Optimized Lateral Flow Immunoassay Reader for the Detection of Infectious Diseases in Developing Countries
Department of Electronic and Electrical Engineering, University College London, Torrington Place, WC1E 7JE London, UK
*
Author to whom correspondence should be addressed.
Sensors 2017, 17(11), 2673; https://doi.org/10.3390/s17112673
Received: 19 October 2017 / Revised: 14 November 2017 / Accepted: 17 November 2017 / Published: 20 November 2017
(This article belongs to the Special Issue Sensors for Health Monitoring and Disease Diagnosis)
Detection and control of infectious diseases is a major problem, especially in developing countries. Lateral flow immunoassays can be used with great success for the detection of infectious diseases. However, for the quantification of their results an electronic reader is required. This paper presents an optimized handheld electronic reader for developing countries. It features a potentially low-cost, low-power, battery-operated device with no added optical accessories. The operation of this proof of concept device is based on measuring the reflected light from the lateral flow immunoassay and translating it into the concentration of the specific analyte of interest. Characterization of the surface of the lateral flow immunoassay has been performed in order to accurately model its response to the incident light. Ray trace simulations have been performed to optimize the system and achieve maximum sensitivity by placing all the components in optimum positions. A microcontroller enables all the signal processing to be performed on the device and a Bluetooth module allows transmission of the results wirelessly to a mobile phone app. Its performance has been validated using lateral flow immunoassays with influenza A nucleoprotein in the concentration range of 0.5 ng/mL to 200 ng/mL.
View Full-Text
Keywords:
infectious diseases; lateral flow immunoassay; point of care; ray trace simulation; reader
▼
Show Figures
This is an open access article distributed under the Creative Commons Attribution License which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited
MDPI and ACS Style
Pilavaki, E.; Demosthenous, A. Optimized Lateral Flow Immunoassay Reader for the Detection of Infectious Diseases in Developing Countries. Sensors 2017, 17, 2673. https://doi.org/10.3390/s17112673
AMA Style
Pilavaki E, Demosthenous A. Optimized Lateral Flow Immunoassay Reader for the Detection of Infectious Diseases in Developing Countries. Sensors. 2017; 17(11):2673. https://doi.org/10.3390/s17112673
Chicago/Turabian StylePilavaki, Evdokia; Demosthenous, Andreas. 2017. "Optimized Lateral Flow Immunoassay Reader for the Detection of Infectious Diseases in Developing Countries" Sensors 17, no. 11: 2673. https://doi.org/10.3390/s17112673
Find Other Styles
Note that from the first issue of 2016, MDPI journals use article numbers instead of page numbers. See further details here.
Search more from Scilit