Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (1)

Search Parameters:
Keywords = thiamine monophospahte

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
12 pages, 404 KB  
Article
Comparable Performance Characteristics of Plasma Thiamine and Erythrocyte Thiamine Diphosphate in Response to Thiamine Fortification in Rural Cambodian Women
by Adrian McCann, Øivind Midttun, Kyly C. Whitfield, Hou Kroeun, Mam Borath, Prak Sophonneary, Per Magne Ueland and Timothy J. Green
Nutrients 2017, 9(7), 676; https://doi.org/10.3390/nu9070676 - 29 Jun 2017
Cited by 17 | Viewed by 5459
Abstract
Background: Traditionally, vitamin B1 status is assessed by a functional test measuring erythrocyte transketolase (ETK) activity or direct measurement of erythrocyte thiamine diphosphate (eThDP) concentration. However, such analyses are logistically challenging, and do not allow assessment of vitamin B1 status [...] Read more.
Background: Traditionally, vitamin B1 status is assessed by a functional test measuring erythrocyte transketolase (ETK) activity or direct measurement of erythrocyte thiamine diphosphate (eThDP) concentration. However, such analyses are logistically challenging, and do not allow assessment of vitamin B1 status in plasma/serum samples stored in biobanks. Using a multiplex assay, we evaluated plasma concentrations of thiamine and thiamine monophosphate (TMP), as alternative, convenient measures of vitamin B1 status. Methods: We investigated the relationships between the established biomarker eThDP and plasma concentrations of thiamine and TMP, and compared the response of these thiamine forms to thiamine fortification using samples from 196 healthy Cambodian women (aged 18–45 years.). eThDP was measured by high performance liquid chromatography with fluorescence detection (HPLC-FLD) and plasma thiamine and TMP by high performance liquid chromatography-tandem mass spectrometry (LC-MS/MS). Results: Plasma thiamine and TMP correlated significantly with eThDP at baseline and study-end (p < 0.05). Among the fortification groups, the strongest response was observed for plasma thiamine (increased by 266%), while increases in plasma TMP (60%) and eThDP (53%) were comparable. Conclusions: Plasma thiamine and TMP correlated positively with eThDP, and all thiamine forms responded significantly to thiamine intervention. Measuring plasma concentrations of thiamine forms is advantageous due to convenient sample handling and capacity to develop low volume, high-throughput, multiplex assays. Full article
Show Figures

Figure 1

Back to TopTop