Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (5)

Search Parameters:
Keywords = poly(ethylene-vinyl acetate) (PEVA)

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
12 pages, 4714 KiB  
Article
Bio-Inspired Magnetically Controlled Reversibly Actuating Multimaterial Fibers
by Muhammad Farhan, Daniel S. Hartstein, Yvonne Pieper, Marc Behl, Andreas Lendlein and Axel T. Neffe
Polymers 2023, 15(9), 2233; https://doi.org/10.3390/polym15092233 - 8 May 2023
Cited by 3 | Viewed by 2232
Abstract
Movements in plants, such as the coiling of tendrils in climbing plants, have been studied as inspiration for coiling actuators in robotics. A promising approach to mimic this behavior is the use of multimaterial systems that show different elastic moduli. Here, we report [...] Read more.
Movements in plants, such as the coiling of tendrils in climbing plants, have been studied as inspiration for coiling actuators in robotics. A promising approach to mimic this behavior is the use of multimaterial systems that show different elastic moduli. Here, we report on the development of magnetically controllable/triggerable multimaterial fibers (MMFs) as artificial tendrils, which can reversibly coil and uncoil on stimulation from an alternating magnetic field. These MMFs are based on deformed shape-memory fibers with poly[ethylene-co-(vinyl acetate)] (PEVA) as their core and a silicone-based soft elastomeric magnetic nanocomposite shell. The core fiber provides a temperature-dependent expansion/contraction that propagates the coiling of the MMF, while the shell enables inductive heating to actuate the movements in these MMFs. Composites with mNP weight content ≥ 15 wt% were required to achieve heating suitable to initiate movement. The MMFs coil upon application of the magnetic field, in which a degree of coiling N = 0.8 ± 0.2 was achieved. Cooling upon switching OFF the magnetic field reversed some of the coiling, giving a reversible change in coiling ∆n = 2 ± 0.5. These MMFs allow magnetically controlled remote and reversible actuation in artificial (soft) plant-like tendrils, and are envisioned as fiber actuators in future robotics applications. Full article
(This article belongs to the Special Issue Frontier in Magneto-/ Electro-Active Elastomers)
Show Figures

Graphical abstract

22 pages, 4776 KiB  
Article
Biomedical PEVA Nanocomposite with Dual Clay Nanofiller: Cytotoxicity, Mechanical Properties, and Biostability
by Tuty Fareyhynn Mohammed Fitri, Azlin Fazlina Osman, Eid M. Alosime, Rahimah Othman, Fatimah Hashim and Mohd Aidil Adhha Abdullah
Polymers 2021, 13(24), 4345; https://doi.org/10.3390/polym13244345 - 12 Dec 2021
Cited by 7 | Viewed by 3285
Abstract
Poly(ethylene-vinyl acetate) (PEVA) nanocomposite incorporating dual clay nanofiller (DCN) of surface modified montmorillonite (S-MMT) and bentonite (Bent) was studied for biomedical applications. In order to overcome agglomeration of the DCN, the S-MMT and Bent were subjected to a physical treatment prior to being [...] Read more.
Poly(ethylene-vinyl acetate) (PEVA) nanocomposite incorporating dual clay nanofiller (DCN) of surface modified montmorillonite (S-MMT) and bentonite (Bent) was studied for biomedical applications. In order to overcome agglomeration of the DCN, the S-MMT and Bent were subjected to a physical treatment prior to being mixed with the copolymer to form nanocomposite material. The S-MMT and Bent were physically treated to become S-MMT(P) and Bent(pH-s), respectively, that could be more readily dispersed in the copolymer matrix due to increments in their basal spacing and loosening of their tactoid structure. The biocompatibility of both nanofillers was assessed through a fibroblast cell cytotoxicity assay. The mechanical properties of the neat PEVA, PEVA nanocomposites, and PEVA-DCN nanocomposites were evaluated using a tensile test for determining the best S-MMT(P):Bent(pH-s) ratio. The results were supported by morphological studies by transmission electron microscopy (TEM) and scanning electron microscopy (SEM). Biostability evaluation of the samples was conducted by comparing the ambient tensile test data with the in vitro tensile test data (after being immersed in simulated body fluid at 37 °C for 3 months). The results were supported by surface degradation analysis. Our results indicate that the cytotoxicity level of both nanofillers reduced upon the physical treatment process, making them safe to be used in low concentration as dual nanofillers in the PEVA-DCN nanocomposite. The results of tensile testing, SEM, and TEM proved that the ratio of 4:1 (S-MMT(P):Bent(pH-s)) provides a greater enhancement in the mechanical properties of the PEVA matrix. The biostability assessment indicated that the PEVA-DCN nanocomposite can achieve much better retention in tensile strength after being subjected to the simulated physiological fluid for 3 months with less surface degradation effect. These findings signify the potential of the S-MMT(P)/Bent(pH-s) as a reinforcing DCN, with simultaneous function as biostabilizing agent to the PEVA copolymer for implant application. Full article
(This article belongs to the Special Issue Intrinsically Biocompatible Polymer Systems II)
Show Figures

Graphical abstract

22 pages, 4271 KiB  
Article
Development and In Vitro Evaluation of 5-Fluorouracil-Eluting Stents for the Treatment of Colorectal Cancer and Cancer-Related Obstruction
by Mohammad Arafat, Paris Fouladian, Anthony Wignall, Yunmei Song, Ankit Parikh, Hugo Albrecht, Clive A. Prestidge, Sanjay Garg and Anton Blencowe
Pharmaceutics 2021, 13(1), 17; https://doi.org/10.3390/pharmaceutics13010017 - 24 Dec 2020
Cited by 23 | Viewed by 4453
Abstract
Self-expanding metal stents (SEMSs) are currently the gold standard for the localised management of malignant gastrointestinal (GI) stenosis and/or obstructions. Despite encouraging clinical success, in-stent restenosis caused by tumour growth is a significant challenge. Incorporating chemotherapeutic drugs into GI stents is an emerging [...] Read more.
Self-expanding metal stents (SEMSs) are currently the gold standard for the localised management of malignant gastrointestinal (GI) stenosis and/or obstructions. Despite encouraging clinical success, in-stent restenosis caused by tumour growth is a significant challenge. Incorporating chemotherapeutic drugs into GI stents is an emerging strategy to provide localised and sustained release of drugs to intestinal malignant tissues to prevent tumour growth. Therefore, the aim of this work was to develop and evaluate a local GI stent-based delivery system that provides a controlled release of 5-fluorouracil (5FU) over a course of several weeks to months, for the treatment of colorectal cancer and cancer-related stenosis/obstructions. The 5FU-loaded GI stents were fabricated via sequential dip-coating of commercial GI stents with a drug-loaded polyurethane (PU) basecoat and a drug-free poly(ethylene-co-vinyl acetate) (PEVA) topcoat. For comparison, two types of commercial stents were investigated, including bare and silicone (Si) membrane-covered stents. The physicochemical properties of the 5FU-loaded stents were evaluated using photoacoustic Fourier-transform infrared (PA-FTIR) spectroscopy, X-ray diffraction (XRD), X-ray photoelectron spectroscopy (XPS), scanning electron microscopy (SEM), and thermal analysis. In vitro release studies in biological medium revealed that the 5FU-loaded stents provided a sustained release of drug over the period studied (18 d), and cell viability, cell cycle distribution and apoptosis assays showed that the released 5FU had comparable anticancer activity against human colon cancer cells (HCT-116) to pure 5FU. This study demonstrates that dip-coating is a facile and reliable approach for fabricating drug-eluting stents (DESs) that are promising candidates for the treatment of GI obstructions and/or restenosis. Full article
Show Figures

Figure 1

17 pages, 2660 KiB  
Article
Influence of Polymer Composition on the Controlled Release of Docetaxel: A Comparison of Non-Degradable Polymer Films for Oesophageal Drug-Eluting Stents
by Paris Fouladian, Franklin Afinjuomo, Mohammad Arafat, Amanda Bergamin, Yunmei Song, Anton Blencowe and Sanjay Garg
Pharmaceutics 2020, 12(5), 444; https://doi.org/10.3390/pharmaceutics12050444 - 11 May 2020
Cited by 11 | Viewed by 4352
Abstract
Following the huge clinical success of drug-eluting vascular stents, there is a significant interest in the development of drug-eluting stents for other applications, such as the treatment of gastrointestinal (GI) cancers. Central to this process is understanding how particular drugs are released from [...] Read more.
Following the huge clinical success of drug-eluting vascular stents, there is a significant interest in the development of drug-eluting stents for other applications, such as the treatment of gastrointestinal (GI) cancers. Central to this process is understanding how particular drugs are released from stent coatings, which to a large extent is controlled by drug-polymer interactions. Therefore, in this study we investigated the release of docetaxel (DTX) from a selection of non-degradable polymer films. DTX-polymer films were prepared at various loadings (1, 5 and 10% w/w) using three commercially available polymers including poly(dimethylsiloxane) (PSi), poly (ethylene-co-vinyl acetate) (PEVA) and Chronosil polyurethane (PU). The formulations were characterised using different techniques such as photoacoustic Fourier-transform infrared (PA-FTIR) spectrophotometry, X-ray diffraction (XRD) and differential scanning calorimetry (DSC). The effect of DTX on the mechanical properties of the films, in-vitro release, and degradation tests were also assessed. For all polymers and DTX loadings, the drug was found to disperse homogenously without crystallisation within the polymer matrix. While no specific interactions were observed between DTX and PSi or PEVA, hydrogen-bonding appeared to be present between DTX and PU, which resulted in a concentration-dependent decrease in the Young’s moduli of the films due to disruption of inter-polymeric molecular interactions. In addition, the DTX-PU interactions were found to modulate drug release, providing near-linear release over 30 days, which was accompanied by a significant reduction in degradation products. The results indicate that DTX-loaded PU films are excellent candidates for drug-eluting stents for the treatment of oesophageal cancer. Full article
Show Figures

Graphical abstract

18 pages, 3833 KiB  
Article
The Thermal and Mechanical Properties of Poly(ethylene-co-vinyl acetate) Random Copolymers (PEVA) and its Covalently Crosslinked Analogues (cPEVA)
by Ke Wang and Qibo Deng
Polymers 2019, 11(6), 1055; https://doi.org/10.3390/polym11061055 - 17 Jun 2019
Cited by 58 | Viewed by 10778
Abstract
The thermal and mechanical properties of poly(ethylene-co-vinyl acetate) random copolymers (PEVA) and its covalently crosslinked analogues (cPEVA) were controlled by the overall crystallinity of the polymer networks. The cPEVAs with different VA-content were synthesized by thermally-induced crosslinking of linear PEVA with [...] Read more.
The thermal and mechanical properties of poly(ethylene-co-vinyl acetate) random copolymers (PEVA) and its covalently crosslinked analogues (cPEVA) were controlled by the overall crystallinity of the polymer networks. The cPEVAs with different VA-content were synthesized by thermally-induced crosslinking of linear PEVA with dicumyl peroxide (DCP). This work was mainly concerned with the effect of vinyl acetate (VA) content on the crosslinking density, thermal and mechanical properties of PEVAs and cPEVAs, respectively. The chemical composition was analyzed by thermogravimetric analysis and 1H-NMR. The thermal and mechanical properties of PEVAs and cPEVAs have been studied through a series of conventional analytical methods, including gel content determination, different scanning calorimetry, thermogravimetric analysis, dynamic mechanical thermal analysis and traditional mechanical measurements. The experimental results show that the thermal and mechanical properties of PEVAs and cPEVAs increase with decreasing the VA-content. A broad melting transition with a ΔTm in the range from 78 °C to 95 °C was observed for all polymer networks. Full article
(This article belongs to the Special Issue Polymer Structure and Property)
Show Figures

Figure 1

Back to TopTop