Characterization and Quantification of Selenoprotein P: Challenges to Mass Spectrometry

1
IPREM UMR5254, E2S UPPA, Institut des Sciences Analytiques et de Physico-Chimie Pour l’Environnement et les Matériaux, CNRS, Université de Pau et des Pays de l’Adour, Hélioparc, 64053 Pau, France
2
World-Class Research Center “Digital Biodesign and Personalized Healthcare”, IM Sechenov First Moscow State Medical University (Sechenov University), 119435 Moscow, Russia
3
Chair of Analytical Chemistry, Warsaw University of Technology, Noakowskiego 3, 00-664 Warsaw, Poland
*
Author to whom correspondence should be addressed.
Int. J. Mol. Sci. 2021, 22(12), 6283; https://doi.org/10.3390/ijms22126283
Submission received: 4 May 2021 / Revised: 5 June 2021 / Accepted: 7 June 2021 / Published: 11 June 2021
(This article belongs to the Section Biochemistry)

Abstract

:
Selenoprotein P (SELENOP) is an emerging marker of the nutritional status of selenium and of various diseases, however, its chemical characteristics still need to be investigated and methods for its accurate quantitation improved. SELENOP is unique among selenoproteins, as it contains multiple genetically encoded SeCys residues, whereas all the other characterized selenoproteins contain just one. SELENOP occurs in the form of multiple isoforms, truncated species and post-translationally modified variants which are relatively poorly characterized. The accurate quantification of SELENOP is contingent on the availability of specific primary standards and reference methods. Before recombinant SELENOP becomes available to be used as a primary standard, careful investigation of the characteristics of the SELENOP measured by electrospray MS and strict control of the recoveries at the various steps of the analytical procedures are strongly recommended. This review critically discusses the state-of-the-art of analytical approaches to the characterization and quantification of SELENOP. While immunoassays remain the standard for the determination of human and animal health status, because of their speed and simplicity, mass spectrometry techniques offer many attractive and complementary features that are highlighted and critically evaluated.

1. Introduction

Selenium, originally known for its toxicity, was subsequently recognized as an essential trace element [1] and has been increasingly marketed as a life-style drug [2]. The importance of Se is related to its antioxidant properties, its role in the endocrine and immune system, as well as its involvement in the protection against certain diseases, such as cancer, diabetes, cardiovascular or immune system disorders [3]. The narrow range of the optimum selenium concentration in biological fluids, the multiplicity of its chemical forms and the diversity of its biological activities are driving interest for precise molecular markers of its status in various organisms.
The activity of Se is mainly mediated by selenoproteins. They contain in their sequence at least one selenocysteine (SeCys, U), which is genetically encoded and often referred to as the 21st amino-acid [4]. In the presence of a specific stemloop RNA sequence element (SECIS), the UGA codon, normally acting as a stop codon to terminate translation, codes for the insertion of SeCys into a polypeptide chain [2,5]. The pioneering works of Gladyshev group [6,7] started the development of algorithms predicting the existence of many selenoproteins in different biological species [8,9]. The number of selenoproteins that can be expressed in different organisms varies, ranging from 1 in certain insects, to 9 in common spider, 25 in humans [10], and 32 in oysters [11]. In vertebrates, the mRNA encoding SELENOP is distinct from that encoding other selenoproteins, in that it contains two SECIS elements instead of one [12].
Selenoprotein P is unique amongst all the characterized selenoproteins in that it contains multiple SeCys residues, whereas all other selenoproteins contain only one SeCys. The number of SeCys residues in SELENOP from different organisms varies (Figure 1), amounting to 10 for humans, 46 in oysters [11] and 132 in one-species bivalves [13].
SELENOP was first reported in 1973 by Burk et al. [15] and Rotruck et al. [16]. McConnell et al. [17] and Motsenbocker et al. [18] found that SELENOP was synthetized in the liver of rats and secreted into the plasma. A few years later, the existence of SELENOP was confirmed in humans, where it is considered as a valuable marker for nutritional selenium status [19]. In 2016, Gladyshev et al. proposed a non-ambiguous notation for all selenoproteins using the root symbol SELENO followed by a letter, leading to the creation of the abbreviation SELENOP for selenoprotein P, replacing the previously used as abbreviations such as SeP, SEEP1, SelP [20]. Expression, functions and role of SELENOP in mammals were reviewed [21].
As a biomarker, SELENOP can discriminate between the specific and nonspecific (and therefore non-significant) incorporation of Se in proteins [22,23]. It responds to Se supplementation over a wider range of intakes than GPx3 [24]. In marginally supplied individuals, low serum Se was found to be mirrored by the circulating SELENOP concentration, but not by the GPx3 activity [25]. In studies of populations with relatively low selenium intakes, SELENOP was found to respond to different dietary selenium forms [26]. Serum SELENOP concentration can be more than a biomarker of Se status: it was proposed to be used for the diagnosis and assessment of treatment efficacy and long-term prognosis in patients with pulmonary arterial hypertension [27] and hypertension [28]. Recently, the mortality risk from COVID-19 was shown to be associated with selenium deficiency, and more specifically with SELENOP deficiency, causing a dysregulation of the redox homeostasis in pathological conditions which resulted in an excessive reactive oxygen species (ROS) generation [29,30].
During the last 40 years, many functions have been attributed to SELENOP including its involvement in the storage of selenium in the brain, testis [23,31] and kidney [32], defence against oxidative stress [33], loss of fertility [23], polycystic ovary syndrome [34] or regulation of heavy metals concentration [35,36]. SELENOP was reported to play a role in the potential development of various forms of cancer [37,38,39,40] and to be associated with neurodegenerative diseases such as Alzheimer’s [39,41,42,43]. SELENOP was evoked as a therapeutic target for type 2 diabetes [41,44,45,46] because of its role in the regulation of glucose metabolism and insulin sensitivity. Recent advances in the understanding of the role of SELENOP and its potential medical/pharmaceutical implications were reviewed [47].
In order to fully elucidate the mode of action and the importance of SELENOP in the different pathological pathways, a complete structural characterization, quantitative determination and localization of SELENOP in the tissues are needed [48]. Mass spectrometry techniques are uniquely placed to address these ongoing challenges. The goal of this review is to critically discuss the current state of-the-art analytical methods for the characterization and determination of SELENOP, identify the open questions and indicate how they can be answered.

2. Selenoprotein P Characteristics

To date, the three-dimensional structure of SELENOP has not been solved. A possible reason for this is the difficulty in the exogenous over-expression of SELENOP in bacteria or in cultured cells, because of the presence of multiple Sec residues in the polypeptide [47]. Studies using recombinant SELENOPP have been rare [49]. Consequently, the SELENOP characterization was carried out on protein expressed endogenously by cell lines or purified from plasma and serum.
The matured predominant isoform of human SELENOP consists of 359 amino acids (AA) after cleavage of the predicted signal peptide (AA 1–21) [47] (Figure 2a). The selenium content (as SeCys) of SELENOP is distributed into two parts [21,47]. The N-terminal domain contains one selenocysteine at the 40th amino-acid in a U-x-x-C redox motif. The shorter C-terminal domain contains multiples selenocysteine, up to 9 in total for rats, mice, and humans [50,51] The N-terminal domain is responsible for the enzymatic activity of this protein, while the C-terminal domain acts as the Se supplier [52] (Figure 2b).
SELENOP is not a homogenous protein. As a consequence of the SeCys gene expression by stop codon recoding, multiple forms of the SELENOP of different molecular weight exist in terms of relation to genotype, differential splicing, premature interrupted translation at one of the UGA codons, limited post-translational proteolysis or partial replacement of SeCys by Cys [47,54,55,56,57]. To date, four isoforms have been identified in rat plasma. Beside the full-length isoform with 10 selenocysteine residues, shorter isoforms terminating at the 2nd, 3rd, and 7th selenocysteine [56], with 1, 2 and 6 selenocysteines, respectively, were reported [58]. Interestingly, in a study involving ca. 2000 subjects, the average determined number of Se atoms per SELENOP molecule (5.4) was considerably below the predicted number of 10 Se atoms [59].
In the native form, SELENOP contains selenenylsulfide and disulfide bridges. It possesses three N-glycosylation sites at the N-terminus and one O-glycosylation site at the C-terminus [60] and thus, can be referred to as glycoprotein. One highly glycosylated form is secreted by the liver [61]. Selenium-supplemented HepG2 hepatoma cells secrete N-glycosylated SELENOP as well [62]. The post-translational modifications are thought to confer a particular structural behavior to SELENOP and to protect selenium by reducing its reactivity [10].

3. Isolation of Selenoprotein P from Biological Samples Prior to Mass Spectrometry (MS) Characterization

SELENOP is typically present in serum at a level of ca. 50 ng/mL. Its concentrations in cultured cells, breast milk, or tissues are an order of magnitude lower. The abundance of SELENOP in human serum exceeds that of plasma glutathione peroxidase (GPx) and selenized albumin (SeAlb) [31].
Taking into account the presence of a multitude of proteins in a 1000-fold excess, any characterization of SELENOP by mass spectrometry should be preceded by its isolation and enrichment. The methods are usually based on the immunoaffinity precipitation or chromatography (mono- and/or poly-clonal antibodies) [52,58,63,64,65,66] or chemical affinity (heparine [56,67,68] or immobilized transition metals [49,69]).

3.1. Immunoaffinity Precipitation and Chromatography

The use of immunoaffinity has been largely explored for isolation of SELENOP, but this strategy is critically dependent on the quality and selectivity of antibodies. The cross-activity of one antibody with an antigen from different species is not granted and must be tested. Moreover, the activity of the antibody is highly variable for the serum of one animal to the other and must also be systematically tested.
The first purification of SELENOP by immunoprecipitation was performed from rat serum, using monoclonal antibodies [63]. Subsequently, Akesson et al. [58] used the rat monoclonal antibodies for purification of human SELENOP. Other groups reported the preparation [64,70] or use [71] of monoclonal antibody raised against rat SELENOP [64]. No cross-reactivity with plasma from five animal species [58] was observed. Commercially available antibodies against murine SELENOP do not cross react with the human orthologue [69]. Recombinant rat SELENOP was efficiently immunoprecipitated by a commercial penta-histidine antibody but not by the tetrahistidine one [49].
Considerable developments in the field of SELENOP antibodies have taken place in the recent years driven by the need for the development of ELISA kits (see below). They are based on the use of antibodies prepared by using recombinant mutant SELENOP as immunogen. These expressed SELENOP mutants are characterized by the absence of SeCys which are all replaced by Cys [72] or Ser [73]. A recombinant SELENOP commonly used as immunogen for commercial antibody development encompasses the 60-299 SELENOP sequence without SeCys residues [74]. Alternatively, SELENOP purified from human serum was employed as immunogen [52,70,75].
The antibody-based methods for purification and measurement of SELENOP may not allow the distinction among the isoforms [56]. Indeed, antibodies are usually directed towards one of its domains (N or C). Consequently, they capture not only full-length SELENOP but also its N- or C-terminal side domain fragments. In vivo, SELENOP is cleaved by plasma kallikrein which generates N-terminal and C-terminal fragments of SELENOP [75]. The combined use of antibodies specific for N- or C-terminal SELENOP side domain fragments allows the differentiation between the full-length SELENOP from total SELENOP (truncated and full length) [52,54,66].
Technically speaking, immunoprecipitation of SELENOP can be conveniently performed with commercial antibodies conjugated to polystyrene superparamagnetic beads [65]. GPx3 is co-immunoprecipitated with SELENOP, resulting in incomplete separations which is likely to be due to the similarity in the structure of the N-terminal part of SELENOP and GPx3 [65]. This point has not been addressed by recent studies where combined antibodies specific for the different SELENOP termini were employed.

3.2. Heparin Affinity Methods

Two histidine-rich stretches containing up to 10 sequential basic amino acids are present in the 185–198 and 225–234 amino-acid sequences in rats [67]. The rat and human SELENOP sequences encode two His-rich regions: the first region consists of 8 (rat) or 9 (human) histidines out of 14 residues, and the second, a stretch of 7 (rat) or 4 (human) consecutive histidines [76]. The presence of these stretches confers to SELENOP a feature of binding to heparin [67].
SELENOP binds to heparin as a function of pH. The binding is facilitated by an increase in protonation of histidine residues. Therefore, SELENOP will bind to heparin under acidic conditions but remains unbound at physiological pH [21]. The pKa of histidine (7.0) explains the release of SELENOP from heparin at alkaline conditions [67].
Heitland et al. were able to isolate SELENOP using heparin column from other serum proteins with a total recovery of selenium (96%) [68]. A recovery above 90% was reported [77]. Problems linked to nonspecific adsorption of plasma-extracellular glutathione peroxidase (GPx) and albumin on the heparin affinity column were evoked [77].
Purified SELENOP can be separated in three peaks using heparin chromatography suggesting its capability to discriminate amongst the isoforms [56].

3.3. Immobilized Metal Affinity Methods (IMAC)

These histidine-rich regions in conjunction with the Cys and SeCys content, are likely responsible for the coordination to heavy metals such as, e.g., mercury [76]. The presence of such motifs makes it possible to retain SELENOP on an IMAC-sepharose column loaded with cobalt [69]. Co2+ was found superior to Cu2+, Ni2+, Zn2+, and Cd2+ for metal affinity LC [69].
The Ni-agarose chromatography was performed using Ni-NTA spin columns and turned out to be efficient for the isolation of SELENOP, prior to SDS PAGE and Western blotting analysis [49].

3.4. Sequential Purifications

In order to increase the purity of the isolated SELENOP, the above discussed steps can be employed in a sequence. Akesson et al. reached a 1000-fold purification of SELENOP by combining immunoaffinity LC and heparin [58]. The immunoaffinity purified protein was further separated into several forms using heparin-sepharose column [64].
Daegen et al. separated plasma into three components (GPx, SELENOP, and Alb) using heparin-sepharose and blue 2-sepharose (to remove SeAlb) [78]. A combination of IMAC and heparin offered a 15,000-fold enrichment of SELENOP [69]. Isolation of electrophoretically pure SELENOP was reported to be achieved in three steps: heparin agarose, ultrafiltration concentration, anion-exchange, Ni-NTA-agarose [61]. The combination of heparin-sepharose CL-GB, Q Sepharose F and Ni-NTA agarose chromatography, followed by desalting by gel filtration, allowed a 13,000-fold purification of SELENOP with an overall yield of 16% [79]. The low yield of sequential purification is often due to the multiplication of steps inducing loss of protein. In recent studies, the use of heparin was shown to be the most efficient for SELENOP purification with a yield of 96% [68], however this method does not concentrate the protein.

4. Detection and Characterization of SELENOP by Soft Ionization Mass Spectrometry

The isolated SELENOP can be formally identified without mass spectrometry by the N-terminal amino-acid sequence (or microsequencing) [79]. However, the advantage of MS in terms of sensitivity and speed cannot be overestimated. So far, to our knowledge, there have been no mass spectra published for the intact full-length SELENOP and their truncated isoforms. Most of the published MS data concern the analysis of peptides, obtained after tryptic digestion, by matrix-assisted laser desorption ionization (MALDI) or electrospray ionization MS. The latter allows the determination of the peptide sequence upon collision induced fragmentation (MS/MS). The list of the reported peptides allowing the 100% sequence specificity and they correspondence to full-length or truncated isoforms is given in (Table 1).
A number of bioinformatic tools have been developed for the detection of selenoproteins in high throughput MS schemes [9,80]. Several enzymes (such as trypsin or endoproteinase) can be used to lyse the proteins and to obtain different SELENOP characteristic peptides. The inconvenience of bottom-up proteomics approaches is that it is not always possible to identify isoforms from which the peptides are derived. Their advantage is the capability to deal with the post-translational modification.
The major challenges in mass spectrometry analysis include the ability to be able to distinguish between isoforms, to complete the characterization of truncated forms and to develop analytical methods for their quantification. The potential of top-down proteomics for this purpose is very promising [81].

4.1. MALDI-MS

MALDI-MS allowed the discovery in rat plasma of three SELENOP isoforms that have identical N-termini, and differ in the length of the amino-acid chain [56]. The full-length SELENOP and the isoforms were separated by SDS PAGE. They were reduced, alkylated, deglycosylated and digested with trypsin. Additional peptides could be identified by digestion with Glu-C of the SelP isolated by heparin, without the need for its subsequent purification by SDS PAGE. Mass spectrometry could identify the C-termini of the isoforms according to the prediction (at the 2nd, 3rd and 7th selenocysteine residue) [56].
MALDI-MS was also used to identify the sites of glycosylation of the full-length SELENOP [60]. The procedure was based on a treatment with PNGase F, which cleaves off asparagine-linked carbohydrates and converts the residue asparagine to aspartic acid. Of the five potential glycosylation sites, three located at residues 64, 155 and 169 were occupied, and two at residues 351 and 356 were not occupied. Threonine 346 was variably O-glycosylated. Full-length SELENOP was found to be both N- and O-glycosylated [60].
MALDI-MS was also essential in the identification of Se-S and disulfide linkage sites [60]. The strategy of sample preparation for the determination of the oxidation state of the cysteine residues consisted of the alkylation of all free cysteines and selenocysteines in the short form of SELENOP with iodoacetamide, digestion with endoproteinase, and deglycosylation [60]. A selenide-sulfide bond was found in the shortened isoform to be analogous to the selenol-thiol pair considered to be redox-active [60]. Two selenylsulfide bonds were identified by MALDI-MS in a peptide isolated from a tryptic digest of rat SELENOP [82].

4.2. Electrospray MS

The basic advantage of electrospray ionization (ESI) MS over MALDI is the possibility to sequence peptides in LC-MS/MS on the basis of the m/z of their b and y fragments. ESI MS was used to verify the sequences of the putative glycosylated peptides in rat SELENOP [60] and the confirmation of the existence of disulphide linkages [60,82].
High pressure liquid chromatography (HPLC)-MS/MS was a convenient technique for the identification of SELENOPeptides in a tryptic digest of purified SELENOP. It allowed the formal confirmation of SELENOP presence in human breast milk [83]. A sequence with a coverage of 80% of the theoretical one was reported on the basis of the tryptic digest analysis, and two SELENOPeptides were formally identified [83].
SELENOP, being a low-abundant protein in serum, was not detected by a regular shotgun proteomics approach [84]. The analysis of the fraction purified by heparin allowed the detection of three unique SELENOP peptides identified by only one post-translational modification for each, and a sequence coverage of 41.5% [84]. The purification of SELENOP by SDS PAGE and blotting, which was followed by tryptic digestion and HPLC-MS/MS, allowed the identification of 7 SelP peptides totalling 115 post-translational modifications (none of which contained selenium) in the 49 kdaSELENOP band in the blot, accounting for a sequence coverage factor of 17.7%. Selenium contained peptides missed by the regular shotgun proteomics procedure. The identification of two SELENOPeptides increased the sequence coverage to 24.4% [84]. Three isoforms of SELENOP were identified by this method [65].
Human SELP still needs a complete MS characterization covering all the SELENOPeptides. The recent data obtained are summarized in Table 1.
The developments in soft ionization mass spectrometry open new perspectives in the detection of SELENOP in broad scope proteomic studies. The method is based on nano-flow liquid chromatography (LC) with electrospray MS/MS detection and data-independent acquisition MS [85]. For instance, label-free proteomics showed selenoprotein P as the most abundant proteins in milk of cows, more precisely, in cows producing milk with A2A2-β-casein variants [86]. The protocols can be quantitative by using isobaric tagging for relative and absolute Quantification (iTRAQ) [80,87,88,89].
Table 1. List of SELENOPeptides used for the SELENOP mass spectrometry identification on the basis of a partial sequence (peptides with the same sequence are highlighted in colors).
Table 1. List of SELENOPeptides used for the SELENOP mass spectrometry identification on the basis of a partial sequence (peptides with the same sequence are highlighted in colors).
MatrixSELENOP Specific Sequence with Sec DetectedIdentified IsoformRef.
Rat plasma28GTVTVVALLQASUYLCLLQASRLE51
239QGHLESUDMGASEGLQLSLAQR260
252GLQLSLAQRKLURRGCINQLLCKLSEE278
298SGSAITUQCAENLPSLCSUQGLFAEEK324
333SPPAAUHSQHVSPTEASPNUSUNNK357
348 ASPNUSUNNKTKKUKUNLN366
4 Isoforms:
50 kDa (full length)
49 kDa (terminated at 351)
38 kDa (terminated at 262)
36 kDa (terminated at 244)
[56]
Rat plasma28GTVTVVALLQASUYLCLLQASR49
328SCQCRSPPAAUHSQHVSPTE347
1 Isoform terminated at 244[60]
Rat plasma298SGSAITUQCAENLPSLCSUQGLFAEEK324n.d.[82]
Human plasma322ENLPSLCUQGLR334
335AEENITESCQUR346
n.d.[84]
Human plasma312TGSAITUQCK321
322ENLPSLCSUQGLR334
335AEENITTESCQUR346
3 Isoforms:
45 kDa (terminated at 299)
49 kDa (n.d.)
57 kDa (n.d.)
[65]
Human breast milk312TGSAITUQCKENLPSLCSUQGLR334
370NQAKKUEUPSNC382
n.d.[83]
Human serum299SUCCHCR305
311TGSAITUQCK321
322ENLPSLCSUQGLR334
335AEENITESCQUR346
347LPPAAUQISQQLIPTEASASUR368
368UKNQAK374
375KUEUPSN381
n.d.[90]
Human serum38DQDPMLNSNGSVTVVALLQASUYLCILQASK68
311TGSAITUQCK321
322ENLPSLCSUQGLR334
335AEENITESCQUR346
347LPPAAUQISQQLIPTEASASUR368
n.d.[91]
n.d.: no data.

5. Quantification of SELENOP

5.1. Immunoassays

Originally, radioimmunoassays based on the in-vitro synthesized or partially purified labeled SELENOP preparations were proposed by [19,63,92,93]. Nevertheless, due to the cumbersome procedures and restrictive regulations concerning the use of radioactive materials, these assays were only used in very few studies and were not widely adopted by the larger community.
ELISA (enzyme-linked immunosorbent assay) for SELENOP was first developed as early as 2010 [24], but the early ELISA assays were time consuming and inconvenient for clinical use. However, the approach is rapidly gaining popularity for the absolute quantification of SelP in plasma samples [59,94]. Several kits are commercially available [73,74,95,96,97]. The results depend largely on the kit used and caution and criticism are required when comparing data obtained with the different kits [98].
The accuracy of the results depends on the epitope identified by the antibody and its selectivity (activity towards the other proteins). If an antibody recognizes just, for example, the N-terminal, the assays will capture not only full-length SELENOP but also the SELENOP-N-terminal fragment [52]. An assay using colloidal gold particles coated with two types of anti-SELENOP monoclonal antibodies, one recognizing the N-terminal side domain and the other recognizing the C-terminal, was developed for measuring full-length selenoprotein P in human serum [52].
The in-plate variation, within-laboratory variation, and between laboratory variation are all typically below 15% with a limit of quantification of 10 ng/mL [59]. The accuracy of ELISA (difference with the SRM value) was assessed to be 2.9% [59]. Because of the limited presence of mass spectrometry technology in the clinical environment, immunoassays are the most widely used technique for human and animal health status.

5.2. Liquid Chromatography—Inductively Coupled Plasma—Mass Spectrometry(ICP-MS)

SELENOProtein P can be quantified by measuring the Se response provided that the protein is separated from the other Se-containing species by HPLC. The initial use of hydride generation atomic absorption or fluorescence spectrometry was replaced by ICP-MS because of its higher sensitivity, isotopic specificity and simplicity avoiding the need for post-column chemical conversion of SELENOP to Se or to selenium hydride. Because of the high relative abundance of SELENOP, the challenge of separation is practically limited to SELENOP from selenoalbumin, GPx3, and selenometabolite fraction.
The principle of the methods is based on downscaling and on-line arrangement in different configurations of the three principal techniques discussed above: size-exclusion LC for the separation according to the molecular weight, heparin LC for the selective retention of SELENOP, and Blue-Sepharose column for the selective retention of SeAlb. As a result, the SELENOP signal is obtained in the form of a chromatographic peak, other species may sometimes be separated by SEC. The principle of the proposed arrangements and the type of signal used for quantification is schematically shown in (Figure 3).
The most widely used principle for the on-line isolation of SELENOP consists of the retention of SELENOP by affinity using a heparin column while all other selenium species are eluted and detected as a peak in the loading run [68]. The subsequent elution run produces a peak corresponding to SelP (Figure 3a). The incorporation of a SEC (heparine) column on-line, either preceding [83,99] (Figure 3b) or following [77] (Figure 3c), allows the discrimination of the selenium species eluting in the loading run into HMW Se-containing proteins (Se-albumin and GPx) and LMW metabolite fraction.
A more sophisticated version of the system includes a switching valve and a circuit containing a column with an affinity for albumin, allowing for the specific recovery of SelAlb during the loading run for its subsequent quantification (Figure 3d) [84,100,101,102,103]. It can be refined by the integration of a SEC column into the system (Figure 3e–f) [104,105,106,107].
Size-exclusion LC alone does not offer a sufficient resolution nor preconcentration to separate SELENOP form SelAlb [112,113]. However, when coupled in-tandem with a SelAlb method, SELENOP appears as a peak partially separated from GPx3 and separated from LMW selenometabolite fraction (Figure 3g) [108].
Alternatively, as SelP is the only selenoium species in serum and cerebrospinal fluid not retained on the anion-exchange column; anion-exchange HPLC (Figure 3h) was used to separate it from other species [109,110,111].

5.2.1. Selectivity and Sensitivity ICP-MS Detection

ICP-MS allows a specific detection of the individual selenium isotopes. Selenoprotein P can be therefore quantified via its selenium content once it has been separated from the other selenium-containing species. Even if the sensitivity of ICP-MS for selenium is inferior to that for most metals because of its higher first ionization potential (9.75 eV), higher proneness to matrix suppression, and the split of ions available among six isotopes, it is fully compatible with the requirements for SELENOP detection in HPLC.
The main problem is the choice of the least interfered isotope as all the Se isotopes can be interfered by polyatomic ions: Ar2 dimers or Ar combinations with Br, S, or Br. A possible interference is 156Gd in serum of patients having received Gd contrast agents were also evoked [68]. The interfering elements can be separated by HPLC [102] and are usually not a problem which favors the choice of 77Se (7.63% abundance) or 82Se (8.73%). The interference on 78Se+ can be effectively eliminated by the use of a H2 pressurized collision cell [114]. The use of the most abundant 80Se (49.6%) requires the removal of the Ar2+ ions which can be achieved by using a collision cell installed between two quadrupoles as it is the case in the ICP-MS/MS instruments [114]. The latter also allows the non-interfered detection of the 80Se16O+ ion produced by the oxidation of Se in the reaction cell [114].

5.2.2. Calibration and Quantification

A major problem in the quantification of SELENOP is the non-availability of an authentic SELENOP standard as it is currently practically impossible to obtain recombinant SELENOP in reasonable purity and quantity. Calibration is therefore carried out using a proxy such as selenite, selenomethionine, a peptide characteristic of SELENOP, or recombinant homologue of SELENOP in which the Sec residues were replaced by Cys.
The standards used for calibration are usually isotopically labeled. However, the term “isotope dilution analysis (IDA)” frequently used in the context of quantification of SELENOP by HPLC-ICP-MS does not bear the original meaning of absolute (traceable to SI units) quantification. As there is not isotopically labeled SELENOP available, the analyte (SELENOP) and the spike used are not in the same chemical form.
The principal quantification strategies of SELENOP using calibration by isotope dilution are based on:
  • the measurement, in an HPLC peak, of the intensity ratio between the natural selenium isotope from the SELENOP after HPLC separation of the latter and the enriched Se (77Se, 74Se) added post-column as SeMet or selenite (“spike”). The method is referred to as species-unspecific isotope dilution [83,84,101,104,105,107].
  • the measurement, in an HPLC peak, of the intensity ratio between Se in selenomethionine obtained by the complete proteolysis of the selenoprotein and the isotopically enriched 77SeMet standard (“spike”). The method can be referred as species-specific isotope dilution on the amino-acid level. The proof of principle was demonstrated by Ruiz Encinar et al. [115] and the approach was applied to the SELENOP quantification by Jitaru et al. [116].
  • the measurement, in an HPLC peak, of the intensity ratio between the Se in a Se-containing peptide obtained from a selenoprotein by tryptic digestion and the isotopically enriched Se (77Se, 74Se) in the identical synthetic peptide. The addition of peptide spikes to the plasma samples was followed by tryptic digestion, alkylation, and isotope ration determination using HPLC-ICP-MS. The principle of the method was demonstrated by Polatajko et al. [117]. The method was first applied to the quantification of SELENOP by Ballihaut et al. [84]. Deitrich et al. [53] proposed the use of two synthetic peptides (isotopically enriched, Se76) derived from SELENOP for its quantification by IDA-ICP-MS/MS. The disadvantage is the introduction of additional uncertainty due to the necessity of control of the efficiency of the enzymatic digestion the use of SELENOPeptides [105].
  • the use of a proxy protein as standard. The closest proxy protein has been for the moment a full-length human recombinant SELENOP in which the original 10 SeCys residues (Sec) were replaced by 10 cysteines (Cys). This replacement was achieved by point mutations of nucleotide triplets coding Sec to triplets coding Cys in the coding sequence for selenoprotein present in the expression vector used as a template for E.coli protein synthesis [100]. Selenium was introduced in the polypetide chain during cell-free protein E.coli synthesis in the form of SeMet or 76Se-Met for the preparation of the SEPP1 standard and an isotopically labeled spike for isotope dilution analysis [118,119]. The standard and spike were purified by SDS PAGE [100]. However imperfect the assumption of the similarity of the behavior of the standard and the spike might be, the use of such an isotopically enriched spike allowed the quantification by standard addition and isotope dilution analysis by ICP-MS after the purification of SELENOP by affinity chromatography.

5.3. Gel-Electrophoresis-Based Methods

Isoelectric focusing (IEF) and sodium dodecyl sulphate-polyacrylamide gel-electrophoresis (SDS-PAGE) allow for the separation of full-length and truncated SELENOP forms. The quantification of SELENOP and its isoforms in the produced band(s) can be achieved by the detection of selenium (either radioactive or not) or directly by the detection of the protein (recognized by a specific antibody).
The mature SELENOP has a molecular mass of 41 kDa but migrates as multiple bands, of approximately 50–60 kDa in SDS PAGE, probably due to variations in glycosylation (conserved 2 N-linked—and one O-linked glycosylation) [47]. Deglycosylation shifts the migration band from 57 kDa to 43 kDa [93]. A small difference can bee seen in mobility (69 kDa under nonreducing conditions) and 66 kDa under reducing conditions [79].

5.3.1. 75Se Detection

The migration of 75Se radioactivity in the gel played a fundamental role in the early works, allowing for the discovery and rough characterization of SELENOP [17,18]. The comparison of the radioactivity in the band with that of a standard is a straightforward method of quantification. An additional advantage is a convenient evaluation of SELENOP recovery from the gel. The inconvenience is the need for handling gamma-radioactivity which requires dedicated laboratories. Note that the technique requires that the quantified 75Se is present in the radioactive form. Whereas it is an elegant quantification technique in animal studies, it is not an option for human SELENOP.

5.3.2. Western Blotting Detection

The principle of the method consists of the separation of SELENOP by SDS PAGE and its transfer onto a PVDF membrane. The membranes are subsequently incubated with primary and secondary antibodies and developed with enhanced chemiluminescence. Standard curves were constructed using a dilute NIST1950 reference material [49,96].
The method is particularly attractive in combination with immunoprecipitation [55,65] allowing the isolation and preconcentration of SELENOP from complex samples.
The selectivity of the method depends less critically on the quality of antibodies than in the case of ELISA as SDS PAGE offers an additional separation step. The method does not account for losses at the different stages of the procedure, but many of these losses are compensated by the calibration with a standard reference material. Western blotting is robust but is not traceable to the SELENOP sequence.

5.3.3. Laser Ablation-ICP MS Detection

The detection consists of the evaporation of SELENOP present in the band separated by isoelectric focusing (IEF) or SDS PAGE using a laser beam followed by the quantification of selenium in the produced aerosol by ICP-MS. This method was first proposed by Fan et al. [120] and later developed for the quantification of selenium proteins by Ballihaut et al. [121,122] and Bianga et al. [123]. The analytical signal resembles a chromatogram (Figure 4).
The identity and purity of the band can be verified by tryptic digestion and ESI MS/MS analysis of the non-ablated part of the gel. Calibration is carried out in a parallel lane using a well-characterized Se-containing protein with a known Se concentration, such as a fully selenized calmoduline [122] or glutathion peroxidase [121].
The LA-ICP-MS detection limits were reported to be 10 times lower for GPx than those of Western blot analyses [124]. However, because LA-ICP-MS is sensitive to selenium and the number of Se atoms in SELENOP is ten times bigger than in GPx, similar detection limits to those of Western blot are expected for SELENOP. Indeed, in well optimized conditions, the reported sensitivity was close to that of radioactivity detection [125]. Note that the advent of triple quadrupole ICP-MS offers a considerable margin for improvement of the detection limits as the most abundant 80Se can be chosen for detection [124]. LA-ICP-MS offers a dynamic range of five orders of magnitude which largely surpasses that of Western blotting detection (two orders of magnitude) and of ELISA (one order of magnitude) which is important for the analysis of unknown sample.

5.4. Isobaric Tagging for Relative and Absolute Quantification (i-TRAQ)

The use of LC-MS/MS as a way to quantify SELENOP was developed with the advent of new techniques such as label-free quantification (LFQ), and tandem mass tag [126].
The iTRAQ (isobaric tagging for relative and absolute quantification) method is based on the covalent labeling of the N-terminus and side chain amines of peptides from protein digestions with tags of varying mass. The samples are then pooled and liquid chromatography tandem mass spectrometry (MS/MS). A database search using the fragmentation data allows for the identification of the labeled peptides and hence the corresponding proteins. The fragmentation of the attached tag generates a low-molecular-mass reporter ion that can be used to relatively quantify the peptides and the proteins from which they originated [127].
To enhance the detection and identification of medium- and low-abundance proteins (such as SELENOP), different immuno-depletion methods are usually used. Since lipids interfere with iTRAQ labeling (as well as detection of peptides by mass spectrometry), the serum samples have to be delipidated before the analysis [80].
SELENOP has been reported in iTRAQ-based multiplex quantitative proteomics investigations searching for biomarkers of disease [80,87,88,89,128,129] or of Se-exposure [130].

5.5. Quality Control and Assurance

As discussed above, several assays for the quantification of human SELENOP have been described. The reported serum concentrations of SELENOP differ considerably between assays, areas and type of diseases, as well as the laboratories. It is unclear whether the reason for this is biological variations or inadequacy of the analytical methodology [47]. Therefore, there is an urgent need for a better understanding of the sources of error in SELENOP analyses.
The SELENOP instability in the sample can be a source of error regardless of the analytical technique used. SELENOP was reported to be stable in serum over prolonged periods of time and upon repeated freezing [68,94] but other researchers found it to decompose quickly and lose selenium [110]. SELENOP proteolysis upon storage and its interactions with abundant or specific plasma proteins may occur [23]. In order to reduce the risk of autolysis, diisopropyl fluorophosphate was recommended to be added to each pooled fraction to avoid the proteolytic cleavage of SELENOP [79]. The question of the stability of semi-purified SELENOP has not been widely discussed but the matrix removal is likely to affect the stability of the protein.
Each of the techniques proposed has its own sources of error. Antibody-based enzyme immunoassays suffer from a difficult-to-control selectivity and high standard deviations. The validation of most commercial assays for SELENOP had been missing until 2015 [72] leading to inconsistencies and poor data comparability. The SELENOP quantification is closely linked to the choice of the kit and the quality of the antibody employed. A recent comparison of the commercially available kits for the determination of SELENOP levels in 21 human serum samples showed that only one out of the three commercial kits tested showed a good correlation with the method developed in-house [98].
In chromatographic methods, the peak assignment is based on the retention hypothesis which assumes the specificity of the separation to SELENOP. The molecular confirmation of the identity of the SELENOP determined (full length, truncated, post-translationally modified) is often lacking. The SELENOP recovery in the separation procedures is seldom reported. However, the traceability for the Se mass balance (100% column recovery), the unambiguous identification of the SELENOP eluted, and the verification of the fraction purity are the sine qua non conditions to assign the accurate value to the SELENOP concentration [84].
On the level of quantification by ICP-MS, calibration by unspecific or semi-specific isotope dilution does not account for any losses or transformations occurring during sample preparation or species separation. The assumption of the identical response of the selenite and Se present in SELENOP may not be true under some conditions. The precision of the isotope ratio measurement is a considerable source of measurement uncertainty at levels close to the detection limits [53] which requires improvements in terms of sensitivity.
The accurate quantification is contingent on the availability of specific certified reference materials (CRMs), pure primary standards and reference methods. Interlaboratory assays have been scarce and limited to a single type approach, e.g., to ELISA [98]. A comparison of Western blotting with ELISA [96] showed that the results from both methods were in agreement and indicated an unchanged pattern of immunoreactive protein isoforms.
A great step towards quality assurance is the increasing number of works reporting the SELENOP concentration values in the CRMs available on the market. The data reported by several authors are summarized in Table 2 which shows a good coherence of the results obtained by ICP-MS approaches. However, no comparison of this data obtained with immunological methods has been available, most of these methods actually use the CRM as calibration standard [59].

6. Imaging

In the absence of imaging studies using mass spectrometry, the imaging of SELENOP in tissues can be carried out using either chemical fluorescent probes targeting free SeCys residues or by immunohistochemistry using SELENOP directed antibodies.
The use of the strong nucleophilic properties of selenols to simulate the cleavage of Se-Se and Se-S bonds is a widely used mechanism for designing the fluorescent probes for the detection of bioselenols validated for thioredoxine reductase. Currently, few selenol specific fluorescent probes are commercially available for medical diagnosis or SELENOP detection, and it is difficult to distinguish various functional selenoproteins by detecting selenol [132].
Antibodies can be used for selective imaging of SELENOP in tissue slices. The methods include: immunoperoxidase staining, immunofluorescence, and immunohistochemical analysis in paraffin-embedded samples. Immunohistochemical localization of SELENOP revealed its presence in liver and brain bound to capillary endothelial cell walls [49].

7. Applications and Reference Values

Table 3 summarizes the results of clinical studies in a variety of areas reporting SELENOP concentration in serum samples of healthy individuals and patients affected by specific diseases, measured by different molecular (immunoassays) or elemental methods (ICP). The variations in the data obtained by different techniques and laboratories are significant. In practice, clinical conclusions can be drawn solely on the basis of data obtained in the same laboratory.
Most of the studies have been limited to serum. A recent study of breast milk from five healthy mothers reported a SELENOP concentration of 20.1 + 1.0 ng/mL (as Se) by HPLC -ICP-MS [83]. An early study of the cerebrospinal fluid of 24 neurologically healthy subjects by HPLC-ICP-MS resulted in a mean concentration of 0.47 ng/mL, a factor of 10 lower than the corresponding concentration in serum [110]. Recently, a study of 75 Parkinson’s disease patients reported a mean value of 1.92 ng SELENOP (as Se) /mL in comparison with 2.02 ng/mL found in the population of 68 control subjects.
The isotopic selectivity of ICP-MS and the fact that selenium has multiple isotopes offers a possibility to use stable isotopic tracers to follow the incorporation of Se coming from different food sources into selenoproteins, including SELENOP. The intravenously injected 82Se-enriched SeMet into mice under different nutritional statuses (Se-adequate and Se-deficient) before the isotope-specific measurements of the expressed selenoproteins were taken, allowed studies to discriminate part of the exogenous 82Se incorporated into SELENOP [113].
Table 3. Overview of SELENOP concentrations in blood sample studies involving several subjects. The values that can be consider as control are highlighted in grey.
Table 3. Overview of SELENOP concentrations in blood sample studies involving several subjects. The values that can be consider as control are highlighted in grey.
Patients’ Characteristics
(Number)
CountrySELENOP Average
(Range), ng Se/mL
Technique Used for QuantificationRef.
Healthy (73)Japan96.9 ± 20.1 *ELISA
(in-house kit)
[70]
Hypercolesterolaemic before treatment (7)104 ± 20.1 *
Hypercolesterolaemic after treatment (7)42.1 ± 23.8 *
Healthy (5)Spain54.8 ± 3.99HPLC-ICP-MS
(post-column IDA)
[101]
Haemodialysis (5)35.2 ± 2.66
Healthy (20)Japan62.2 ± 14.6 *AAS[133]
Ulcerative colitis (34)54.8 ± 18.3 *
Crohn’s Disease with elemental diet (17)32.9 ± 9.14 *25.6 ± 7.32 *
Crohn’s Disease with non-elemental diet (20)38.4 ± 5.49 *
Healthy (318)Germany98.4 ± n.a.ILMA (in-house kit)[94]
Healthy (399)Greece49 ± 15HPLC-ICP-MS
(post-column IDA)
[104]
Healthy (15)Italy56 ± 8HPLC-ICP-MS
(external calibration)
[103]
Type 2 diabetes (40)58 ± 9
Healthy (20)Korea6.62 (4.62–12.7) ± n.a. *ELISA kit USCN Life Science[97]
Type 2 diabete (40)18.9 (9.07–39.3) ± n.a. *
Prediabete (40)15.9 (9.44–28.9) ± n.a. *
Neurologically healthy (24)Germany1.55–50.6 ± 0.03HPLC-ICP-MS
(external calibration)
[110]
Control (966)Europe78.6 (53–112) ± 16.9 *ILMA SelenotestTM, ICI
GmbH
[38]
Patient with colon cancer (598)75 (49.4–110) ± 16.9 *
Patient with rectal cancer (368)76.8 (53–110) ± 16.9 *
Healthy mother (83)Spain42,49 ± 9.49 (ICP-MS)HPLC-ICP-MS
(post-column IDA)
Elisa kit USCN Business Co
[107]
6.99 ± 2.26 (ELISA) *
Healthy baby (83)28.06 ± 7.69 (ICP-MS)
0.35 ± 0.18 (ELISA) *
Healthy (29)China265 ± 234 *ELISA kit USCN Life Science[95]
Overweight/obese individuals (34)957 ± 715 *
Healthy (76)Japan45.9 ± 9.51 *Sol particle homogeneous immunoassay (SPIA)[66]
Occupationally non-exposed (50)Germany31.1–59.2 ± (2.18–4.14)HPLC-ICP-MS
(external calibration)
[68]
after coronary angiography (controls) (20)Japan44.4 ± 4.94 *sol particle homogeneous immunoassay (SPIA)[27]
pulmonary arterial hypertension patients (65)56.1 ± 10.4 *
Control (around 2000)Sweden80.5 ± n.a. *ELISA Kit selenOtestTM, SelenOmed GmbH
(validated by Western blot)
[96]
Patient before selenium treatment (55)62.2 ± n.a. *
Patient treated with 0.5 mg selenite/m²73.2–128 ± n.a. *
Patient treated with 1–33.4 mg selenite/m2>183 ± n.a. *
Control group (37)Germany67.7 ± n.a. *ELISA kit Cloud Clone[134]
infarct-related cardiogenic shock day 1 (147)112 ± n.a. *
infarct-related cardiogenic shock day 3 (147)411 ± n.a. *
Healthy (39)Spain76.74 ± 3.72HPLC-ICP-MS (SUID)[105]
Lung cancer (48)82.04 ± 4.41
Control group (966 EPIC study)Germany78.6 (53–112) ± 16.9 *ELISA Kit selenOtestTM, selenOmed GmbH[135]
Liver transplanted patient alived (63)37.9 (11.7–85.2) ± 12.8 *
Liver transplanted patient deceased (16)36.2 (18.5–60.7) ± 11 *
Controls group (1160)Denmark101 (64–146) ± n.a. *CE-certified SELENOP-ELISA[136]
Advanced prostate cancer patient (1160)98.8 (62.2–146) ± n.a. *
High-grade prostate cancer patient (1160)101 (65.8–146) ± n.a. *
Advanced-stage prostate cancer patient (281)98.8 (58.5–148) ± n.a. *
Type 2 diabetes patients (176)China33.2 ± 8.93 *ELISA kit Cloud Clone[42]
Healthy mother (20)Spain57.1 ± 8.7 (ICP)HPLC-ICP-MS (SUID)
SELENOP-ELISA Kit
[137]
22.1 ± 10.6 (ELISA)
Healthy baby (20)33.6 ± 4.2 (ICP)
11.8 ± 2.8 (ELISA)
* Values have been recalculated to be expressed as concentration of Se (ng/mL) in SELENOP, assuming that SELENOP contains 10 atoms of Se in its sequence and its molecular weight of 43,174 g·mol−1. n.a. = non-available.

8. Conclusions

SELENOP holds promise to be a valuable biomarker of selenium status, but its chemical characteristics still need to be investigated and methods for its accurate quantitation improved.
Immunoassays remain the standard for the determination of human and animal health status, because of their speed, simplicity and limited presence of mass spectrometry technology in the clinical environment. The validation of assays has been considerably improving and interlaboratory comparisons undertaken in order to prevent erroneous data and incorrect interpretations. In particular, critical comparisons of data obtained using methods based on a different principle: immunoassays and mass spectrometry are necessary. Before recombinant SELENOP becomes available to be used as a primary standard for isotope dilution quantifications, careful investigation of the characteristics of the SELENOP measured by electrospray MS and strict control of the recoveries at the various steps of the analytical procedures are strongly recommended.
The molecular characterization of SELENOP isolated from different species is required to address the questions of truncated isoforms; those varying in terms of amino-acid composition and sequence, as well as in terms of post-translational modifications require more in-depth studies which would definitely profit from the approaches of top-down proteomics. To date, the results yielded by the classical protein analysis, peptide mapping and microsequencing, remain fundamental to our knowledge about the isoforms. MALDI FT-ICR imaging is indispensable to verify the imaging data obtained by selenol probes and immunostaining of tissue slices.
While most studies into SELENOP’s characterization have been carried out on rats, the exploration of the SELENOP expression in organisms theoretically capable of incorporating dozens of SeCys residues into a SELENOP sequence is a fascinating topic [11].

Author Contributions

Conceptualization, R.L.; writing—original draft preparation, J.L., L.R., J.S.; writing—review and editing, L.R., J.S., R.L.; funding acquisition, L.R. All authors have read and agreed to the published version of the manuscript.

Funding

J.L acknowledges the PhD grant from the Nouvelle Aquitaine Region and the E2S-UPPA.

Institutional Review Board Statement

Not applicable.

Informed Consent Statement

Not applicable.

Data Availability Statement

Not applicable.

Conflicts of Interest

The authors declare no conflict of interest.

Abbreviations

AAamino-acid
AASatomic absorption spectroscopy
Albalbumin
BlueHiTrap blue affinity column
CRMcertified reference material
ELISAenzyme-linked immunosorbent assay
ESIelectrospray ionizarion
FT-ICRfourier-transform ion cyclotron resonance
Glu-Cendoproteinase glu-c = glutamyl endopeptidase
Gpxglutathione peroxidase
HepHiTrap heparin affinity column
Hishistidine
HMWhigh molecular weight
HPLChigh pressure liquid chromatography
ICP-MSinductively coupled plasma- mass spectrometry
IDAisotopic dilution analysis
IEFisoelectric focusing
ILMAimmunoluminometric assay
IMACimmobilized metal ion affinity chromatography
iTRAQisobaric tagging for relative and absolute quantification
LAlaser ablation
LCliquid chromatography
LFQlabel-free quantification
LMWlow molecular weight
MARCmulti-affinity removal column
MALDImatrix-assisted laser desorption/ionization
MSmass spectrometry
NTAnitrilotriacetic acid
PNGaseFpeptide: N-glycosidase F
PVDFpolyvinylidene fluoride
SAXstrong anion-exchange column
SDS-PAGEsodium dodecyl sulphate- polyacrylamide gel-electrophoresis
SECsize-exclusion chromatography
SECISselenocysteine insertion structure
SeCysselenocysteine
SELENOPselenoprotein P
SPIAsol particle homogeneous immunoassay
SUIDspecies-unspecific isotopic dilution analysis

References

  1. Hatfield, D.L.; Schweizer, U.; Tsuji, P.A.; Gladyshev, V.N. (Eds.) Selenium: Its Molecular Biology and Role in Human Health; Springer Science & Business Media: Berlin/Heidelberg, Germany, 2016. [Google Scholar]
  2. Gromer, S.; Eubel, J.K.; Lee, B.L.; Jacob, J. Human selenoproteins at a glance. Cell. Mol. Life Sci. 2005, 62, 2414–2437. [Google Scholar] [CrossRef] [PubMed]
  3. Roman, M.; Jitaru, P.; Barbante, C. Selenium biochemistry and its role for human health. Metallomics 2014, 6, 25–54. [Google Scholar] [CrossRef]
  4. Böck, A.; Forchhammer, K.; Heider, J.; Leinfelder, W.; Sawers, G.; Veprek, B.; Zinoni, F. Selenocysteine: The 21st amino acid. Mol. Microbiol. 1991, 5, 515–520. [Google Scholar] [CrossRef] [PubMed]
  5. Shetty, S.; Copeland, P.R. Molecular mechanism of selenoprotein P synthesis. Biochim. Biophys. Acta Gen. Subj. 2018, 1862, 2506–2510. [Google Scholar] [CrossRef] [PubMed]
  6. Kryukov, G.V.; Castellano, S.; Novoselov, S.V.; Lobanov, A.V.; Zehtab, O.; Guigó, R.; Gladyshev, V.N. Characterization of mammalian selenoproteomes. Science 2003, 300, 1439–1443. [Google Scholar] [CrossRef] [Green Version]
  7. Zhang, Y.; Gladyshev, V.N. An algorithm for identification of bacterial selenocysteine insertion sequence elements and selenoprotein genes. Bioinformatics 2005, 21, 2580–2589. [Google Scholar] [CrossRef] [PubMed]
  8. Santesmasses, D.; Mariotti, M.; Gladyshev, V.N. Bioinformatics of selenoproteins. Antioxid. Redox Signal. 2020, 33, 525–536. [Google Scholar] [CrossRef]
  9. Zhang, Y.; Zheng, J. Bioinformatics of metalloproteins and metalloproteomes. Molecular 2020, 25, 3366. [Google Scholar] [CrossRef] [PubMed]
  10. Labunskyy, V.; Hatfield, D.L.; Gladyshev, V.N. Selenoproteins: Molecular pathways and physiological roles. Physiol. Rev. 2014, 94, 739–777. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  11. Baclaocos, J.; Santesmasses, D.; Mariotti, M.; Bierła, K.; Vetick, M.B.; Lynch, S.; McAllen, R.; Mackrill, J.J.; Loughran, G.; Guigó, R.; et al. Processive recoding and metazoan evolution of selenoprotein P: Up to UGAs in molluscs. J. Mol. Biol. 2019, 431, 4381–4407. [Google Scholar] [CrossRef] [PubMed]
  12. Baclaocos, J.; Mackrill, J.J. Why Multiples of 21? Why does Selenoprotein P Contain Multiple Selenocysteine Residues? Curr. Nutraceuticals 2020, 1, 42–53. [Google Scholar] [CrossRef]
  13. Jiang, L.; Liu, Q. SelGenAmic: An algorithm for selenoprotein gene assembly. Adv. Struct. Saf. Stud. 2017, 1661, 29–39. [Google Scholar] [CrossRef]
  14. Lobanov, A.V.; Hatfield, D.L.; Gladyshev, V.N. Reduced reliance on the trace element selenium during evolution of mammals. Genome Biol. 2008, 9, 1–11. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  15. Burk, R.F. Effect of dietary selenium level on 75se binding to rat plasma proteins. Exp. Biol. Med. 1973, 143, 719–722. [Google Scholar] [CrossRef]
  16. Rotruck, J.T.; Pope, A.L.; Ganther, H.E.; Swanson, A.B.; Hafeman, D.G.; Hoekstra, W.G. Selenium: Biochemical role as a component of glutathione peroxidase. Science 1973, 179, 588–590. [Google Scholar] [CrossRef]
  17. McConnell, K.P.; Burton, R.M.; Kute, T.; Higgins, P.J. Selenoproteins from rat testis cytosol. Biochim. Biophys. Acta Gen. Subj. 1979, 588, 113–119. [Google Scholar] [CrossRef]
  18. Motsenbocker, M.A.; Tappel, A.L. A selenocysteine-containing selenium-transport protein in rat plasma. Biochim. Biophys. Acta Gen. Subj. 1982, 719, 147–153. [Google Scholar] [CrossRef]
  19. Persson-Moschos, M.; Huang, W.; Srikumar, T.S.; Åkesson, B.; Lindeberg, S. Selenoprotein P in serum as a biochemical marker of selenium status. Analyst 1995, 120, 833–836. [Google Scholar] [CrossRef]
  20. Gladyshev, V.N.; Arnér, E.; Berry, M.J.; Brigelius-Flohé, R.; Bruford, E.; Burk, R.F.; Carlson, B.A.; Castellano, S.; Chavatte, L.; Conrad, M.; et al. Selenoprotein gene nomenclature. J. Biol. Chem. 2016, 291, 24036–24040. [Google Scholar] [CrossRef] [Green Version]
  21. Burk, R.F.; Hill, K.E. Selenoprotein P—Expression, functions, and roles in mammals. Biochim. Biophys. Acta Gen. Subj. 2009, 1790, 1441–1447. [Google Scholar] [CrossRef] [Green Version]
  22. Combs, G.F., Jr. Biomarkers of selenium status. Nutrients 2015, 7, 2209–2236. [Google Scholar] [CrossRef] [Green Version]
  23. Michaelis, M.; Gralla, O.; Behrends, T.; Scharpf, M.; Endermann, T.; Rijntjes, E.; Pietschmann, N.; Hollenbach, B.; Schomburg, L. Selenoprotein P in seminal fluid is a novel biomarker of sperm quality. Biochem. Biophys. Res. Commun. 2014, 443, 905–910. [Google Scholar] [CrossRef] [PubMed]
  24. Xia, Y.E.; Hill, K.; Li, P.; Xu, J.; Zhou, D.; Motley, A.K.; Wang, L.; Byrne, D.W.; Burk, R.F. Optimization of selenoprotein P and other plasma selenium biomarkers for the assessment of the selenium nutritional requirement: A placebo-controlled, double-blind study of selenomethionine supplementation in selenium-deficient Chinese subjects. Am. J. Clin. Nutr. 2010, 92, 525–531. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  25. Hoeflich, J.; Hollenbach, B.; Behrends, T.; Hoeg, A.; Stosnach, H.; Schomburg, L. The choice of biomarkers determines the selenium status in young German vegans and vegetarians. Br. J. Nutr. 2010, 104, 1601–1604. [Google Scholar] [CrossRef] [PubMed]
  26. Hurst, R.; Armah, C.N.; Dainty, J.R.; Hart, D.J.; Teucher, B.; Goldson, A.J.; Broadley, M.R.; Motley, A.K.; Fairweather-Tait, S.J. Establishing optimal selenium status: Results of a randomized, double-blind, placebo-controlled trial. Am. J. Clin. Nutr. 2010, 91, 923–931. [Google Scholar] [CrossRef] [Green Version]
  27. Kikuchi, N.; Satoh, K.; Satoh, T.; Yaoita, N.; Siddique, M.A.H.; Omura, J.; Kurosawa, R.; Nogi, M.; Sunamura, S.; Miyata, S.; et al. Diagnostic and prognostic significance of serum levels of SeP (Selenoprotein P) in patients with pulmonary hypertension. Arterioscler. Thromb. Vasc. Biol. 2019, 39, 2553–2562. [Google Scholar] [CrossRef]
  28. Vu, D.L.; Saurav, K.; Mylenko, M.; Ranglová, K.; Kuta, J.; Ewe, D.; Masojídek, J.; Hrouzek, P. In vitro bioaccessibility of selenoamino acids from selenium (Se)-enriched Chlorella vulgaris biomass in comparison to selenized yeast; a Se-enriched food supplement; and Se-rich foods. Food Chem. 2019, 279, 12–19. [Google Scholar] [CrossRef]
  29. Heller, R.A.; Sun, Q.; Hackler, J.; Seelig, J.; Seibert, L.; Cherkezov, A.; Minich, W.B.; Seemann, P.; Diegmann, J.; Pilz, M.; et al. Prediction of survival odds in COVID-by zinc, age and selenoprotein P as composite biomarker. Redox Biol. 2021, 38, 101764. [Google Scholar] [CrossRef]
  30. Moghaddam, A.; Heller, R.A.; Sun, Q.; Seelig, J.; Cherkezov, A.; Seibert, L.; Hackler, J.; Seemann, P.; Diegmann, J.; Pilz, M.; et al. Selenium deficiency is associated with mortality risk from COVID-19. Nutrition 2020, 12, 2098. [Google Scholar] [CrossRef]
  31. Reeves, M.A.; Hoffmann, P.R. The human selenoproteome: Recent insights into functions and regulation. Cell. Mol. Life Sci. 2009, 66, 2457–2478. [Google Scholar] [CrossRef] [Green Version]
  32. Burk, R.F.; Hill, K.E.; Read, R.; Bellew, T. Response of rat selenoprotein P to selenium administration and fate of its selenium. Am. J. Physiol. Metab. 1991, 261, E26–E30. [Google Scholar] [CrossRef]
  33. Eckers, J.C.; Kalen, A.L.; Xiao, W.; Sarsour, E.H.; Goswami, P.C. Selenoprotein p inhibits radiation-induced late reactive oxygen species accumulation and normal cell injury. Int. J. Radiat. Oncol. 2013, 87, 619–625. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  34. Temur, M.; Taşgöz, F.N.; Ertürk, N.K. Elevated circulating Selenoprotein P levels in patients with polycystic ovary syndrome. J. Obstet. Gynaecol. 2021, 2021, 1–5. [Google Scholar] [CrossRef]
  35. Fujii, M.; Saijoh, K.; Sumino, K. Regulation of selenoprotein P mRNA expression in comparison with metallothionein and osteonectin mRNAs following cadmium and dexamethasone administration. Kobe J. Med Sci. 1997, 43, 13–23. [Google Scholar]
  36. Yoneda, S.; Suzuki, K.T. Equimolar Hg-Se complex binds to Selenoprotein P. Biochem. Biophys. Res. Commun. 1997, 231, 7–11. [Google Scholar] [CrossRef] [PubMed]
  37. Barrett, C.W.; Reddy, V.K.; Short, S.; Motley, A.K.; Lintel, M.K.; Bradley, A.M.; Freeman, T.; Vallance, J.; Ning, W.; Parang, B.; et al. Selenoprotein P influences colitis-induced tumorigenesis by mediating stemness and oxidative damage. J. Clin. Investig. 2015, 125, 2646–2660. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  38. Hughes, D.J.; Fedirko, V.; Jenab, M.; Schomburg, L.; Méplan, C.; Freisling, H.; Bueno-De-Mesquita, H.; Hybsier, S.; Becker, N.-P.; Czuban, M.; et al. Selenium status is associated with colorectal cancer risk in the European prospective investigation of cancer and nutrition cohort. Int. J. Cancer 2014, 136, 1149–1161. [Google Scholar] [CrossRef]
  39. Köhrle, J. Selenium in endocrinology—Selenoprotein-related diseases, population studies, and epidemiological evidence. Endocrinology 2021, 162. [Google Scholar] [CrossRef]
  40. Takata, Y.; Xiang, Y.-B.; Burk, R.F.; Li, H.; E Hill, K.; Cai, H.; Gao, J.; Zheng, W.; Shu, X.-O.; Cai, Q. Plasma selenoprotein P concentration and lung cancer risk: Results from a case-control study nested within the Shanghai men’s health study. Carcinogenesis 2018, 39, 1352–1358. [Google Scholar] [CrossRef]
  41. Rayman, M.P. Selenium and human health. Lancet 2012, 379, 1256–1268. [Google Scholar] [CrossRef]
  42. Xi, J.; Zhang, Q.; Wang, J.; Guo, R.; Wang, L. Factors influencing selenium concentration in community-dwelling patients with type diabetes mellitus. Biol. Trace Elem. Res. 2020, 199, 1–7. [Google Scholar] [CrossRef]
  43. Zhang, Z.-H.; Song, G.-L. Roles of selenoproteins in brain function and the potential mechanism of selenium in alzheimer’s disease. Front. Neurosci. 2021, 15, 215. [Google Scholar] [CrossRef]
  44. Misu, H.; Takamura, T.; Takayama, H.; Hayashi, H.; Nagata, N.; Kurita, S.; Ishikura, K.; Ando, H.; Takeshita, Y.; Ota, T.; et al. A liver-derived secretory protein, Selenoprotein P, causes insulin resistance. Cell Metab. 2010, 12, 483–495. [Google Scholar] [CrossRef] [Green Version]
  45. Saito, Y. Selenoprotein P as a significant regulator of pancreatic β cell function. J. Biochem. 2019, 167, 119–124. [Google Scholar] [CrossRef]
  46. Huang, Y.-C.; Wu, T.-L.; Zeng, H.; Cheng, W.-H. Dietary selenium requirement for the prevention of glucose intolerance and insulin resistance in middle-aged mice. J. Nutr. 2021. [Google Scholar] [CrossRef]
  47. Tsutsumi, R.; Saito, Y. Selenoprotein P: P for plasma, prognosis, prophylaxis, and more. Biol. Pharm. Bull. 2020, 43, 366–374. [Google Scholar] [CrossRef] [Green Version]
  48. Cardoso, B.R.; Ganio, K.; Roberts, B.R. Expanding beyond ICP-MS to better understand selenium biochemistry. Metallomics 2019, 11, 1974–1983. [Google Scholar] [CrossRef]
  49. Tujebajeva, R.M.; Copeland, P.R.; Xu, X.; Carlson, B.A.; Harney, J.W.; Driscoll, D.M.; Hatfield, D.L.; Berry, M.J. Decoding apparatus for eukaryotic selenocysteine insertion. EMBO Rep. 2000, 1, 158–163. [Google Scholar] [CrossRef] [Green Version]
  50. Hill, K.; Lloyd, R.; Yang, J.; Read, R.; Burk, R. The cDNA for rat selenoprotein P contains TGA codons in the open reading frame. J. Biol. Chem. 1991, 266, 10050–10053. [Google Scholar] [CrossRef]
  51. Burk, R.F.; Hill, K.E. Some properties of selenoprotein P. Biol. Trace Elem. Res. 1992, 33, 151–153. [Google Scholar] [CrossRef]
  52. Tanaka, M.; Saito, Y.; Misu, H.; Kato, S.; Kita, Y.; Takeshita, Y.; Kanamori, T.; Nagano, T.; Nakagen, M.; Urabe, T.; et al. Development of a Sol particle homogeneous immunoassay for measuring full-length Selenoprotein P in human serum. J. Clin. Lab. Anal. 2014, 30, 114–122. [Google Scholar] [CrossRef]
  53. Ward-Deitrich, C.; Cuello-Nuñez, S.; Kmiotek, D.; Torma, F.A.; Busto, M.D.C.; Fisicaro, P.; Goenaga-Infante, H. Accurate quantification of Selenoprotein P (SEPP1) in plasma using isotopically enriched seleno-peptides and species-specific isotope dilution with HPLC coupled to ICP-MS/MS. Anal. Chem. 2016, 88, 6357–6365. [Google Scholar] [CrossRef]
  54. Saito, Y.; Sato, N.; Hirashima, M.; Takebe, G.; Nagasawa, S.; Takahashi, K. Domain structure of bi-functional selenoprotein P. Biochem. J. 2004, 381, 841–846. [Google Scholar] [CrossRef] [Green Version]
  55. Turanov, A.A.; Everley, R.A.; Hybsier, S.; Renko, K.; Schomburg, L.; Gygi, S.P.; Hatfield, D.L.; Gladyshev, V.N. Regulation of selenocysteine content of human Selenoprotein P by dietary selenium and insertion of cysteine in place of selenocysteine. PLoS ONE 2015, 10, e0140353. [Google Scholar] [CrossRef] [Green Version]
  56. Ma, S.; Hill, K.E.; Caprioli, R.M.; Burk, R.F. Mass spectrometric characterization of full-length rat selenoprotein P and three isoforms shortened at the C terminus. Evidence that three UGA codons in the mRNA open reading frame have alternative functions of specifying selenocysteine insertion or translation termination. J. Biol. Chem. 2002, 277, 12749–12754. [Google Scholar]
  57. Méplan, C.; Nicol, F.; Burtle, B.T.; Crosley, L.K.; Arthur, J.R.; Mathers, J.C.; Hesketh, J.E. Relative abundance of Selenoprotein P isoforms in human plasma depends on genotype, se intake, and cancer status. Antioxid. Redox Signal. 2009, 11, 2631–2640. [Google Scholar] [CrossRef]
  58. Åkesson, B.; Bellew, T.; Burk, R.F. Purification of selenoprotein P from human plasma. Biochim. Biophys. Acta Protein Struct. Mol. Enzym. 1994, 1204, 243–249. [Google Scholar] [CrossRef]
  59. Hybsier, S.; Schulz, T.; Wu, Z.; Demuth, I.; Minich, W.B.; Renko, K.; Rijntjes, E.; Köhrle, J.; Strasburger, C.J.; Steinhagen-Thiessen, E.; et al. Sex-specific and inter-individual differences in biomarkers of selenium status identified by a calibrated ELISA for selenoprotein P. Redox Biol. 2017, 11, 403–414. [Google Scholar] [CrossRef]
  60. Ma, S.; Hill, K.E.; Burk, R.F.; Caprioli, R.M. Mass spectrometric identification of N-and O-glycosylation sites of full-length rat Selenoprotein P and determination of selenide−sulfide and disulfide linkages in the shortest isoform. Biochemistry 2003, 42, 9703–9711. [Google Scholar] [CrossRef]
  61. Mostert, V.; Lombeck, I.; Abel, J. A novel method for the purification of selenoprotein P from human plasma. Arch. Biochem. Biophys. 1998, 357, 326–330. [Google Scholar] [CrossRef]
  62. Steinbrenner, H.; Alili, L.; Stuhlmann, D.; Sies, H.; Brenneisen, P. Post-translational processing of selenoprotein P: Implications of glycosylation for its utilisation by target cells. Biol. Chem. 2007, 388, 1043–1051. [Google Scholar] [CrossRef]
  63. Yang, J.-G.; Morrison-Plummer, J.; Burk, R.F. Purification and quantitationof a rat plasma selenoprotein distinct from glutathione peroxidase usingmonoclonal antibodies. J. Biol. Chem. 1987, 262, 13372–13375. [Google Scholar] [CrossRef]
  64. Himeno, S.; Chittum, H.S.; Burk, R.F. Isoforms of selenoprotein P in rat plasma. Evidence for a full-length form and another form that terminates at the second UGA in the open reading frame. J. Biol. Chem. 1996, 271, 15769–15775. [Google Scholar] [CrossRef] [Green Version]
  65. Ballihaut, G.; Kilpatrick, L.E.; Kilpatrick, E.L.; Davis, W.C. Multiple forms of selenoprotein P in a candidate human plasma standard reference material. Metallomics 2012, 4, 533–538. [Google Scholar] [CrossRef]
  66. Oo, S.M.; Misu, H.; Saito, Y.; Tanaka, M.; Kato, S.; Kita, Y.; Takayama, H.; Takeshita, Y.; Kanamori, T.; Nagano, T.; et al. Serum selenoprotein P, but not selenium, predicts future hyperglycemia in a general Japanese population. Sci. Rep. 2018, 8, 1–10. [Google Scholar] [CrossRef]
  67. Hondal, R.J.; Ma, S.; Caprioli, R.M.; Hill, K.E.; Burk, R.F. Heparin-binding histidine and lysine residues of rat selenoprotein P. J. Biol. Chem. 2001, 276, 15823–15831. [Google Scholar] [CrossRef] [Green Version]
  68. Heitland, P.; Köster, H.D. Biomonitoring of selenoprotein P in human serum by fast affinity chromatography coupled to ICP-MS. Int. J. Hyg. Environ. Health 2018, 221, 564–568. [Google Scholar] [CrossRef]
  69. Sidenius, U.; Farver, O.; Jøns, O.; Gammelgaard, B. Comparison of different transition metal ions for immobilized metal affinity chromatography of selenoprotein P from human plasma. J. Chromatogr. B Biomed. Sci. Appl. 1999, 735, 85–91. [Google Scholar] [CrossRef]
  70. Saito, Y.; Watanabe, Y.; Saito, E.; Honjoh, T.; Takahashi, K. Production and application of monoclonal antibodies to human selenoprotein P. J. Health Sci. 2001, 47, 346–352. [Google Scholar] [CrossRef] [Green Version]
  71. Olson, G.E.; Winfrey, V.P.; NagDas, S.K.; Hill, K.E.; Burk, R.F. Apolipoprotein E receptor-(ApoER2) mediates selenium uptake from selenoprotein P by the mouse testis. J. Biol. Chem. 2007, 282, 12290–12297. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  72. Hybsier, S.; Wu, Z.; Schulz, T.; Strasburger, C.; Köhrle, J.; Minich, W.; Schomburg, L. Establishment and characterization of a new ELISA for selenoprotein P. Perspect. Sci. 2015, 3, 23–24. [Google Scholar] [CrossRef] [Green Version]
  73. Altinova, A.E.; Iyidir, O.T.; Ozkan, C.; Ors, D.; Öztürk, M.; Gulbahar, O.; Bozkurt, N.; Törüner, F.B.; Akturk, M.; Cakir, N.; et al. Selenoprotein P is not elevated in gestational diabetes mellitus. Gynecol. Endocrinol. 2015, 31, 874–876. [Google Scholar] [CrossRef]
  74. Baran, A.; Nowowiejska, J.; Krahel, J.A.; Kaminski, T.W.; Maciaszek, M.; Flisiak, I. Higher serum selenoprotein P Level as a novel inductor of metabolic complications in psoriasis. Int. J. Mol. Sci. 2020, 21, 4594. [Google Scholar] [CrossRef] [PubMed]
  75. Wang, Y.; Zou, Y.; Wang, T.; Han, S.; Liu, X.; Zhang, Y.; Su, S.; Zhou, H.; Zhang, X.; Liang, H. A spatial study on serum selenoprotein P and Keshan disease in Heilongjiang Province, China. J. Trace Elem. Med. Biol. 2021, 65, 126728. [Google Scholar] [CrossRef] [PubMed]
  76. Suzuki, K.T.; Sasakura, C.; Yoneda, S. Binding sites for the (Hg-Se) complex on selenoprotein P. Biochim. Biophys. Acta Protein Struct. Mol. Enzym. 1998, 1429, 102–112. [Google Scholar] [CrossRef]
  77. Suzuki, Y.; Sakai, T.; Furuta, N. Isolation of selenoprotein-P and determination of Se concentration incorporated in proteins in human and mouse plasma by tandem heparin affinity and size-exclusion column HPLC-ICPMS. Anal. Sci. 2012, 28, 221. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  78. Deagen, J.; Butler, J.; Zachara, B.; Whanger, P. Determination of the distribution of selenium between glutathione peroxidase, selenoprotein P, and albumin in plasma. Anal. Biochem. 1993, 208, 176–181. [Google Scholar] [CrossRef]
  79. Saito, Y.; Hayashi, T.; Tanaka, A.; Watanabe, Y.; Suzuki, M.; Saito, E.; Takahashi, K. Selenoprotein P in human plasma as an extracellular phospholipid hydroperoxide glutathione peroxidase. Isolation and enzymatic characterization of human selenoprotein p. J. Biol. Chem. 1999, 274, 2866–2871. [Google Scholar] [CrossRef] [Green Version]
  80. Jing, L.; Parker, C.E.; Seo, D.; Hines, M.W.; Dicheva, N.; Yu, Y.; Schwinn, D.; Ginsburg, G.S.; Chen, X. Discovery of biomarker candidates for coronary artery disease from an APOE-knock out mouse model using iTRAQ-based multiplex quantitative proteomics. Proteomics 2011, 11, 2763–2776. [Google Scholar] [CrossRef] [PubMed]
  81. Smith, L.M.; Kelleher, N.L. Proteoforms as the next proteomics currency. Science 2018, 359, 1106–1107. [Google Scholar] [CrossRef]
  82. Ma, S.; Hill, K.E.; Burk, R.F.; Caprioli, R.M. Mass spectrometric determination of selenenylsulfide linkages in rat selenoprotein P. J. Mass Spectrom. 2005, 40, 400–404. [Google Scholar] [CrossRef]
  83. Arias-Borrego, A.; Callejón-Leblic, M.B.; Rodríguez-Moro, G.; Velasco, I.; Gómez-Ariza, J.; García-Barrera, T. A novel HPLC column switching method coupled to ICP-MS/QTOF for the first determination of selenoprotein P (SELENOP) in human breast milk. Food Chem. 2020, 321, 126692. [Google Scholar] [CrossRef]
  84. Ballihaut, G.; Kilpatrick, L.E.; Davis, W.C. Detection, identification, and quantification of selenoproteins in a candidate human plasma standard reference material. Anal. Chem. 2011, 83, 8667–8674. [Google Scholar] [CrossRef] [PubMed]
  85. Bruderer, R.; Muntel, J.; Müller, S.; Bernhardt, O.M.; Gandhi, T.; Cominetti, O.; Macron, C.; Carayol, J.; Rinner, O.; Astrup, A.; et al. Analysis of plasma samples by capillary-flow data-independent acquisition profiles proteomics of weight loss and maintenance. Mol. Cell. Proteom. 2019, 18, 1242–1254. [Google Scholar] [CrossRef] [Green Version]
  86. Wang, X.; Yu, Z.; Zhao, X.; Han, R.; Huang, D.; Yang, Y.; Cheng, G. Comparative proteomic characterization of bovine milk containing β-casein variants A1Aand A2A, and their heterozygote A1A2. J. Sci. Food Agric. 2020, 101, 718–725. [Google Scholar] [CrossRef]
  87. Cole, R.N.; Ruczinski, I.; Schulze, K.; Christian, P.; Herbrich, S.; Wu, L.; Devine, L.R.; O’Meally, R.N.; Shrestha, S.; Boronina, T.N.; et al. The plasma proteome identifies expected and novel proteins correlated with micronutrient status in undernourished Nepalese children. J. Nutr. 2013, 143, 1540–1548. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  88. Shen, X.; Huo, B.; Wu, T.; Song, C.; Chi, Y. iTRAQ-based proteomic analysis to identify molecular mechanisms of the selenium deficiency response in the Przewalski’s gazelle. J. Proteom. 2019, 203, 103389. [Google Scholar] [CrossRef] [PubMed]
  89. Yan, B.; Chen, B.; Min, S.; Gao, Y.; Zhang, Y.; Xu, P.; Li, C.; Chen, J.; Luo, G.; Liu, C. iTRAQ-based comparative serum proteomic analysis of prostate cancer patients with or without bone metastasis. J. Cancer 2019, 10, 4165–4177. [Google Scholar] [CrossRef] [Green Version]
  90. Ouerdane, L.; Gil-Casal, S.; Lobinski, R.; Szpunar, J. Purification of selenoprotein P from human blood using IMAC-Co and heparin columns followed by its characterization by LC ICP-MS and LC ESI-LTQ Orbitrap MS. In Proceedings of the Winter Conference on Plasma Spectrochemistry, Zaragoza, Spain, 30 January–4 February 2011. [Google Scholar]
  91. Lamarche, J.; Bierla, K.; Lobinski, R. Unpublished data. 2021. [Google Scholar]
  92. Hill, K.E.; Xia, Y.; Åkesson, B.; Boeglin, M.E.; Burk, R.F. Selenoprotein P concentration in plasma is an index of selenium status in selenium-deficient and selenium-supplemented chinese subjects. J. Nutr. 1996, 126, 138–145. [Google Scholar] [CrossRef] [Green Version]
  93. Read, R.; Bellew, T.; Yang, J.G.; E Hill, K.; Palmer, I.S.; Burk, R.F. Selenium and amino acid composition of selenoprotein P, the major selenoprotein in rat serum. J. Biol. Chem. 1990, 265, 17899–17905. [Google Scholar] [CrossRef]
  94. Hollenbach, B.; Morgenthaler, N.G.; Struck, J.; Alonso, C.; Bergmann, A.; Köhrle, J.; Schomburg, L. New assay for the measurement of selenoprotein P as a sepsis biomarker from serum. J. Trace Elem. Med. Biol. 2008, 22, 24–32. [Google Scholar] [CrossRef]
  95. Chen, M.; Liu, B.; Wilkinson, D.; Hutchison, A.T.; Thompson, C.H.; Wittert, G.; Heilbronn, L.K. Selenoprotein P is elevated in individuals with obesity, but is not independently associated with insulin resistance. Obes. Res. Clin. Pract. 2017, 11, 227–232. [Google Scholar] [CrossRef]
  96. Brodin, O.; Hackler, J.; Misra, S.; Wendt, S.; Sun, Q.; Laaf, E.; Stoppe, C.; Björnstedt, M.; Schomburg, L. Selenoprotein P as biomarker of selenium status in clinical trials with therapeutic dosages of selenite. Nutrients 2020, 12, 1067. [Google Scholar] [CrossRef] [Green Version]
  97. Yang, S.J.; Hwang, S.Y.; Choi, H.Y.; Yoo, H.J.; Seo, J.A.; Kim, S.G.; Kim, N.H.; Baik, S.H.; Choi, D.S.; Choi, K.M. Serum selenoprotein P levels in patients with type diabetes and prediabetes: Implications for insulin resistance, inflammation, and atherosclerosis. J. Clin. Endocrinol. Metab. 2011, 96, E1325–E1329. [Google Scholar] [CrossRef]
  98. Saito, Y.; Misu, H.; Takayama, H.; Takashima, S.-I.; Usui, S.; Takamura, M.; Kaneko, S.; Takamura, T.; Noguchi, N. Comparison of human selenoprotein P determinants in serum between our original methods and commercially available kits. Biol. Pharm. Bull. 2018, 41, 828–832. [Google Scholar] [CrossRef] [Green Version]
  99. Shigeta, K.; Sato, K.; Furuta, N. Determination of selenoprotein P in submicrolitre samples of human plasma using micro-affinity chromatography coupled with low flow ICP-MS. J. Anal. At. Spectrom. 2007, 22, 911–916. [Google Scholar] [CrossRef]
  100. Busto del Castillo, M.E.; Oster, C.; Cuello-Nuñez, S.; Deitrich, C.L.; Raab, A.; Konopka, A.; Lehmann, W.D.; Goenaga-Infante, H.; Fisicaro, P. Accurate quantification of selenoproteins in human plasma/serum by isotope dilution ICP-MS: Focus on selenoprotein P. J. Anal. At. Spectrom. 2016, 31, 1904–1912. [Google Scholar] [CrossRef] [Green Version]
  101. Hinojosa Reyes, L.; Marchante-Gayón, J.M.; García Alonso, J.I.; Sanz-Medel, A. Quantitative speciation of selenium in human serum by affinity chromatography coupled to post-column isotope dilution analysis ICP-MS. J. Anal. At. Spectrom. 2003, 18, 1210–1216. [Google Scholar] [CrossRef]
  102. Jitaru, P.; Prete, M.; Cozzi, G.; Turetta, C.; Cairns, W.; Seraglia, R.; Traldi, P.; Cescon, P.; Barbante, C. Speciation analysis of selenoproteins in human serum by solid-phase extraction and affinity HPLC hyphenated to ICP-quadrupole MS. J. Anal. At. Spectrom. 2008, 23, 402–406. [Google Scholar] [CrossRef]
  103. Roman, M.; Lapolla, A.; Jitaru, P.; Sechi, A.; Cosma, C.; Cozzi, G.; Cescon, P.; Barbante, C. Plasma selenoproteins concentrations in type diabetes mellitus—A pilot study. Transl. Res. 2010, 156, 242–250. [Google Scholar] [CrossRef]
  104. Letsiou, S.; Lu, Y.; Nomikos, T.; Antonopoulou, S.; Panagiotakos, D.; Pitsavos, C.; Stefanadis, C.; Pergantis, S.A. High-throughput quantification of selenium in individual serum proteins from a healthy human population using HPLC on-line with isotope dilution inductively coupled plasma-MS. Proteomics 2010, 10, 3447–3457. [Google Scholar] [CrossRef]
  105. Callejón-Leblic, M.B.; Rodríguez-Moro, G.; Arias-Borrego, A.; Pereira-Vega, A.; Gómez-Ariza, J.L.; García-Barrera, T. Absolute quantification of selenoproteins and selenometabolites in lung cancer human serum by column switching coupled to triple quadrupole inductively coupled plasma mass spectrometry. J. Chromatogr. A 2020, 1619, 460919. [Google Scholar] [CrossRef]
  106. García-Sevillano, M.A.; García-Barrera, T.; Gómez-Ariza, J.L. Simultaneous speciation of selenoproteins and selenometabolites in plasma and serum by dual size exclusion-affinity chromatography with online isotope dilution inductively coupled plasma mass spectrometry. Anal. Bioanal. Chem. 2014, 406, 2719–2725. [Google Scholar] [CrossRef]
  107. Santos, C.; García-Fuentes, E.; Callejón-Leblic, M.B.; García-Barrera, T.; Gómez-Ariza, J.L.; Rayman, M.P.; Velasco, I. Selenium, selenoproteins and selenometabolites in mothers and babies at the time of birth. Br. J. Nutr. 2017, 117, 1304–1311. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  108. Palacios, O.; Ruiz Encinar, J.; Schaumlöffel, D.; Lobinski, R. Fractionation of selenium-containing proteins in serum by multiaffinity liquid chromatography before size-exclusion chromatography-ICPMS. Anal. Bioanal. Chem. 2006, 384, 1276–1283. [Google Scholar] [CrossRef]
  109. Maass, F.; Michalke, B.; Willkommen, D.; Schulte, C.; Tönges, L.; Boerger, M.; Zerr, I.; Bähr, M.; Lingor, P. Selenium speciation analysis in the cerebrospinal fluid of patients with Parkinson’s disease. J. Trace Elem. Med. Biol. 2020, 57, 126412. [Google Scholar] [CrossRef]
  110. Solovyev, N.; Berthele, A.; Michalke, B. Selenium speciation in paired serum and cerebrospinal fluid samples. Anal. Bioanal. Chem. 2013, 405, 1875–1884. [Google Scholar] [CrossRef]
  111. Xu, M.; Yang, L.; Wang, Q. Quantification of selenium-tagged proteins in human plasma using species-unspecific isotope dilution ICP-DRC-qMS coupled on-line with anion exchange chromatography. J. Anal. At. Spectrom. 2008, 23, 1545–1549. [Google Scholar] [CrossRef] [Green Version]
  112. Anan, Y.; Ogra, Y. Toxicological and pharmacological analysis of selenohomolanthionine in mice. Toxicol. Res. 2013, 2, 115–122. [Google Scholar] [CrossRef]
  113. Suzuki, Y.; Hashiura, Y.; Sakai, T.; Yamamoto, T.; Matsukawa, T.; Shinohara, A.; Furuta, N. Selenium metabolism and excretion in mice after injection of 82Se-enriched selenomethionine. Metallomics 2013, 5, 445–452. [Google Scholar] [CrossRef]
  114. Tanner, S.D.; Baranov, V.I.; Bandura, D.R. Reaction cells and collision cells for ICP-MS: A tutorial review. Spectrochim. Acta Part B At. Spectrosc. 2002, 57, 1361. [Google Scholar] [CrossRef]
  115. Encinar, J.R.; Schaumlöffel, D.; Ogra, Y.; Lobinski, R. Determination of selenomethionine and selenocysteine in human serum using speciated isotope dilution-capillary HPLC-inductively coupled plasma collision cell mass spectrometry. Anal. Chem. 2004, 76, 6635–6642. [Google Scholar] [CrossRef]
  116. Jitaru, P.; Goenaga-Infante, H.; Vaslin-Reimann, S.; Fisicaro, P. A systematic approach to the accurate quantification of selenium in serum selenoalbumin by HPLC-ICP-MS. Anal. Chim. Acta 2010, 657, 100–107. [Google Scholar] [CrossRef]
  117. Polatajko, A.; Encinar, J.R.; Schaumlöffel, D.; Szpunar, J. Quantification of a selenium-containing protein in yeast extract via an accurate determination of a tryptic peptide by species-specific isotope dilution capillary HPLC-ICP MS. Chem. Anal. 2005, 50, 265–278. [Google Scholar]
  118. Konopka, A.; Winter, D.; Konopka, W.; Busto, M.D.C.; Nunez, S.; Goenaga-Infante, H.; Fisicaro, P.; Lehmann, W.D. [Sec-to-Cys]selenoprotein—A novel type of recombinant, full-length selenoprotein standard for quantitative proteomics. J. Anal. At. Spectrom. 2016, 31, 1929–1938. [Google Scholar] [CrossRef]
  119. Konopka, A.; Zinn, N.; Wild, C.; Lehmann, W.D. Preparation of heteroelement-incorporated and stable isotope-labeled protein standards for quantitative proteomics. Adv. Struct. Saf. Stud. 2014, 1156, 337–363. [Google Scholar] [CrossRef]
  120. Fan, T.W.-M.; Pruszkowski, E.; Shuttleworth, S. Speciation of selenoproteins in Se-contaminated wildlife by gel electrophoresis and laser ablation-ICP-MS. J. Anal. At. Spectrom. 2002, 17, 1621–1623. [Google Scholar] [CrossRef]
  121. Ballihaut, G.; Pécheyran, C.; Mounicou, S.; Preud’homme, H.; Grimaud, R.; Lobinski, R.; Ballihaut, G.; Grimaud, R. Multimode detection (LA-ICP-MS, MALDI-MS and nanoHPLC-ESI-MS) in 1D and 2D gel electrophoresis for selenium-containing proteins. TrAC Trends Anal. Chem. 2007, 26, 183–190. [Google Scholar] [CrossRef]
  122. Ballihaut, G.; Tastet, L.; Pécheyran, C.; Bouyssiere, B.; Donard, O.; Grimaud, R.; Łobiński, R. Biosynthesis, purification and analysis of selenomethionyl calmodulin by gel electrophoresis-laser ablation-ICP-MS and capillary HPLC-ICP-MS peptide mapping following in-gel tryptic digestion. J. Anal. At. Spectrom. 2005, 20, 493–499. [Google Scholar] [CrossRef]
  123. Bianga, J.; Touat-Hamici, Z.; Bierla, K.; Mounicou, S.; Szpunar, J.; Chavatte, L.; Lobinski, R. Speciation analysis for trace levels of selenoproteins in cultured human cells. J. Proteom. 2014, 108, 316–324. [Google Scholar] [CrossRef] [PubMed]
  124. Sonet, J.; Mounicou, S.; Chavatte, L. Nonradioactive isotopic labeling and tracing of selenoproteins in cultured cell lines. Adv. Struct. Saf. Stud. 2017, 1661, 193–203. [Google Scholar] [CrossRef]
  125. Ballihaut, G.; Claverie, F.; Pécheyran, C.; Mounicou, S.; Grimaud, R.; Lobinski, R. Sensitive detection of selenoproteins in gel electrophoresis by high repetition rate femtosecond laser ablation-inductively coupled plasma mass spectrometry. Anal. Chem. 2007, 79, 6874–6880. [Google Scholar] [CrossRef]
  126. Schaffer, L.V.; Millikin, R.J.; Miller, R.M.; Anderson, L.C.; Fellers, R.T.; Ge, Y.; Kelleher, N.L.; LeDuc, R.D.; Liu, X.; Payne, S.H.; et al. Identification and quantification of proteoforms by mass spectrometry. Proteomics 2019, 19, e1800361. [Google Scholar] [CrossRef] [PubMed]
  127. Ross, P.L.; Huang, Y.N.; Marchese, J.N.; Williamson, B.; Parker, K.; Hattan, S.; Khainovski, N.; Pillai, S.; Dey, S.; Daniels, S.; et al. Multiplexed protein quantitation in saccharomyces cerevisiae using amine-reactive isobaric tagging reagents. Mol. Cell. Proteom. 2004, 3, 1154–1169. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  128. Kaur, P.; Rizk, N.M.; Ibrahim, S.; Younes, N.; Uppal, A.; Dennis, K.; Karve, T.; Blakeslee, K.; Kwagyan, J.; Zirie, M.; et al. iTRAQ-based quantitative protein expression profiling and mrm verification of markers in type diabetes. J. Proteome Res. 2012, 11, 5527–5539. [Google Scholar] [CrossRef]
  129. Yu, R.; Zhang, J.; Zang, Y.; Zeng, L.; Zuo, W.; Bai, Y.; Liu, Y.; Sun, K.; Liu, Y. iTRAQ-based quantitative protein expression profiling of biomarkers in childhood B-cell and T-cell acute lymphoblastic leukemia. Cancer Manag. Res. 2019, 11, 7047–7063. [Google Scholar] [CrossRef] [Green Version]
  130. Ren, Z.-H.; Bai, L.-P.; Shen, L.-H.; Luo, Z.-Z.; Zhou, Z.-H.; Zuo, Z.-C.; Ma, X.-P.; Deng, J.-L.; Wang, Y.; Xu, S.-Y.; et al. Comparative iTRAQ proteomics reveals multiple effects of selenium yeast on dairy cows in parturition. Biol. Trace Elem. Res. 2020, 197, 464–474. [Google Scholar] [CrossRef]
  131. Jitaru, P.; Cozzi, G.; Gambaro, A.; Cescon, P.; Barbante, C. Simultaneous speciation analysis of glutathione peroxidase, selenoprotein P and selenoalbumin in human serum by tandem anion exchange-affinity HPLC and on-line isotope dilution ICP-quadrupole MS. Anal. Bioanal. Chem. 2008, 391, 661–669. [Google Scholar] [CrossRef]
  132. Liu, Y.; Feng, X.; Yu, Y.; Zhao, Q.; Tang, C.; Zhang, J. A review of bioselenol-specific fluorescent probes: Synthesis, properties, and imaging applications. Anal. Chim. Acta 2020, 1110, 141–150. [Google Scholar] [CrossRef]
  133. Andoh, A.; Hirashima, M.; Maeda, H.; Hata, K.; Inatomi, O.; Tsujikawa, T.; Sasaki, M.; Takahashi, K.; Fujiyama, Y. Serum selenoprotein-P levels in patients with inflammatory bowel disease. Nutrition 2005, 21, 574–579. [Google Scholar] [CrossRef]
  134. Büttner, P.; Obradovic, D.; Wunderlich, S.; Feistritzer, H.-J.; Holzwirth, E.; Lauten, P.; Fuernau, G.; de Waha-Thiele, S.; Desch, S.; Thiele, H. Selenoprotein P in myocardial infarction with cardiogenic shock. Shock 2020, 53, 58–62. [Google Scholar] [CrossRef]
  135. Gül-Klein, S.; Haxhiraj, D.; Seelig, J.; Kästner, A.; Hackler, J.; Sun, Q.; Heller, R.; Lachmann, N.; Pratschke, J.; Schmelzle, M.; et al. Serum selenium status as a diagnostic marker for the prognosis of liver transplantation. Nutrition 2021, 13, 619. [Google Scholar] [CrossRef]
  136. Outzen, M.; Tjønneland, A.; Hughes, D.J.; Jenab, M.; Frederiksen, K.; Schomburg, L.; Morris, S.; Overvad, K.; Olsen, A. Toenail selenium, plasma selenoprotein P and risk of advanced prostate cancer: A nested case-control study. Int. J. Cancer 2021, 148, 876–883. [Google Scholar] [CrossRef]
  137. Hoová, J.; López, I.V.; Soblechero, E.G.; Arias-Borrego, A.; García-Barrera, T. Digging deeper into the mother-offspring transfer of selenium through human breast milk. J. Food Compos. Anal. 2021, 99, 103870. [Google Scholar] [CrossRef]
Figure 1. Putative number of SeCys residues in SELENOP in different organisms (according to [11,12,14]).
Figure 1. Putative number of SeCys residues in SELENOP in different organisms (according to [11,12,14]).
Ijms 22 06283 g001
Figure 2. Sequence of human SELENOP. (a) Amino-acid sequence of human SELENOP [53]; (b) schematic representation of human SELENOP (on the basis of [47,53] and Uniprot database).
Figure 2. Sequence of human SELENOP. (a) Amino-acid sequence of human SELENOP [53]; (b) schematic representation of human SELENOP (on the basis of [47,53] and Uniprot database).
Ijms 22 06283 g002
Figure 3. Schematic overview of the principle of HPLC configuration coupled with ICP-MS for SELENOP determination (a) schematic chromatogram of affinity column heparin coupled with ICP-MS (Se-specific detection) [58,64,68], (b) schematic chromatogram of a size exclusion column followed by an affinity column Heparin coupled with ICP-MS (Se-specific detection) [83,99], (c) schematic chromatogram of affinity column heparin followed by a size exclusion column coupled with ICP-MS (Se-specific detection) [77], (d) schematic chromatogram of multi-affinity columns heparin followed by blue-sepharose coupled with ICP-MS (Se-specific detection) [77,78,84,100,101,102,103], (e) schematic chromatogram of multi-affinity columns heparin followed by blue-sepharose and a size exclusion column coupled with ICP-MS (Se-specific detection) [104], (f) schematic chromatogram of a size exclusion column followed by multi-affinity columns heparin and blue-sepharose coupled with ICP-MS (Se-specific detection) [105,106,107], (g) schematic chromatogram of multi-affinity removal column followed by size exclusion column coupled with ICP-MS (Se-specific detection) [108], (h) schematic chromatogram of a strong anion-exchange column coupled with ICP-MS (Se-specific detection) [109,110,111], (Hep: HiTrap Heparin affinity column, SEC: Size-exclusion chromatography, Blue: HiTrap Blue affinity column, MARC: Multi-affinity removal column, SAX: Strong anion-exchange column).
Figure 3. Schematic overview of the principle of HPLC configuration coupled with ICP-MS for SELENOP determination (a) schematic chromatogram of affinity column heparin coupled with ICP-MS (Se-specific detection) [58,64,68], (b) schematic chromatogram of a size exclusion column followed by an affinity column Heparin coupled with ICP-MS (Se-specific detection) [83,99], (c) schematic chromatogram of affinity column heparin followed by a size exclusion column coupled with ICP-MS (Se-specific detection) [77], (d) schematic chromatogram of multi-affinity columns heparin followed by blue-sepharose coupled with ICP-MS (Se-specific detection) [77,78,84,100,101,102,103], (e) schematic chromatogram of multi-affinity columns heparin followed by blue-sepharose and a size exclusion column coupled with ICP-MS (Se-specific detection) [104], (f) schematic chromatogram of a size exclusion column followed by multi-affinity columns heparin and blue-sepharose coupled with ICP-MS (Se-specific detection) [105,106,107], (g) schematic chromatogram of multi-affinity removal column followed by size exclusion column coupled with ICP-MS (Se-specific detection) [108], (h) schematic chromatogram of a strong anion-exchange column coupled with ICP-MS (Se-specific detection) [109,110,111], (Hep: HiTrap Heparin affinity column, SEC: Size-exclusion chromatography, Blue: HiTrap Blue affinity column, MARC: Multi-affinity removal column, SAX: Strong anion-exchange column).
Ijms 22 06283 g003
Figure 4. Quantification of SELENOP by laser ablation ICP MS. (a) SDS -PAGE of immunoprecipitated SELENOP from serum. Left lane: albumin standard and antibodies bands; Right lane: sample lane; graph: 80Se intensity as a function of position in the gel [65]; (b) Construction of a calibration curve in SDS PAGE—laser ablation ICP MS with GPx [121]. The calibration curve is a linear function of the quantity of protein in the gel. G. Ballihaut, L.E. Kilpatrick, E.L. Kilpatrick, W.C. Davis, Multiple forms of selenoprotein P in candidate human plasma standard reference material, Mettalomics, 2012, 4, 6, 533-538, with permission of Oxford University Press; Reprinted from TrAC Trend in Analytical Chemistry, 26, 3, 2007, G. Ballihaut, C. Pécheyran, S. Monicou, H. Preud’homme, R. Grimaud, R. Lobinski, G. Ballihaut, R. Grimaud, R. Lobinski, Multimode detection (LA-ICP-MS, MALDI-MS and nanoHPLC-ESI-MS²) in 1D and 2D gel-electrophoresis for selenium-containing proteins, 183-190, Copyright (2007), with permission from Elsevier.
Figure 4. Quantification of SELENOP by laser ablation ICP MS. (a) SDS -PAGE of immunoprecipitated SELENOP from serum. Left lane: albumin standard and antibodies bands; Right lane: sample lane; graph: 80Se intensity as a function of position in the gel [65]; (b) Construction of a calibration curve in SDS PAGE—laser ablation ICP MS with GPx [121]. The calibration curve is a linear function of the quantity of protein in the gel. G. Ballihaut, L.E. Kilpatrick, E.L. Kilpatrick, W.C. Davis, Multiple forms of selenoprotein P in candidate human plasma standard reference material, Mettalomics, 2012, 4, 6, 533-538, with permission of Oxford University Press; Reprinted from TrAC Trend in Analytical Chemistry, 26, 3, 2007, G. Ballihaut, C. Pécheyran, S. Monicou, H. Preud’homme, R. Grimaud, R. Lobinski, G. Ballihaut, R. Grimaud, R. Lobinski, Multimode detection (LA-ICP-MS, MALDI-MS and nanoHPLC-ESI-MS²) in 1D and 2D gel-electrophoresis for selenium-containing proteins, 183-190, Copyright (2007), with permission from Elsevier.
Ijms 22 06283 g004
Table 2. SELENOP concentration values reported for the analysis of standard reference materials by HPLC-ICP-MS.
Table 2. SELENOP concentration values reported for the analysis of standard reference materials by HPLC-ICP-MS.
Certified Reference MaterialCalibration (Calibrant)SELENOP Average Concentration
(ng/mL as Se)
Ref.
SRM 1950On-line post-column IDA (77Se)105 ±3.8[84]
IDA
(76 Se enriched peptides)
60.6 ± 3.2[53]
On-line post-column IDA (77Se)61.1 ± 7.4[100]
External (SelP)52 ± 1.6[68]
BCR 637External (selenite)51 ± 1[102]
On-line post-column IDA (77Se)52 ± 5[104]
On-line post-column IDA (77Se)81 ± 7[84]
On-line post-column IDA (77Se)52.7 ± 4.3[100]
IDA
(76Se enriched peptides)
56.2 ± 1.7[53]
On-line post-column IDA (74Se)61 ± 4.3[105]
BCR 638On-line post-column IDA-ICP-MS (77Se)65 ± 5[131]
External (selenite)57± 2
External (selenite)59± 1
On-line post-column IDA (77Se)54 ± 12[104]
BCR 639External (selenite)56 ± 1[102]
On-line post-column IDA (77Se)52 ± 3[104]
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Share and Cite

MDPI and ACS Style

Lamarche, J.; Ronga, L.; Szpunar, J.; Lobinski, R. Characterization and Quantification of Selenoprotein P: Challenges to Mass Spectrometry. Int. J. Mol. Sci. 2021, 22, 6283. https://doi.org/10.3390/ijms22126283

AMA Style

Lamarche J, Ronga L, Szpunar J, Lobinski R. Characterization and Quantification of Selenoprotein P: Challenges to Mass Spectrometry. International Journal of Molecular Sciences. 2021; 22(12):6283. https://doi.org/10.3390/ijms22126283

Chicago/Turabian Style

Lamarche, Jérémy, Luisa Ronga, Joanna Szpunar, and Ryszard Lobinski. 2021. "Characterization and Quantification of Selenoprotein P: Challenges to Mass Spectrometry" International Journal of Molecular Sciences 22, no. 12: 6283. https://doi.org/10.3390/ijms22126283

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop