Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (1)

Search Parameters:
Keywords = reflector-guided localisation

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
15 pages, 4543 KB  
Article
Reflector-Guided Localisation of Non-Palpable Breast Lesions: A Prospective Evaluation of the SAVI SCOUT® System
by Umar Wazir, Iham Kasem, Michael J. Michell, Tamara Suaris, David Evans, Anmol Malhotra and Kefah Mokbel
Cancers 2021, 13(10), 2409; https://doi.org/10.3390/cancers13102409 - 17 May 2021
Cited by 27 | Viewed by 6871
Abstract
Wire-guided localisation (WGL) has been the mainstay for localising non-palpable breast lesions before excision. Due to its limitations, various wireless alternatives have been developed. In this prospective study, we evaluate the role of radiation-free wireless localisation using the SAVI SCOUT® system at [...] Read more.
Wire-guided localisation (WGL) has been the mainstay for localising non-palpable breast lesions before excision. Due to its limitations, various wireless alternatives have been developed. In this prospective study, we evaluate the role of radiation-free wireless localisation using the SAVI SCOUT® system at the London Breast Institute. A total of 72 reflectors were deployed in 67 consecutive patients undergoing breast conserving surgery for non-palpable breast lesions. The mean interval between deployment and surgery for the therapeutic cases was 18.8 days (range: 0–210). The median deployment duration was 5 min (range: 1–15 min). The mean distance from the lesion was 1.1 mm (median distance: 0; range: 0–20 mm). The rate of surgical localisation and retrieval of the reflector was 98.6% and 100%, respectively. The median operating time was 28 min (range: 15–55 min) for the therapeutic excision of malignancy and 17 min (range: 15–24) for diagnostic excision. The incidence of reflector migration was 0%. Radial margin positivity in malignant cases was 7%. The median weight for malignant lesions was 19.6 g (range: 3.5–70 g). Radiologists and surgeons rated the system higher than WGL (93.7% and 98.6%, respectively; 60/64 and 70/71). The patient mean satisfaction score was 9.7/10 (n = 47, median = 10; range: 7–10). One instance of signal failure was reported. In patients who had breast MRI after the deployment of the reflector, the MRI void signal was <5 mm (n = 6). There was no specific technique-related surgical complication. Our study demonstrates that wire-free localisation using SAVI SCOUT® is an effective and time-efficient alternative to WGL with excellent physician and patient acceptance. Full article
Show Figures

Figure 1

Back to TopTop