Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (5)

Search Parameters:
Keywords = transcutaneous hemoglobin monitoring

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
15 pages, 4295 KB  
Article
Transforming Fundus Photography for Deep Learning-Based Anemia Screening
by Taeseen Kang and Kiyup Nam
J. Clin. Med. 2026, 15(14), 5702; https://doi.org/10.3390/jcm15145702 - 21 Jul 2026
Viewed by 312
Abstract
Background/Objectives: This study aimed to develop and evaluate a noninvasive anemia screening method using fundus photographs analyzed by deep learning models, by transforming circular fundus photographs into square images suitable for convolutional neural network analysis. Methods: A total of 39,036 fundus images and [...] Read more.
Background/Objectives: This study aimed to develop and evaluate a noninvasive anemia screening method using fundus photographs analyzed by deep learning models, by transforming circular fundus photographs into square images suitable for convolutional neural network analysis. Methods: A total of 39,036 fundus images and clinical data collected from 2011 to 2023 were used. Eligible patients had clearly visible macula and optic discs and corresponding hemoglobin measurements. Three image preprocessing methods were applied—untransformed, stretching, and remapping. Results: Among preprocessing methods, the stretching method yielded the most accurate predictions. Deep learning analysis was conducted using multi-tasked cascaded convolutional neural networks. The hemoglobin prediction model based on EfficientNet B5 with remapping preprocessing achieved good performance (R2 = 0.781, MAE = 1.23), while the anemia classification model demonstrated screening accuracy with AUC values exceeding 0.893. Conclusions: Deep learning analysis of fundus photographs demonstrates potential as a noninvasive screening method for anemia. This approach may be particularly beneficial for patients requiring regular hemoglobin monitoring. Full article
(This article belongs to the Section Ophthalmology)
Show Figures

Figure 1

14 pages, 3811 KB  
Article
Signal Quality in Continuous Transcutaneous Bilirubinometry
by Fernando Crivellaro, Anselmo Costa and Pedro Vieira
Sensors 2024, 24(18), 6154; https://doi.org/10.3390/s24186154 - 23 Sep 2024
Cited by 5 | Viewed by 2816
Abstract
Bilirubin is a product of the metabolism of hemoglobin from red blood cells. Higher levels of bilirubin are a sign that either there is an unusual breaking down rate of red blood cells or the liver is not able to eliminate bilirubin, through [...] Read more.
Bilirubin is a product of the metabolism of hemoglobin from red blood cells. Higher levels of bilirubin are a sign that either there is an unusual breaking down rate of red blood cells or the liver is not able to eliminate bilirubin, through bile, into the gastrointestinal tract. For adults, bilirubin is occasionally monitored through urine or invasive blood sampling, whilst all newborns are routinely monitored visually, or non-invasively with transcutaneous measurements (TcBs), due to their biological immaturity to conjugate bilirubin. Neonatal jaundice is a common condition, with higher levels of unconjugated bilirubin concentration having neurotoxic effects. Actual devices used in TcBs are focused on newborn populations, are hand-held, and, in some cases, operate in only two wavelengths, which does not necessarily guarantee reliable results over all skin tones. The same occurs with visual inspections. Based on that, a continuous bilirubin monitoring device for newborns is being developed to overcome visual inspection errors and to reduce invasive procedures. This device, operating optically with a mini-spectrometer in the visible range, is susceptible to patient movements and, consequently, to situations with a lower signal quality for reliable bilirubin concentration estimates on different types of skin. Therefore, as an intermediate development step and, based on skin spectra measurements from adults, this work addresses the device’s placement status prediction as a signal quality indication index. This was implemented by using machine learning (ML), with the best performances being achieved by support vector machine (SVM) models, based on the spectra acquired on the arm and forehead areas. Full article
(This article belongs to the Special Issue Wearable Sensors for Continuous Health Monitoring and Analysis)
Show Figures

Figure 1

12 pages, 2865 KB  
Article
In Association with Other Risk Factors, Smoking Is the Main Predictor for Lower Transcutaneous Oxygen Pressure in Type 2 Diabetes
by Tomislav Bulum, Neva Brkljačić, Angelika Tičinović Ivančić, Maja Čavlović, Ingrid Prkačin and Martina Tomić
Biomedicines 2024, 12(2), 381; https://doi.org/10.3390/biomedicines12020381 - 7 Feb 2024
Cited by 3 | Viewed by 2338
Abstract
Type 2 diabetes mellitus (T2DM) significantly increases the risk of peripheral artery disease (PAD), and diabetes is the leading cause of nontraumatic amputations. This study investigated the risk factors for transcutaneous oxygen pressure (TcPO2) in T2DM, a noninvasive method to quantify skin oxygenation [...] Read more.
Type 2 diabetes mellitus (T2DM) significantly increases the risk of peripheral artery disease (PAD), and diabetes is the leading cause of nontraumatic amputations. This study investigated the risk factors for transcutaneous oxygen pressure (TcPO2) in T2DM, a noninvasive method to quantify skin oxygenation and the underlying microvascular circulation. The study included 119 T2DM patients (91 male/28 female). TcPO2 measurements were conducted with the Tina TCM4 Series transcutaneous monitor (Radiometer, Copenhagen, Sweden) and skin electrodes. Patients with TcPO2 < 40 mmHg were younger (p = 0.001), had significantly higher systolic blood pressure (SBP) (p = 0.023), glycated hemoglobin (HbA1c) (p = 0.013), fasting plasma glucose (fPG) (p = 0.038), total cholesterol (p = 0.006), LDL cholesterol (p = 0.004), and had more frequent smoking habits (p = 0.001) than those with TcPO2 ≥ 40 mmHg. The main predictors for the TcPO2 value (R2 = 0.211) obtained via stepwise regression analysis were age, smoking, SBP, HbA1c, fPG, and total and LDL cholesterol. Among all the listed predictors, smoking, HbA1c, and LDL cholesterol were found to be the most significant, with negative parameter estimates of −3.051310 (p = 0.0007), −2.032018 (p = 0.0003), and −2.560353 (p = 0.0046). The results of our study suggest that in association with other risk factors, smoking is the main predictor for lower TcPO2 in T2DM. Full article
(This article belongs to the Special Issue New Advances in Insulin—100 Years Since Its Discovery)
Show Figures

Figure 1

10 pages, 1573 KB  
Article
Impact of Increased End-Tidal Carbon Dioxide on Continuous Noninvasive Hemoglobin Monitoring during Laparoscopic Gastrectomy: A Randomized Controlled Study
by Ha-Yeon Kim, Jong-Bum Choi, Sang-Uk Han, Hye-Sun Lee, Kyuhyeok Lee and Ji-Eun Kim
J. Pers. Med. 2022, 12(2), 160; https://doi.org/10.3390/jpm12020160 - 26 Jan 2022
Cited by 1 | Viewed by 2847
Abstract
The pulse CO-Oximetry allows continuous, noninvasive monitoring of hemoglobin (SpHb). We assessed the impact of increased end-tidal carbon dioxide (EtCO2) on the accuracy and trending ability of SpHb in laparoscopic surgery. Participants (n = 64) were randomly allocated to the [...] Read more.
The pulse CO-Oximetry allows continuous, noninvasive monitoring of hemoglobin (SpHb). We assessed the impact of increased end-tidal carbon dioxide (EtCO2) on the accuracy and trending ability of SpHb in laparoscopic surgery. Participants (n = 64) were randomly allocated to the low carbon dioxide (CO2) group (EtCO2: 30–35 mmHg) or the high CO2 group (EtCO2: 40–45 mmHg). The SpHb and laboratory hemoglobin (tHb) were obtained during surgery. The correlation coefficient (r) between SpHb and tHb showed greater tendency in the low CO2 group (r = 0.68) than in the high CO2 group (r = 0.43). The bias (precision) was −1.18 (1.09) with a limit of agreement (LOA) of −3.31 to 0.95 in low CO2 group and −1.02 (1.24) with a LOA of −3.45 to 1.42 in high CO2 group; they did not differ significantly between the groups (p = 0.246). The low CO2 group showed a high concordance rate of 95.9% and a moderate correlation between ΔSpHb and ΔtHb (r = 0.53). However, the high CO2 group showed a concordance rate of 77.8% and no correlation between ΔSpHb and ΔtHb (r = 0.11). In conclusion, increased EtCO2 significantly reduced the trending ability of SpHb during laparoscopic surgery. Caution should be executed when interpreting SpHb values during laparoscopic surgery in patients with hypercapnia. Full article
Show Figures

Figure 1

17 pages, 4479 KB  
Article
In Vivo Transcutaneous Monitoring of Hemoglobin Derivatives Using a Red-Green-Blue Camera-Based Spectral Imaging Technique
by Fahima Khatun, Yoshihisa Aizu and Izumi Nishidate
Int. J. Mol. Sci. 2021, 22(4), 1528; https://doi.org/10.3390/ijms22041528 - 3 Feb 2021
Cited by 7 | Viewed by 4305
Abstract
Cyanosis is a pathological condition that is characterized by a bluish discoloration of the skin or mucous membranes. It may result from a number of medical conditions, including disorders of the respiratory system and central nervous system, cardiovascular diseases, peripheral vascular diseases, deep [...] Read more.
Cyanosis is a pathological condition that is characterized by a bluish discoloration of the skin or mucous membranes. It may result from a number of medical conditions, including disorders of the respiratory system and central nervous system, cardiovascular diseases, peripheral vascular diseases, deep vein thrombosis, and regional ischemia. Cyanosis can also be elicited from methemoglobin. Therefore, a simple, rapid, and simultaneous monitoring of changes in oxygenated hemoglobin and deoxygenated hemoglobin is useful for protective strategies against organ ischemic injury. We previously developed a red-green-blue camera-based spectral imaging method for the measurements of melanin concentration, oxygenated hemoglobin concentration (CHbO), deoxygenated hemoglobin concentration (CHbR), total hemoglobin concentration (CHbT) and tissue oxygen saturation (StO2) in skin tissues. We leveraged this approach in this study and extended it to the simultaneous quantifications of methemoglobin concentration (CmetHb), CHbO, CHbR, and StO2. The aim of the study was to confirm the feasibility of the method to monitor CmetHb, CHbO, CHbR, CHbT, and StO2. We performed in vivo experiments using rat dorsal skin during methemoglobinemia induced by the administration of sodium nitrite (NaNO2) and changing the fraction of inspired oxygen (FiO2), including normoxia, hypoxia, and anoxia. Spectral diffuse reflectance images were estimated from an RGB image by the Wiener estimation method. Multiple regression analysis based on Monte Carlo simulations of light transport was used to estimate CHbO, CHbR, CmetHb, CHbT, and StO2. CmetHb rapidly increased with a half-maximum time of less than 30 min and reached maximal values nearly 60 min after the administration of NaNO2, whereas StO2 dramatically dropped after the administration of NaNO2, indicating the temporary production of methemoglobin and severe hypoxemia during methemoglobinemia. Time courses of CHbT and StO2, while changing the FiO2, coincided with well-known physiological responses to hyperoxia, normoxia, and hypoxia. The results indicated the potential of this method to evaluate changes in skin hemodynamics due to loss of tissue viability and vitality. Full article
(This article belongs to the Special Issue Protective Strategies against Organ Ischemic Injury)
Show Figures

Figure 1

Back to TopTop