1. Sensitivity Analysis

The parallel interstudy comparison confirmed the bioequivalence of the spray gel, lozenges, and granules to the marketed spray solution formulation (reference value, 100%) with respect to extent of absorption (AUC0−t) but suggested possible differences for rate of absorption as measured by Cmax, with a slower rise in plasma levels for granules when compared to spray solution (Table 1).

3.2. Partial AUC Comparison

The suggested differences in the formulations are not clearly illustrated using traditional metrics as applied to the assessment of bioequivalence between formulations. Therefore, additional post hoc analyses were performed in order to describe the early phase of the absorption process and the initial onset of measurable plasma levels. Individual plasma concentration data were used to calculate pAUCs for the intervals 0–15 min, 0–30 min, 0–1 h, and 0–2 h (Table 2 and Table 3).
The pAUCs at these earlier time points more clearly indicate possible differences between the formulations. As shown in Table 2 and Table 3, the analysis revealed statistically significant differences between the granule formulation and spray solution for AUC0.25h and AUC0.5h, and also for AUC1h and AUC2h. For the comparison between lozenges and the spray solution, a significant difference was seen only for AUC0.25h, with a trend for a difference for AUC0.5h (p value = 0.13). A similar pattern was also observed for the comparison between one of the spray gel formulations (A) and the spray solution, with a significant difference detected for AUC0.25h and a trend for a difference for AUC0.5h (p value = 0.08). The behaviour of the spray gel formulation (B) was not statistically different from the spray solution for any of the pAUCs.

3.3. Correlation of Early Partial AUCs with the Onset of Action

In order to elucidate the possible links between therapeutic effect and early exposure, the pAUCs for 0–15 min and 0–30 min were compared and correlated with the previously published onset of action data, specifically the time to clinically meaningful pain relief for the different formulations (Table 4).
Linear correlation coefficient values were close to 1, strongly supporting a link between the extent of absorption of flurbiprofen in the first 15–30 min and the timing of onset of action (time to clinically meaningful pain relief) as reported in previously published therapeutic trials [16,25].

4. Discussion

Currently, flurbiprofen is the only low-dose NSAID [14,15] for oromucosal drug delivery that can be used for the treatment of sore throat globally, including the EU, Russia, LATAM, and certain ASEAN regions. The use of locally applied, locally acting NSAIDs is preferred due to a lower frequency of adverse effects when compared to systemic NSAID treatment [27]. Sore throat constitutes a significant burden on quality of life even within a short period of time [28], and so it is important to have products on the market that have a rapid onset of action and a comparable level of efficacy to classical peroral NSAIDs. The rapid onset of action of analgesic formulations generally provides better overall pain relief and a lesser need for additional analgesia [29].
The PK data presented above show that locally acting flurbiprofen 8.75 mg formulations, including sprays (simple solution and gel spray), lozenges, and granules, all exhibit a very similar extent of absorption as shown by similar (bioequivalence criteria, defined as 90% CI within the standard range of 80–125%) AUC0−t values. Moreover, the rate of absorption as expressed by Cmax values is also similar, with a 90% CI within or close to the standard bioequivalence range of 80–125%, albeit with slightly slower absorption for granules when compared to lozenges (Cmax value lower by about 13%; later Tmax). In contrast, it is known that different topical pharmaceutical forms of flurbiprofen (spray solution (Study No. TH0918 [19]), lozenges, and granules) differ in terms of time to onset of action, a clinically relevant efficacy parameter [25]. The available data indicate that patients experience clinically meaningful pain relief around 20 min after using flurbiprofen spray solution and after about 30 min with flurbiprofen granules, while flurbiprofen lozenges fall somewhere between the two (approximately 26 min) [14,15,16,25]. Even when the differences in design of therapeutic trails are taken into account, it seems clear that the nature of the locally applied flurbiprofen formulation impacts speed of effect via differences in local bioavailability identified based on early pAUC0.25h and pAUC0.5h.
Given the differences in time to onset of clinically meaningful pain relief for the different formulations that met bioequivalence criteria (90% CI within 80–125%) (Table 1), conventional PK parameters, i.e., AUC0−t and Cmax, do not directly and strongly reflect comparable efficacy [30] for these locally applied, locally acting NSAIDs. Our alternative approach, using reference scaling of data from all PK studies [24], created a data set that allowed comparisons of pAUC correlations to the onset of clinically meaningful effects across the different pharmaceutical forms of flurbiprofen (Table 4).
Thereafter, the formulations were compared based on pAUC calculations for 1 and 2 h (Table 2). These pAUC comparisons indicated statistically significant differences between granules and spray solution, in line with the later Tmax and lower Cmax for the granule formulation described above. In contrast, for lozenges vs. spray solution, the 90% confidence intervals for AUC1h and AUC2h fell within standard bioequivalence limits, again suggesting no clinically relevant difference between formulations. This finding is consistent with clinical observations made in therapeutic non-inferiority studies, which demonstrated similar efficacy for these respective formulations at 1 h [31,32]. The pAUCs also show that a newly developed spray gel formulation has a similar pattern of absorption to lozenges, with a point estimate for AUC1h and AUC2h within the standard bioequivalence limits and a lower limit of the 90% CI slightly below the lower acceptance range when compared to spray solution (Table 2), potentially suggesting a lower contribution of GI absorption.
In order to filter out potential GI absorption with resultant systemic effects, pAUCs after 15 and 30 min were also calculated. These early pAUCs most likely reflect local absorption in the oral cavity and pharynx prior to the time when GI absorption could occur and so better reflect permeation into local tissues than AUC data from later timepoints, thus enabling a better description of the behaviour of different formulations of locally applied drugs in the oral cavity and pharynx. A comparison of AUC0.25h and AUC0.5h values for the different formulations revealed significant differences for granules and for lozenges when compared to the spray solution (Table 3), although the AUC0.5h comparison for lozenges with respect to the spray solution did not quite reach statistical significance. On the other hand, when both were compared to the spray solution, the new spray gel formulation outperformed the lozenges with respect to early absorption (AUC0.25h) and had similar AUC0.5h values (Table 3). These findings are consistent with the objective for the development of the spray gel formulation, which is designed to have better contact with the mucosa, leading to more targeted delivery and increased residence time within the pharynx, the intended site of action. Such findings have clinical significance since the early onset of action of NSAIDs strongly correlates with their effectiveness [29,33].
The overall PK rank order of the formulations fits well with the formulation properties, with the lowest values observed for granules, followed by lozenges and the spray gel formulation when compared to spray solution. Flurbiprofen granules first need to be dissolved in saliva before absorption can occur; however, once dissolved, the drug will be swallowed rapidly with saliva, leading to a short residence time in the mouth, as shown by the lowest values for partial AUC0.25h, AUC0.5h, and AUC1h (Table 2 and Table 3). Lozenges contain the solubilised drug in the lozenge mass and provide already dissolved flurbiprofen, which must be released from the formulation by saliva; however, as for granules, the drug will also be partly swallowed, as can be seen from the pAUC analyses (Table 2 and Table 3). The spray solution formulation eliminates the need for dissolution and release from the formulation and provides targeted pharynx delivery, and therefore demonstrated the fastest regional absorption based on all pAUCs. The spray gel formulation was developed to maintain the properties of the spray solution while also extending the regional residence time. As demonstrated, the spray gel, in particular formulation B, provides rapid local delivery as shown by AUC0.25h and AUC0.5h values, as well as sustained regional delivery over the first two hours based on AUC1h and AUC2h values (Table 2 and Table 3). Based on the pAUC data, we think that the differences in formulations are likely to be due to the formulation technology. The gel spray, in contrast to lozenges, is directly applied to the throat but is a more viscous form than the spray solution. The gel spray in contact with the mucosa delivers its active ingredient slower than the spray solution but faster than the lozenges at initial time points, leading to a better performance up to 0.25 h compared to the lozenges, after which it is similar (0.5 h up to 2 h). The viscosity of the gel intentionally limits its capacity to deliver the product rapidly compared to spray solutions, leading to a longer and more constant release closer to that seen for lozenges.
Finally, to better understand the potential link between these earlier pAUCs and the onset of action, a correlation was performed between the absolute values of AUC0.25h and AUC0.5h for all three pharmaceutical forms and clinical efficacy data from published literature [25]. This analysis showed a very clear and strong correlation between early pAUC values and the onset of action (Table 4). Thus, these early partial AUCs (AUC0.25h and AUC0.5h), in contrast to later values (AUC1h and AUC2h), distinguish between formulations (sprays, lozenges, and granules) that have a similar overall extent of absorption and similar peak plasma concentrations but have been shown to have different times to onset of action in therapeutic trials. The fact that these AUC0.25h and AUC0.5h values represent no more than 1 to 5% of the total AUC suggests that the early onset of pain relief is a response to immediate local absorption at the site of action rather than a systemic effect. This, in turn, would support the use of early pAUCs for clinical effect correlation of locally applied, locally acting products and for head-to-head comparisons, establishing the bioequivalence of different formulations.
Partial AUCs are already currently used by some agencies to better characterise the PK profiles of certain products. For instance, the FDA recommends the use of pAUC as an exposure measure in a number of product-specific bioequivalence guidelines, mainly for certain modified-release (MR) products in which the different phases of release correspond to a clinical effect [18]. European guidelines on bioequivalence of MR products mention the need to include additional parameters, including initial and terminal pAUCs, particularly when a low extent of accumulation is expected [17]. Recently, the importance of the use of pAUC for MR products has been shown by Soares et al. [34], who evaluated 117 studies of prolonged-release products already approved by the Brazilian authority (ANVISA) and found that 24 (20%) failed to demonstrate bioequivalence for the relevant pAUC parameter. Partial AUCs are, under certain circumstances, also a recognised and established metric for treatment comparisons for orally inhaled products [35]. Recently, the draft ICH M13A guideline [22] pointed out that in some situations, Cmax and AUC(0−t) may be insufficient to adequately assess bioequivalence between two products, in particular when early onset of action is clinically relevant. In these cases, partial AUC may be applied, most typically from the time of drug administration until a predetermined time point that is related to a clinically relevant pharmacodynamic (PD) measure.
The data presented above show that for certain products, such as locally applied, locally acting NSAIDs for use in the oral cavity and throat, pAUCs provide useful data that allow discrimination between formulations. Moreover, these data may be more clinically relevant than those gained through, e.g., charcoal blocks.
It is acknowledged that the exact PK/PD profile of locally applied flurbiprofen has not been reliably established as the presented work is based on parallel study comparisons and retrospective data analyses. The link between PK, local concentrations, and onset of action should be further elucidated in a single study in order to confirm the potential use of early pAUCs as a surrogate for comparison of early pain relief in products of this type.

5. Conclusions

While the ultimate proof of similarity across different formulations of locally applied and locally acting drugs in the mouth and throat usually requires therapeutic studies, the comparison of pAUCs provides a promising alternative. The possibility of using PK data, in particular pAUCs, with associated PD correlations to assess the therapeutic equivalence of two formulations containing similar doses of active for local application and local activity in the mouth and throat should be reflected in the equivalence guidelines.

6. Patents

The information on gel spray has been submitted for a patent, and further details on this patented formulation are not available for this manuscript.

Author Contributions

Conceptualization and methodology, J.-M.C. and V.P.; V.P., formal analysis, data curation, writing—original draft preparation; M.V. Conceptualization, validation, investigation, resources, writing—review and editing, supervision; A.K. and G.C., writing—review and editing and project administration. All authors have read and agreed to the published version of the manuscript.

Funding

This research was funded by Reckitt Benckiser Healthcare Limited.

Institutional Review Board Statement

Each of the studies involving humans mentioned in the paper was conducted in accordance with the Declaration of Helsinki and approved by the relevant Institutional Review Board (or Ethics Committee). Study EudraCT 2018-003175-36 was approved by the Medisch Ethische ToetsingsCommissie of the Foundation ‘Evaluation of Ethics in Biomedical Research’ (Stichting Beoordeling Ethick Biomedisch Onderzoek), Assen, The Netherlands, on 07 Dec 2018. The registered study number is 0334502. Study EudraCT 2011-003332-31 was approved by the Edinburgh Independent Ethics Committee for Medical Research on 19 Sep 2011. The registered study number is TH1104. Study EudraCT 2008-005177-34 was approved by the Bioethics Committee at the District Medical Chamber in Krakow (Komisja Bioetyczna przy Okręgowej Izbie Lekarskiej w Krakowie). The registered study number is TH0812.

Informed Consent Statement

Informed consent was obtained from all subjects involved in the studies considered for the data analysis in this paper.

Data Availability Statement

Data are available on request for scientific reasons.

Acknowledgments

Medical writing assistance was provided by regenold GmbH. Mariam Aslam supported the coordination between stakeholders to complete this paper on behalf of Reckitt Healthcare Limited.

Conflicts of Interest

A.K. and G.C. are full-time paid employees of Reckitt Health Ltd. VP and JMC received funding for analysis and consultancy.

References

  1. EMA. Guideline on Equivalence Studies for the Demonstration of Therapeutic Equivalence for Locally Applied, Locally Acting Products in the Gastrointestinal Tract: CPMP/EWP/239/95 Rev. 1, Corr.1*. Available online: https://www.ema.europa.eu/en/documents/scientific-guideline/guideline-equivalence-studies-demonstration-therapeutic-equivalence-locally-applied-locally-acting_en.pdf (accessed on 27 February 2023).
  2. EMA. Note for Guidance on the Clinical Requirements for Locally Applied, Locally Acting Products Containing Known Constituents: CPMP/EWP/239/95 Final. Available online: https://www.ema.europa.eu/en/documents/scientific-guideline/note-guidance-clinical-requirements-locally-applied-locally-acting-products-containing-known_en.pdf (accessed on 27 February 2023).
  3. Efe, T.; Sagnak, E.; Roessler, P.P.; Getgood, A.; Patzer, T.; Fuchs-Winkelmann, S.; Peterlein, C.D.; Schofer, M.D. Penetration of topical diclofenac sodium 4% spray gel into the synovial tissue and synovial fluid of the knee: A randomised clinical trial. Knee Surg. Sports Traumatol. Arthrosc. 2014, 22, 345–350. [Google Scholar] [CrossRef] [PubMed]
  4. Turner, R.; Wevrett, S.R.; Edmunds, S.; Brown, M.; Kulasekaran, A.; Adegoke, O.; Farrah, J. Penetration of Flurbiprofen from a Locally Applied Sore Throat Lozenge and Spray into Cadaveric Human Pharynx Tissue: A Novel ex vivo Model and Microautoradiography Method. Clin. Pharmacol. 2021, 13, 13–20. [Google Scholar] [CrossRef] [PubMed]
  5. Haroutiunian, S.; Drennan, D.A.; Lipman, A.G. Topical NSAID therapy for musculoskeletal pain. Pain Med. 2010, 11, 535–549. [Google Scholar] [CrossRef] [PubMed]
  6. Rannou, F.; Pelletier, J.-P.; Martel-Pelletier, J. Efficacy and safety of topical NSAIDs in the management of osteoarthritis: Evidence from real-life setting trials and surveys. Semin. Arthritis Rheum. 2016, 45, S18–S21. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  7. Derry, S.; Moore, R.A.; Gaskell, H.; McIntyre, M.; Wiffen, P.J. Topical NSAIDs for acute musculoskeletal pain in adults. Cochrane Database Syst. Rev. 2015, 2015, CD007402. [Google Scholar] [CrossRef] [PubMed]
  8. Holt, R.J.; Taiwo, T.; Kent, J.D. Bioequivalence of diclofenac sodium 2% and 1.5% topical solutions relative to oral diclofenac sodium in healthy volunteers. Postgrad. Med. 2015, 127, 581–590. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  9. Hagen, M.; Baker, M. Skin penetration and tissue permeation after topical administration of diclofenac. Curr. Med. Res. Opin. 2017, 33, 1623–1634. [Google Scholar] [CrossRef] [Green Version]
  10. Tugwell, P.S.; Wells, G.A.; Shainhouse, J.Z. Equivalence study of a topical diclofenac solution (pennsaid) compared with oral diclofenac in symptomatic treatment of osteoarthritis of the knee: A randomized controlled trial. J. Rheumatol. 2004, 31, 2002–2012. [Google Scholar]
  11. Roth, S.H.; Fuller, P. Diclofenac topical solution compared with oral diclofenac: A pooled safety analysis. J. Pain Res. 2011, 4, 159–167. [Google Scholar] [CrossRef] [Green Version]
  12. Kai, S.; Kondo, E.; Kawaguchi, Y.; Kitamura, N.; Yasuda, K. Flurbiprofen concentration in soft tissues is higher after topical application than after oral administration. Br. J. Clin. Pharmacol. 2013, 75, 799–804. [Google Scholar] [CrossRef] [Green Version]
  13. Turner, R.; Wevrett, S.R.; Edmunds, S.; Brown, M.B.; Atkinson, R.; Adegoke, O.; Kulasekaran, A.; Shea, T. Determination of the Permeation and Penetration of Flurbiprofen into Cadaveric Human Pharynx Tissue. Clin. Pharmacol. 2020, 12, 13–20. [Google Scholar] [CrossRef] [Green Version]
  14. de Looze, F.; Russo, M.; Bloch, M.; Montgomery, B.; Shephard, A.; Smith, G.; Aspley, S. Efficacy of flurbiprofen 8.75 mg spray in patients with sore throat due to an upper respiratory tract infection: A randomised controlled trial. Eur. J. Gen. Pract. 2016, 22, 111–118. [Google Scholar] [CrossRef] [Green Version]
  15. Schachtel, B.; Aspley, S.; Shephard, A.; Shea, T.; Smith, G.; Sanner, K.; Savino, L.; Rezuke, J.; Schachtel, E. Onset of action of a lozenge containing flurbiprofen 8.75 mg: A randomized, double-blind, placebo-controlled trial with a new method for measuring onset of analgesic activity. Pain 2014, 155, 422–428. [Google Scholar] [CrossRef] [PubMed]
  16. Russo, M.; Bloch, M.; de Looze, F.; Morris, C.; Shephard, A. Flurbiprofen microgranules for relief of sore throat: A randomised, double-blind trial. Br. J. Gen. Pract. 2013, 63, e149-55. [Google Scholar] [CrossRef] [Green Version]
  17. EMA. Guideline on the Pharmacokinetic and Clinical Evaluation of Modified Release Dosage Forms: EMA/CHMP/EWP/280/96 Rev1. Available online: https://www.ema.europa.eu/en/documents/scientific-guideline/guideline-pharmacokinetic-clinical-evaluation-modified-release-dosage-forms_en.pdf (accessed on 27 February 2023).
  18. FDA. Bioequivalence Studies with Pharmacokinetic Endpoints for Drugs Submitted Under an Abbreviated New Drug Application: FDA-2013-D-1464. Available online: https://www.fda.gov/regulatory-information/search-fda-guidance-documents/bioequivalence-studies-pharmacokinetic-endpoints-drugs-submitted-under-abbreviated-new-drug (accessed on 27 February 2023).
  19. TH0918 Report. An Open-Label, Randomised, Single Dose, 5-Way Crossover Pilot Study to Compare the Rate and Extent of Absorption of a 8.75 mg Flurbiprofen Lozenge with Flavour and Excipient Base Variants of a 8.75 mg Flurbiprofen Spray: EudraCT/IND Number 2010-022899-32. 2011. Available online: https://www.clinicaltrialsregister.eu/ctr-search/rest/download/result/attachment/2010-022899-32/1/16101 (accessed on 27 February 2023).
  20. Lee, H.-I.; Choi, C.-I.; Byeon, J.-Y.; Lee, J.-E.; Park, S.-Y.; Kim, Y.-H.; Kim, S.-H.; Lee, Y.-J.; Jang, C.-G.; Lee, S.-Y. Simultaneous determination of flurbiprofen and its hydroxy metabolite in human plasma by liquid chromatography-tandem mass spectrometry for clinical application. J. Chromatogr. B Analyt. Technol. Biomed. Life Sci. 2014, 971, 58–63. [Google Scholar] [CrossRef]
  21. Mano, N.; Narui, T.; Nikaido, A.; Goto, J. Separation and determination of diastereomeric flurbiprofen acyl glucuronides in human urine by LC/ESI-MS with a simple column-switching technique. DMPK 2002, 17, 142–149. [Google Scholar] [CrossRef] [PubMed]
  22. ICH. Bioequivalence for Immediate-Release Solid Oral Dosage Forms M13A. Available online: https://www.fda.gov/regulatory-information/search-fda-guidance-documents/m13a-bioequivalence-immediate-release-solid-oral-dosage-forms (accessed on 13 February 2023).
  23. Duquesnoy, C.; Lacey, L.F.; Keene, O.N.; Bye, A. Evaluation of different partial AUCs as indirect measures of rate of drug absorption in comparative pharmacokinetic studies. Eur. J. Pharm. Sci. 1998, 6, 259–264. [Google Scholar] [CrossRef] [PubMed]
  24. Cardot, J.-M.; Davit, B.M. In vitro-in vivo correlations: Tricks and traps. AAPS J. 2012, 14, 491–499. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  25. de Looze, F.; Shephard, A.; Smith, A.B. Locally Delivered Flurbiprofen 8.75 mg for Treatment and Prevention of Sore Throat: A Narrative Review of Clinical Studies. J. Pain Res. 2019, 12, 3477–3509. [Google Scholar] [CrossRef] [Green Version]
  26. Farrar, J.T.; Portenoy, R.K.; Berlin, J.A.; Kinman, J.L.; Strom, B.L. Defining the clinically important difference in pain outcome measures. Pain 2000, 88, 287–294. [Google Scholar] [CrossRef]
  27. Klinge, S.A.; Sawyer, G.A. Effectiveness and safety of topical versus oral nonsteroidal anti-inflammatory drugs: A comprehensive review. Physician Sportsmed. 2013, 41, 64–74. [Google Scholar] [CrossRef] [PubMed]
  28. Ware, J.; Coutinho, G.; Smith, A.B.; Tselenti, E.; Kulasekaran, A. The effects of acute sore throat and cough on health-related quality of life (HRQOL) in the 2020 US general population. Eur. Respir. J. 2021, 58, PA3130. [Google Scholar]
  29. Moore, R.A.; Derry, S.; Straube, S.; Ireson-Paine, J.; Wiffen, P.J. Validating speed of onset as a key component of good analgesic response in acute pain. Eur. J. Pain 2015, 19, 187–192. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  30. Loisios-Konstantinidis, I.; Paraiso, R.L.M.; Fotaki, N.; McAllister, M.; Cristofoletti, R.; Dressman, J. Application of the relationship between pharmacokinetics and pharmacodynamics in drug development and therapeutic equivalence: A PEARRL review. J Pharm Pharmacol 2019, 71, 699–723. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  31. Burova, N.; Bychkova, V.; Shephard, A. Improvements in throat function and qualities of sore throat from locally applied flurbiprofen 8.75 mg in spray or lozenge format: Findings from a randomized trial of patients with upper respiratory tract infection in the Russian Federation. J. Pain Res. 2018, 11, 1045–1055. [Google Scholar] [CrossRef] [Green Version]
  32. Radkova, E.; Burova, N.; Bychkova, V.; DeVito, R. Efficacy of flurbiprofen 8.75 mg delivered as a spray or lozenge in patients with sore throat due to upper respiratory tract infection: A randomized, non-inferiority trial in the Russian Federation. J. Pain Res. 2017, 10, 1591–1600. [Google Scholar] [CrossRef] [Green Version]
  33. Li, H.; Mandema, J.; Wada, R.; Jayawardena, S.; Desjardins, P.; Doyle, G.; Kellstein, D. Modeling the onset and offset of dental pain relief by ibuprofen. J. Clin. Pharmacol. 2012, 52, 89–101. [Google Scholar] [CrossRef]
  34. Soares, K.C.C.; Chiann, C.; Storpirtis, S. Assessment of the impact of partial area under the curve in a bioavailability/bioequivalence study on generic prolonged-release formulations. Eur. J. Pharm. Sci. 2022, 171, 106127. [Google Scholar] [CrossRef]
  35. EMA. Clinical Pharmacology and Pharmacokinetics: Questions and Answers: Topic 3.3. Available online: https://www.ema.europa.eu/en/human-regulatory/research-development/scientific-guidelines/clinical-pharmacology-pharmacokinetics/clinical-pharmacology-pharmacokinetics-questions-answers (accessed on 7 February 2023).
Figure 1. Plasma concentrations after a single therapeutic dose of flurbiprofen (8.75 mg) delivered to the back of the throat in the pharmaceutical form of spray gel (A and B) and a reference spray solution.
Figure 1. Plasma concentrations after a single therapeutic dose of flurbiprofen (8.75 mg) delivered to the back of the throat in the pharmaceutical form of spray gel (A and B) and a reference spray solution.
Pharmaceutics 15 01863 g001
Figure 2. Plasma concentrations after a single therapeutic dose of flurbiprofen (8.75 mg) delivered to the back of the throat in the pharmaceutical form of spray solutions (A and B) and lozenges.
Figure 2. Plasma concentrations after a single therapeutic dose of flurbiprofen (8.75 mg) delivered to the back of the throat in the pharmaceutical form of spray solutions (A and B) and lozenges.
Pharmaceutics 15 01863 g002
Figure 3. Plasma concentrations after a single therapeutic dose of flurbiprofen (8.75 mg) delivered in the mouth in the pharmaceutical form of granules and lozenges.
Figure 3. Plasma concentrations after a single therapeutic dose of flurbiprofen (8.75 mg) delivered in the mouth in the pharmaceutical form of granules and lozenges.
Pharmaceutics 15 01863 g003
Table 1. Parallel interstudy comparison of the AUC0−t and Cmax of three pharmaceutical forms of flurbiprofen after a single therapeutic dose with the reference values of the spray solution.
Table 1. Parallel interstudy comparison of the AUC0−t and Cmax of three pharmaceutical forms of flurbiprofen after a single therapeutic dose with the reference values of the spray solution.
VariableTest Product (8.75 mg)Ratio vs. Reference Value %90% CIp Value
Ln(Cmax)Lozenges98.9186.78–112.750.89
Granules86.3175.72–98.390.06
Spray gel A91.6980.44–104.510.87
Spray gel B89.4178.44–101.920.93
Ln(AUC0−t)Lozenges101.6189.71–115.100.83
Granules96.4885.18–109.280.63
Spray gel A97.3385.93–110.250.81
Spray gel B93.0682.16–105.400.89
Table 2. Parallel interstudy comparison of the AUC1h and AUC2h of three pharmaceutical forms of flurbiprofen after a single therapeutic dose with the reference values of the spray solution.
Table 2. Parallel interstudy comparison of the AUC1h and AUC2h of three pharmaceutical forms of flurbiprofen after a single therapeutic dose with the reference values of the spray solution.
VariableTest Product 8.75 mgRatio vs. Reference Value %90% CIp Value
Ln(AUC2h)Lozenges98.9587.66–111.690.89
Granules83.2573.76–93.970.01
Spray gel A92.1281.61–103.980.87
Spray gel B88.5578.46–99.950.87
Ln(AUC1h)Lozenges93.8380.58–109.260.49
Granules65.4956.24–76.26>0.001
Spray gel A84.1272.24–97.960.42
Spray gel B85,5473.45–99.610.85
Table 3. Parallel interstudy comparison of the AUC0.25h and AUC0.5h of three pharmaceutical forms of flurbiprofen after a single therapeutic dose with the reference values of the spray solution.
Table 3. Parallel interstudy comparison of the AUC0.25h and AUC0.5h of three pharmaceutical forms of flurbiprofen after a single therapeutic dose with the reference values of the spray solution.
VariableTest Product 8.75 mgRatio vs. Reference Value %90% CIp Value
Ln(AUC0.25h)Lozenges59.8643.99–81.470.01
Granules25.6518.85–34.91>0.001
Spray gel A65.1847.89–88.700.002
Spray gel B73.6054.08–100.170.86
Ln(AUC0.5h)Lozenges82.4066.81–101,630.13
Granules46.5237.72–57.38>0.001
Spray gel A73.2759.40–90.360.08
Spray gel B79.8864.77–98.520.85
Table 4. Parallel interstudy comparison of the AUC0.25h and AUC0.5h of the respective pharmaceutical forms of flurbiprofen and their correlation with efficacy parameter onset of action, specifically time to clinically meaningful pain relief [25].
Table 4. Parallel interstudy comparison of the AUC0.25h and AUC0.5h of the respective pharmaceutical forms of flurbiprofen and their correlation with efficacy parameter onset of action, specifically time to clinically meaningful pain relief [25].
VariableTest Product 8.75 mgpAUC Mean
(ng∗h/mL)
Onset of Action (min)Correlation
Coefficient
Ln(AUC0.25h)Flurbiprofen spray solution84.6799375200.99993962
Flurbiprofen lozenges48.169071726
Flurbiprofen granules24.512949430
Ln(AUC0.5h)Flurbiprofen spray solution301.695563200.94568955
Flurbiprofen lozenges242.74330226
Flurbiprofen granules152.58426630
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Share and Cite

MDPI and ACS Style

Perlik, V.; Kulasekaran, A.; Coutinho, G.; Votava, M.; Cardot, J.-M. Relationship between Pharmacokinetic Profile and Clinical Efficacy Data of Three Different Forms of Locally Applied Flurbiprofen in the Mouth/Throat. Pharmaceutics 2023, 15, 1863. https://doi.org/10.3390/pharmaceutics15071863

AMA Style

Perlik V, Kulasekaran A, Coutinho G, Votava M, Cardot J-M. Relationship between Pharmacokinetic Profile and Clinical Efficacy Data of Three Different Forms of Locally Applied Flurbiprofen in the Mouth/Throat. Pharmaceutics. 2023; 15(7):1863. https://doi.org/10.3390/pharmaceutics15071863

Chicago/Turabian Style

Perlik, Vit, Anuradha Kulasekaran, Graça Coutinho, Martin Votava, and Jean-Michel Cardot. 2023. "Relationship between Pharmacokinetic Profile and Clinical Efficacy Data of Three Different Forms of Locally Applied Flurbiprofen in the Mouth/Throat" Pharmaceutics 15, no. 7: 1863. https://doi.org/10.3390/pharmaceutics15071863