Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (4)

Search Parameters:
Keywords = radiochromic hydrogels

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
54 pages, 26509 KiB  
Review
Radiation Dosimetry by Use of Radiosensitive Hydrogels and Polymers: Mechanisms, State-of-the-Art and Perspective from 3D to 4D
by Yves De Deene
Gels 2022, 8(9), 599; https://doi.org/10.3390/gels8090599 - 19 Sep 2022
Cited by 73 | Viewed by 6523
Abstract
Gel dosimetry was developed in the 1990s in response to a growing need for methods to validate the radiation dose distribution delivered to cancer patients receiving high-precision radiotherapy. Three different classes of gel dosimeters were developed and extensively studied. The first class of [...] Read more.
Gel dosimetry was developed in the 1990s in response to a growing need for methods to validate the radiation dose distribution delivered to cancer patients receiving high-precision radiotherapy. Three different classes of gel dosimeters were developed and extensively studied. The first class of gel dosimeters is the Fricke gel dosimeters, which consist of a hydrogel with dissolved ferrous ions that oxidize upon exposure to ionizing radiation. The oxidation results in a change in the nuclear magnetic resonance (NMR) relaxation, which makes it possible to read out Fricke gel dosimeters by use of quantitative magnetic resonance imaging (MRI). The radiation-induced oxidation in Fricke gel dosimeters can also be visualized by adding an indicator such as xylenol orange. The second class of gel dosimeters is the radiochromic gel dosimeters, which also exhibit a color change upon irradiation but do not use a metal ion. These radiochromic gel dosimeters do not demonstrate a significant radiation-induced change in NMR properties. The third class is the polymer gel dosimeters, which contain vinyl monomers that polymerize upon irradiation. Polymer gel dosimeters are predominantly read out by quantitative MRI or X-ray CT. The accuracy of the dosimeters depends on both the physico-chemical properties of the gel dosimeters and on the readout technique. Many different gel formulations have been proposed and discussed in the scientific literature in the last three decades, and scanning methods have been optimized to achieve an acceptable accuracy for clinical dosimetry. More recently, with the introduction of the MR-Linac, which combines an MRI-scanner and a clinical linear accelerator in one, it was shown possible to acquire dose maps during radiation, but new challenges arise. Full article
(This article belongs to the Special Issue Gel Dosimetry)
Show Figures

Figure 1

14 pages, 2794 KiB  
Review
Recent Advances in Hydrogel-Based Sensors Responding to Ionizing Radiation
by Ping Zhang, Li Jiang, Hong Chen and Liang Hu
Gels 2022, 8(4), 238; https://doi.org/10.3390/gels8040238 - 12 Apr 2022
Cited by 33 | Viewed by 4206
Abstract
Ionizing radiation and its applications are widely spread throughout life. Similar to many other things, both the positive and negative aspects of ionizing radiation should always be kept in mind. For example, a proper radiation dose can be delivered to tumor tissue to [...] Read more.
Ionizing radiation and its applications are widely spread throughout life. Similar to many other things, both the positive and negative aspects of ionizing radiation should always be kept in mind. For example, a proper radiation dose can be delivered to tumor tissue to kill malignant cells in radiotherapy. On the other hand, exceeding this dose can damage the normal tissues of a human organism. Therefore, the application of sensors for measuring ionizing radiation doses is of utmost importance in many fields, especially in cancer therapy. Traditional dosimeters, such as ionization chambers, silicon diodes and thermoluminescence dosimeters, are widely used. However, they have limitations in certain aspects. Hydrogel-based sensors (or dosimeters) for measuring ionizing radiation doses attract extensive attention for decades due to their equivalence to living tissue and biocompatibility. In this review, we catalog hydrogel-based dosimeters such as polymer, Fricke, radio-chromic, radio-fluorescence and NPs-embedded dosimeters. Most of them demonstrate desirable linear response and sensitivity regardless of energy and dose rate of ionizing radiation. We aim to review these dosimeters and their potential applications in radiotherapy as well as to stimulate a joint work of the experts from different fields such as materials science, chemistry, cancer therapy, radiobiology and nuclear science. Full article
(This article belongs to the Special Issue Gel Dosimetry)
Show Figures

Graphical abstract

13 pages, 12404 KiB  
Article
Study of NBT–Pluronic F–127 Gels as 1D UV Radiation Dosimeters for Measurement of Artificial Light Sources
by Elżbieta Sąsiadek-Andrzejczak, Agata Mądrakowska and Marek Kozicki
Materials 2022, 15(7), 2370; https://doi.org/10.3390/ma15072370 - 23 Mar 2022
Cited by 3 | Viewed by 2223
Abstract
This work reports on radiochromic dosimeters for 1D UV light measurements. The dosimeter is composed of a 25% Pluronic F–127 that forms a physical gel matrix and nitro blue tetrazolium chloride (NBT) as a radiation-sensitive compound. This dosimeter was exposed to UVA, UVB [...] Read more.
This work reports on radiochromic dosimeters for 1D UV light measurements. The dosimeter is composed of a 25% Pluronic F–127 that forms a physical gel matrix and nitro blue tetrazolium chloride (NBT) as a radiation-sensitive compound. This dosimeter was exposed to UVA, UVB and UVC radiation, and the radiochromic reactions were followed with reflectance spectrophotometry including changes in light reflectance and color coordinates in the CIELAB color system. The exposition of dosimeters to all UV radiation caused color changes from pale yellow to dark violet, and its intensity increased with increasing absorbed dose. The effects of NBT concentration and UV radiation type on the dose–response of the dosimeters were also examined. The results obtained reveal that the dosimeters are the least sensitive to irradiation with UVC and the most sensitive to irradiation with UVB (e.g., dosimeter with 2 g/dm3 of NBT was characterized by the following parameters: the threshold dose 0.1 J/cm2; the dose sensitivity −5.97 ± 0.69 cm2/J; the linear dose range 0.1–2.5 J/cm2; the dynamic dose range was equal to 0.1–3 J/cm2). The results obtained reveal that the NBT–Pluronic F–127 dosimeters can be potentially useful as 1D sensors for artificial UV radiation sources measurements. Full article
(This article belongs to the Section Smart Materials)
Show Figures

Figure 1

19 pages, 11735 KiB  
Article
NBT-Pluronic F-127 Hydrogels Printed on Flat Textiles as UV Radiation Sensors
by Elżbieta Sąsiadek, Malwina Jaszczak, Joanna Skwarek and Marek Kozicki
Materials 2021, 14(12), 3435; https://doi.org/10.3390/ma14123435 - 21 Jun 2021
Cited by 12 | Viewed by 2763
Abstract
This work reports on the surface-modified woven fabrics for use as UV radiation sensors. The cotton and polyamide fabrics were printed with radiochromic hydrogels using a screen-printing method. The hydrogels used as a printing paste were composed of water, poly(ethylene oxide)-block-poly(propylene [...] Read more.
This work reports on the surface-modified woven fabrics for use as UV radiation sensors. The cotton and polyamide fabrics were printed with radiochromic hydrogels using a screen-printing method. The hydrogels used as a printing paste were composed of water, poly(ethylene oxide)-block-poly(propylene oxide)-block-poly(ethylene oxide) (Pluronic F-127) as a gel matrix and nitro blue tetrazolium chloride as a radiation-sensitive compound. The development of the hydrogels’ colour occurs after exposure to UV radiation and its intensity increases with increasing absorbed dose. The features of the NBT-Pluronic F-127 radiochromic hydrogels and the fabrics printed with the hydrogels were examined using UV-Vis and reflectance spectrophotometry as well as scanning electron microscopy (SEM). The effects of NBT concentration and UV radiation type (UVA, UVB, UVC) on dose responses of the hydrogels and printed fabrics were also examined. The results obtained reveal that the fabrics printed with NBT-Pluronic F-127 hydrogels can be potentially useful as UV radiation sensors. Full article
(This article belongs to the Section Smart Materials)
Show Figures

Figure 1

Back to TopTop