Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (7)

Search Parameters:
Keywords = two-dimensional radiation dosimetry

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
16 pages, 9483 KB  
Article
Optically Stimulated Luminescence Silicone Foils for 2D Dose Mapping in Proton Radiotherapy
by Michał Sądel, Leszek Grzanka, Jan Swakoń, Damian Wróbel, Sebastian Kusyk, Lily Bossin and Paweł Bilski
Materials 2025, 18(9), 1928; https://doi.org/10.3390/ma18091928 - 24 Apr 2025
Viewed by 622
Abstract
A novel reusable silicon foil dosimeter based on the new emerging optically stimulated luminescence (OSL) material MgB4O7:Ce,Li (MBO) is developed and characterized for dosimetric verification of spatially resolved radiotherapy doses. Direct comparison of the spatial (two-2D towards three-3D) proton [...] Read more.
A novel reusable silicon foil dosimeter based on the new emerging optically stimulated luminescence (OSL) material MgB4O7:Ce,Li (MBO) is developed and characterized for dosimetric verification of spatially resolved radiotherapy doses. Direct comparison of the spatial (two-2D towards three-3D) proton dose mapping can be achieved with an appropriately designed optical detection setup equipped with a light source (e.g., LEDs) that illuminates the dosimeter and a highly sensitive CCD camera that simultaneously acquires the 2D OSL light from the foil. The newly designed (2nd generation) optical setup allows the registration of high-resolution 2D proton doses (below 0.1 mm resolution) and reconstruction of the 2D proton dose distribution with an accuracy comparable to that of the GafchromicTM foils, the current standard of passive 2D dosimetry in radiotherapy. This article outlines the technology’s potential application with respect to the commercially available GafchromicTM EBT3 films in measurements of the clinically relevant, spatial proton dose mapping. The obtained comparison of the proton radial dose profiles (for EBT3 films vs MBO foils) agrees within 5%. The resulting image resolution (0.074 mm/px for MBO foil) corresponded well with the tested EBT3 films (0.085 mm/px), indicating excellent properties for future 3D proton dose verifications of modern radiotherapy techniques (e.g., proton radiotherapy). Full article
(This article belongs to the Section Advanced Materials Characterization)
Show Figures

Figure 1

12 pages, 1959 KB  
Article
Assessing the Organ Dose in Diagnostic Imaging with Digital Tomosynthesis System Using TLD100H Dosimeters
by Giuseppe Stella, Grazia Asero, Mariajessica Nicotra, Giuliana Candiano, Rosaria Galvagno and Anna Maria Gueli
Tomography 2025, 11(3), 32; https://doi.org/10.3390/tomography11030032 - 11 Mar 2025
Viewed by 803
Abstract
Background: Digital tomosynthesis (DTS) is an advanced imaging modality that enhances diagnostic accuracy by offering three-dimensional visualization from two-dimensional projections, which is particularly beneficial in breast and lung imaging. However, this increased imaging capability raises concerns about patient exposure to ionizing radiation. Methods: [...] Read more.
Background: Digital tomosynthesis (DTS) is an advanced imaging modality that enhances diagnostic accuracy by offering three-dimensional visualization from two-dimensional projections, which is particularly beneficial in breast and lung imaging. However, this increased imaging capability raises concerns about patient exposure to ionizing radiation. Methods: This study explores the energy and angular dependence of thermoluminescent dosimeters (TLDs), specifically TLD100H, to improve the accuracy of organ dose assessment during DTS. Using a comprehensive experimental approach, organ doses were measured in both DTS and traditional RX modes. Results: The results showed lung doses of approximately 3.21 mGy for the left lung and 3.32 mGy for the right lung during DTS, aligning with the existing literature. In contrast, the RX mode yielded significantly lower lung doses of 0.33 mGy. The heart dose during DTS was measured at 2.81 mGy, corroborating findings from similar studies. Conclusions: These results reinforce the reliability of TLD100H dosimetry in assessing radiation exposure and highlight the need for optimizing imaging protocols to minimize doses. Overall, this study contributes to the ongoing dialogue on enhancing patient safety in diagnostic imaging and advocates for collaboration among medical physicists, radiologists, and technologists to establish best practices. Full article
Show Figures

Figure 1

15 pages, 7802 KB  
Article
A Comparison of 3D Conformal and Deep Inspiratory Breath Holding vs. 4D-CT Intensity-Modulated Radiation Therapy for Patients with Left Breast Cancer
by Moustafa Aldaly, Azza Hussien, Inas Mohsen El-nadi, Nabila Ibrahim Laz, Amira S. A. Said, Mohammad M. Al-Ahmad, Raghda R. S. Hussein, Al Shaimaa Ibrahim Rabie and Ahmed Hassan Shaaban
Cancers 2023, 15(24), 5799; https://doi.org/10.3390/cancers15245799 - 11 Dec 2023
Cited by 2 | Viewed by 2471
Abstract
Background: Multimodality is required for the treatment of breast cancer. Surgery, radiation (RT), and systemic therapy were traditionally used. Pharmacotherapy includes different drug mechanisms, such as chemotherapy, hormone therapy, and targeted therapies, alone or in combination with radiotherapy. While radiation offers numerous benefits, [...] Read more.
Background: Multimodality is required for the treatment of breast cancer. Surgery, radiation (RT), and systemic therapy were traditionally used. Pharmacotherapy includes different drug mechanisms, such as chemotherapy, hormone therapy, and targeted therapies, alone or in combination with radiotherapy. While radiation offers numerous benefits, it also has certain harmful risks. such as cardiac and pulmonary toxicity, lymphedema, and secondary cancer. Modern radiation techniques have been developed to reduce organs at risk (OAR) doses. Materials and Methods: This study is a prospective feasibility trial conducted at the Fayium Oncology Center on patients with left breast cancer receiving adjuvant locoregional radiotherapy after either breast conservative surgery (BCS) or modified radical mastectomy (MRM). This study aimed to assess the proportion of patients who are fit both physically and intellectually to undergo breast radiotherapy using the deep inspiratory breath-holding (DIBH) technique, comparing different dosimetric outcomes between the 3D dimensional conformal with DIBH and 4D-CT IMRT plans of the same patient. Results: D95 of the clinical target volume (CTV) of the target is significantly higher in the 3D DIBH plan than in the IMRT plan, with an average of 90.812% vs. 86.944%. The dosimetry of the mean heart dose (MHD) in the 4D-CT IMRT plan was significantly lower than in the 3D conformal with the DIBH plan (2.6224 vs. 4.056 Gy, p < 0.0064), and no significant difference between the two plans regarding mean left anterior descending artery (LAD) (14.696 vs. 13.492 Gy, p < 0.58), maximum LAD (39.9 vs. 43.5 Gy, p < 0.35), and V20 of the ipsilateral lung (18.66% vs. 16.306%, p < 0.88) was observed. Internal mammary chain (IMC) irradiation was better in the 4D-CT IMRT plan. Conclusions: Radiotherapy of the breast and chest wall with the 4D-CT IMRT technique appears not to be inferior to the 3D conformal with the DIBH technique and can be used as an alternative to the 3D conformal with the DIBH technique in patients meeting the exclusion criteria for performing the DIBH maneuver concerning coverage to target volumes or unacceptably high doses to OAR. Full article
(This article belongs to the Special Issue Risk Factor Prediction, Diagnosis and Treatment of Breast Cancer)
Show Figures

Figure 1

15 pages, 6344 KB  
Article
A Fiber-Optical Dosimetry Sensor for Gamma-Ray Irradiation Measurement in Biological Applications
by Adel Shaaban Awad Elsharkawi, Huda A. Alazab, Mahmoud Sayed, Mostafa A. Askar, Ibrahim Y. Abdelrahman, Amany A. Arafa, Hassan I. Saleh, Lotfy R. Gomaa and Yi-Chun Du
Biosensors 2023, 13(12), 1010; https://doi.org/10.3390/bios13121010 - 3 Dec 2023
Cited by 1 | Viewed by 2467
Abstract
In this paper, we propose a novel fiber-optical dosimetry sensor for radiation measurement in biological applications. A two-dimensional (2D) fiber-optical dosimeter (FOD) for radiation measurement is considered. The sensors are arranged as a 2D array in a tailored holder. This FOD targets accurate [...] Read more.
In this paper, we propose a novel fiber-optical dosimetry sensor for radiation measurement in biological applications. A two-dimensional (2D) fiber-optical dosimeter (FOD) for radiation measurement is considered. The sensors are arranged as a 2D array in a tailored holder. This FOD targets accurate industrial and medical applications which seek more tolerant radiation dosimeters. In this paper, the FOD sensors are subjected to gamma-ray radiation facilities from the 137Cs gamma-ray irradiator type for low doses and 60Co gamma-ray irradiator for high doses. For better evaluation of radiation effects on the FOD sample, the measurements are performed using eight sensors (hollow cylinder shape) with two samples in each dose. The sensors were measured before and after each irradiation. To the author’s knowledge, the measurements of FOD transplanted inside animals are presented for the first time in this paper. A 2D simulation program has been implemented for numerical simulation based on the attenuation factors from the absorbed dose inside the in vivo models. A comparison between the FOD and the standard thermo-luminescence detector is presented based on the test of in vivo animal models. The results indicate that the proposed FOD sensor is more stable and has higher sensitivity. Full article
(This article belongs to the Section Optical and Photonic Biosensors)
Show Figures

Graphical abstract

13 pages, 6083 KB  
Article
End-to-End QA with Polymer Gel Dosimeter for Photon Beam Radiation Therapy
by Libing Zhu, Yi Du, Yahui Peng, Xincheng Xiang and Xiangang Wang
Gels 2023, 9(3), 212; https://doi.org/10.3390/gels9030212 - 10 Mar 2023
Cited by 6 | Viewed by 2670
Abstract
With the complexity and high demands on quality assurance (QA) of photon beam radiation therapy, end-to-end (E2E) QA is necessary to validate the entire treatment workflow from pre-treatment imaging to beam delivery. A polymer gel dosimeter is a promising tool for three-dimensional (3D) [...] Read more.
With the complexity and high demands on quality assurance (QA) of photon beam radiation therapy, end-to-end (E2E) QA is necessary to validate the entire treatment workflow from pre-treatment imaging to beam delivery. A polymer gel dosimeter is a promising tool for three-dimensional (3D) dose distribution measurement. The purpose of this study is to design a fast “one delivery” polymethyl methacrylate (PMMA) phantom with a polymer gel dosimeter for the E2E QA test of the photon beam. The one delivery phantom is composed of ten calibration cuvettes for the calibration curve measurement, two 10 cm gel dosimeter inserts for the dose distribution measurement, and three 5.5 cm gel dosimeters for the square field measurement. The one delivery phantom holder is comparable in size and shape to that of a human thorax and abdomen. In addition, an anthropomorphic head phantom was employed to measure the patient-specific dose distribution of a VMAT plan. The E2E dosimetry was verified by undertaking the whole RT procedure (immobilization, CT simulation, treatment planning, phantom set-up, imaged-guided registration, and beam delivery). The calibration curve, field size, and patient-specific dose were measured with a polymer gel dosimeter. The positioning error can be mitigated with the one-delivery PMMA phantom holder. The delivered dose measured with a polymer gel dosimeter was compared with the planned dose. The gamma passing rate is 86.64% with the MAGAT-f gel dosimeter. The results ascertain the feasibility of the one delivery phantom with a polymer gel dosimeter for a photon beam in E2E QA. The QA time can be reduced with the designed one delivery phantom. Full article
(This article belongs to the Special Issue High Performance Gels)
Show Figures

Figure 1

11 pages, 598 KB  
Article
Ultra-Hypofractionated vs. Moderate Fractionated Whole Breast Three Dimensional Conformal Radiotherapy during the COVID-19 Pandemic
by Olivera Ivanov, Aleksandra Milovančev, Borislava Petrović, Nataša Prvulović Bunović, Jelena Ličina, Marko Bojović, Ivan Koprivica, Milijana Rakin, Milana Marjanović, Dejan Ivanov and Nensi Lalić
Medicina 2022, 58(6), 745; https://doi.org/10.3390/medicina58060745 - 30 May 2022
Cited by 7 | Viewed by 4353
Abstract
Background and Objectives: Reducing time of treatment during COVID-19 outbreaks has been recommended by the leading Radiation Oncology societies. Still minimizing radiation induced tissue toxicity is one of the most important issues in breast cancer patients. The study aimed to investigate compliance, [...] Read more.
Background and Objectives: Reducing time of treatment during COVID-19 outbreaks has been recommended by the leading Radiation Oncology societies. Still minimizing radiation induced tissue toxicity is one of the most important issues in breast cancer patients. The study aimed to investigate compliance, clinical and dosimetry normal tissue toxicity, and cosmetic results between moderated and ultra-fractionated regimes for breast cancer patients during COVID-19 pandemic. Materials and Methods: This pilot prospective randomized study included 60 patients with early breast cancer after preserving surgery, 27 patients advocated to ultra-hypofractionated whole-breast three dimensional (3D) conformal radiotherapy of 26 Gy in 5 fractions over 1 week and 33 patients with moderate fractionated breast 3D conformal radiotherapy patients between March 2020 and July 2020, during the COVID pandemic outbreak. The compliance to treatment, dosimetric parameters, acute and late skin toxicity, subcutaneous tissue toxicity, cosmetic results and clinical follow up for 18 months for the two regimes were analyzed and compared. Results: When two regimes were compared 5 fraction group had significantly lower prevalence of newly infected cases of SARS-CoV-2 and thus delayed/interrupted treatment (p = 0.05), comparable grade 1 CTCAE v5, acute skin toxicity (p = 0.18), Grade 1 Radiation Morbidity Scoring Scheme (RESS) subcutaneous tissue toxicity (p = 0.18), Grade 1 RESS late skin toxicity (p = 0.88) and cosmetic results (p = 0.46). Dosimetric results reveled that patients in 5 fraction group received significantly lower median ipsilateral lung doses (p < 0.01) in addition to left breast cancer patients that received significantly lower median heart dose (p < 0.01) and median left anterior descending artery (LAD) dose (p < 0.01). Conclusion: Ultra-hypofractionated radiotherapy for breast cancer is comparable to moderate hypofractionation regimen regarding grade 1 acute skin toxicity, grade 1 subcutaneous tissue toxicity, late skin toxicity and cosmetic results. Application of ultra-hypofractionated radiotherapy with significantly lower radiation doses for lung and heart could be crucial in reducing the risk of acute/late pulmonary and heart radiation-induced toxicity. Full article
(This article belongs to the Topic Cancer Biology and Radiation Therapy)
Show Figures

Figure 1

7 pages, 1566 KB  
Article
Aluminum Nitride Ceramic as an Optically Stimulable Luminescence Dosimeter Plate
by Go Okada, Kentaro Fukuda, Safa Kasap and Takayuki Yanagida
Photonics 2016, 3(2), 23; https://doi.org/10.3390/photonics3020023 - 30 Apr 2016
Cited by 20 | Viewed by 5545
Abstract
Photostimulable storage phosphors have been used in a wide range of applications including radiation measurements in one- and two-dimensional spaces, called point dosimetry and radiography. In this work, we report that an aluminum nitride (AlN) ceramic plate, which is practically used as a [...] Read more.
Photostimulable storage phosphors have been used in a wide range of applications including radiation measurements in one- and two-dimensional spaces, called point dosimetry and radiography. In this work, we report that an aluminum nitride (AlN) ceramic plate, which is practically used as a heat sink (SHAPAL®, Tokuyama Corp., Yamaguchi, Japan), shows good optically-stimulated luminescence (OSL) properties with sufficiently large signal and capability for imaging applications, and we have characterized the AlN plate for OSL applications. Upon interaction with X-rays, the sample color turns yellowish, due to a radiation-induced photoabsorption band in the UV-blue range below ~500 nm. After irradiating the sample with X-rays, an intense OSL emission can be observed in the UV (360 nm) spectral region during stimulation by red light. Although our measurement setup is not optimized, dose detection was confirmed as low as ~3 mGy to over 20 Gy. Furthermore, we have successfully demonstrated that the SHAPAL® AlN ceramic plate has great potential to be used as an imaging plate in radiography. Full article
Show Figures

Graphical abstract

Back to TopTop