Next Article in Journal
Recycled Cellulose Fiber Reinforced Plaster
Next Article in Special Issue
Applications of AOTF Spectrometers in In Situ Lunar Measurements
Previous Article in Journal
The Influence of External Environmental Conditions on Properties of Ceramic Building Materials with Waste Material Additives
Previous Article in Special Issue
Acousto-Optic Cells with Phased-Array Transducers and Their Application in Systems of Optical Information Processing
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

Spectral Imaging Experiments with Various Optical Schemes Based on the Same AOTF

1
Scientific and Technological Center of Unique Instrumentation Russian Academy of Sciences, Butlerova Str. 15, 117342 Moscow, Russia
2
Laser and Optical-Electronic Systems Department, Bauman Moscow State Technical University (National Research University), 2-nd Baumanskaya Str. 5, 105005 Moscow, Russia
3
Institute of Information Technologies and Computer Science, Moscow Power Engineering University (National Research University), Krasnokazarmennaya 14, 111250 Moscow, Russia
4
Moscow Institute of Physics and Technology, National Research University, 9 Institutskiy per., Dolgoprudny, 141701 Moscow, Russia
5
Federal Scientific Research Center “Crystallography and Photonics”, Russian Academy of Sciences, 119333 Moscow, Russia
*
Author to whom correspondence should be addressed.
Materials 2021, 14(11), 2984; https://doi.org/10.3390/ma14112984
Submission received: 30 April 2021 / Revised: 26 May 2021 / Accepted: 29 May 2021 / Published: 31 May 2021
(This article belongs to the Special Issue Acousto-Optical Spectral Technologies)

Abstract

:
Spectral image filtration by means of acousto-optical tunable filters (AOTFs) has multiple applications. For its implementation, a few different optical schemes are in use. They differ in image quality, number of coupling components, dimensions and alignment complexity. To choose the optical system of AOTF-based spectral imager properly, many factors have to be considered. Though various schemes of acousto-optic (AO) filtration have been tested and discussed, their comparative analysis has not been reported up to now. In this study, we assembled the four most popular schemes (confocal, collimating, tandem and double-path) using the same AO cells and experimentally compared their main features. Depending on the application, each scheme may be the basis of compact cost-effective spectral imaging devices.

1. Introduction

AOTFs have become a popular tool for various hyperspectral imaging applications in biomedicine [1,2], agriculture [3,4], aerospace [5,6] and other fields. Based on anisotropic Bragg diffraction of wide-band light by ultrasound in crystalline media, these spectral elements provide a good combination of optical (high spectral and spatial resolution, wide tuning range, etc.) and technical (compactness, absence of moving parts, etc.) features [7].
The imaging capabilities of AOTF-based systems are defined by multiple factors. Most of them, e.g., geometry of AO interaction, shape of AO cell (AOC) and structure of ultrasound beam [8,9,10], have been examined and discussed in detail. Besides these AOTF characteristics, the optical scheme of AO spectral filtration has a strong influence on the features of AOTF-based images [11]. In practice, a few different schemes are used.
A typical AOTF configuration includes a single AOC located between two polarizers crossed with respect to each other [12]. More effective in terms of spectral resolution and residual image distortion are double AOTFs that may consist of tandem AOCs [13] or utilize a double light pass through a single AOC by means of optical feedback [14] and back reflection [15].
Moreover, there are three image formation methods common for all AOTFs: collimating, confocal and convergent [10]. Collimating (telescopic) scheme is the most common and the simplest one and provides high image quality and spectral resolution. However, the non-uniformity of the central wavelength of filtered light across the field of view results in a specific image spatio-spectral distortion [16]. Confocal telecentric scheme, which forms the image inside AOC, is free from this drawback but leads to visualization of the inhomogeneous ultrasound structure in the filtered image and to spectral resolution degradation [17]. Specific AO aberrations (distortion and chromatic image drift) are present in both schemes. Converging scheme is used quite rarely [18].
Tandem AOTF consisting of two identical AOCs provides higher spatial and spectral resolution, but at the same time, lower light transmission and larger dimensions. Normally, tandem AOTF utilizes a collimating scheme to avoid additional couplers necessary for the confocal one. To reduce the dimensions and price of a tandem AOTF, a single AOC operating in double-pass collimating scheme can be used [19].
All these optical schemes differ in image quality, number of coupling components, dimensions, alignment complexity and other features. For each specific task and for each AOC, it is necessary to optimize the optical system for AO image filtration. Though the schemes mentioned above have been already tested and discussed, their comparative analyses have not been reported up to now. We need to extract the characteristic features of each scheme by separating them from intrinsic features of AOC itself.
In this study, we assemble, test and analyze four various schemes (Figure 1). Two of them are commonly used schemes: collimating (coll) and confocal (conf) ones. Two others imply two-stage light diffraction: by two AOC in series (tandem configuration) and by the same AOC (double-pass configuration). All of them are described in Section 2. The comparison procedure and results are presented in Section 3, while the general conclusions are presented in the last section.

2. Materials and Methods

In the experiments, we used a typical AOC made from paratellurite (α-TeO2), which is the most widely used AO uniaxial crystal. The geometry of this AOC is optimized for minimization of the chromatic image drift in the confocal optical scheme. It provides good spectral and spatial resolution and may be used in a wide spectral range [20]. Residual angular dispersion is 0.4°. The AOC has a cut angle γ = 7° (Figure 2). The wide-aperture diffraction geometry of e-polarized light [8,12] is realized for incident angle θ = 73.85°. Basic parameters: the piezotransducer length L = 12 mm, clear input aperture is 10 × 12 mm2, the angular aperture is 4° × 4°. An incident light beam must be directed normally to the front facet. The back-facet inclination angle is with respect to incident facet β = 2.3°. By varying the acoustic frequency within intervals of 60–110 MHz, one can tune the wavelength of filtered light in the range 450–850 nm. Driving acoustic power interval is 2.3–2.5 W. It is adjusted to equalize the AOTF’s light transmission in this range. In tandem AOTF two identical AOCs of this type was used.
In all the experiments presented below (Figure 3, Figure 4, Figure 5 and Figure 6), we used both standard and custom optical components. For image acquisition, the camera TheImagingSource DMK 37BUX178 with 1/1.8″ 6.3 MP CMOS sensor was installed. Depending on the inspected object, two different lenses L0 were utilized: an infinity-corrected microscope objective Carl Zeiss Planachromat 10/0.25 and photography lens Minolta MAXXUM 135/2.8. Afocal system L1, L2 consists of two identical standard lenses: 25 mm board lenses TheImagingSource TBL 25 or Thorlabs AC127-025-AB achromatic doublets. Focusing lens L3 is 75 mm Kowa LM75HC lens or Thorlabs AC127-075-AB achromatic doublet. Focusing lens in confocal scheme is 35 mm board lens TheImagingSource TBL 35. Coupling lenses L4 and L5 are 36 mm doublets specially designed and manufactured to compensate for the chromatic focal shift introduced by the AO cell in the confocal scheme. Lens L7 in the last setup is a 50 mm achromatic doublet.
A single-crystal single-pass collimating scheme (S-coll) is comprised of the following input optical part elements: input lens L0, field stop A1 inside the afocal system L1–L2, which define the collimated beam divergence preventing sensor irradiation by non-diffracted (unfiltered) light (Figure 3). An output lens L3 forms the spectral image on the sensor S.
Single-crystal single-pass confocal scheme (S-conf) comprises two similar optical systems in the input and output: a pair of lenses with intermediate diaphragm (Figure 4). The input system forms an intermediate image inside the AOC, while the output projects its filtered component onto the sensor S. The aperture stop A2 defines the convergence angle and output stop A3 blocks the non-diffracted (unfiltered) beam. Coupling lenses L4 and L5 are 36 mm custom-designed to compensate for the chromatic focal shift introduced by the AO cell. Other components are standard machine vision lenses.
Double-crystal single-pass (tandem) collimating scheme (T-coll) needs an afocal system L2–L3 in the input and output focusing lens L3 to transfer the object image into the sensor S (Figure 5). Tandem AOTF consists of two identical AO cells and three crossed Glan–Taylor calcite polarizers P1, P2, and P3. The second AO cell is rotated by 180° with respect to the first one. The polarizers are necessary to block the non-diffracted light beam leaving the filter at the same direction as the twice-diffracted one, whereas the lateral separation is insufficient due to the rather small deflecting angle. As the extinction ratio of polarizers is not always enough to eliminate non-diffracted light completely, we additionally utilized a field stop A1.
Since AO cells are identical and opposite turned, the same wide-aperture diffraction mode is realized in both AO cells, and, thus, image aberrations of distortion and chromatic drift are compensated. The drawback of the scheme is significantly increased energy losses. The advantages are higher spectral and spatial resolution.
Double-pass single-crystal collimating scheme (D-coll) contains beamsplitter BS, which divides it into three parts (Figure 6). The input optical system consists of a lens L0 and the afocal system L1-L2 with the field stop A1 inside. The spectral unit additionally comprises an AO cell, a retroreflector (lens L6 with the mirror M), which directs back the diffracted light emerging from AO cell, while the rest of the light does not return. The reflected spectrally selected light diffracts in the AO cell and is filtered one more time. In terms of ray tracing and spectral selection, the double-pass scheme is very similar to the tandem one with two identical AO cells.
In this scheme, we used a Thorlabs BSF10-A beamsplitter. A plate beamsplitter is preferable, as reflections from the edges of that usually degrade the image contrast. In general, the normal incidence on any flat surface located after BS should be avoided to protect the sensor from stray light that would reduce the image contrast. Even AR coating does not fully solve this problem, since the filtered light has a narrow spectrum and therefore its intensity is much less than the intensity of unfiltered light. To minimize stray light, the AOC is slightly tilted in the sagittal plane and its faces are coated with the antireflection coating. These measures, however, do not ensure solving the problem, because usually the tilt angle is small (otherwise it will cause optical aberrations, in particular astigmatism) and so reflections emerging in a wide spectral range make the selection of narrowband filtered light difficult. For this reason, polarizers are not suitable in this scheme. To solve the problem, we placed a field stop A1, like in the S-coll scheme (Figure 3), and thus have managed to adjust the scheme.
Generally, in this scheme, the transmission is significantly reduced by the beamsplitter, but there is an additional optical channel which can be used for white-light imaging or auxiliary purposes. Therefore, the double-pass scheme is promising for multimodal operation. One can also use an optional beamsplitter and other considered schemes to provide a similar multimodal operation. However, this will lead to additional losses in all other schemes.

3. Experimental Results

Imaging capabilities of the described schemes were estimated with use of the test targets (Figure 7a) and specific color print (Figure 7b), for characterization of the spatial resolution, image distortion and spectral imaging contrast features.
For adequate comparison, one needs to equalize the image settings. To make the fields of view of all four systems roughly equal, we chose appropriate parameters of optical components L0–L6. The image longitudinal chromatic aberrations in the confocal scheme caused by the dispersion of the α-TeO2 crystal were compensated for by custom designed lenses L4 and L5. In collimating schemes, defocusing is negligible, and other optical elements were standard achromatic lenses.
To equalize the image brightness, we optimized the intensity of the halogen light source as well as the exposure time and gain of the camera. For example, images at wavelength 600 nm (Figure 8) were recorded with the same lighting conditions, but different exposure times: 0.01 s (S-call and S-conf), 0.25 s (T-coll) and 0.5 s (D-coll).
The spectral resolution was measured in the central part of the field of view by the diffraction grating spectrometer Ocean Insight FLAME.
As can be seen from Figure 8 and Figure 9, classical single-crystal single-pass schemes (S-coll and S-conf) demonstrate rather similar features. The main differences are higher spatial resolution in the confocal scheme, with lower spectral resolution [17,18]. Double-stage schemes (T-coll and D-coll) exhibit significantly higher spectral and spatial resolution, in exchange for higher light losses [19]. The double-pass scheme (D-coll) combines the advantages of single-crystal and tandem AOTFs (high resolution at lower cost), but requires laborious adjustment. Generally, all the schemes demonstrate their usability so a given AO cell can be used in different schemes.

4. Discussion and Conclusions

In this experimental study, we assembled four popular optical schemes for AOTF-based spectral imaging (Figure 3, Figure 4, Figure 5 and Figure 6). The same typical AOCs operating in a conventional wide-aperture mode were exploited. In this way, we eliminated the influence of the AOC’s features and highlighted the differences caused by the optical scheme. Though all schemes are capable of providing acceptable image quality, there are considerable differences in spectral and spatial resolution and other imaging characteristics and, therefore, adequate choice of the optical scheme permits optimization of particular features important for solving the problem.
A detailed analysis of the obtained images (Figure 8 and Figure 9) is presented in Table 1. These results should be interpreted primarily as a comparative assessment of the studied schemes and not as a merit of the best performance achievable in each scheme.
The spectral resolution, as expected, is higher in schemes with double AO filtering (D-coll and T-coll). The best image contrast at the selected spatial frequency (~15 mm−1) is achieved in a scheme with two AOCs (T-coll) and in a confocal scheme. The worst contrast is demonstrated by the double-pass scheme (D-coll), in our opinion, for two reasons. First is stray light. Second, light energy losses make it necessary to work with long exposure times, and therefore, along with the signal, the background light is also exposed for longer.
In the experiments, we used AOCs with the geometry optimized for the confocal scheme. In particular, it compensates for the chromatic drift by the optimal output facet angle. Therefore, the chromatic drift is almost absent in S-conf, but it is noticeable in S-coll. In double-pass schemes, chromatic drift is compensated. Its residual non-zero values can be explained by inaccurate alignment. Exposure time in double-pass schemes is significantly higher due to double absorption in the AOC, a narrower spectral bandwidth, and the presence of a beamsplitter (in the D-coll scheme). In all schemes, the AOCs are the most expensive components, followed by polarizers. Thus, T-coll scheme seems to be the most cost ineffective.
This study paves the way to understanding the main issues related to the optical de-sign of AOTF-based spectral imagers. A good result is always a compromise between the AOTF configuration and the complexity of the optical coupling and adjustment. Depending on the application, each scheme may be effective. The study results are helpful for the development of new AOTF-based imagers. Each scheme is worth detailed studying and discussing in a separate article.

Author Contributions

Conceptualization and original draft preparation, V.B. and A.M.; methodology, V.B.; formal analysis and supervision, V.P. and S.B.; investigation, G.M. and D.K.; resources, V.L.; review and editing, G.M., A.G. and V.P.; data processing, A.G.; funding acquisition, S.B. All authors have read and agreed to the published version of the manuscript.

Funding

This research was funded by the Russian Foundation for Basic Research, grant number 18-29-20095. The production of TeO2 crystals for AOCs was supported by Federal State Task Program of the Federal Scientific Research Center “Crystallography and Photonics”.

Institutional Review Board Statement

Not applicable.

Informed Consent Statement

Not applicable.

Data Availability Statement

The data presented in this study are available on request from the corresponding author.

Acknowledgments

This work was performed using the equipment of the Center for Collective Use of the Scientific and Technological Center of Unique Instrumentation of the Russian Academy of Sciences [21].

Conflicts of Interest

The funders had no role in the design of the study; in the collection, analyses, or interpretation of data; in the writing of the manuscript, or in the decision to publish the results.

References

  1. Lu, G.; Fei, B. Medical Hyperspectral Imaging: A Review. J. Biomed. Opt. 2014, 19, 010901. [Google Scholar] [CrossRef] [PubMed]
  2. Li, Q.; He, X.; Wang, Y.; Liu, H.; Xu, D.; Guo, F. Review of spectral imaging technology in biomedical engineering: Achievements and challenges. J. Biomed. Opt. 2013, 18, 100901. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  3. Inoue, Y.; Peñuelas, J. An AOTF-Based Hyperspectral Imaging System for Field Use in Ecophysiological and Agricultural Applications. Int. J. Remote Sens. 2001, 22, 3883–3888. [Google Scholar] [CrossRef]
  4. Hagen, N.; Kudenov, M.W. Review of Snapshot Spectral Imaging Technologies. Opt. Eng. 2013, 52, 090901. [Google Scholar] [CrossRef] [Green Version]
  5. Chanover, N.J.; Voelz, D.G.; Glenar, D.A.; Young, E.F. AOTF-Based Spectral Imaging for Balloon-Borne Platforms. J. Astron. Instrum. 2014, 3, 1440005. [Google Scholar] [CrossRef]
  6. Korablev, O.I.; Belyaev, D.A.; Dobrolenskiy, Y.S.; Trokhimovskiy, A.Y.; Kalinnikov, Y.K. Acousto-optic tunable filter spectrometers in space missions. Appl. Opt. 2018, 57, C103–C119. [Google Scholar] [CrossRef] [PubMed]
  7. Abdlaty, R.; Sahli, S.; Hayward, J.; Fang, Q. Hyperspectral imaging: Comparison of acousto-optic and liquid crystal tunable filters. Proc. SPIE 2018, 105732P. [Google Scholar] [CrossRef]
  8. Pozhar, V.; Machihin, A. Image Aberrations Caused by Light Diffraction via Ultrasonic Waves in Uniaxial Crystals. Appl. Opt. 2012, 51, 4513. [Google Scholar] [CrossRef] [PubMed]
  9. Voloshinov, V.B.; Yushkov, K.B.; Linde, B.B.J. Improvement in Performance of a TeO2 Acousto-Optic Imaging Spectrometer. J. Opt. A Pure Appl. Opt. 2007, 9, 341–347. [Google Scholar] [CrossRef] [Green Version]
  10. Balakshy, V.I. Application of Acousto-Optic Interaction for Holographic Conversion of Light Fields. Opt. Laser Technol. 1996, 28, 109–117. [Google Scholar] [CrossRef]
  11. Machikhin, A.; Batshev, V.; Pozhar, V. Aberration Analysis of AOTF-Based Spectral Imaging Systems. J. Opt. Soc. Am. A 2017, 34, 1109. [Google Scholar] [CrossRef] [PubMed]
  12. Chang, I.C. Noncollinear Acousto-optic Filter with Large Angular Aperture. Appl. Phys. Lett. 1974, 25, 370–372. [Google Scholar] [CrossRef]
  13. Machikhin, A.; Pozhar, V.; Batshev, V. Double-AOTF-Based Aberration-Free Spectral Imaging Endoscopic System for Bio-medical Applications. J. Innov. Opt. Health Sci. 2015, 08, 1541009. [Google Scholar] [CrossRef]
  14. Zhang, C.; Wang, H.; Zhang, Z.; Yuan, J.; Shi, L.; Sheng, Z.; Zhang, X. Narrowband Double-Filtering Hyperspectral Imaging Based on a Single AOTF. Opt. Lett. 2018, 43, 2126. [Google Scholar] [CrossRef] [PubMed]
  15. Mazur, M.M.; Pustovoit, V.I. Non-Collinear Acousto-Optical Filter. Russian Patent RU 2388030 C1, 27 April 2010. [Google Scholar]
  16. Gorevoy, A.V.; Machikhin, A.S.; Martynov, G.N.; Pozhar, V.E. Spatiospectral Transformation of Noncollimated Light Beams Diffracted by Ultrasound in Birefringent Crystals. Photon. Res. PRJ 2021, 9, 687–693. [Google Scholar] [CrossRef]
  17. Suhre, D.R.; Denes, L.J.; Gupta, N. Telecentric Confocal Optics for Aberration Correction of Acousto-Optic Tunable Filters. Appl. Opt. 2004, 43, 1255. [Google Scholar] [CrossRef] [PubMed]
  18. Machikhin, A.S.; Pozhar, V.E. Spatial and Spectral Image Distortions Caused by Diffraction of an Ordinary Polarised Light Beam by an Ultrasonic Wave. Quantum Electron. 2015, 45, 161–165. [Google Scholar] [CrossRef]
  19. Pustovoit, V.I.; Pozhar, V.E.; Mazur, M.M.; Shorin, V.N.; Kutuza, I.B.; Perchik, A.V. Double-AOTF Spectral Imaging System. Proc. SPIE 2005, 5953, 200–203. [Google Scholar] [CrossRef]
  20. Batshev, V.I.; Machikhin, A.S.; Kozlov, A.B.; Boritko, S.V.; Sharikova, M.O.; Karandin, A.V.; Pozhar, V.E.; Lomonov, V.A. Tunable Acousto-Optic Filter for the 450–900 and 900–1700 nm Spectral Range. J. Commun. Technol. Electron. 2020, 65, 800–805. [Google Scholar] [CrossRef]
  21. Center for Collective Use of STC UI RAS. Available online: http://ckp.ntcup.ru/ (accessed on 20 May 2021).
Figure 1. Typical schemes of AO filtration image: (a) single-crystal single-pass collimating scheme (S-coll); (b) double-crystal single-pass (tandem) collimating scheme (T-coll); (c) single-crystal single-pass confocal scheme (S-conf); (d) single-crystal double-pass collimating scheme (D-coll).
Figure 1. Typical schemes of AO filtration image: (a) single-crystal single-pass collimating scheme (S-coll); (b) double-crystal single-pass (tandem) collimating scheme (T-coll); (c) single-crystal single-pass confocal scheme (S-conf); (d) single-crystal double-pass collimating scheme (D-coll).
Materials 14 02984 g001
Figure 2. AO cell configuration. Group velocity v deviates from the ultrasound wave vector q due to walk-off effect; deflection of diffracted light wave vector kd from incident ki depends on θ and γ, while direction of output light beam is governed by back-facet inclination angle β. All the variants of experimental schemes have the same structure: object → input optics → AO spectral unit → output optics → photodetector.
Figure 2. AO cell configuration. Group velocity v deviates from the ultrasound wave vector q due to walk-off effect; deflection of diffracted light wave vector kd from incident ki depends on θ and γ, while direction of output light beam is governed by back-facet inclination angle β. All the variants of experimental schemes have the same structure: object → input optics → AO spectral unit → output optics → photodetector.
Materials 14 02984 g002
Figure 3. S-coll scheme. Breadboard model and optical beam-pass diagram.
Figure 3. S-coll scheme. Breadboard model and optical beam-pass diagram.
Materials 14 02984 g003
Figure 4. S-conf scheme. Breadboard model and optical beam-pass diagram.
Figure 4. S-conf scheme. Breadboard model and optical beam-pass diagram.
Materials 14 02984 g004
Figure 5. T-coll scheme. Breadboard model and optical beam-pass diagram.
Figure 5. T-coll scheme. Breadboard model and optical beam-pass diagram.
Materials 14 02984 g005
Figure 6. D-coll scheme. Breadboard model and optical beam-pass diagram.
Figure 6. D-coll scheme. Breadboard model and optical beam-pass diagram.
Materials 14 02984 g006
Figure 7. Spatial resolution test target (a) and color painting (b) used in the experiments.
Figure 7. Spatial resolution test target (a) and color painting (b) used in the experiments.
Materials 14 02984 g007
Figure 8. Spectral images of the test target and intensity cross sections along the red lines.
Figure 8. Spectral images of the test target and intensity cross sections along the red lines.
Materials 14 02984 g008
Figure 9. Spectral images of test color print recorded in four different schemes.
Figure 9. Spectral images of test color print recorded in four different schemes.
Materials 14 02984 g009
Table 1. Experimental results.
Table 1. Experimental results.
SchemeSpectral Resolution (at 600 nm), nmContrast at 15 mm−1Chromatic (450–850 nm) Drift, %Exposure Time (at 600 nm), sRel. Cost
S-coll4.80.505%0.011
S-conf5.50.600.5%0.011.1
T-coll30.651%0.252.5
D-coll3.80.200.5%0.51.5
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Share and Cite

MDPI and ACS Style

Batshev, V.; Machikhin, A.; Gorevoy, A.; Martynov, G.; Khokhlov, D.; Boritko, S.; Pozhar, V.; Lomonov, V. Spectral Imaging Experiments with Various Optical Schemes Based on the Same AOTF. Materials 2021, 14, 2984. https://doi.org/10.3390/ma14112984

AMA Style

Batshev V, Machikhin A, Gorevoy A, Martynov G, Khokhlov D, Boritko S, Pozhar V, Lomonov V. Spectral Imaging Experiments with Various Optical Schemes Based on the Same AOTF. Materials. 2021; 14(11):2984. https://doi.org/10.3390/ma14112984

Chicago/Turabian Style

Batshev, Vladislav, Alexander Machikhin, Alexey Gorevoy, Grigoriy Martynov, Demid Khokhlov, Sergey Boritko, Vitold Pozhar, and Vladimir Lomonov. 2021. "Spectral Imaging Experiments with Various Optical Schemes Based on the Same AOTF" Materials 14, no. 11: 2984. https://doi.org/10.3390/ma14112984

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop