error_outline You can access the new MDPI.com website here. Explore and share your feedback with us.
 
 
Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (2)

Search Parameters:
Keywords = water–1,6-dichlorohexane

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
15 pages, 3948 KB  
Article
Electrochemical Detection of a Local Anesthetic Dibucaine at Arrays of Liquid|Liquid MicroInterfaces
by Eissa Mohamed Almbrok, Nor Azah Yusof, Jaafar Abdullah and Ruzniza Mohd Zawawi
Chemosensors 2021, 9(1), 15; https://doi.org/10.3390/chemosensors9010015 - 15 Jan 2021
Cited by 4 | Viewed by 3195
Abstract
Electrochemical characterization and detection of protonated dibucaine (DIC+) at microinterface array across water|1,6-dichlorohexane were performed using cyclic voltammetry (CV) and differential pulse voltammetry (DPV). Some thermodynamic parameters of dibucaine, such as the standard transfer potential, the Gibbs energy of transfer [...] Read more.
Electrochemical characterization and detection of protonated dibucaine (DIC+) at microinterface array across water|1,6-dichlorohexane were performed using cyclic voltammetry (CV) and differential pulse voltammetry (DPV). Some thermodynamic parameters of dibucaine, such as the standard transfer potential, the Gibbs energy of transfer and the partition coefficient, were estimated by CV. In addition to the analytical parameters, the impact of bovine serum albumin (BSA) on dibucaine detection (in artificial serum matrices) was also investigated. DPV was applied to detect a lower concentration of DIC+, resulting in a detection limit of 0.9 ± 0.06 µM. While the presence of BSA affected CV, demonstrated as reduced current responses, DPV was confirmed to be an efficient method for lowering concentrations of the dibucaine detection in the artificial serum matrix in the presence of BSA, with a limit of detection (LOD) of 1.9 ± 0.12 µM. Full article
(This article belongs to the Section Electrochemical Devices and Sensors)
Show Figures

Figure 1

16 pages, 4129 KB  
Article
Electrochemical Behavior and Detection of Diclofenac at a Microporous Si3N4 Membrane Modified Water–1,6-dichlorohexane Interface System
by Eissa Mohamed Almbrok, Nor Azah Yusof, Jaafar Abdullah and Ruzniza Mohd Zawawi
Chemosensors 2020, 8(1), 11; https://doi.org/10.3390/chemosensors8010011 - 5 Feb 2020
Cited by 13 | Viewed by 4823
Abstract
The electrochemical behavior when the liquid–liquid interface was modified by commercially available, microporous silicon nitride membrane, was achieved using cyclic voltammetry with tetramethyl ammonium. The transfer characteristics of the ionizable drug diclofenac ( DCF ), as an anti-inflammatory, anti-rheumatic, antipyretic, and analgesic [...] Read more.
The electrochemical behavior when the liquid–liquid interface was modified by commercially available, microporous silicon nitride membrane, was achieved using cyclic voltammetry with tetramethyl ammonium. The transfer characteristics of the ionizable drug diclofenac ( DCF ), as an anti-inflammatory, anti-rheumatic, antipyretic, and analgesic treatment in common use in biomedical applications, were also investigated across microporous silicon nitride-modified liquid interface. Thus, some thermodynamic variables for DCF , such as the standard Gibbs energy of transfer, the standard transfer potential and lipophilicity were estimated. Furthermore, the influence of possible interfering substances (ascorbic acid, sugar, amino acid, urea, and metal ions) on the detection of DCF was investigated. An electrochemical DCF sensor is investigated using differential pulse voltammetry (DPV) as the quantification technique, a linear range of 8–56 µM and a limit of detection of 1.5 µM was possible due to the miniaturized interfaces formed within silicon nitride. Full article
Show Figures

Figure 1

Back to TopTop