Next Article in Journal
An Improved Weighted Gradient Projection Method for Inverse Kinematics of Redundant Surgical Manipulators
Previous Article in Journal
In-Flight Tests of Intruder Detection Vision System
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Erratum

Erratum: Jamšek et al. Gaussian Mixture Models for Control of Quasi-Passive Spinal Exoskeletons. Sensors 2020, 20, 2705

1
Laboratory for Neuromechanics and Biorobotics, Department of Automation, Biocybernetics and Robotics, Jožef Stefan Institute, 1000 Ljubljana, Slovenia
2
Jožef Stefan International Postgraduate School, Jamova cesta 39, 1000 Ljubljana, Slovenia
*
Author to whom correspondence should be addressed.
Sensors 2021, 21(21), 7359; https://doi.org/10.3390/s21217359
Submission received: 15 July 2021 / Accepted: 23 August 2021 / Published: 5 November 2021
(This article belongs to the Section Physical Sensors)
There was an error in the original article [1]. The variable used for the superscript in the denominator of the equation, denoting the dimensionality of the model, was incorrectly written as K and thus conflicted with the variable denoting the number of Gaussian mixtures. A correction has therefore been made to Section 2.3, Equation (4):
p j ( x ) = k = 1 K τ k e 1 2 ( x μ k ) T Σ k 1 ( x μ k ) ( 2 π ) D | Σ k | ,
where D is the dimensionality of the model (6 in our case).

Reference

  1. Jamšek, M.; Petrič, T.; Babič, J. Gaussian Mixture Models for Control of Quasi-Passive Spinal Exoskeletons. Sensors 2020, 20, 2705. [Google Scholar] [CrossRef] [PubMed]
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Share and Cite

MDPI and ACS Style

Jamšek, M.; Petrič, T.; Babič, J. Erratum: Jamšek et al. Gaussian Mixture Models for Control of Quasi-Passive Spinal Exoskeletons. Sensors 2020, 20, 2705. Sensors 2021, 21, 7359. https://doi.org/10.3390/s21217359

AMA Style

Jamšek M, Petrič T, Babič J. Erratum: Jamšek et al. Gaussian Mixture Models for Control of Quasi-Passive Spinal Exoskeletons. Sensors 2020, 20, 2705. Sensors. 2021; 21(21):7359. https://doi.org/10.3390/s21217359

Chicago/Turabian Style

Jamšek, Marko, Tadej Petrič, and Jan Babič. 2021. "Erratum: Jamšek et al. Gaussian Mixture Models for Control of Quasi-Passive Spinal Exoskeletons. Sensors 2020, 20, 2705" Sensors 21, no. 21: 7359. https://doi.org/10.3390/s21217359

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop