Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (3)

Search Parameters:
Keywords = porous metal–ceramic nanocomposites

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
16 pages, 2390 KiB  
Article
Peelable Nanocomposite Coatings: “Eco-Friendly” Tools for the Safe Removal of Radiopharmaceutical Spills or Accidental Contamination of Surfaces in General-Purpose Radioisotope Laboratories
by Traian Rotariu, Daniela Pulpea, Gabriela Toader, Edina Rusen, Aurel Diacon, Valentina Neculae and John Liggat
Pharmaceutics 2022, 14(11), 2360; https://doi.org/10.3390/pharmaceutics14112360 - 1 Nov 2022
Cited by 8 | Viewed by 2423
Abstract
Radioactive materials are potentially harmful due to the radiation emitted by radionuclides and the risk of radioactive contamination. Despite strict compliance with safety protocols, contamination with radioactive materials is still possible. This paper describes innovative and inexpensive formulations that can be employed as [...] Read more.
Radioactive materials are potentially harmful due to the radiation emitted by radionuclides and the risk of radioactive contamination. Despite strict compliance with safety protocols, contamination with radioactive materials is still possible. This paper describes innovative and inexpensive formulations that can be employed as ‘eco-friendly’ tools for the safe decontamination of radiopharmaceuticals spills or other accidental radioactive contamination of the surfaces arising from general-purpose radioisotope handling facilities (radiopharmaceutical laboratories, hospitals, research laboratories, etc.). These new peelable nanocomposite coatings are obtained from water-based, non-toxic, polymeric blends containing readily biodegradable components, which do not damage the substrate on which they are applied while also displaying efficient binding and removal of the contaminants from the targeted surfaces. The properties of the film-forming decontamination solutions were assessed using rheological measurements and evaporation rate tests, while the resulting strippable coatings were subjected to Fourier-transform infrared spectroscopy (FTIR), thermogravimetric analysis (TGA), differential scanning calorimetry (DSC), and tensile tests. Radionuclide decontamination tests were performed on various types of surfaces encountered in radioisotope workspaces (concrete, painted metal, ceramic tiles, linoleum, epoxy resin cover). Thus, it was shown that they possess remarkable properties (thermal and mechanical resistance which permits facile removal through peeling) and that their capacity to entrap and remove beta and alpha particle emitters depends on the constituents of the decontaminating formulation, but more importantly, on the type of surface tested. Except for the cement surface (which was particularly porous), at which the decontamination level ranged between approximately 44% and 89%, for all the other investigated surfaces, a decontamination efficiency ranging from 80.6% to 96.5% was achieved. Full article
(This article belongs to the Special Issue Recent Advances in Radiopharmacy)
Show Figures

Figure 1

14 pages, 6896 KiB  
Review
Antiviral Characterization of Advanced Materials: Use of Bacteriophage Phi 6 as Surrogate of Enveloped Viruses Such as SARS-CoV-2
by Ángel Serrano-Aroca
Int. J. Mol. Sci. 2022, 23(10), 5335; https://doi.org/10.3390/ijms23105335 - 10 May 2022
Cited by 37 | Viewed by 5213
Abstract
The bacteriophage phi 6 is a virus that belongs to a different Baltimore group than SARS-CoV-2 (group III instead of IV). However, it has a round-like shape and a lipid envelope like SARS-CoV-2, which render it very useful to be used as a [...] Read more.
The bacteriophage phi 6 is a virus that belongs to a different Baltimore group than SARS-CoV-2 (group III instead of IV). However, it has a round-like shape and a lipid envelope like SARS-CoV-2, which render it very useful to be used as a surrogate of this infectious pathogen for biosafety reasons. Thus, recent antiviral studies have demonstrated that antiviral materials such as calcium alginate hydrogels, polyester-based fabrics coated with benzalkonium chloride (BAK), polyethylene terephthalate (PET) coated with BAK and polyester-based fabrics coated with cranberry extracts or solidified hand soap produce similar log reductions in viral titers of both types of enveloped viruses after similar viral contact times. Therefore, researchers with no access to biosafety level 3 facilities can perform antiviral tests of a broad range of biomaterials, composites, nanomaterials, nanocomposites, coatings and compounds against the bacteriophage phi 6 as a biosafe viral model of SARS-CoV-2. In fact, this bacteriophage has been used as a surrogate of SARS-CoV-2 to test a broad range of antiviral materials and compounds of different chemical natures (polymers, metals, alloys, ceramics, composites, etc.) and forms (films, coatings, nanomaterials, extracts, porous supports produced by additive manufacturing, etc.) during the current pandemic. Furthermore, this biosafe viral model has also been used as a surrogate of SARS-CoV-2 and other highly pathogenic enveloped viruses such as Ebola and influenza in a wide range of biotechnological applications. Full article
(This article belongs to the Collection State-of-the-Art Macromolecules in Spain)
Show Figures

Graphical abstract

18 pages, 2352 KiB  
Article
Separation of Biological Entities from Human Blood by Using Magnetic Nanocomposites Obtained from Zeolite Precursors
by Serena Esposito, Antonello Marocco, Gianfranco Dell’Agli, Barbara Bonelli, Franca Mannu, Paolo Allia, Paola Tiberto, Gabriele Barrera and Michele Pansini
Molecules 2020, 25(8), 1803; https://doi.org/10.3390/molecules25081803 - 14 Apr 2020
Cited by 13 | Viewed by 3164
Abstract
In this work, three novel magnetic metal–ceramic nanocomposites were obtained by thermally treating Fe-exchanged zeolites (either A or X) under reducing atmosphere at relatively mild temperatures (750–800 °C). The so-obtained materials were thoroughly characterized from the point of view of their physico-chemical properties [...] Read more.
In this work, three novel magnetic metal–ceramic nanocomposites were obtained by thermally treating Fe-exchanged zeolites (either A or X) under reducing atmosphere at relatively mild temperatures (750–800 °C). The so-obtained materials were thoroughly characterized from the point of view of their physico-chemical properties and, then, used as magnetic adsorbents in the separation of the target gene factors V and RNASE and of the Staphylococcus aureus bacteria DNA from human blood. Such results were compared with those obtained by using a top ranking commercial separation system (namely, SiMAG-N-DNA by Chemicell). The results obtained by using the novel magnetic adsorbents were similar to (or even better than) those obtained by using the commercial system, both during manual and automated separations, provided that a proper protocol was adopted. Particularly, the novel magnetic adsorbents showed high sensitivity during tests performed with small volumes of blood. Finally, the feasible production of such magnetic adsorbents by an industrial process was envisaged as well. Full article
(This article belongs to the Special Issue New Nanomaterials: Synthesis, Characterization and Applications)
Show Figures

Figure 1

Back to TopTop