Sensing Technology for Fish Freshness and Safety: A Review

by
Leonardo Franceschelli
1,*,
Annachiara Berardinelli
2,3,
Sihem Dabbou
3,
Luigi Ragni
4,5 and
Marco Tartagni
1
1
Department of Electrical, Electronic and Information Engineering, Guglielmo Marconi-University of Bologna, Via Dell’Università, 50, 47521 Cesena, Italy
2
Department of Industrial Engineering, University of Trento, Via Sommarive, 9, Povo, 38123 Trento, Italy
3
Centre Agriculture Food Environment, University of Trento, Via E. Mach, 1, S. Michele All’Adige, 38010 Trento, Italy
4
Department of Agricultural and Food Sciences, Alma Mater Studiorum, University of Bologna, Piazza Goidanich 60, 47521 Cesena, Italy
5
Interdepartmental Center for Industrial Agri-Food Research, University of Bologna, Via Q. Bucci 336, 47521 Cesena, Italy
*
Author to whom correspondence should be addressed.
Sensors 2021, 21(4), 1373; https://doi.org/10.3390/s21041373
Submission received: 20 January 2021 / Revised: 9 February 2021 / Accepted: 12 February 2021 / Published: 16 February 2021

Abstract

:
Standard analytical methods for fish freshness assessment are based on the measurement of chemical and physical attributes related to fish appearance, color, meat elasticity or texture, odor, and taste. These methods have plenty of disadvantages, such as being destructive, expensive, and time consuming. All these techniques require highly skilled operators. In the last decade, rapid advances in the development of novel techniques for evaluating food quality attributes have led to the development of non-invasive and non-destructive instrumental techniques, such as biosensors, e-sensors, and spectroscopic methods. The available scientific reports demonstrate that all these new techniques provide a great deal of information with only one test, making them suitable for on-line and/or at-line process control. Moreover, these techniques often require little or no sample preparation and allow sample destruction to be avoided.

1. Introduction

Consumer acceptance and food safety are key concerns for wholesalers and retailers of fresh fish and seafood products [1]. Fish and fish products are appreciated worldwide and have a very important role in a balanced human nutrition, providing several different nutrients and health benefits (protein, omega-3 fatty acids, vitamins). However, fresh fish and fish products are highly perishable products and are subject to a fast development of undesirable odors and flavors, and to a rapid decay process. This is due to their biological composition and several physical and chemical characteristics: low content of connective tissue, presence of autolytic enzymes, neutral pH, and high-water activity [2]. The time occurring between production and spoilage, caused by biochemical reactions and microbiological activity, defines the shelf life of fresh fish [3]. Spoilage of fish is a process of deterioration in the quality of fish that changes its appearance, odor, smell, taste, and meat texture. After a short initial spoilage stage, the increase of pH and nitrogen substances causes a multiplication of microorganisms, influencing the color of the eyeballs, body surface, abdomen, and muscle tone [4].
Reliable methods and techniques are required to evaluate the fish quality and spoilage [5]. Sensory attributes are the principal parameters of fish quality, and are related to fish appearance, color, meat elasticity or texture, odor, and taste. Based on changes in these variables, a series of sensory attributes like the brightness of appearance, meat color, gill color, meat elasticity, and smell could be used to classify freshness [6]. The most common sensory evaluation technique is the quality index method (QIM), based on the assessment of sensory quality parameters regarding mainly the skin, eyes, gills, and abdomen of raw fishes. This method, developed for each fish species, assesses parameters that significantly change during the shelf life and it is extensively used to estimate fish quality, although the support of other methods is required [7].
Quantitative chemical and physical techniques are correlated with sensory parameters to evaluate fish freshness and quality attributes. Chemical attributes are related to biochemical changes that occur in a fish after the harvest. Some of the most used parameters are specific spoilage organism (SSO) growth, lipid oxidation, peroxide value (PV), and the K value, based on adenosine triphosphate (ATP) degradation [8]. Physical properties like texture, electrical, and optical parameters could be used to assess the fish freshness [9,10,11]. Chemical and physical attributes correlate well with sensory attributes but can be affected by several factors, such as species, age, proximate composition, fishing area, season, and animal nutritional status [12,13].
The cited chemical and physical quantitative techniques have plenty of disadvantages, as they are destructive, expensive, time consuming, and require highly skilled operators. Moreover, they cannot be applied on-field or in on-line detection. Additionally, the fact that they are very time-consuming is detrimental, because fishes must often be put in the market the same day they are killed, given the fast spoilage time. The more innovative sensing techniques could overcome these problems, being rapid, cost-effective, and, except for biosensors, not invasive, permitting on-line detection to be achieved [5].
The review presents and describes the state of the art and future perspectives of these indirect techniques. Particularly, the text covers: biosensor techniques, e-sensing techniques, methods based on the fish dielectric properties, nuclear magnetic resonance (NMR), and spectroscopic techniques, including fluorescence, infrared, Raman, and hyperspectral imaging. Moreover, the review also covers the statistical analyses utilized in most of the presented papers. These algorithms, mainly utilized for the electronic and spectroscopic techniques, have a great and increasing importance in the sensors field, because they allow experimental data to be processed to create qualitative and quantitative models, enabling a fast and non-invasive measurement process. Almost all these algorithms are based on principal component analysis (PCA): it changes the original data space (defined by the measured variables) to a new space defined by the directions that contain the majority of data variance, called principal components (PCs). This analysis greatly reduces the data dimensions (usually from hundreds or thousands of variables to 5–10 PCs) and allows a better visualization of clusters and trends in the data. Evolutions of PCA allow the creation of both classification and regression models, such as the soft independent model of class analogy (SIMCA) algorithm, which applies PCA to different classes of data and then predicts the class of new measurements [14]. Regarding regression tools, the most used technique in chemometrics is partial least square regression (PLSR), developed by Wold in the late 1960s. It finds directions in the space (called latent variables) that explain at the same time the variance of both the experimental data and measured variable of interest [15]. Moreover, in the last years, algorithms like artificial neural networks (ANNs) were applied to nearly every field of food science, thanks to their high computational power and a consequent ability to handle more complex tasks [16]. The reported techniques are summarized in Figure 1, as well as the main statistical analyses used in these studies. The image also shows some of the most important practical characteristics of every method.

2. Analytical and Chemical Biosensors

Biosensors are devices able to measure a chemical or a biological reaction and to convert the response into an electrical signal [17]. These devices are functionally integrated and provide, through a biological recognition element, a (bio)transducer that recognizes the presence of a specific analyte in the reaction [18]. The signal generated by the biotransducer (based on heath absorption or light absorbance or redox reactions, or changes in the mass of reactant or products, etc.) produces changes in the electrical or electronic output that are transformed into a measurable signal by the transducers. The detector, finally, amplifies and processes the transduced signal [19]. According to the transducers, these devices can be classified as electrochemical, optical, thermal, and piezoelectric biosensors [20].
Concerning fish applications, electrochemical biosensors have been investigated to assess the presence of some compounds derived from the deterioration process. Between these compounds, the main ones are purine based like xhantine (Xa), produced by the degradation of adenosin-triphosphate (ATP); uric acid (UA) and hypoxhantine (HxA), both products of the action of xanthine oxidase on Xa; and gas molecules like trimethylamine (TMA) and dimethylacetamide (DMA), created by the conversion of trimethylamine oxide (TMAO) in fresh meat by spoilage bacteria, which also decompose urea and amino acids into ammonia.
Research performed by Tang et al. [21] showed that a sensitive amperometric sensor for xanthine can be created by modifying a carbon paste electrode with an electrospinning technique, obtaining carbon nanofibers (CNFs). Amperometric biosensors are based on the measurement of the electronic current produced by oxidation or reduction, and the use of nanomaterial greatly enhances the transduction of the biochemical reaction [22,23]. The CNF shows high catalytic properties towards the oxidation of Xa. The system was tested with crucian carp samples and the main results evidenced a linear relation between the measured current and the xanthine concentration, with a correlation coefficient of 0.99 and a limit of detection (LOD) of 20 nM.
To obtain a non-invasive measure of the content of ammonia in fishes, Heising et al. [24] monitored the changes of the ammonium content in an aqueous phase positioned in the headspace of the fish package, thanks to an ammonium selective electrode that measures changes in the electrical potential of water. Results showed that the trend of NH4+ measured in the aqueous phase was comparable with the trend of total volatile basic nitrogen (TVB-N) measured in the fish body. Two years later, Heising et al. [25] also investigated the use of simple and cheap electrode sensors, monitoring changes in the pH and conductivity of the aqueous phase. These electrodes are less selective with respect to the ammonium ones, but they can measure a broad range of substances related to the fish spoilage process. Results evidenced that the pH sensor could not be considered a good predictor of the overall sample quality, because the changes in the signal are too temperature dependent, whereas the conductivity sensor presented a pattern correlated with the increasing volatile amines content at all temperatures. More recently, Chang et al. [26] developed an amine gas sensor able to detect volatile amine gases in about 60 s from raw fish flesh. The gas sensor is based on a porous metal electrode, put on top of an organic semiconductor diode with nanostructures that increase the surface to volume ratio and therefore increase sensitivity. The fish samples were put in a bag of air, which was consequently dried and pumped through the sensor chamber, measuring the relative electric changes of air due to the increasing presence of ammonia, TMA, and DMA. Mackerel samples were used to confirm that the system was able to detect the expected influences of storage time, storage temperature, and different fish parts. Tests on tilapia and beltfish samples, compared with a traditional analysis of TVB-N, showed linear relations, with regression coefficients of 0.93, 0.96, and 0.97, respectively.
A system based on differential pulse voltammetry (DPV) was proposed by Vishnu et al. [27] for the simultaneous detection of three purine bases: HxA, Xa, and UA. In this configuration, a series of regular pulses are superimposed on a potential linear sweep or stairsteps, measuring the consequent changes in the current. Under optimal conditions, the sensor showed a linear behavior in the range of 6–30 µM, 8–36 µM, and 3–21 µM, respectively, with a current sensitivity of 0.921 µA µM-1, 1.742 µA µM-1, and 0.499 µA µM-1. Five different fish species (barracuda, lady fish, mackerel, blue catfish, and channel catfish) were used to test the device, with calculation of the recovery value. Acquisitions were performed before and after the addition of a known amount of one of the three purines to test the ability of the system to correctly measure the variation. The recovery value was about 100% in most of the cases, with the difference from the real value being not higher than 5%. These differences were explained by the strong biological activity of some species, which can block the active sites of the sensor.
Starting from an electrode of copper phosphate, characterized by a rapid production time (within 20 min), Lee et al. [28] set up an electrochemical histamine sensor with an innovative single-step dipping and coating technique. The obtained device, with a nanostructure similar to flakes, was tested in a Na2HPO4 solution with pH 8.5, showing good selectivity, an LOD of 3.0 ppm, and a detection range of 5–500 ppm. From 5 to 100 ppm, a very good linearity was found, with a correlation coefficient r of 0.999. The device was tested on fresh and rotten fish samples and compared with the commercialized liquid chromatography-mass spectroscopy, obtaining a deviation less than 10% between the two measures of the histamine concentration. Another interesting work is represented by the research conducted by Li et al. [29]. The authors studied the effect of various amounts of triethylamine on copper nitrate—benzenetricarboxylic acid (Cu-BTC) frameworks on the simultaneous determination of Xa and HxA in fish samples. Results showed that triethylamine had significant effects on the morphology, active response area, and electron transfer ability of Cu-BTC frameworks, enhancing the device sensibility. Tests on fish samples showed a linear behavior between the concentration and the oxidation peak of the two substances, in the range of 0–8 µM for Xa and 0–10 µM for HxA.
A particular and well-diffused family of biosensors is the enzymatic biosensors, based on the measurement of the reaction between a substance of interest and an enzyme. In particular, amperometric enzymatic biosensors, which are composed of an enzyme as a biological substance and an electrode as a transducer, are one of the most popular biosensors. In general, an amperometric enzymatic biosensor is an analytical device that combines an electroactive substance of interest with an enzyme immobilized on the electrode. An electrical signal gives the information regarding the presence and concentration of the substance and the results are calculated by a standard curve [19]. For fish freshness evaluation, chemical metabolites are the main target, especially ones related to ATP decomposition. Xanthine oxidase (XOD), which is involved in the reaction chain of ATP disintegration, is the main recognized element [5]. Thandavan et al. [30] developed a biosensor based on nanoparticles of iron oxide, which was able to measure nanomolar concentrations of Xa, enabling early detection of fish spoilage. XOD was linked to the nanoparticles, causing the electroreduction of hydrogen peroxide. The detection limit was found to be 0.4 nM, as well as a linear increase of the amperometric response of the sensor in the concentration range of 0.4–2.4 nM. Narang et al. [31] set up a system based on XOD immobilized on a nanocomposite platform of titanium dioxide nanoparticles and multi-walled carbon nanotubes. The device was characterized by an LOD of 0.5 µM and a linear behavior of the peak current for a xanthine concentration range of 0.5–500 µM, with a response time of about 30 s. Labeo fish samples were used to test the device, and a linear correlation (r = 0.99) with the Xa level measured by an enzymic colorimetric method was reported. Another example of amperometric enzymatic biosensors’ Xa application is represented by the work conducted by Borisova et al. [32] on hake samples. The system was composed of a glassy carbon electrode and a nanostructure sensing interface made by nanoparticles of polydopamine and platinum, where the enzyme of XOD was immobilized. This novel biosensor proved to have good reproducibility and repeatability, with a detection range of 50 nM–12 µM and an LOD of 13 nM. Additionally, Apetrei et al. [22] worked on a similar sensor for histamine biosensing, where the enzyme diamine-oxidase was immobilized on a carbon screen-printed electrode, modified with graphene and platinum nanoparticles. A low LOD (25.4 nM) and a linear range of 0.1–300 µM were observed in addition to correlations with the more traditional enzyme-linked immunosorbent assay (ELISA) method. More recently, Pierini et al. [33] used an edge-plane electrode made of pyrolytic graphite to determine Hx, Xa, and UA in four different kinds of fishes, thanks to the anodic stripping voltametric technique. This method is based on a stripping step, where the analyte of interest is oxidized from the electrode, and the resulting current is measured. A detection range of 0.1–50 µM for Hx and Xa and 0.1–25 µM for UA was obtained, alongside an LOD of 0.08, 0.06, and 0.03 µM, respectively. Linear regression equations for the net peak current in comparison with the analyte concentration were calculated, obtaining R2 values of 0.978, 0.992, and 0.990.
In 2018, Torre et al. [34] researched a biosensor based on a carbon electrode, where the enzyme diamine oxidase was immobilized. This simple architecture allowed a low cost and a construction time of only 30 min, obtaining, at the same time, a portable sensor for analysis of small volumes (30–40 µL). The histamine was measured through its electrochemical oxidation, thanks to the use of a redox mediator. The system, tested with spiked tuna and mackerel samples, provided a low LOD (0.97 mgL−1) and a good prediction accuracy, as well as a recovery value of 96–97%. Additionally, the stability of the system was investigated. Acquisitions were performed on stable histamine solutions, over a total of 35 days, obtaining a final maintenance of the original signal of 87.7%. Finally, Yazdanparast et al. [35] developed a sensor, based on a glassy carbon electrode, that allows detection of Xa thanks to a nano-biocomposite made by a multi-walled carbon nanotube and poly(L-aspartic acid) film that immobilizes XOD on the electrode. The system was tested on salmon fish samples, showing a low LOD (3.5 × 10−4 μM) and a linear behavior in two different ranges: 0.001–0.004 µM (R2 = 0.997) and 0.005–50.0 µM (R2 = 0.995). A recovery test was performed on fishes stored for 0, 2, and 8 days, obtaining mean recovery values that were always higher than 95%.
Instead of carbon nanostructures, platinum nanoparticles were used by Chen et al. [36] to mimic the catalytic activity of peroxidase in a fluorescence sensor, designed for the detection of HxA content in aquatic products. This method was tested with fish, squid, and shrimp samples, showing a detection range of 8–2500 μM and an LOD of 2.88 μM, much lower than the threshold specified by the national standard. Moreover, it has facile preparation, low cost, and high reusability.
Table 1 summarizes the presented biosensor techniques, focusing on the type of application (measured substance, fish species, place of application) and on the system results (LOD, detection range).

3. Electronic Multi-Sensory Techniques

As described above, sensory evaluation techniques, like QIM, are the most used methods to classify fish according to freshness [4]. However, these techniques do not seem to keep up with the increasing request of food and its consequent need for rapid quality assessments. According to this assumption, techniques able to simulate the human sensorial perceptiveness, such as e-nose and e-tongue, colorimetric sensor array, and e-eye, have seen an increasing consideration both in scientific papers and industrial applications, as shown in Table 2 [37]. All these devices are based on the use of several arrays of sensors, and the obtained data are often processed with statistical analysis.

3.1. Electronic Nose and Tongue

Electronic nose is a technique aimed at mimicking the functions of the human nose, not in the transduction principles, based on receptors, but in the use of arrays of biochemical transducers, followed by data processing. Within the variety of e-noses designed and created in the last two decades, we can observe systems based on electrochemical gas, metal oxide, and conducting polymer sensors coupled with different feature extraction and data processing methods.
A first application of the technique is represented by the prototype “FishNose”, from Haugen et al. [38]. It consists in a solid-state-based gas-sensor array system, set up to monitor the industrial smoked salmon process, thanks to the monitoring of parameters like TVC and lactic acid bacteria (LAB). Correct classification rates ranging from 93% to 95% were evidenced for fresh and aged samples, respectively.
TVC was also measured by a sensor based on four integrated metal oxide micro-sensors, developed for sardine discrimination according to different freshness stages (fresh, medium, and outdated) by using fishes stored for 2, 3, and 4 days, respectively [39]. More recently, Semeano et al. [40] monitored the spoilage of tilapia thanks an optical electronic nose, made with a gas-sensitive hybrid gel material, obtaining changes in the optical signals consistent with the reproduction of microorganisms. An e-nose system named “Mastersense” was developed by Grassi et al. [41], operating with four MOS sensors. Two different classification methods, K-nearest neighbor (K-NN) and partial least squares–discriminant analysis (PLS-DA), were developed to classify the freshness of samples using e-nose information, correctly classifying fish (plaice and salmon) samples into three freshness classes defined by TVC (unspoiled, acceptable, spoiled). Even though some samples belonging to the intermediate freshness level were misclassified, none of the samples with a risky microbial concentration were classified as being acceptable for consumption, revealing that the model can be safely used for real applications. Total volatile basic nitrogen (TVB-N) and aerobic bacterial counts were instead measured by Tian et al. [42] to study the effect of different storage temperatures (5, 10, and 15 °C) and storage times (3, 4, and 5 days) in hairtail fish, using a system based on metal oxide sensors. The collected data were used as input for a PCA analysis, for the compensation of humidity and temperature effects and the creation of calibration models. R2 values from 0.91 to 0.97 were observed for the two parameters. In the work by Liu et al. [43], the use of a self-designed e-nose system, known as “UTS NOS.E”, was united with a powerful statistical tool, the hidden Markov model (HMM), to establish freshness evaluation models for salmon fillets. Three different uses of HMM were discussed, all obtaining a sensitivity and specificity higher than 95%.
Electronic tongue refers to a device made of sensors that, thanks to the transduction of a signal or a pattern of them, permits identification of tastes in (soluble) food, obtaining a rapid assessment of complex liquids, whereas the e-nose described above works with gaseous systems. In the literature, it is possible to find different electrochemical sensors used for the creation of these device. The most common are amperometric, potentiometric, and voltametric sensor arrays [37]. E-tongues have seen lots of use in the evaluation of fish freshness, with different applications and results based on the characteristic of the sensors. Gil et al. [44] developed a device based on the use of a series of electrodes of different types (metal, metal oxide, and insoluble metal salt), for the evaluation of sea bream freshness, stored for a total of 14 days at 4 °C. An artificial neural network was used for the classification of samples into three temporal classes (first day, days 2–6, rest of days), obtaining a 90% correct classification. Barat et al. [45] published a paper regarding the same field of application, using an e-tongue composed of gold and silver wires. A high correlation was obtained between these measurements and ones made with reference methods, especially with K-value (R2 = 0.96), defined as the ratio between the sum of inosine and hypoxanthine to the sum of all other ATP breakdown products. On the other hand, Ruiz-Rico et al. [46] applied a voltametric e-tongue to cod samples, showing that the device could discriminate between fresh (days 0 and 1) and spoiled (from days 4 or more) fish samples, monitoring parameters like K-value and TVB-N (with an R2 value of 0.73 and 0.80, respectively). More recently, Miao et al. [47] applied a combination of the electronic nose and tongue for a post-cooking sensory evaluation of canned tuna. A PCA algorithm was used for the creation of a K-value calibration model, obtaining a satisfactory distribution of the samples by the first two principal components. Pattarapon et al. [48] used e-tongue, in conjunction with e-nose and several chemical parameters, to study the differences in grass carp quality between vacuum and non-vacuum storage. Results showed that with this device could differentiate between the three different storage conditions (vacuum 30 kPa, vacuum 50 kPa, and non-vacuum), supported by PCA and a linear discriminant analysis (LDA) analysis.

3.2. Colorimetric Sensor Array and Colorimetric Systems

The devices based on colorimetric sensor array technology monitor the process of chemical bonds creations (mainly metal and hydrogen bond, or π-π interaction) between different chemical agents [5]. The creation of these bonds affects the substances, shifting the absorption peak in the visible range, allowing an observation and quantification of the sample changes with the naked eye. An array of different dyes is commonly used to monitor several chemical substances at the same time. Image acquisition devices often help in quantifying the results, extracting the raw images, and processing them further [49]. Zaragoza et al. [50] created a chromogenic array for shelf-life assessment of fresh sea bream in cold storage, using a total of eight different sensitive materials. These data were then used as input for the creation of a PLSR model, with other data obtained from microbial and physico-chemical analyses. Recently, Morsy et al. [51] set up a device based on the responses of 16 dyes (like bromophenol blue and methyl red) to typical spoilage compounds like TVB-N, TMA, cadaverine, and putrescine, to monitor the spoilage process of Atlantic salmon. Dominguez-Aragon et al. [52] worked on a colorimetric method for the monitoring of tilapia fillets. This was accomplished thanks to the detection of color changes in copolymer substances, correlated with microbial growth and TVB-N. In the last couple of years, lots of papers regarding colorimetric sensing were published. Additionally, Zeng et al. [53] monitored TVB-N values, with a colorimetric indicator film based on mulberry anthocyanin extracts incorporated in a matrix. Tests on mud carp samples showed a correlation between the spoilage process and the color changes of the film, caused by the creation of volatile nitrogenous from the fish deterioration. Finally, Liu et al. [54] developed a colorimetric device based on filter paper, coated with a layer of sol-gel matrix entrapping a bromocresol green indicator, that monitors TVB-N levels. The matrix improved the moisture resistance of the system and allowed an accurate response to the fish freshness state. On the other hand, Valdez et al. [55] used an innovative technique, called “forcespinning”, to create nanofibers that have a strong electrostatic interaction with amine ions in the molecules of biogenic amines. The novel technique was tested with different types of meat (including fish), obtaining a detection limit of 7 ppm and a sensitivity of 40 counts/ppm for two biogenic ammines. Huang et al. [56] created a device for the monitoring of volatile compounds, based on agar incorporated with natural dye, testing it with Wuchang bream samples. The main results evidenced a great potential in terms of a “real-time” intelligent package system for convenient, non-destructive, and visual monitoring of fish spoilage.
Colorimetric systems differ from colorimetric sensor arrays in the subject of the investigation; instead of color changes strictly related to the creation of chemical bonds, they can analyze the samples without the need to induce chemical reactions. In fact, these devices are used to monitor changes in the whole sample, considering several visual and color parameters. For example, Quevedo et al. [57] set up a model based on lightness, redness, and yellowness values to assess the color of a salmon fillet. A high correlation (r = 0.95) with sensory panel methods was obtained. In another study, Dowlati et al. [58] monitored the ice storage of farmed and wild gilthead sea bream, investigating several color parameters, including lightness, redness, yellowness, total color change, and chroma. A high correlation (r > 0.95) was found between the parameters of the two fish species and storage days, thanks to the use of multiple regression models and ANN approaches. Balaban et al. [59] developed an image analysis method to follow the lightness value of snapper eyes stored on ice for seven days, focusing on the effects of polarized and non-polarized illumination, wet and dry surface, and contact or non-contact with ice. Similar studies were conducted on the gills of Indian rohu [60], pupil and gill of tilapia [61], and eye chromatic of European hake [62]. Finally, Taheri-Garavand et al. [63] proposed a system based on the use different statistical algorithms to analyze changes in the color parameters of common carp during storage in ice. Results showed that the ANN classifier had the best performance for fish freshness classification (93.01% accuracy). The presented electronic devices are shown in Table 2, which reports the type of application (measured parameters, fish species, place of application) and the statistical analysis algorithm and results.
Table 2. Electronic sensors.
Table 2. Electronic sensors.
SystemMeasured ParametersSpeciesPlace of ApplicationStatistical AnalysisR2/
Classification Rate (%)
Reference
Gas sensor array (FishNose)TVC, Off Odor Rancid, LABAtlantic salmonBoth confined and open airPLSR94%[38]
Integrated metal oxide micro-sensorsTVCSardineConfined air (sampling vessel)SVM/PLSR0.91, 100%[39]
Optical electronic noseBacterial growthTilapiaConfined air----------[40]
MOS sensors (Mastersense)TVCPlaice, salmonConfined airKNN92%[41]
Metal oxide sensorsTVBN,
bacterial counts
Hairtail fishConfined airPCA0.91
0.97
[42]
Metal oxide sensors
(UTS NOS.E)
Freshness stateSalmonConfined airHidden Markov model96%[43]
Potentiometric electrodespH, TVBN, Microbial analysisSea breamContact with filet samplesMPL, PLSR0.96[44]
Au/Ag wiresK-valueSea breamContact with sample solutionLeast Square Method0.96[45]
Voltammetric sensorsK-value,
TVB-N
CodContact with filet samplesPLSR0.79
0.73
[46]
Commercial
e-tongue (ASTREE)
K-valueCanned tunaContact with sample filtratePCA----[47]
Commercial
e-tongue (SA402B)
8 basic sense of tasteGrass carpContact with sample solution--------[48]
Alluminium and silica-based materialsMicrobial countsSea breamNear to the sample
(open air)
PLSR0.92[50]
Chemo-sensitive compoundsTVB-N,
TBA,
pH
Atlantic salmonNear to the sample
(confined air)
Linear fit0.73
0.89
0.91
[51]
Copolymer substancesTVB-N,
Microbial growth
TilapiaNear to the sample
(confined air)
--------[52]
Anthocyanin extractsTVB-NMud CarpNear to the sample
(confined air)
--------[53]
Filter paper coated with a sol-gel matrixTVB-NRed drumFish packageLinear fit0.97[54]
Polydiacetylene nanofibers (ForceSpun)Biogenic amminesNot specifiedNear to the sampleLinear fit0.97[55]
Agar with natural dyesVolatile compoundsWuchang sea breamNear to the samplePCA87.5%[56]
Computer vision systemLightness,
Yellowness,
Redness
Salmon --------[57]
Canon EOS digital cameraGill and eye color changesGilthead sea bream ANN>96%[58]
Nikon D300 digital cameraEye lightnessSnapper Excel correlation function----[59]
Nikon D90 digital cameraGill color changesIndian rohu Statistical mean and STD calculation----[60]
Computer vision systemGill and pupil color changesTilapia Linear fit>0.98[61]
Nikon D7000 digital cameraEye chromaticEuropean hake PCAr > 0.82[62]
Computer vision systemTexture featuresCommon carp SVM
K-NN
ANN
91.5%
90.5%
93.0%
[63]

4. Dielectric Techniques in the Radio Frequency Range

The study of changes in the dielectric properties can be considered a fast and non-invasive way to monitor different parameters of fishes. This method is based on the evaluation of the impedance Z from the Ohm’s law V = ZI, thanks to the use of two electrodes that apply a current flow I and a voltage V through the fish sample [64].
When an electric current is applied to the fish sample it can pass through two different types of pathways: one is a continuous extracellular fluid (ECF), considered to be purely resistive, whereas the second is a series of ECF and intracellular field (ICF) that includes the capacitive effect of the cell membrane, creating a complex impedance with a magnitude frequency dependence [64]. This impedance could be evaluated both as a mean value or as function of the frequency, as a spectrum.
Other than resistivity and conductivity, dielectric properties can be assessed by measuring the electrical permittivity, composed of two factors, the dielectric constant and the loss tangent. These two parameters are influenced by different food attributes, such as the moisture content [65], chemical composition [66], physical structure [67], water activity [68], and density [69]. Additionally, the frequency of the electromagnetic wave influences the results: if the temperature does not change, an increase in frequency causes a decrease in penetration depth [70].
The most investigated techniques are the open-ended coaxial probe, the transmission line, and the resonant cavity method. The first one consists in a coaxial line put in contact with the fish sample, measuring the reflection coefficient, related to the sample permittivity. The transmission line method is based on the use of an enclosed transmission line, filled with a solution of minced sample. Finally, for the resonant cavity method, a piece of sample, of a known geometry, is placed in a single-mode cavity, and the dielectric properties are computed from the changes in the reflected power and the frequency of resonance of the cavity [71].
An open-ended coaxial probe was used by Kent et al. [72] to assess several variables related to freshness on four different fish species: chilled and frozen Baltic cod (Gadus morhua), frozen Atlantic and Pacific hake (Merluccius capensis and Merluccius australis), and chilled farmed Atlantic salmon (Salmo salar). The measurement data were used as input for a PCA analysis, alongside other measured variables like the time of storage and temperature. Results showed that the age of whole gutted cod could be predicted with an error of 1.5 days, as well as the salmon one. The inclusion of measurements obtained with an electronic ‘nose’ sensor, as input for the PCA model, increased the precision up to ±1 day. Regarding hake, discrimination linear models were created for several variables, obtaining an R2 of 0.982 in validation, for the determination of an overall quality grade. Finally, discrimination models between different types and treatments of frozen fish (for hike and cod) were created, obtaining R2 values that were always higher than 0.83 in validation.
Wang et al. [73] focused on the effects of changes in temperature on the dielectric properties, monitoring five different frequencies (27, 40, 433, 915, 1800 MHz) in the temperature range of 20 °C–120 °C with an impedance analyzer based on a transmission line technique. The main results evidenced that, in the function of the temperature, the dielectric loss factor increased for each of the studied frequencies, whereas the dielectric constant had a dual behavior, increasing for 27 (from 97.8 at 20 °C to 149.6 at 120 °C) and 40 MHz but decreasing for 433 MHz (from 60.4 at 20 °C to 56.7 at 120 °C) and for higher frequencies. This reduction at microwave frequency was probably caused by the increase of the intermolecular vibrations that interrupted the water molecule arrangement. Additionally, the penetration depth was studied, observing a decrease of about five times between the HF-VHF (27 and 40 MHz) and the microwave range (915 and 1800 MHz). Finally, regression equations were calculated both for the dielectric constant and loss factor, for different temperatures and fillets parts, obtaining R2 values that were always higher than 0.977.
In 2008, Vaz-Pires et al. [74] characterized whole samples of cuttlefish (Sepia officinalis) and shortfin squid (Illex coindetii) stored in ice, with several analyses, including dielectric measurements carried out by two different fish freshness meters (Torrymeter type 295 by Distell Industries and RT-Freshmeter type RT-2E by Rafagnatækni Electronics). These devices are based on the presence of two pairs of concentrically arranged electrodes in a sensing head, applied directly onto the skin of the fishes. An alternating current is passed through the sample by the outer pairs of electrodes, whereas the inner pair senses the resulting voltage, acquiring in this manner measurements based on the skin impedance. Results showed that these instruments could be useful for the study of fish freshness, especially in the first days. Moreover, for both species, the less rigid areas were identified as the best sides for the acquisition: the ventral side for cuttlefish and the dorsal side for squid.
More recently, both studies conducted by Badiani et al. [75] and Rutkaiova et al. [76] using a fish freshness meter (Torrymeter type 295 by Distell Industries) studied changes in dielectric properties related to the icing of fishes. In particular, in the first article, these measurements were used for the prediction of the storage time and the setting up of discrimination tools between different icing treatments on cuttlefish. In contrast with the previous paper, dielectric properties did not show remarkable changes related to these two parameters, proving to be of little use for the detection of both fish freshness and the icing treatment used. In the second article, the fish freshness meter was used on samples of common carp (Cyprinus carpio L.) to develop a technique proving the falsification of thawed meat as fresh. The obtained results showed a correct classification of 100%, proving the utility of dielectric property measurement for this application. Table 3 shows a selection of the works dedicated to dielectric assessment, focusing on the type of application (studied parameters, fish species, and place of application).

5. Nuclear Magnetic Resonance Spectroscopy

Nuclear magnetic resonance (NMR) spectroscopy is based on the spin of atoms with an odd number of neutrons or proton, like hydrogen. Samples are placed in a magnetic field, where they are subjected to radio waves that excite the nuclei into resonance, detected with sensitive radio receivers.
This generated magnetic field changes the resonance frequency, thus giving access to details of the electronic structure of a molecule and its individual functional groups. As the fields are highly characteristic to individual compounds, NMR spectroscopy is particularly useful for the identification of monomolecular organic compounds. Usually, samples are dissolved in a solvent, because NMR analysis of solids requires dedicated components and may not give equally well-resolved spectra. Concerning fish applications, the most diffused NMR techniques are the low-field NMR (LF-NMR) and the high-resolution NMR (HR-NMR). The last technique appeared to be able in the discrimination between different species, geographical origin, production, and process history [37].
Ciampa et al. [77] studied the changes occurring on amino acids, main organic acids, and alcohols during Bogue fish storage for 15 days at 4 °C and on ice, focusing on the detection of hydrogen (1H-NMR). Results showed a slow increase of acidic amino acids and decrease of basic amino acids in the first days, due to protein autolysis, and a faster process afterward, due to microbial development. Moreover, it was observed that different storing temperatures cause differences in the amino acid trends starting at day 4. The storing process at different temperatures was also studied by Shulimina et al. [78,79] on salmon samples in two different studies, one focusing on temperatures of 0 and 4 °C and the other on 4 and 10 °C. In the first one, the HR-NMR technique allowed simultaneous measurement of the concentration of 31 different metabolites, including all the metabolites necessary for the evaluation of the K-index, obtaining results coherent with literature data. In the second one, NMR measurements were executed on an extract of salmon heads, backbones, and viscera, monitoring a total of 35 metabolites. A PCA analysis allowed the main chemical processes occurring during storage the maximum period of time for safe storage to be determined: seven days at 4 °C and three days at 10 °C. An evolution of the HR-NMR technique, called high-resolution magic angle spinning (HR-MAS), was tested by Heude et al. [80] to rapidly determine the K-value and TMA content from four different species (sea bream, sea bass, trout, and red mullet). There are three main advantages of this technique: it can be performed on unprocessed samples, it requires a quantity of fish (10–15 mg) compatible with industrial analysis, and it is characterized by a fast preparation of the samples, with the total analysis time in the order of 40 min. In the same year Jin et al. [81] assessed a different evolution of HR-NMR, the UltraFast intermolecular Single Quantum Coherence (UF iSQC), to analyze salmon muscle tissues, intact eggs from shishamo smelt, and a whole zebra fish. The main advantage of this technique is surely the speed of acquisition, allowing an analysis of the unprocessed sample in only 5 min. Additionally, Tan et al. [82] evaluated the freshness of intact zebra fish, using a high-resolution 2-D 1H J-resolved NMR technique that permitted the identification of 21 metabolites, and obtained their concentration variations during the spoilage process. With these data, pattern recognition models like PLS-DA and orthogonal partial least square discriminant analysis (OPLS-DA) were used to differentiate between fresh and decayed samples, for a total of five decay stages of spoilage (covering the range of 0–7 days). Regarding LF-NMR, Carneiro et al. [83] investigated the water mobility in the muscle of salted sardines on different days of storage. A significant correlation (p < 0.05) was found between the quality grade obtained by the chemical and physical parameters (cooking test, presence of ammonia and hydrogen sulfide) and the relaxation data obtained with NMR. Table 4 summarizes the recent works published on this technique.

6. Optical Spectroscopic Techniques

With the term “optical”, we refer to a family of techniques that use electromagnetic waves in the ranges of ultraviolet (UV), visible (VIS), and infrared (IR), to obtain information regarding the food freshness and quality. Over the years, it became an interesting and attractive research area thanks to the decrease of instrument prices, the improvement of equipment, and the combination with chemometric tools.
Regarding fish freshness, the main applications concern the detection of microbial growth and spoilage, the prediction of physicochemical and texture features, and the detection of issues due to different species and production methods. The main techniques taken into consideration are fluorescence spectroscopy, infrared spectroscopy, hyperspectral imaging, spectroscopy, and Raman spectroscopy. Table 5 summarizes a selection of the recent works published on this topic.

6.1. Fluorescence Spectroscopy

The physical effect of fluorescence is related to the presence in the food samples of substances called “fluorophores”. They absorb energy from the external ambient, in the form of electromagnetic waves (usually from 180 to 800 nm); then, they emit this energy in the form of light, at a higher frequency [37]. Acquisitions are performed thanks to optical probes or dedicated spectrofluorometers. The fluorescence effect could be exploited with lots of different techniques that are mainly differentiated in the use of one single wavelength or a whole spectrum in the excitation of the fluorophores. Nowadays, one of the most interesting ones is synchronous fluorescence spectroscopy (SFS), where both exciting and emission wavelengths change at the same time, maintaining a positive difference. It allows information from several fluorophores to be obtained at the same time, considering the excitation emission matrix (EEM), which gives information on the whole three-dimensional fluorescence landscape [84]. Another well-known technique is front face fluorescence spectroscopy (FFFS); it solves problems due to a decrease in the fluorescence intensity and a distortion of the emission spectra, observed at a high absorbance rate [85].
The SFS technique was used by Liu et al. [86] to measure pyrene concentrations in the gills of carp fish. The technique was tested in the range of 1–1000 µgL−1, where it showed a linear behavior, and was compared to a more standard gas chromatography technique, obtaining a ratio of 1.003 between the measurements of the two techniques. In the same year, a classification of shrimp samples, according to their geographical origins and species, was performed by Eaton et al. [87] thanks to an EEM spectroscopy and SIMCA classification tool (3 incorrectly classified samples for both species and region, on a total of 22 and 24, respectively). In combination with PLSR regression models, EEM spectroscopy was explored by ElMasry et al. [88,89] in two different studies, both regarding the evaluation of horse mackerel samples. The freshness values were determined with a high-performance liquid chromatography (HPLC) and used for the creation of regression models, obtaining an R2 of 0.85 in the first work and up to 0.94 in the second one, where an optic fiber probe was used both for sample excitation and spectra capture, obtaining an EEM in the range of 250 to 800 nm. Fiber probes were also used by Shibata et al. [90] to develop a technique based on fluorescence fingerprint (FF) for the prediction of ATP content in frozen horse mackerel. The best PLSR model was found using only six excitation/emission wavelength pairs, with the major peak at 270/330 nm (R2 value = 0.88; RMSECV = 0.97 μmol/g).
Principal component analysis (PCA) was used in combination with the FFFS technique by Karoui and Hassoun [91] to study the differences between refrigerated, thawed then refrigerated, and refrigerated then thawed sea bass fillets. The best results were obtained with the excitation set at 380 nm, with an overall classification rate of 88.36%. Then, the whole data set was tested with a concatenation technique called common components and specific weights analysis (CCSWA), obtaining an overall classification rate of 94.9%.
More recently, Omwange et al. [92] studied the fluorescence emission of the fisheye of Japanese Dace at 365 nm, using a UV-LED. From these images, the color components were used to create a PLRS model for the prediction of K-value, obtaining an R2 value of 0.92 (RMSECV = 3.5%).

6.2. Infrared Spectroscopy

Spectroscopy in the near infrared and visible region (VIS/NIR) was historically explored in food analysis, due to the great presence of C–H, N–H, and O–H groups that vibrate in the VIS/NIR range of frequencies [93]. Measurements are usually performed thanks to spectrophotometers equipped with optical fibers or integrating spheres put in contact with the samples.
Tito et al. [94] researched FT-NIR spectroscopy in the range of 800–2500 nm to study the growth of microbial loads in Atlantic salmon over 9 days. The samples were investigated thanks to a fiber optic probe, and the mean spectra were used to create a PLSR model, obtaining an R2 = 0.95 (RMSEC = 0.12 log(cfu)/g). More recently, Reis et al. [95] explored the use of FT-NIR for the discrimination between fresh and frozen/thawed tuna samples. Spectra were obtained in the range of 300–2500 nm and used as input for a PLS-DA algorithm, obtaining a prediction ability of 92% for fresh samples and 82% for thawed ones.
In the last couple of years, deep learning techniques have been used more and more in this field: for example, Wu et al. [96] coupled FTIR spectroscopy (in the range of 400–1000 nm) with a stacked denoising autoencoder neural network (SDAE-NN) to predict the cold storage time of salmon, obtaining an R2 of 0.98 in prediction and a root mean square error in prediction (RMSEP) of 0.93 days whereas Agyekum et al. [97] studied the potentiality of a genetic algorithm to quantify volatile TMA concentrations in silver carps, using spectra acquired with an FT-NIR spectrometer and an optical fiber, resulting in an R2p of 0.980 (RMSEP = 5.1 mgN/100 g). A similar paper was published by the same research group in 2020, where FT-NIR was coupled with an ant colony PLS (ACO-PLS) algorithm to evaluate the K-value in silver carps, obtaining an R2p of 0.98 (RMSEP = 3.98). On the other hand, Alamprese et al. [98] explored the use of infrared spectroscopy (800–14,000 nm) in two discrimination problems: identification of different species (red mullet vs. Atlantic mullet, plaice vs. flounder) and discrimination between fresh and frozen thawed fillets of Atlantic mullet. Data were analyzed with two different algorithms, linear discriminant analysis (LDA) and SIMCA, obtaining sensitivity values of up to 83% and 97.2%, respectively. Another paper based on the application of chemometric algorithms coupled with IR (1000–1800 nm) was published by Zhou et al. [99]. Several parameters like pH and K-value were measured on bighead carp samples, and the predictive models were calculated with PLSR algorithms, coupled with a competitive adaptive reweighted sampling (CARS) for the selection of optimal variables. The best results were obtained for pH, with an R2 value of 0.95 and an RMSEP of 0.081, followed by thiobarbituric acid (TBA) (0.95/0.107), TVB-N (0.93/2.1), and K-value (0.81/6.5).
The mid-infrared (MIR) region of the electromagnetic spectrum (2500–25,000 nm) is one of the most informative sections of the whole electromagnetic spectrum. Like near-infrared (NIR), the use of Fourier transforms has significantly improved its capabilities and applications, replacing dispersive spectrometry. Hernandez-Martinez et al. [100] worked on FT-MIR in reflectance mode (2500–12,500 nm) to predict several physicochemical parameters in three different fish species (Atlantic bluefin tuna, crevalle jack, and Atlantic Spanish mackerel) (R2 between 0.92 and 0.98, PLSR models). More recently, Fengou et al. [101] combined FT-MIR (in the range of 2500–25,000 nm) with multispectral imaging (MSI) to monitor the microbial growth in sea bream. Results showed that FT-MIR gave better predictions for flesh samples (R2p = 0.73 and RMSEP = 0.72), highlighting that this technique could be more suitable for whole samples, with respect to fillets. Finally, Saraiva et al. [102] used a technique called attenuate total reflection (FTIR-ATR) to monitor, in the range of 5500–10,500 nm, the spoilage of salmon fillets at chilled temperatures in three different packaging conditions (R2 of 0.8 and 0.9, PLSR models).

6.3. Hyperspectral Imaging

The term hyperspectral imaging (HSI) refers to the blending of two different techniques, computer vision and VIS/NIR spectroscopy. With a hyperspectral camera it is possible to acquire a full spectrum for every pixel of an image, obtaining three-dimensional data called a “hyperspectral cube” [103]. After a pre-processing phase, a mean spectrum is calculated from every cube, and these are used as input for multivariate statistical analysis to resolve regression or classification problems. Finally, the calibration coefficients of the most informative wavelengths (often called “optimal” wavelengths) are used to calculate the parameters of interest for every pixel, creating a chemical map of the sample [104]. HSI techniques have been used for the development of fast and non-invasive analysis of fish freshness and overall quality, with three main application fields: chemical and physical analyses (moisture content, protein, or fat-related substances, textural features), monitoring of food processes (thermal processing, freezing and chilling, dehydration), and food safety evaluation (freshness evaluation, defect detection) [105].
Cheng et al. [106] studied the use of HSI in the range of 400–1000 nm to evaluate the K-value in grass carp and silver carp. PLSR and least square support vector machine (LS-SVM) were used to create regression models, both with full spectra and with only seven optimal wavelengths selected by a successive projection algorithm (SPA). The best results were obtained with the full-wavelength PLSR, with an R2p (in prediction) of 0.94 (RMSEP = 5.21%). In 2016, the same research group expanded the previous work, using LS-SVM and multiple linear regression (MLR) to simultaneously determine the K-value, TVB-N, and thiobarbituric acid reactive substances (TBARSs), with the support of SPA and genetic algorithm (GA) for the determination of the optimal wavelengths [107]. Both algorithms gave excellent results in the determination of K-value and TVB-N, with an R2p > 0.90, with five wavelengths found by SPA and six wavelengths found by GA. In 2017, they combined the GA with an innovative algorithm called physarum network (PN), focusing on the determination of the TVB-N [108]. PLSR and LS-SVM models were created with the six optimal wavelengths found by the PN-GA algorithm. The use of image texture variables, extracted by gray-level gradient co-occurrence matrix (GLGCM), enhanced the model, obtaining an R2p of 0.98 (RMSEP = 1.44 mgN/100 g). In 2016, Ivorra et al. [109] developed a model for shelf-life prediction of salmon in two different steps: first, they used a K-nearest-neighbor model to classify the fish tissue into fat and muscles, and then they created a PLSR model for each group (400–1000 nm). The model created with only fat tissue spectra obtained the best results, with an R2CV (in cross-validation) of 0.89 (RMSECV = 2.7 days). More recently, Khoshnoudi-Nia et al. [110] studied the assessment of TVB-N, psychotropic plate count (PPC), and sensory score in rainbow trout fillets. Four different multivariate analyses were developed: PLSR, MLR, LS-SVM, and back propagation neural network (BP-NN), each of which used six optimal wavelengths determined by GA, coming from the original range of 430–1010 nm. All models showed good performance in the prediction of all three parameters (R2p ≥ 0.856), with the best results coming from LS-SVM (R2p = 0.91).
The HSI technique could be used to measure parameters not related with freshness. For example, Xu et al. [111] worked on the assessment of gross energy density values in salmon fillets. In this work, images were acquired in the range of 900–1700 nm and used for the creation of PLSR and epsilon-SVR models. Altogether, the best results were obtained with a stepwise-PLSR model (R2p = 0.908 and RMSEP = 6.87%), where only four wavelengths (931, 1001, 1135, and 1168 nm) were selected. Another example is provided by the work conducted by Qu et al. [112] to map the moisture content in grass carp fillets subjected to different freeze-drying conditions. The spectra (400–1000 nm) were used as input for a PLSR model, and the application of regression coefficients and weighted values resulted in the selection of nine optimal wavelengths, with a final R2p of 0.91 (RMSEP = 56.3 g/kg). Finally, Qin et al. [113] studied the detection of fillet substitution and mislabeling (fresh/thawed), using reflectance in the VIS/NIR region (419–1007 nm), fluorescence by 365 nm UV excitation (438–718 nm), reflectance in the SWIR region (842–2532 nm), and Raman by 785 nm laser excitation (103–2831 cm−1). Images were acquired on six different fish species (red snapper, vermilion snapper, Malabar snapper, summer flounder, white bass, and tilapia), and used as input for 24 different machine learning techniques. In general, the VIS/NIR reflectance mode gave the best performance for both species and freshness inspection, proving to be the best wavelength range for the detection of fish fillet substitution and mislabeling.

6.4. Raman Spectroscopy

Raman spectroscopy is based on the measurement of the vibrational energy modes thanks to the use of scattered light: A monochromatic laser beam irradiates the sample (UV, VIS or NIR), causing a shift in the vibrational energy level of the molecules from the ground state to a state of high-energy collision. When these molecules quickly return to the ground state, the physical process of Raman scattering occurs, allowing structural and chemical information of the sample to be obtained at the same time [114]. Measurements are performed with dedicated Raman spectroscopy, starting from minced samples put into solution. Sanchez-Alonso et al. [115] showed that the alteration in the spectra related to lipid oxidation was in the Raman stretching wavenumber regions of 1658 cm−1 in frozen hake fillets. Janci et al. [116] evaluated a technique called surface enhanced Raman spectroscopy (SERS) to determine the histamine content in Atlantic mackerel, in the range of 1050–1650 cm−1. The resulting spectra were used as input for a PLSR analysis (R2p of 0.97 and RMSEP of 14.9 mg/kg). Histamine content was also the parameter analyzed by Xie et al. [117] that used SERS on thin-layer chromatography plates containing fish samples, with an innovative use of silver nanoparticles in conjunction with an NaCl aqueous solution, suppressing the masking effect caused by excessive fluorescamine (a reagent used for the detection of amines and peptides). The spectra were acquired in the range of 600–1800 cm−1 and compared with the results of a more traditional, but less cost and user-friendly, HPLC technique, obtaining good agreement and reproducibility. Another application of Raman spectroscopy is represented by the detection of unwanted chemical products in fishes. Deng et al. [118] investigated the use of SERS for the detection of Green Malachite (GM) in fish samples, by means of a self-developed glass fiber paper as substrate for the samples. Spectra were acquired in the range of 300–1700 cm−1, and an R2 of 0.99 calculated in the range of 10−7–10−5 mol/L, with an LOD of 20 ng/mL, was observed.
Regarding classification problems, Velioglu et al. [119] investigated the effects of freezing on fishes with Raman spectroscopy, to discriminate between fresh, once frozen-thawed, and twice frozen-thawed. The analysis was carried out on six different species (horse mackerel, European anchovy, red mullet, bluefish, Atlantic salmon, and flying gurnard), in the range of 200–2000 cm−1. The spectra were analyzed with a PCA that allowed successful discrimination between the different classes. More recently, Song et al. [120] developed a classification model for the detection of fish bones in grass carp fillets, analyzing them with a Raman hyperspectral imaging system in the range of 820–2847 cm−1. An algorithm called the fuzzy-rough set model based on the thermal-charge algorithm (FRSTCA) was applied to the resulting spectra to select the spectral band containing the major amount of information, which was 961–965 cm−1.
From these data, a support vector data description (SVDD) classification model was established, obtaining a detection performance of 90.5%. Table 5 summarizes the presented spectroscopic techniques, focusing on the type of application (measured parameters, fish species) and on the statistical analysis (algorithm, statistical results).
Table 5. Spectroscopic techniques.
Table 5. Spectroscopic techniques.
Spectrocopic TechniqueMeasured ParametersSpeciesStatistical AnalysisBest R2/
Classification Rate (%)
Reference
SFSPyreneCarp----------[86]
EEMGeographical origins
Species
ShrimpSIMCA91.7%[87]
EEMK-valueHorse mackerelPLSR0.89/87.5%[88]
EEMFreshness valueHorse mackerelPLSR0.94[89]
Fluorescence Fingerprint ATP contentHorse mackerelPLSR 0.88[90]
FFFSThawing/Refrigerating processSea bassCCSWA94.9%[91]
UV-LED systemK-valueJapanese DacePLSR0.92[92]
NIR
(800–2500 nm)
Growth of microbial loadAtlantic salmonPLSR0.95[94]
NIR
(300–2500 nm)
Fresh/thawedTunaPLS-DA92%[95]
NIR
(400–1000 nm)
Cold-storage timeSalmonPLSR, BP-NN, SDAE-NN0.98 (SDAE-NN)[96]
NIR/MIR
(800–14,000 nm)
Species
Fresh/thawed
Red mullet, Plaice Atlantic mullet, FlounderLDA, SIMCA97.5%[98]
NIR
(1000–2500 nm)
TMA concentrationSilver carpPLSR, GA-PLS0.98 (GA-PLS)[97]
NIR
(1000–1800 nm)
K-value
TVB-N
TBARS
pH
Bighead carpPLSR0.81
0.93
0.95
0.95
[99]
FT-MIR
(2500–25,000 nm)
Chemicophysical parametersAtlantic bluefin tuna, Crevalle jack, Atlantic Spanish mackerelPLSR >0.92[100]
FT-MIR
(2500–25,000 nm)
Microbial growthSea breamPLSR0.73[101]
FTIR-ATR
(5500–10,500 nm)
TVCSalmonPLSR0.8[102]
HSI
(400–1000 nm)
K-valueGrass and silver carpPLSR, LS-SVM0.94 (PLSR)[106]
HSI
(400–1000 nm)
K-value
TVB-N
TBARS
Grass carpLS-SVM
MLR
0.93 (MLR)
0.87 (LS-SVM)
0.94 (MLR)
[107]
HSI
(400–1000 nm)
TVB-NGrass carpPLSR
LS-SVM
0.98 (PLSR)[108]
HSI
(400–1000 nm)
Shelf-life predictionSalmonPLSR0.89[109]
HSI
(430–1010 nm)
TVB-N
PPC
Sensory score
Rainbow troutPLSR, BP-NN, LS-SVM, MLR0.91 (LS-SVM)[110]
HIS
(900–1700 nm)
Gross energy densitySalmonPLSR, epsilon-PLSR0.91 (both)[111]
HSI
(400–1000 nm)
Moisture contentGrass carpPLSR0.91[112]
HIS
(400–2500 nm)
Species
Fresh/thawed
Red snapper, Vermilion snapper, Malabar snapper, Tilapia white bass, Summer flounder 24 different ML algorithms100% (VNIR)
99% (SWIR)
[113]
FT–Raman
(900–4000 cm−1)
Lipid contentHake-------[115]
SERS
(1050–1650 cm−1)
Histamine contentAtlantic mackerelPLSR0.96[116]
SERS
(600–1800 cm−1)
Histamine contentRibbonfish, Tuna--------[117]
SERS
(300–1700 cm−1)
Green malachiteNot specified--------[118]
Standard Raman
(200–2000 cm−1)
Fresh/thawedHorse mackerel, Flying gurnard red mullet, European anchovy, Atlantic salmon, BluefishPCA----[119]
Raman HIS
(820–2847 cm−1)
Detection of fish spinesGrass carpSVDD90.5%[120]

7. Conclusions and Future Trends

The main families of innovative systems for fish freshness assessment and spoilage monitoring were reviewed. Biosensors, electronic sensors, dielectric devices, and spectroscopy techniques were covered, with a secondary focus on the several algorithms (multivariate statistical analysis, or more complex machine learning and deep learning techniques) used for the set up of classification/regression models and chemical maps. Some of these devices, thanks to a fast and less invasive acquisition process, are much more suitable for in-line or on-line industrial monitoring with respect to traditional methods (sensory, physical, and chemical parameters), which are costly, time consuming, and require high-skill operators. Spectroscopic devices could represent the best method for industrial application, being compact and not requiring contact with the fish. Between these techniques, hyperspectral imaging could be the most interesting for the huge amount of gathered information, although the acquisition speed of hyperspectral cameras must be increased before it can be used in practice. To obtain this important improvement, algorithms for the selection of few optimal wavelengths should be applied, optimizing and speeding up the measurement phase. Finally, biosensor applications in the food package could represent a good freshness monitoring method for products on the market.
However, the main conclusion that can be reached by the review of the literature is that, nowadays, all the described techniques have specific advantages and disadvantages: none of them can perform a satisfactory measurement of the overall fish quality by themselves. For this reason, the mentioned devices have not yet had extensive and widespread use in practical applications. In addition, several of the examined solutions are destructive. So, in the near future, research could be conducted on the combination of different techniques, allowing an increase of the volume of information extracted from the sample and the limitations of each individual method to be overcome. The continuous innovations in computer science and in complex statistical analysis could allow the use of these techniques, especially the spectroscopic ones, in an increasing number of different applications.

Author Contributions

Conceptualization, A.B. and S.D.; methodology, A.B and S.D.; validation, S.D., M.T. and L.R.; investigation, L.F.; writing—original draft preparation, L.F.; writing—review and editing, A.B., S.D., M.T., and L.R.; visualization, L.F.; supervision, A.B., M.T. and L.R.; project administration, M.T. and L.R. All authors have read and agreed to the published version of the manuscript.

Funding

This research received no external funding.

Institutional Review Board Statement

Not applicable.

Informed Consent Statement

Not applicable.

Data Availability Statement

Not applicable.

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. The State of Food and Agricolture 2009; FAO: Rome, Italy, 2009.
  2. Gorga, C.; Rosinvalli, J. Quality Assurance of Seafood; Van Nostrand Reinhold: New York, NY, USA, 1988. [Google Scholar]
  3. Sen, D.P. Advances in Fish Processing Technology; Allied Publisher Private Limited: Mumbai, India, 2005. [Google Scholar]
  4. Alasalvar, C.; Shahidi, F.; Miyashita, K.; Wanasundara, U. Seafood quality, safety, and health applications: An overview. In Handbook of Seafood Quality, Safety and Health Applications; Blackwell Publishing Ltd.: Oxford, UK, 2010; pp. 1–10. [Google Scholar]
  5. Wu, L.; Pu, H.; Sun, D. Novel techniques for evaluating freshness quality attributes of fish: A review of recent developments. Trends Food Sci. Technol. 2019, 83, 259–273. [Google Scholar] [CrossRef]
  6. Parlapani, F.F.; Mallouchos, A.; Haroutounian, S.S.; Boziaris, I.S. Microbiological spoilage and investigation of volatile profile during storage of sea bream fillets under various conditions. Int. J. Food Microbiol. 2014, 189, 153–163. [Google Scholar] [CrossRef]
  7. Hyldig, G.; Green-Petersen, D.M.B. Quality Index Method—An Objective Tool for Determination of Sensory Quality. J. Aquat. Food Prod. Technol. 2008, 13, 71–80. [Google Scholar] [CrossRef]
  8. Saito, T.; Arai, K.; Matsuyoshi, M. A new method for estimating the freshness of fish. Bull. Jpn. Soc. Sci. Fish. 1959, 24, 749–750. [Google Scholar] [CrossRef]
  9. Casas, C.; Martinez, O.; Guillen, M.D.; Pin, C.; Salmeron, J. Textural properties of raw Atlantic salmon (Salmo salar) at three points along the fillet, determined by different methods. Food Control 2006, 17, 511–515. [Google Scholar] [CrossRef]
  10. Yao, L.; Luo, Y.; Sun, Y.; Shen, H. Establishment of kinetic models based on electrical conductivity and freshness indictors for the forecasting of crucian carp (Carassius carassius) freshness. J. Food Eng. 2011, 107, 147–151. [Google Scholar] [CrossRef]
  11. Olafsdottir, G.; Nesvadba, P.; Di Natale, C.; Careche, M.; Oehlenschläger, J.; Tryggvadóttir, S.V.; Schubring, S.; Kroeger, M.; Heia, K.; Esaiassen, M.; et al. Multisensor for fish quality determination. Trends Food Sci. Technol. 2004, 15, 86–93. [Google Scholar]
  12. Caggiano, M. Quality in harvesting and post-harvesting procedures–influence on quality. Fish freshness and quality assessment for sea bass and sea bream. Cah. Options. Méditerr. 2000, 51, 55–61. [Google Scholar]
  13. Cheng, J.; Sun, D.; Han, Z.; Zeng, X. Texture and Structure Measurements and Analyses for Evaluation of Fish and Fillet Freshness Quality: A Review. Compr. Ren. Food Sci. F 2014, 13, 52–61. [Google Scholar] [CrossRef]
  14. Lavine, B.K.; Mirjankar, N. Clustering and Classification of Analytical Data, update based on the original article by Lavine, B.K. In Encyclopedia of Analytical Chemistry; Meyers, R.A., Meyers, R.A., Eds.; John Wiley & Sons Ltd.: Hoboken, NJ, USA, 2000. [Google Scholar]
  15. Wold, S.; Sjöström, M.; Eriksson, L. PLS-regression: A basic tool of chemometrics. Chemom. Intell. Lab. Syst. 2001, 58, 109–130. [Google Scholar] [CrossRef]
  16. Nayak, J.; Vakula, K.; Dinesh, P.; Naik, B.; Pelusi, D. Intelligent food processing: Journey from artificial neural network to deep learning. Comput. Sci. Rev. 2020, 38. [Google Scholar] [CrossRef]
  17. Bhalla, N.; Jolly, P.; Formisano, N.; Estrela, P. Introduction to biosensors. Essays Biochem. 2016, 30, 1–8. [Google Scholar]
  18. Lawal, A.T.; Adeloju, S.B. Progress and recent advances in fabrication and utilization of hypoxanthine biosensors for meat and fish quality assessment: A review. Talanta 2012, 100, 217–228. [Google Scholar] [CrossRef] [PubMed]
  19. Thakur, M.S.; Ragavan, K.V. Biosensors in food processing. J. Food Sci. Technol. 2013, 50, 625–641. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  20. Parkhey, P.; Mohan, S.V. Biosensing Applications of Microbial Fuel Cell: Approach Toward Miniaturization. In Microbial Electrochemical Technology; Mohan, S.V., Varjani, S., Pandey, A., Eds.; Elsevier: Amsterdam, The Netherlands, 2019. [Google Scholar]
  21. Tang, X.; Liu, Y.; Hou, H.; You, T. A nonenzymatic sensor for xanthine based on electrospun carbon nanofibers modified electrode. Talanta 2011, 83, 1410–1414. [Google Scholar] [CrossRef] [PubMed]
  22. Apetrei, I.M.; Apetrei, C. Amperometric Biosensor Based on Diamine Oxidase/Platinum Nanoparticles/Graphene/Chitosan Modified Screen-Printed Carbon Electrode for Histamine Detection. Sensors 2016, 16, 422. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  23. Alarcon-Angeles, G.; Álvarez-Romero, G.A.; Merkoçi, A. Electrochemical biosensors: Enzyme kinetics and role of nanomaterials. In Encyclopedia of Interfacial Chemistry: Surface Science and Electrochemistry; Elsevier: Amsterdam, The Netherlands, 2018; pp. 140–155. [Google Scholar]
  24. Heising, J.K.; Dekker, M.; Bartels, P.V.; van Boekel, M.J.A.S. A non-destructive ammonium detection method as indicator for freshness for packed fish: Application on cod. J. Food Process Eng. 2012, 110, 254–261. [Google Scholar] [CrossRef]
  25. Heising, J.K.; Bartels, P.V.; van Boekel, M.J.A.S.; Dekker, M. Non-destructive sensing of the freshness of packed cod fish using conductivity and pH electrodes. J. Food Process Eng. 2014, 124, 80–85. [Google Scholar] [CrossRef]
  26. Chang, L.; Chuang, M.; Zan, H.; Meng, H.; Lu, C.; Yeh, P.; Chen, J. One-Minute Fish Freshness Evaluation by Testing the Volatile Amine Gas with an Ultrasensitive Porous-Electrode-Capped Organic Gas Sensor System. ACS Sens. 2017, 2, 531–539. [Google Scholar] [CrossRef]
  27. Vishnu, N.; Gandhi, M.; Rajagopalb, D.; Kumar, A.S. Pencil graphite as an elegant electrochemical sensor for separation-free and simultaneous sensing of hypoxanthine, xanthine and uric acid in fish samples. Anal. Methods 2017, 9, 2265–2274. [Google Scholar] [CrossRef]
  28. Lee, M.; Wu, C.; Sari, M.I.; Hsieh, Y. A disposable non-enzymatic histamine sensor based on the nafion-coated copper phosphate electrodes for estimation of fish freshness. Electrochim. Acta 2018, 283, 772–779. [Google Scholar] [CrossRef]
  29. Li, C.; Hao, J.; Wu, K. Triethylamine-controlled Cu-BTC frameworks for electrochemical sensing fish freshness. Anal. Chim. Acta 2019, 1085, 68–74. [Google Scholar] [CrossRef]
  30. Thandavan, K.; Gandhi, S.; Sethuraman, S.; Rayappan, J.B.B.; Krishnan, U.M. Development of electrochemical biosensor with nano-interface for xanthine sensing—A novel approach for fish freshness estimation. Food Chem. 2013, 139, 963–969. [Google Scholar] [CrossRef]
  31. Narang, J.; Malhotra, N.; Singhal, C.; Pundir, C.S. Evaluation of Freshness of Fishes Using MWCNT/TiO2 Nanobiocomposites Based Biosensor. Food Anal. Methods 2017, 10, 522–528. [Google Scholar] [CrossRef]
  32. Borisova, B.; Sánchez, A.; Jiménez-Falcao, S.; Martín, M.; Salazar, P.; Parrado, C.; Pingarrón, J.M.; Villalonga, R. Reduced graphene oxide-carboxymethylcellulose layered with platinum nanoparticles/PAMAM dendrimer/magnetic nanoparticles hybrids. Application to the preparation of enzyme electrochemical biosensors. Sens. Actuators B Chem. 2016, 232, 84–90. [Google Scholar] [CrossRef]
  33. Pierini, G.D.; Robledo, S.N.; Zon, M.A.; Di Nezio, M.S.; Granero, A.M.; Fernández, H. Development of an electroanalytical method to control quality in fish samples based on an edge plane pyrolytic graphite electrode. Simultaneous determination of hypoxanthine, xanthine and uric acid. Microchem. J. 2018, 138, 58–64. [Google Scholar] [CrossRef]
  34. Torre, R.; Costa-Rama, E.; Nouws, H.P.A.; Delerue-Matos, C. Diamine oxidase-modified screen-printed electrode for the redox-mediated determination of histamine. J. Anal. Sci. Technol. 2020, 11, 1–8. [Google Scholar] [CrossRef]
  35. Yazdanparast, S.; Benvidi, A.; Abbasi, S.; Rezaeinasab, M. Enzyme-based ultrasensitive electrochemical biosensor using poly(l-aspartic acid)/MWCNT bio-nanocomposite for xanthine detection: A meat freshness marker. Microchem. J. 2019, 149. [Google Scholar] [CrossRef]
  36. Chen, J.; Lu, Y.; Yan, F.; Wu, Y.; Huang, D.; Weng, Z. A fluorescent biosensor based on catalytic activity of platinum nanoparticles for freshness evaluation of aquatic products. Food Chem. 2020, 310, 125922. [Google Scholar] [CrossRef] [PubMed]
  37. Hassoun, A.; Karoui, R. Quality evaluation of fish and other seafood by traditional and nondestructive instrumental methods: Advantages and limitations. Crit. Rev. Food Sci. Nutr. 2017, 57, 1976–1998. [Google Scholar] [CrossRef]
  38. Haugen, J.E.; Chanie, E.; Westad, F.; Jonsdottir, R.; Bazzo, S.; Labreche, S.; Marcq, P.; Lundby, F.; Olafsdottir, G. Rapid control of smoked Atlantic salmon (Salmo salar) quality by electronic nose: Correlation with classical evaluation methods. Sens. Actuators B Chem. 2006, 116, 72–77. [Google Scholar] [CrossRef]
  39. El Barbri, N.; Mirhisse, J.; Ionescu, R.; El Bari, N.; Correig, X.; Bouchikhi, B.; Llobet, E. An electronic nose system based on a micro-machined gas sensor array to assess the freshness of sardines. Sens. Actuators B Chem. 2009, 141, 538–543. [Google Scholar] [CrossRef]
  40. Semeano, A.T.S.; Maffei, D.F.; Palma, S.; Li, R.W.C.; Franco, B.D.G.M.; Roque, A.C.A.; Gruber, J. Tilapia fish microbial spoilage monitored by a single optical gas sensor. Food Control 2018, 89, 72–76. [Google Scholar] [CrossRef]
  41. Grassi, S.; Benedetti, S.; Opizzio, M.; di Nardo, E.; Buratti, S. Meat and Fish Freshness Assessment by a Portable and Simplified Electronic Nose System (Mastersense). Sensors 2019, 19, 3225. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  42. Tian, X.-Y.; Cai, Q.; Zhang, Y.-M. Rapid Classification of Hairtail Fish and Pork Freshness Using an Electronic Nose Based on the PCA Method. Sensors 2012, 12, 260–277. [Google Scholar] [CrossRef] [Green Version]
  43. Liu, T.; Zhang, W.; Yuwono, M.; Zhang, M.; Ueland, M.; Forbes, S.L.; Su, S.W. A data-driven meat freshness monitoring and evaluation method using rapid centroid estimation and hidden Markov models. Sens. Actuators B Chem. 2020, 311, 127868. [Google Scholar] [CrossRef]
  44. Gil, L.; Barat, J.; Escriche, I.; Garcia-Breijo, E.; Martınez-Manez, R.; Soto, J. An electronic tongue for fish freshness analysis using a thick-film array of electrodes. Microchim. Acta 2008, 163, 121–129. [Google Scholar] [CrossRef]
  45. Barat, J.M.; Gil, L.; García-Breijo, E.; Aristoy, M.C.; Toldrá, F.; Martínez-Máñez, R.; Soto, J. Freshness monitoring of sea bream (Sparus aurata) with a potentiometric sensor. Food Chem. 2008, 108, 681–688. [Google Scholar] [CrossRef]
  46. Ruiz-Rico, M.; Fuentes, A.; Masot, R.; Alcañiz, M.; Fernández-Segovia, I.; Barat, J.M. Use of the voltammetric tongue in fresh cod (Gadus morhua) quality assessment. Innov. Food Sci. Emerg. Technol. 2013, 18, 256–263. [Google Scholar] [CrossRef]
  47. Miao, H.; Liu, Q.; Bao, H.; Wang, X.; Miao, S. Effects of different freshness on the quality of cooked tuna steak. Innov. Food Sci. Emerg. Technol. 2017, 44, 67–73. [Google Scholar] [CrossRef] [Green Version]
  48. Pattarapon, P.; Zhang, M.; Bhandari, B.; Gao, Z. Effect of vacuum storage on the freshness of grass carp (Ctenopharyngodon idella) fillet based on normal and electronic sensory measurement. J. Food Process. Preserv. 2018, 42, 13418. [Google Scholar] [CrossRef]
  49. Huang, X.; Xin, J.; Zhao, J. A novel technique for rapid evaluation of fish freshness using colorimetric sensor array. J. Food Eng. 2011, 105, 632–637. [Google Scholar] [CrossRef]
  50. Zaragozá, P.; Fuentes, A.; Fernández-Segovia, I.; Vivancos, J.; Rizo, A.; Ros-Lis, J.V.; Barat, J.M.; Martínez-Máñez, R. Evaluation of sea bream (Sparus aurata) shelf life using an optoelectronic nose. Food Chem. 2013, 138, 1374–1380. [Google Scholar]
  51. Morsy, M.K.; Zór, K.; Kostesha, N.; Alstrøm, T.S.; Heiskanen, A.; El-Tanahi, H.; Sharoba, A.; Papkovsky, D.; Larsen, J.; Khalaf, H.; et al. Development and validation of a colorimetric sensor array for fish spoilage monitoring. Food Control 2016, 60, 346–352. [Google Scholar] [CrossRef]
  52. Domínguez-Aragón, A.; Olmedo-Martínez, J.A.; Zaragoza-Contreras, E.A. Colorimetric sensor based on a poly(ortho-phenylenediamine-co-aniline) copolymer for the monitoring of tilapia (Orechromis niloticus) freshness. Sens. Actuators B Chem. 2018, 259, 170–176. [Google Scholar] [CrossRef]
  53. Zeng, P.; Chen, X.; Qin, Y.; Zhang, Y.; Wang, X.; Wang, J.; Ning, Z.; Ruan, Q.; Zhang, Y. Preparation and characterization of a novel colorimetric indicator film based on gelatin/polyvinyl alcohol incorporating mulberry anthocyanin extracts for monitoring fish freshness. Int. Food Res. J. 2019, 126, 108604. [Google Scholar] [CrossRef]
  54. Liu, X.; Chen, K.; Wang, J.; Wang, Y.; Tang, Y.; Gao, X.; Zhu, L.; Li, X.; Li, J. An on-package colorimetric sensing label based on a sol-gel matrix for fish freshness monitoring. Food Chem. 2020, 307, 125580. [Google Scholar] [CrossRef] [PubMed]
  55. Valdez, M.; Gupta, S.K.; Lozano, K.; Mao, Y. ForceSpun polydiacetylene nanofibers as colorimetric sensor for food spoilage detection. Sens. Actuators B Chem. 2019, 297, 126734. [Google Scholar] [CrossRef]
  56. Huang, S.; Xiong, Y.; Zou, Y.; Dong, Q.; Ding, F.; Liu, X.; Li, H. A novel colorimetric indicator based on agar incorporated with Arnebia euchroma root extracts for monitoring fish freshness. Food Hydrocoll. 2019, 90, 198–205. [Google Scholar] [CrossRef]
  57. Quevedo, R.; Aguilera, J.; Pedreschi, F. Color of Salmon Fillets by Computer Vision and Sensory Panel. Food Bioprocess Tech. 2010, 3, 637–643. [Google Scholar] [CrossRef]
  58. Dowlati, M.; Mohtasebi, S.S.; Omid, M.; Razavi, S.H.; Jamzad, M.; de la Guardia, M. Freshness assessment of gilthead sea bream (Sparus aurata) by machine vision based on gill and eye color changes. J. Food Eng. 2013, 119, 277–287. [Google Scholar] [CrossRef]
  59. Balaban, M.Ö.; Alçiçek, Z. Use of polarized light in image analysis: Application to the analysis of fish eye color during storage. LWT Food Sci. Technol. 2015, 60, 365–371. [Google Scholar] [CrossRef]
  60. Issac, A.; Dutta, M.K.; Sarkar, B. Computer vision based method for quality and freshness check for fish from segmented gills. Comput. Electron. Agric. 2017, 139, 10–21. [Google Scholar] [CrossRef]
  61. Shi, C.; Qian, J.; Han, S.; Fan, B.; Yang, X.; Wu, X. Developing a machine vision system for simultaneous prediction of freshness indicators based on tilapia (Oreochromis niloticus) pupil and gill color during storage at 4 °C. Food Chem. 2018, 243, 134–140. [Google Scholar] [CrossRef]
  62. Rocculi, P.; Cevoli, C.; Tappi, S.; Genovese, J.; Urbinati, E.; Picone, G.; Fabbri, A.; Capozzi, F.; Dalla Rosa, M. Freshness assessment of European hake (Merluccius merluccius) through the evaluation of eye chromatic and morphological characteristics. Int. Food Res. J. 2019, 115, 234–240. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  63. Taheri-Garavand, A.; Fatahi, S.; Banan, A.; Makino, Y. Real-time nondestructive monitoring of Common Carp Fish freshness using robust vision-based intelligent modeling approaches. Comput. Electron. Agric. 2019, 159, 16–27. [Google Scholar] [CrossRef]
  64. Damez, J.; Clerjon, S.; Abouelkaram, S.; Lepetit, J. Dielectric behavior of beef meat in the 1–1500 kHz range: Simulation with the Fricke/Cole–Cole model. Meat Sci. 2007, 77, 512–519. [Google Scholar] [CrossRef] [PubMed]
  65. Cataldo, A.; Piuzzi, E.; Cannazza, G.; De Benedetto, E. Dielectric spectroscopy of liquids through a combined approach: Evaluation of the metrological performance and feasibility study on vegetable oils. IEEE Sens. J. 2009, 9, 1226–1233. [Google Scholar] [CrossRef]
  66. Ragni, L.; Berardinelli, A.; Cevoli, C.; Filippi, M.; Iaccheri, E.; Romani, A. Assessment of food compositional parameters by means of a Waveguide Vector Spectrometer. J. Food Eng. 2017, 205, 25–33. [Google Scholar] [CrossRef]
  67. Ragni, L.; Berardinelli, A.; Cevoli, C.; Iaccheri, E.; Valli, E.; Zuffi, E.; Lazzarini, R.; Toschi, T.G. Multi-analytical approach for monitoring the freezing process of a milkshake based product. J. Food Eng. 2016, 168, 20–26. [Google Scholar] [CrossRef]
  68. Iaccheri, E.; Laghi, L.; Cevoli, C.; Berardinelli, A.; Ragni, L.; Romani, S.; Rocculi, O. Different analytical approaches for the study of water features in green and roasted coffee beans. J. Food Eng. 2015, 146, 28–35. [Google Scholar] [CrossRef]
  69. Kim, Y.R.; Morgan, M.T.; Okos, M.R.; Stroshine, R.L. Measurement and prediction of dielectric properties of biscuit dough at 27 MHz. J. Microw. Power Electromagn. Energy 1998, 33, 184–194. [Google Scholar] [CrossRef]
  70. Ryynänen, S. The electromagnetic properties of food materials: A review of the basic principles. J. Food Eng. 2005, 26, 409–429. [Google Scholar]
  71. Sosa-Morales, M.E.; Valerio-Junco, L.; López-Malo, A.; García, H.S. Dielectric properties of foods: Reported data in the 21st Century and their potential applications. LWT Food Sci. Technol. 2010, 43, 1169–1179. [Google Scholar] [CrossRef]
  72. Kent, M.; Knöchel, R.; Daschner, F.; Schimmer, O.; Oehlenschläger, J.; Mierke-Klemeyer, S.; Barr, U.K.; Floberg, P.; Tejada, M.; Huidobro, A.; et al. Time domain reflectometry as a tool for the estimation of quality in foods. Int. Agrophys. 2004, 18, 225–229. [Google Scholar]
  73. Wang, Y.; Tang, J.; Rasco, B.; Kong, F.; Wang, S. Dielectric properties of salmon fillets as a function of temperature and composition. J. Food Eng. 2008, 87, 236–246. [Google Scholar] [CrossRef]
  74. Vaz-Pires, P.; Seixas, P.; Mota, M.; Lapa-Guimarães, J.; Pickova, J.; Lindo, A.; Silva, T. Sensory, microbiological, physical and chemical properties of cuttlefish (Sepia officinalis) and broadtail shortfin squid (Illex coindetii) stored in ice. LWT Food Sci. Technol. 2008, 41, 1655–1664. [Google Scholar] [CrossRef] [Green Version]
  75. Badiani, A.; Bonaldo, A.; Testi, S.; Rotolo, M.; Serratore, P.; Giulini, G.; Pagliuca, G.; Gatta, P. Good handling practices of the catch: The effect of early icing on the freshness quality of cuttlefish (Sepia officinalis L.). Food Control 2013, 32, 327–333. [Google Scholar] [CrossRef]
  76. Rutkayová, J.; Voříšková, J.; Beneš, K.; Kašparů, M.; Škrleta, J.; Klečacký, D. The Dielectric Properties Detection of Frozen-thawed Fish Meat by Using Freshness Meter. Chem. Listy 2019, 113, 515–517. [Google Scholar]
  77. Ciampa, A.; Picone, G.; Laghi, L.; Nikzad, H.; Capozzi, F. Changes in the Amino Acid Composition of Bogue (Boops boops) Fish during Storage at Different Temperatures by 1H-NMR Spectroscopy. Nutrients 2012, 4, 542–553. [Google Scholar] [CrossRef]
  78. Shumilina, E.; Ciampa, A.; Capozzi, F.; Rustad, T.; Dikiy, A. NMR approach for monitoring post-mortem changes in Atlantic salmon fillets stored at 0 and 4 °C. Food Chem. 2015, 184, 12–22. [Google Scholar] [CrossRef] [Green Version]
  79. Shumilina, E.; Slizyte, R.; Mozuraityte, R.; Dykyy, A.; Stein, T.A.; Dikiy, A. Quality changes of salmon by-products during storage: Assessment and quantification by NMR. Food Chem. 2016, 211, 803–811. [Google Scholar] [CrossRef] [Green Version]
  80. Heude, C.; Lemasson, E.; Elbayed, K.; Piotto, M. Rapid Assessment of Fish Freshness and Quality by 1H HR-MAS NMR Spectroscopy. Food Anal. Methods 2015, 8, 907–915. [Google Scholar] [CrossRef]
  81. Jin, Y.; Cai, H.; Lin, Y.; Cui, X.; Chen, Z. Usage of the ultrafast intermolecular single-quantum coherence (UF iSQC) sequence for NMR spectroscopy of ex vivo tissue. Int. Food Res. J. 2015, 77, 636–642. [Google Scholar] [CrossRef]
  82. Tan, C.; Huang, Y.; Feng, J.; Li, Z.; Cai, S. Freshness assessment of intact fish via 2D 1H J-resolved NMR spectroscopy combined with pattern recognition methods. Sens. Actuators B Chem. 2018, 255, 348–356. [Google Scholar] [CrossRef]
  83. Carneiro, C.; Mársico, E.T.; Ribeiro, R.O.R.; Conte-Júnior, C.A.; Mano, S.B.; Augusto, C.J.C.; de Jesus, E.F.O. Low-Field Nuclear Magnetic Resonance (LF NMR 1H) to assess the mobility of water during storage of salted fish (Sardinella brasiliensis). J. Food Eng. 2016, 169, 321–325. [Google Scholar] [CrossRef]
  84. Sadecka, J.; Tothova, J. Fluorescence Spectroscopy and Chemometrics in the Food Classification—A Review. Czech J. Food Sci. 2007, 25, 159–173. [Google Scholar] [CrossRef] [Green Version]
  85. Karoui, R.; Blecker, C. Fluorescence Spectroscopy Measurement for Quality Assessment of Food Systems—A Review. Food Bioprocess Technol. 2011, 4, 364–386. [Google Scholar] [CrossRef]
  86. Liu, X.; Jing, J.; Li, S.; Zhang, G.; Zou, T.; Xia, X.; Huang, W. Measurement of pyrene in the gills of exposed fish using synchronous fluorescence spectroscopy. Chemosphere 2012, 86, 198–201. [Google Scholar] [CrossRef]
  87. Eaton, J.K.; Alcivar-Warren, A.M.; Kenny, J.E. Multidimensional fluorescence fingerprinting for classification of shrimp by location and species. Environ. Sci. Technol. 2012, 46, 2276–2282. [Google Scholar] [CrossRef] [PubMed]
  88. ElMasry, G.; Nagai, H.; Moria, K.; Nakazawa, N.; Tsuta, M.; Sugiyama, J.; Okazaki, E.; Nakauchi, S. Freshness estimation of intact frozen fish using fluorescence spectroscopy and chemometrics of excitation–emission matrix. Talanta 2015, 143, 145–156. [Google Scholar] [CrossRef]
  89. ElMasry, G.; Nakazawa, N.; Okazaki, E.; Nakauchi, S. Non-invasive sensing of freshness indices of frozen fish and fillets using pretreated excitation–emission matrices. Sens. Actuators B Chem. 2016, 228, 237–250. [Google Scholar] [CrossRef]
  90. Shibata, M.; ElMasry, G.; Moriya, K.; Rahman, M.M.; Miyamoto, Y.; Ito, K.; Nakazawa, N.; Nakauchi, S.; Okazaki, E. Smart technique for accurate monitoring of ATP content in frozen fish fillets using fluorescence fingerprint. LWT 2018, 92, 258–264. [Google Scholar] [CrossRef]
  91. Karoui, R.; Hassoun, A.; Ethuin, P. Front face fluorescence spectroscopy enables rapid differentiation of fresh and frozen-thawed sea bass (Dicentrarchus labrax) fillets. J. Food Eng. 2017, 202, 89–98. [Google Scholar] [CrossRef]
  92. Omwange, K.A.; Al Riza, D.F.; Sen, N.M.; Shiigi, T.; Kuramoto, M.; Ogawa, Y.; Kondo, N.; Suzuki, T. Fish freshness monitoring using UV-fluorescence imaging on Japanese dace (Tribolodon hakonensis) fisheye. J. Food Eng. 2020, 287, 110111. [Google Scholar] [CrossRef]
  93. Pu, Y.-Y.; Feng, Y.-Z.; Sun, D.-W. Recent Progress of Hyperspectral Imaging on Quality and Safety Inspection of Fruits and Vegetables: A Review. Compr. Rev. Food Sci. F 2015, 14, 176–188. [Google Scholar] [CrossRef] [PubMed]
  94. Tito, N.B.; Rodemann, T.; Powell, S.M. Use of near infrared spectroscopy to predict microbial numbers on Atlantic salmon. Food Microbiol. 2012, 32, 431–436. [Google Scholar] [CrossRef] [PubMed]
  95. Reis, M.M.; Martínez, E.; Saitua, E.; Rodríguez, R.; Pérez, I.; Olabarrieta, I. Non-invasive differentiation between fresh and frozen/thawed tuna fillets using near infrared spectroscopy (Vis-NIRS). LWT 2017, 78, 129–137. [Google Scholar] [CrossRef]
  96. Wu, T.; Zhong, N.; Yang, L. Application of VIS/NIR Spectroscopy and SDAE-NN Algorithm for Predicting the Cold Storage Time of Salmon. J. Spectrosc. 2018, 12, 1–9. [Google Scholar] [CrossRef] [Green Version]
  97. Agyekum, A.A.; Kutsanedzie, F.Y.H.; Mintah, B.K.; Annavaram, V.; Zareef, M.; Hassan, M.M.; Arslan, M.; Chen, Q. Rapid and Nondestructive Quantification of Trimethylamine by FT-NIR Coupled with Chemometric Techniques. Food Anal. Methods 2019, 12, 2035–2044. [Google Scholar] [CrossRef]
  98. Alamprese, C.; Casiraghi, E. Application of FT-NIR and FT-IR spectroscopy to fish fillet authentication. LWT 2015, 63, 720–725. [Google Scholar] [CrossRef]
  99. Zhou, J.; Wu, X.; Chen, Z.; You, J.; Xiong, S. Evaluation of freshness in freshwater fish based on near infrared reflectance spectroscopy and chemometrics. LWT 2019, 106, 145–150. [Google Scholar] [CrossRef]
  100. Hernández-Martínez, M.; Gallardo-Velázquez, T.; Osorio-Revilla, G.; Almaraz-Abarca, N.; Ponce-Mendoza, A.; Vásquez-Murrieta, M.S. Prediction of total fat, fatty acid composition and nutritional parameters in fish fillets using MID-FTIR spectroscopy and chemometrics. LWT 2013, 52, 12–20. [Google Scholar] [CrossRef]
  101. Fengou, L.; Lianou, A.; Tsakanikas, P.; Gkana, E.N.; Panagou, E.Z.; Nychas, G.E. Evaluation of Fourier transform infrared spectroscopy and multispectral imaging as means of estimating the microbiological spoilage of farmed sea bream. Food Microbiol. 2019, 79, 27–34. [Google Scholar] [CrossRef] [Green Version]
  102. Saraiva, C.; Vasconcelos, H.; de Almeida, J.M.M.M. A chemometrics approach applied to Fourier transform infrared spectroscopy (FTIR) for monitoring the spoilage of fresh salmon (Salmo salar) stored under modified atmospheres. Int. J. Food Microbiol. 2017, 241, 331–339. [Google Scholar] [CrossRef]
  103. Jia, B.; Wang, W.; Ni, X.; Lawrence, K.C.; Zhuang, H.; Yoon, S.; Gao, Z. Essential processing methods of hyperspectral images of agricultural and food products. Chemom. Intell. Lab. Syst. 2020, 198, 103936. [Google Scholar] [CrossRef]
  104. Cheng, J.; Sun, D. Hyperspectral imaging as an effective tool for quality analysis and control of fish and other seafoods: Current research and potential applications. Trends Food Sci. Technol. 2014, 37, 78–91. [Google Scholar] [CrossRef]
  105. Liu, Y.; Pu, H.; Sun, D. Hyperspectral imaging technique for evaluating food quality and safety during various processes: A review of recent applications. Trends Food Sci. Technol. 2017, 69, 25–35. [Google Scholar] [CrossRef]
  106. Cheng, J.; Sun, D.; Pu, H.; Zhu, Z. Development of hyperspectral imaging coupled with chemometric analysis to monitor K value for evaluation of chemical spoilage in fish fillets. Food Chem. 2015, 185, 245–253. [Google Scholar] [CrossRef]
  107. Cheng, J.; Sun, D.; Qu, J.; Pu, H.; Zhang, X.; Song, Z.; Chen, X.; Zhang, H. Developing a multispectral imaging for simultaneous prediction of freshness indicators during chemical spoilage of grass carp fish fillet. J. Food Eng. 2016, 182, 9–17. [Google Scholar] [CrossRef]
  108. Cheng, J.; Sun, D.W.; Wei, Q. Enhancing Visible and Near-Infrared Hyperspectral Imaging Prediction of TVB-N Level for Fish Fillet Freshness Evaluation by Filtering Optimal Variables. Food Anal. Methods 2017, 10, 1888–1898. [Google Scholar] [CrossRef]
  109. Ivorra, E.; Sánchez, A.J.; Verdú, S.; Barat, J.M.; Grau, R. Shelf life prediction of expired vacuum-packed chilled smoked salmon based on a KNN tissue segmentation method using hyperspectral images. J. Food Eng. 2016, 178, 110–116. [Google Scholar] [CrossRef]
  110. Khoshnoudi-Nia, S.; Moosavi-Nasab, M. Prediction of various freshness indicators in fish fillets by one multispectral imaging system. Sci. Rep. 2019, 9, 14704. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  111. Xu, J.; Riccioli, C.; Sun, D. Development of an alternative technique for rapid and accurate determination of fish caloric density based on hyperspectral imaging. J. Food Eng. 2016, 190, 185–194. [Google Scholar] [CrossRef]
  112. Qu, J.; Sun, D.; Cheng, J.; Pu, H. Mapping moisture contents in grass carp (Ctenopharyngodon idella) slices under different freeze drying periods by Vis-NIR hyperspectral imaging. LWT 2017, 75, 529–536. [Google Scholar] [CrossRef]
  113. Qin, J.; Vasefi, F.; Hellberg, R.S.; Akhbardeh, A.; Isaacs, R.B.; Yilmaz, A.G.; Hwang, C.; Baek, I.; Schmidt, W.F.; Kim, M.S. Detection of fish fillet substitution and mislabeling using multimode hyperspectral imaging techniques. Food Control 2020, 114, 107234. [Google Scholar] [CrossRef]
  114. Afseth, N.A.; Wold, J.P.; Segtnan, V.H. The potential of Raman spectroscopy for characterisation of the fatty acid unsaturation of salmon. Anal. Chim. Acta 2006, 572, 85–92. [Google Scholar] [CrossRef]
  115. Sánchez-Alonso, I.; Carmona, P.; Careche, M. Vibrational spectroscopic analysis of hake (Merluccius merluccius L.) lipids during frozen storage. Food Chem. 2012, 132, 160–167. [Google Scholar]
  116. Janči, T.; Valinger, D.; Kljusurić, J.G.; Mikac, L.; Vidaček, S.; Ivanda, M. Determination of histamine in fish by Surface Enhanced Raman Spectroscopy using silver colloid SERS substrates. Food Chem. 2017, 224, 48–54. [Google Scholar] [CrossRef] [PubMed]
  117. Xie, Z.; Wang, Y.; Chen, Y.; Xu, X.; Jin, Z.; Ding, Y.; Yang, N.; Wu, F. Tuneable surface enhanced Raman spectroscopy hyphenated to chemically derivatized thin-layer chromatography plates for screening histamine in fish. Food Chem. 2017, 230, 547–552. [Google Scholar] [CrossRef]
  118. Deng, D.; Lin, Q.; Li, H.; Huang, Z.; Kuang, Y.; Chen, H.; Kong, J. Rapid detection of malachite green residues in fish using a surface-enhanced Raman scattering-active glass fiber paper prepared by in situ reduction method. Talanta 2019, 200, 272–278. [Google Scholar] [CrossRef] [PubMed]
  119. Velioğlu, H.M.; Temiz, H.T.; Boyaci, I.H. Differentiation of fresh and frozen-thawed fish samples using Raman spectroscopy coupled with chemometric analysis. Food Chem. 2015, 172, 283–290. [Google Scholar] [CrossRef] [PubMed]
  120. Song, S.; Liu, Z.; Huang, M.; Zhu, Q.; Qin, J.; Kim, M.S. Detection of fish bones in fillets by Raman hyperspectral imaging technology. J. Food Eng. 2020, 272, 109808. [Google Scholar] [CrossRef]
Figure 1. Summary scheme of the indirect acquisition techniques reported in the paper (on the left) and of the different statistical algorithms used for the creation of a calibration model (on the right).
Figure 1. Summary scheme of the indirect acquisition techniques reported in the paper (on the left) and of the different statistical algorithms used for the creation of a calibration model (on the right).
Sensors 21 01373 g001
Table 1. Analytical and chemical biosensors.
Table 1. Analytical and chemical biosensors.
SystemMeasured SubstanceSpeciesApplicationLODDetection RangeReference
Amperometric enzymatic biosensorXaCrucian carpContact with sample solution20 nm0.03–21.19 µM[21]
Ammonium ion-selective electrodeVolatile amminesCodPackage atmosphere0.01 ppm1–250 ppm[24]
Amperometric enzymatic biosensorXaChanna striatusContact with sample solution2.5 pM0.4–2.4 nM[30]
Acqueous phase electrodeConductivity/pHCodPackage atmosphere----------[25]
Amperometric enzymatic biosensorXaLabeo fishContact with sample solution0.5 µM0.5–500 µM[31]
Amperometric enzymatic biosensorXaHakeContact with sample solution13 nM0.05–12 µM[32]
Amperometric enzymatic biosensorHystamineCarp, Prussian carp, Tench, Wels catfish, European perchContact with sample solution25.4 nM0.1–300 µM[22]
Organic gas sensorVolatile amminesTilapia, Beltfish, MackerelAir pushed in the sensor chamber0.1 ppm0.1–1 ppm[26]
Graphite electrodeHxA
Xa
UA
Barracuda, Lady fish, Mackerel, Blue cat fish, Channel cat fishContact with sample solution----6–30 µM
8–36 µM
3–21 µM
[27]
Pyrolitic graphite electrodeHxA
Xa
UA
Tuna, Hake, Myleus paku, SilversideContact with sample solution0.08 µM
0.06 µM
0.03 µM
0.1–50 µM
0.1–50 µM
0.1–25 µM
[33]
Carbon electrodeHistamineSpiked tuna, MackerelContact with sample solution0.97 mgL−1----[34]
Copper phosphate electrodeHistamine----Contact with sample solution3.0 ppm5–500 ppm[28]
Cu-BTC frameworkHxA
Xa
----Contact with sample solution----0–10 µM
0–8 µM
[29]
Glassy carbon electrodeXaSalmonContact with sample solution0.35 nM0.001–50 µM[35]
Fluorescent biosensorHxAFish, Shrimp, SquidContact with sample solution2.88 µM8–2500 µM[36]
Table 3. Dielectric techniques.
Table 3. Dielectric techniques.
SystemStudied
Parameter
SpeciesPlace of ApplicationReference
Open-ended
coaxial probe
Storage timeBaltic cod, Atlantic hake, Pacific hake, Atlantic salmonContact with sample[72]
Impedance analyzerDielectric properties and penetration depthSalmonCylindrical samples placed in a test cell[73]
Fish freshness meterFish freshnessCuttlefish, Shortfin squidContact with sample[74]
Fish freshness meterStorage time, icing treatmentsCuttlefishContact with sample[75]
Fish freshness meterDielectric property changes for different icing treatmentsCommon carpContact with sample[76]
Table 4. Nuclear magnetic resonance techniques.
Table 4. Nuclear magnetic resonance techniques.
Spectroscopic TechniqueMeasured ParametersSpeciesReference
1H-NMRAmino acid, organic acid, alcoholsBogue fish[77]
1H-NMRK-valueSalmon[78]
1H-NMRMaximum storage timeSalmon[79]
HR-MASK-value
TMA-N
Sea bream, Sea bass trout, Red mullet[80]
UF–iSQCAmino acids
Fatty acids
Salmon, Shishamo zebra fish[81]
1H 2D J-resolved NMRMetabolites contentZebra fish[82]
LF-NMRWater mobilitySalted sardines[83]
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Share and Cite

MDPI and ACS Style

Franceschelli, L.; Berardinelli, A.; Dabbou, S.; Ragni, L.; Tartagni, M. Sensing Technology for Fish Freshness and Safety: A Review. Sensors 2021, 21, 1373. https://doi.org/10.3390/s21041373

AMA Style

Franceschelli L, Berardinelli A, Dabbou S, Ragni L, Tartagni M. Sensing Technology for Fish Freshness and Safety: A Review. Sensors. 2021; 21(4):1373. https://doi.org/10.3390/s21041373

Chicago/Turabian Style

Franceschelli, Leonardo, Annachiara Berardinelli, Sihem Dabbou, Luigi Ragni, and Marco Tartagni. 2021. "Sensing Technology for Fish Freshness and Safety: A Review" Sensors 21, no. 4: 1373. https://doi.org/10.3390/s21041373

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop